{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T04:31:26Z","timestamp":1784867486237,"version":"3.55.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2005,12,3]],"date-time":"2005-12-03T00:00:00Z","timestamp":1133568000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2006,4]]},"DOI":"10.1007\/s00330-005-0072-6","type":"journal-article","created":{"date-parts":[[2005,12,2]],"date-time":"2005-12-02T15:27:35Z","timestamp":1133537255000},"page":"846-851","source":"Crossref","is-referenced-by-count":57,"title":["Fluoroscopy-controlled voiding cystourethrography in infants and children: Are the radiation risks trivial?"],"prefix":"10.1007","volume":"16","author":[{"given":"Kostas","family":"Perisinakis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Raissaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Damilakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Stratakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Neratzoulakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Gourtsoyiannis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,12,3]]},"reference":[{"key":"72_CR1","doi-asserted-by":"crossref","first-page":"2910","DOI":"10.1007\/s00330-001-1180-6","volume":"12","author":"M Riccabona","year":"2002","unstructured":"Riccabona M (2002) Cystography in infants and children: a critical appraisal of the many forms with special regard to voiding cystourethrography. Eur Radiol 12:2910\u20132918","journal-title":"Eur Radiol"},{"key":"72_CR2","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/s00247-003-1073-8","volume":"34","author":"S Agrawalla","year":"2004","unstructured":"Agrawalla S, Pearce R, Goodman TR (2004) How to perform the perfect voiding cystourethrogram. Pediatr Radiol 34:114\u2013119","journal-title":"Pediatr Radiol"},{"key":"72_CR3","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1007\/s00247-002-0774-8","volume":"32","author":"EJ Hall","year":"2002","unstructured":"Hall EJ (2002) Lessons we have learned from our children: cancer risks from diagnostic radiology. Pediatr Radiol 32:700\u2013706","journal-title":"Pediatr Radiol"},{"issue":"Suppl 3","key":"72_CR4","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1007\/s00247-004-1276-7","volume":"34","author":"OH Suleiman","year":"2004","unstructured":"Suleiman OH (2004) Radiation doses in pediatric radiology: influence of radiation and standards. Pediatr Radiol 34 (Suppl 3):242\u2013246","journal-title":"Pediatr Radiol"},{"issue":"Suppl 1","key":"72_CR5","first-page":"42","volume":"35","author":"R Goodman","year":"2005","unstructured":"Goodman R (2005) Are routine oblique full bladder views necessary in the pediatric voiding cystourethrogram (VCUG)? Pediatr Radiol 35 (Suppl 1):42","journal-title":"Pediatr Radiol"},{"key":"72_CR6","volume-title":"Estimation of effective doses for pediatric X-ray examinations. NRPB-R279,","author":"D Hart","year":"1996","unstructured":"Hart D, Jones DG, Wall BF (1996) Estimation of effective doses for pediatric X-ray examinations. NRPB-R279, National Radiological Protection Board, Chilton"},{"key":"72_CR7","unstructured":"Le Heron JC (1998) CHILDOSE. Ministry of Health, National Radiation Laboratory, Christchurch, New Zealand"},{"key":"72_CR8","volume-title":"Ann ICRP. 26: 2","author":"ICRP 79","year":"1996","unstructured":"ICRP 79 (1996) Radiological protection and safety in medicine. ICRP Publication 79. In: Ann ICRP. 26: 2, Pergamon Press, Oxford"},{"key":"72_CR9","unstructured":"National Research Council (1990) Health effects exposure to low levels of ionizing radiation. BEIR V: National Academy Press, Washington DC"},{"key":"72_CR10","volume-title":"Ann ICRP. 21:1-3","author":"ICRP 60","year":"1990","unstructured":"ICRP 60 (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. In: Ann ICRP. 21:1\u20133. Pergamon Press, Oxford"},{"key":"72_CR11","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1093\/rpd\/nch317","volume":"109","author":"BF Wall","year":"2004","unstructured":"Wall BF (2004) Radiation protection dosimetry for