{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T14:07:04Z","timestamp":1702044424292},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2006,4,19]],"date-time":"2006-04-19T00:00:00Z","timestamp":1145404800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2006,8]]},"DOI":"10.1007\/s00330-006-0230-5","type":"journal-article","created":{"date-parts":[[2006,4,18]],"date-time":"2006-04-18T05:39:26Z","timestamp":1145338766000},"page":"1684-1691","source":"Crossref","is-referenced-by-count":29,"title":["Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children"],"prefix":"10.1007","volume":"16","author":[{"given":"Dagmar","family":"Honnef","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joachim E.","family":"Wildberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Das","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Hohl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas H.","family":"Mahnken","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Barker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf W.","family":"G\u00fcnther","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gundula","family":"Staatz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2006,4,19]]},"reference":[{"key":"230_CR1","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1007\/s003300050218","volume":"7","author":"GR Ferreti","year":"1997","unstructured":"Ferreti GR, Knoplioch J, Bricault I, Brambilla C, Coulomb M (1997) Central airway stenosis: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients. Eur Radiol 7:854\u2013859","journal-title":"Eur Radiol"},{"key":"230_CR2","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.2214\/ajr.178.5.1781195","volume":"178","author":"H Hoppe","year":"2002","unstructured":"Hoppe H, Walder B, Sonnenschein M, Vock P, Dinkel HP (2002) Multidetector CT virtual bronchoscopy to grade tracheobronchial stenosis. Am J Roentgenol 178:1195\u20131200","journal-title":"Am J Roentgenol"},{"key":"230_CR3","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/00004728-199705000-00013","volume":"21","author":"J Rodenwaldt","year":"1997","unstructured":"Rodenwaldt J, Kopka L, Roedel R, Margas A, Grabbe E (1997) 3D virtual endoscopy of the upper airway: optimization of the scan parameters in a cadaver phantom and clinical assessment. J Comput Assist Tomogr 21:405\u2013411","journal-title":"J Comput Assist Tomogr"},{"key":"230_CR4","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1378\/chest.109.2.549","volume":"109","author":"DJ Vining","year":"1996","unstructured":"Vining DJ, Liu K, Choplin RH, Haponik EF (1996) Virtual bronchoscopy: relationships of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest 109:549\u2013553","journal-title":"Chest"},{"key":"230_CR5","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1055\/s-2004-813198","volume":"176","author":"D Honnef","year":"2004","unstructured":"Honnef D, Wildberger JE, Stargardt A, Hohl C, Barker M, Gunther RW, Staatz G (2004) Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations. Fortschr R\u00f6ntgenstr 176:1021\u20131030","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"230_CR6","volume-title":"Practical statistics for medical research","author":"DG Altman","year":"1991","unstructured":"Altman DG (1991) Practical statistics for medical research. Chapman & Hall, Boca Raton, FL"},{"key":"230_CR7","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1055\/s-2002-35937","volume":"174","author":"G Stamm","year":"2002","unstructured":"Stamm G, Nagel HD (2002) CT-expo: a novel program for dose evaluation in CT. Fortschr R\u00f6ntgenstr 174:1570\u20131576","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"230_CR8","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1148\/radiographics.21.5.g01se021257","volume":"21","author":"LP Lawler","year":"2001","unstructured":"Lawler LP, Fishman EK (2001) Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography. RadioGraphics 21:1257\u20131273","journal-title":"RadioGraphics"},{"key":"230_CR9","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1148\/radiology.215.1.r00ap3755","volume":"215","author":"H