{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:21:18Z","timestamp":1759335678428},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2005,2,3]],"date-time":"2005-02-03T00:00:00Z","timestamp":1107388800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Hematol"],"published-print":{"date-parts":[[2005,6]]},"DOI":"10.1007\/s00277-004-1000-6","type":"journal-article","created":{"date-parts":[[2005,2,2]],"date-time":"2005-02-02T09:48:31Z","timestamp":1107337711000},"page":"403-405","source":"Crossref","is-referenced-by-count":11,"title":["Reusable terminal tap water filters for nosocomial legionellosis prevention"],"prefix":"10.1007","volume":"84","author":[{"given":"Ralf-Peter","family":"Vonberg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dagmar","family":"Rotermund-Rauchenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petra","family":"Gastmeier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2005,2,3]]},"reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1007\/s001030050381","volume":"43","author":"Umweltbundesamt","year":"2000","unstructured":"Umweltbundesamt (2000) Nachweis von Legionellen in Trinkwasser und Badebeckenwasser [Detection of Legionella in drinking water and bathing water]. Bundesgesundheitsblatt 43:911\u2013915","journal-title":"Bundesgesundheitsblatt"},{"key":"CR2","first-page":"959","volume":"24","author":"Umweltbundesamt","year":"2000","unstructured":"Umweltbundesamt (2001) Verordnung zur Novellierung der Trinkwasserverordnung vom 21 Mai 2001 [German drinking water regulations revised on 21 May 2001]. Bundesgesundheitsblatt Teil 1 24:959\u2013980","journal-title":"Bundesgesundheitsblatt"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1016\/S0140-6736(83)91203-5","volume":"2","author":"CL Bartlett","year":"1983","unstructured":"Bartlett CL, Kurtz JB, Hutchison JG, Turner GC, Wright AE (1983) Legionella in hospital and hotel water supplies. Lancet 2:1315","journal-title":"Lancet"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/0196-6553(84)90069-5","volume":"12","author":"M Best","year":"1984","unstructured":"Best M, Goetz A, Yu VL (1984) Heat eradication measures for control of nosocomial Legionnaires\u2019 disease. Implementation, education, and cost analysis. Am J Infect Control 12:26\u201330","journal-title":"Am J Infect Control"},{"key":"CR5","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1128\/AEM.44.6.1330-1333.1982","volume":"44","author":"PH Edelstein","year":"1982","unstructured":"Edelstein PH, Whittaker RE, Kreiling RL, Howell CL (1982) Efficacy of ozone in eradication of Legionella pneumophila from hospital plumbing fixtures. Appl Environ Microbiol 44:1330\u20131333","journal-title":"Appl Environ Microbiol"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"2423","DOI":"10.1001\/jama.1988.03720160043028","volume":"259","author":"CM Helms","year":"1988","unstructured":"Helms CM, Massanari RM, Wenzel RP, Pfaller MA, Moyer NP, Hall N (1988) Legionnaires\u2019 disease associated with a hospital water system. A five-year progress report on continuous hyperchlorination. JAMA 259:2423\u20132427","journal-title":"JAMA"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1016\/S0002-9343(99)00459-3","volume":"108","author":"CA Knirsch","year":"2000","unstructured":"Knirsch CA, Jakob K, Schoonmaker D, Kiehlbauch JA, Wong SJ, Della-Latta P, Whittier S, Layton M, Scully B (2000) An outbreak of Legionella micdadei pneumonia in transplant patients: evaluation, molecular epidemiology, and control. Am J Med 108:290\u2013295","journal-title":"Am J Med"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1128\/AEM.49.4.975-980.1985","volume":"49","author":"GB Knudson","year":"1985","unstructured":"Knudson GB (1985) Photoreactivation of UV-irradiated Legionella pneumophila and other Legionella species. Appl Environ Microbiol 49:975\u2013980","journal-title":"Appl Environ Microbiol"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1017\/S0950268800049293","volume":"107","author":"TJ Marrie","year":"1991","unstructured":"Marrie TJ, Haldane D, MacDonald S, Clarke K, Fanning C, Fort-Jost S, Bezanson G, Joly J (1991) Control of endemic nosocomial legionnaires\u2019 disease by using sterile potable water for high risk patients. Epidemiol Infect 107:591\u2013605","journal-title":"Epidemiol Infect"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1053\/jhin.1999.0628","volume":"43","author":"W Mathys","year":"1999","unstructured":"Mathys W, Deng MC, Meyer J, Junge-Mathys E (1999) Fatal nosocomial Legionnaires\u2019 disease after heart transplantation: clinical course, epidemiology and prevention strategies for the highly immunocompromised host. J Hosp Infect 43:242\u2013246","journal-title":"J Hosp Infect"},{"key":"CR11","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s001030050425","volume":"44","author":"FA Pitten","year":"2001","unstructured":"Pitten FA, Rudolph P, Kramer A (2001) Mikrobiologische Qualit\u00e4t von Trinkwasser in Risikobereichen [Microbiological quality of drinking water in high risk areas]. Bundesgesundheitsblatt 44:155\u2013158","journal-title":"Bundesgesundheitsblatt"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1086\/502251","volume":"24","author":"JE Stout","year":"2003","unstructured":"Stout JE, Yu VL (2003) Experiences of the first 16 hospitals using copper\u2013silver ionization for Legionella control: implications for the evaluation of other disinfection modalities. Infect Control Hosp Epidemiol 24:563\u2013568","journal-title":"Infect Control Hosp Epidemiol"},{"key":"CR13","first-page":"1","volume":"53","author":"OC Tablan","year":"2005","unstructured":"Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R (2005) Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. Morb Mort Wkly Rep Recomm Rep 53:1\u201336","journal-title":"Morb Mort Wkly Rep Recomm Rep"},{"key":"CR14","doi-asserted-by":"crossref","unstructured":"Vonberg R, Eckmanns T, Bruderek J, Ruden H, Gastmeier P (2004) Use of terminal tap water filter systems for nosocomial Legionellosis prevention. J Hosp Infect (in press)","DOI":"10.1016\/j.jhin.2004.10.018"},{"key":"CR15","first-page":"379","volume":"307","author":"CW Walter","year":"1982","unstructured":"Walter CW (1982) Legionella pneumophila in a hospital water supply. N Engl J Med 307:379\u2013380","journal-title":"N Engl J Med"},{"key":"CR16","first-page":"515","volume":"196","author":"C Wendt","year":"1995","unstructured":"Wendt C, Weist K, Dietz E, Schlattmann P, Ruden H (1995) Field study to obtain Legionella-free water from showers and sinks of a transplantation unit by a system of water filters. Zentralbl Hyg Umweltmed 196:515\u2013531","journal-title":"Zentralbl Hyg Umweltmed"},{"key":"CR17","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1139\/m96-102","volume":"42","author":"OM Zacheus","year":"1996","unstructured":"Zacheus OM, Martikainen PJ (1996) Effect of heat flushing on the concentrations of Legionella pneumophila and other heterotrophic microbes in hot water systems of apartment buildings. Can J Microbiol 42:811\u2013818","journal-title":"Can J Microbiol"}],"container-title":["Annals of Hematology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00277-004-1000-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00277-004-1000-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00277-004-1000-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,5]],"date-time":"2020-04-05T15:01:59Z","timestamp":1586098919000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00277-004-1000-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,2,3]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["1000"],"URL":"https:\/\/doi.org\/10.1007\/s00277-004-1000-6","relation":{},"ISSN":["0939-5555","1432-0584"],"issn-type":[{"value":"0939-5555","type":"print"},{"value":"1432-0584","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,2,3]]}}}