diagnostic radiology patients. Radiat Prot Dosim 109:409\u2013419","journal-title":"Radiat Prot Dosim"},{"key":"72_CR12","doi-asserted-by":"crossref","first-page":"1594","DOI":"10.2214\/ajr.184.5.01841594","volume":"184","author":"SH Kim","year":"2005","unstructured":"Kim SH, Kim SH, Park BK, Jung SY, Hwang SI, Paick JS, Kim SW (2005) CT voiding cystourethrography using 16-MDCT for the evaluation of female urethral diverticula: initial experience. Am J Roentgenol 184:1594\u20131596","journal-title":"Am J Roentgenol"},{"key":"72_CR13","doi-asserted-by":"crossref","first-page":"1423","DOI":"10.1007\/s00330-002-1750-2","volume":"13","author":"AS Borthne","year":"2003","unstructured":"Borthne AS, Pierre-Jerome C, Gjesdal KI, Storaas T, Courivaud F, Eriksen M (2003) Pediatric excretory MR urography: comparative study of enhanced and non-enhanced techniques. Eur Radiol 13:1423\u20131427","journal-title":"Eur Radiol"},{"key":"72_CR14","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1259\/0007-1285-68-810-604","volume":"68","author":"A Almen","year":"1995","unstructured":"Almen A, Mattsson S (1995) The radiation dose to children from X-ray examinations of the pelvis. Br J Radiol 68:604\u2013613","journal-title":"Br J Radiol"},{"key":"72_CR15","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1259\/bjr.72.860.10624342","volume":"72","author":"FW Schultz","year":"1999","unstructured":"Schultz FW, Geleijns J, Holscher HC, Weststrate J, Zonerland HM, Zoetelief J (1999) Radiation burden to pediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital. Br J Radiol 72:763\u2013772","journal-title":"Br J Radiol"},{"key":"72_CR16","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1259\/bjr\/31857098","volume":"76","author":"M Fotakis","year":"2003","unstructured":"Fotakis M, Molybda-Athanasopoulou E, Psarrakos K, Economou I (2003) Radiation doses to pediatric patients up to 5 years of age undergoing micturating cystourethrography examinations and its dependence on patient age: a Monte Carlo study. Br J Radiol 76:812\u2013817","journal-title":"Br J Radiol"},{"key":"72_CR17","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1007\/s00330-003-2144-9","volume":"14","author":"J Persliden","year":"2004","unstructured":"Persliden J, Helmrot E, Hjort P, Resjo M (2004) Dose and image quality in the comparison of analogue and digital techniques in pediatric urology examinations. Eur Radiol 14:638\u2013644","journal-title":"Eur Radiol"},{"key":"72_CR18","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1259\/0007-1285-65-771-225","volume":"65","author":"CL Chapple","year":"1992","unstructured":"Chapple CL, Faulkner K, Lee REJ, Hunter EW (1992) Results of a survey of doses to paediatric patients undergoing common radiological examinations. Br J Radiol 65:225\u2013231","journal-title":"Br J Radiol"},{"key":"72_CR19","doi-asserted-by":"crossref","first-page":"137","DOI":"10.2214\/ajr.158.1.1727340","volume":"152","author":"RH Cleveland","year":"1992","unstructured":"Cleveland RH, Constantinou C, Blickman JG, Jaramillo D, Webster E (1992) Voiding cystourethrography in children: value of digital fluoroscopy in reducing radiation dose. Am J Roentgenol 152:137\u2013142","journal-title":"Am J Roentgenol"},{"key":"72_CR20","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Brendon WE (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 176:289\u2013296","journal-title":"Am J Roentgenol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-005-0072-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-005-0072-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-005-0072-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T09:36:10Z","timestamp":1586597770000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-005-0072-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,12,3]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2006,4]]}},"alternative-id":["72"],"URL":"https:\/\/doi.org\/10.1007\/s00330-005-0072-6","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,12,3]]}}}