Hu","year":"2000","unstructured":"Hu H, He HD, Foley WD, Fox SH (2000) Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 215:55\u201362","journal-title":"Radiology"},{"key":"230_CR10","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/S0720-048X(99)00086-8","volume":"31","author":"K Klingenbeck-Regn","year":"1999","unstructured":"Klingenbeck-Regn K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol 31:110\u2013124","journal-title":"Eur J Radiol"},{"key":"230_CR11","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.2214\/ajr.171.6.9843316","volume":"171","author":"E Konen","year":"1998","unstructured":"Konen E, Katz M, Rozenman J, Ben-Shlush A, Itzchak Y, Szeinberg A (1998) Virtual bronchoscopy in children: early clinical experience. Am J Roentgenol 171:1699\u20131702","journal-title":"Am J Roentgenol"},{"key":"230_CR12","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.2214\/ajr.174.4.1741009","volume":"174","author":"WW Lam","year":"2000","unstructured":"Lam WW, Tam PK, Chan FL, Chan KL, Cheng W (2000) Esophageal atresia and tracheal stenosis: use of three-dimensional CT and virtual bronchoscopy in neonates, infants, and children. Am J Roentgenol 174:1009\u20131012","journal-title":"Am J Roentgenol"},{"key":"230_CR13","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1007\/s002470000325","volume":"30","author":"RA Cohen","year":"2000","unstructured":"Cohen RA, Frush DP, Donnelly LF (2000) Data acquisition for pediatric CT angiography: problems and solutions. Pediatr Radiol 30:813\u2013822","journal-title":"Pediatr Radiol"},{"key":"230_CR14","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.2214\/ajr.183.6.01831771","volume":"183","author":"P Kosucu","year":"2004","unstructured":"Kosucu P, Ahmetoglu A, Koramaz I, Orhan F, Ozdemir O, Dinc H, Okten A, Gumele HR (2004) Low-dose MDCT and virtual bronchoscopy in pediatric patients with foreign body aspiration. Am J Roentgenol 183:1771\u20131777","journal-title":"Am J Roentgenol"},{"key":"230_CR15","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1055\/s-2004-814585","volume":"83","author":"A M\u00fcller","year":"2004","unstructured":"M\u00fcller A (2004) Modern diagnostics of tracheal stenosis. Laryngo-Rhino-Otol 83:381\u2013386","journal-title":"Laryngo-Rhino-Otol"},{"key":"230_CR16","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1055\/s-2001-11758","volume":"173","author":"A Bode","year":"2001","unstructured":"Bode A, Dammann F, Pelikan EH, Heuschmid M, Schwaderer E, Schaich M, Claussen CD (2001) Analysis of artefacts by virtual endoscopy visualization of spiral CT data. Fortschr R\u00f6ntgenstr 173:245\u2013252","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"230_CR17","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1148\/radiol.2293020999","volume":"229","author":"MJ Siegel","year":"2003","unstructured":"Siegel MJ (2003) Multiplanar and three-dimensional multi-detector row CT of thoracic vessels and airways in the pediatric population. Radiology 229:641\u2013650","journal-title":"Radiology"},{"key":"230_CR18","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1007\/s00247-001-0574-6","volume":"32","author":"E Sorantin","year":"2002","unstructured":"Sorantin E, Geiger B, Lindbichler F, Eber E, Schimpl G (2002) CT-based virtual tracheobronchoscopy in children: comparison with axial CT and multiplanar reconstruction-preliminary results. Pediatr Radiol 32:8\u201315","journal-title":"Pediatr Radiol"},{"key":"230_CR19","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/S0720-048X(02)00295-4","volume":"48","author":"M Haliloglu","year":"2003","unstructured":"Haliloglu M, Ciftci AO, Oto A, Gumus B, Tanyel FC, Senocak ME, Buyukpamukcu N, Besim A (2003) CT virtual bronchoscopy in the evaluation of children with suspected foreign body aspiration. Eur J Radiol 48:188\u2013192","journal-title":"Eur J Radiol"},{"key":"230_CR20","doi-asserted-by":"crossref","first-page":"345","DOI":"10.2214\/ajr.154.2.2105029","volume":"154","author":"SC Kao","year":"1990","unstructured":"Kao SC, Smith WL, Sato Y, Franken EA Jr, Kimura