{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T19:09:20Z","timestamp":1782328160410,"version":"3.54.5"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2004,8,5]],"date-time":"2004-08-05T00:00:00Z","timestamp":1091664000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2005,1]]},"DOI":"10.1007\/s00330-004-2436-8","type":"journal-article","created":{"date-parts":[[2004,8,4]],"date-time":"2004-08-04T16:42:34Z","timestamp":1091637754000},"page":"170-173","source":"Crossref","is-referenced-by-count":52,"title":["Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs"],"prefix":"10.1007","volume":"15","author":[{"given":"J.","family":"Sailer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Scharitzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Peloschek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Giurea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"Imhof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Grampp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2004,8,5]]},"reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"745","DOI":"10.2106\/00004623-198769050-00016","volume":"69A","author":"JR Moreland","year":"1987","unstructured":"Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of axial alignment of the lower extremity. J Bone Joint Surg 69A:745?749","journal-title":"J Bone Joint Surg"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-197759010-00013","volume":"59A","author":"PA Lotke","year":"1977","unstructured":"Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg 59A:77?79","journal-title":"J Bone Joint Surg"},{"key":"CR3","first-page":"48","volume":"280","author":"D Paley","year":"1992","unstructured":"Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs: preoperative planning of uniapicular deformities of the tibia or femur. Clin Orthop 280:48?64","journal-title":"Clin Orthop"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/S0883-5403(88)80054-8","volume":"3","author":"TL Petersen","year":"1988","unstructured":"Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67?72","journal-title":"J Arthroplasty"},{"key":"CR5","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0030-5898(20)31921-0","volume":"25","author":"K Tetsworth","year":"1994","unstructured":"Tetsworth K, Paley D (1994) Malalignment of degenerative arthropathy. Orthop Clin North Am 25:367?377","journal-title":"Orthop Clin North Am"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.2214\/ajr.170.5.9574588","volume":"170","author":"CM Shearman","year":"1998","unstructured":"Shearman CM, Brandser EA, Kathol MH, Clark WA, Callaghan JJ (1998) An easy linear estimation of the mechanical axis on long-leg radiographs. Am J Roentgenol 170:1220?1222","journal-title":"Am J Roentgenol"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"861","DOI":"10.3928\/0147-7447-19900801-09","volume":"13","author":"KA Krackow","year":"1990","unstructured":"Krackow KA, Pepe CL, Galloway EJ (1990) A mathematical analysis of the effect of flexion and rotation an apparent varus\/valgus alignment an the knee. Orthopedics 13:861?868","journal-title":"Orthopedics"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00003086-199304000-00027","volume":"289","author":"S Odenbring","year":"1993","unstructured":"Odenbring S, Berggren AM, Peil L (1993) Roentgenographic assessment of the hip-knee-ankle axis in medial gonarthrosis. A study of reproducibility. Clin Orthop 289:195?196","journal-title":"Clin Orthop"},{"issue":"5","key":"CR9","doi-asserted-by":"crossref","first-page":"633","DOI":"10.3109\/02841859609177689","volume":"37","author":"J Sanfridsson","year":"1996","unstructured":"Sanfridsson J, Ryg L, Eklund K et al (1996) Angular configuration of the knee. Comparison of conventional measurements and the QUESTOR precision radiography system. Acta Radiol 37:633?638","journal-title":"Acta Radiol"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1007\/s00117-003-0872-0","volume":"43","author":"S Grampp","year":"2003","unstructured":"Grampp S, Czerny C, Krestan C, Henk C, Heiner L, Imhof H (2003) Flachbilddetektorsysteme in der Skelettradiologie. Radiologe 43:362?366","journal-title":"Radiologe"},{"key":"CR11","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1007\/s00117-002-0725-2","volume":"42","author":"H Imhof","year":"2002","unstructured":"Imhof H, Dirisamer A, Fischer H, Grampp S, Heiner L, Kaderk M, Krestan C, Kainberger F (2002) Rozessmanagement\ufffdnderung durch den Einsatz von RIS. PACS und Festk\ufffdrperdetektoren. Radiologe 42:344?350","journal-title":"Radiologe"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"2616","DOI":"10.1007\/s003300100828","volume":"11","author":"JJ James","year":"2001","unstructured":"James JJ, Davies AG, Cowen AR, O?Connor PJO (2001) Developments in digital radiography: an equipment update. Eur Radiol 11:2616?2626","journal-title":"Eur Radiol"},{"issue":"Suppl 1","key":"CR13","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/BF03167630","volume":"13","author":"GA May","year":"2000","unstructured":"May GA, Deer DD, Dackiewicz D (2000) Impact of digital radiography on clinical workflow. J Digit Imaging 13(Suppl 1):76?78","journal-title":"J Digit Imaging"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1007\/s00330-003-2126-y","volume":"14","author":"K Eklund","year":"2004","unstructured":"Eklund K, Jonsson K, Lindblom G, Lundin B, Sanfridsson J, Sloth M, Sivberg B (2004) Are digital images good enough? A comparative study of conventional film-screen versus digital radiographs on printed images of total hip replacement. Eur Radiol 14:865?869","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-004-2436-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-004-2436-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-004-2436-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,14]],"date-time":"2024-01-14T02:38:24Z","timestamp":1705199904000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-004-2436-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,8,5]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2005,1]]}},"alternative-id":["2436"],"URL":"https:\/\/doi.org\/10.1007\/s00330-004-2436-8","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,8,5]]}}}