K, Soper RT (1990) Ultrafast CT of laryngeal and tracheobronchial obstruction in symptomatic postoperative infants with esophageal atresia and tracheoesophageal fistula. Am J Roentgenol 154:345\u2013350","journal-title":"Am J Roentgenol"},{"issue":"12","key":"230_CR21","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1097\/00005537-200112000-00022","volume":"111","author":"RA Faust","year":"2001","unstructured":"Faust RA, Remley KB, Rimell FL (2001) Real-time, cine magnetic resonance imaging for evaluation of the pediatric airway. Laryngoscope 111(12):2187\u20132190","journal-title":"Laryngoscope"},{"key":"230_CR22","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","volume":"176","author":"DJ Brenner","year":"2001","unstructured":"Brenner DJ, Elliston CD, Hall EJ, Berdon WE (2001) Estimated risks of radiation induced fatal cancer from pediatric CT. Am J Roentgenol 176:289\u2013296","journal-title":"Am J Roentgenol"},{"key":"230_CR23","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s002470000423","volume":"31","author":"HK Lee","year":"2001","unstructured":"Lee HK, Yoon CS, Choe KO, Kim MJ, Lee HM, Yoon HK, Kim B (2001) Use of imaging for assessing anatomical relationships of tracheobronchial anomalies associated with left pulmonary artery sling. Pediatr Radiol 31:269\u2013278","journal-title":"Pediatr Radiol"},{"key":"230_CR24","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/S0003-4975(01)03405-1","volume":"73","author":"YM Kim","year":"2002","unstructured":"Kim YM, Yoo SJ, Kim WH, KIM TH, Joh JH, Kim SJ (2002) Bronchial compression by posteriorly displaced ascending aorta in patients with congenital heart disease. Ann Thorac Surg 73:881\u2013886","journal-title":"Ann Thorac Surg"},{"key":"230_CR25","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1002\/ppul.20077","volume":"38","author":"CM Heyer","year":"2004","unstructured":"Heyer CM, Kagel T, Lemburg SP, Nicolas V, Rieger CHL (2004) Evaluation of tracheobronchial anomalies in children using low-dose multidetector CT: Report of a 13-year-old boy with a tracheal bronchus and recurrent pulmonary infections. Pediatr Pulmonol 38:168\u2013173","journal-title":"Pediatr Pulmonol"},{"key":"230_CR26","doi-asserted-by":"crossref","first-page":"777","DOI":"10.2214\/ajr.182.3.1820777","volume":"182","author":"EY Lee","year":"2004","unstructured":"Lee EY, Siegel MJ, Hildebolt CF, Gutierrez FR, Bhalla S, Fallah JH (2004) MDCT evaluation of thoracic aortic anomalies in pediatric patients and young adults: comparison of axial, multiplanar, and 3D images. Am J Roentgenol 182:777\u2013784","journal-title":"Am J Roentgenol"},{"key":"230_CR27","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1007\/s00247-002-0800-x","volume":"32","author":"C Suess","year":"2002","unstructured":"Suess C, Che X (2002) Dose optimization in pediatric CT: current technology and future innovations. Pediatr Radiol 32:729\u2013734","journal-title":"Pediatr Radiol"},{"key":"230_CR28","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.2214\/ajr.184.5.01841706","volume":"184","author":"K McHugh","year":"2005","unstructured":"McHugh K (2005) CT dose reduction in pediatric patients. Am J Roentgenol 184:1706","journal-title":"Am J Roentgenol"},{"key":"230_CR29","doi-asserted-by":"crossref","first-page":"2330","DOI":"10.1007\/s00330-005-2856-0","volume":"15","author":"P Vock","year":"2005","unstructured":"Vock P (2005) CT dose reduction in children. Eur Radiol 15:2330\u20132340","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-006-0230-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-006-0230-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-006-0230-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T07:53:20Z","timestamp":1559030000000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-006-0230-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,4,19]]},"references-count":29,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2006,8]]}},"alternative-id":["230"],"URL":"https:\/\/doi.org\/10.1007\/s00330-006-0230-5","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,4,19]]}}}