{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T11:02:23Z","timestamp":1768647743209,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2009,4,28]],"date-time":"2009-04-28T00:00:00Z","timestamp":1240876800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2009,9]]},"DOI":"10.1007\/s00330-009-1397-3","type":"journal-article","created":{"date-parts":[[2009,4,27]],"date-time":"2009-04-27T12:55:09Z","timestamp":1240836909000},"page":"2232-2237","source":"Crossref","is-referenced-by-count":53,"title":["Ultrasound-guided percutaneous release of the annular pulley in trigger digit"],"prefix":"10.1007","volume":"19","author":[{"given":"Gajan","family":"Rajeswaran","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin C.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rupert","family":"Eckersley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Effie","family":"Katsarma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeremiah C.","family":"Healy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,4,28]]},"reference":[{"key":"1397_CR1","first-page":"142","volume":"24","author":"A Notta","year":"1850","unstructured":"Notta A (1850) Recherches sur une affection particuli\u00e8re des gaines tendineuses de la main. Arch Gen Med 24:142","journal-title":"Arch Gen Med"},{"issue":"3","key":"1397_CR2","doi-asserted-by":"crossref","first-page":"166","DOI":"10.5435\/00124635-200703000-00006","volume":"15","author":"SB Fleisch","year":"2007","unstructured":"Fleisch SB, Spindler KP, Lee DH (2007) Corticosteroid injections in the treatment of trigger finger: a level I and II systematic review. J Am Acad Orthop Surg 15(3):166\u2013171","journal-title":"J Am Acad Orthop Surg"},{"issue":"1","key":"1397_CR3","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jhsa.2005.10.013","volume":"31","author":"M Ryzewicz","year":"2006","unstructured":"Ryzewicz M, Wolf JM (2006) Trigger digits: principles, management, and complications. J Hand Surg [Am] 31(1):135\u201346","journal-title":"J Hand Surg [Am]"},{"issue":"2","key":"1397_CR4","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.jhsb.2005.11.003","volume":"31","author":"IM Jou","year":"2006","unstructured":"Jou IM, Chern TC (2006) Sonographically assisted percutaneous release of the A1 pulley: a new surgical technique for treating trigger digit. J Hand Surg [Br] 31(2):191\u2013199","journal-title":"J Hand Surg [Br]"},{"issue":"6","key":"1397_CR5","first-page":"1577","volume":"25","author":"JC Lee","year":"2006","unstructured":"Lee JC, Healy JC (2006) Normal sonographic anatomy of the hand and wrist. Radiographics 25(6):1577\u20131590","journal-title":"Radiographics"},{"issue":"1","key":"1397_CR6","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/0363-5023(92)90124-8","volume":"17","author":"MR Patel","year":"1992","unstructured":"Patel MR, Bassini L (1992) Trigger fingers and thumb: when to splint, inject, or operate. J Hand Surg [Am] 17(1):110\u2013113","journal-title":"J Hand Surg [Am]"},{"issue":"1","key":"1397_CR7","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/S0363-5023(05)80195-9","volume":"22","author":"GA Turowski","year":"1997","unstructured":"Turowski GA, Zdankiewicz PD, Thomson JG (1997) The results of surgical treatment of trigger finger. J Hand Surg [Am] 22(1):145\u2013149","journal-title":"J Hand Surg [Am]"},{"issue":"3","key":"1397_CR8","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1053\/jhsu.2001.24967","volume":"26","author":"EC Gilberts","year":"2001","unstructured":"Gilberts EC, Beekman WH, Stevens HJ, Wereldsma JC (2001) Prospective randomized trial of open versus percutaneous surgery for trigger digits. J Hand Surg [Am] 26(3):497\u2013500","journal-title":"J Hand Surg [Am]"},{"issue":"4","key":"1397_CR9","doi-asserted-by":"crossref","first-page":"246","DOI":"10.5435\/00124635-200107000-00004","volume":"9","author":"MJ Saldana","year":"2001","unstructured":"Saldana MJ (2001) Trigger digits: diagnosis and treatment. J Am Acad Orthop Surg 9(4):246\u2013252","journal-title":"J Am Acad Orthop Surg"},{"issue":"2","key":"1397_CR10","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/0266-7681(92)90101-7","volume":"17","author":"E Panayotopoulos","year":"1992","unstructured":"Panayotopoulos E, Fortis AP, Armoni A, Dimakopoulos P, Lambiris E (1992) Trigger digit: the needle or the knife? J Hand Surg [Br] 17(2):239\u2013240","journal-title":"J Hand Surg [Br]"},{"issue":"4","key":"1397_CR11","doi-asserted-by":"crossref","first-page":"793","DOI":"10.2106\/00004623-195840040-00003","volume":"40-A","author":"J Lorthioir Jr","year":"1958","unstructured":"Lorthioir J Jr (1958) Surgical treatment of trigger-finger by a subcutaneous method. J Bone Joint Surg Am 40-A(4):793\u2013795","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"1397_CR12","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1002\/jor.1100040112","volume":"4","author":"WW Peterson","year":"1986","unstructured":"Peterson WW, Manske PR, Bollinger BA, Lesker PA, McCarthy JA (1986) Effect of pulley excision on flexor tendon biomechanics. J Orthop Res 4(1):96\u2013101","journal-title":"J Orthop Res"},{"issue":"5","key":"1397_CR13","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/S0363-5023(05)80430-7","volume":"20","author":"GI Bain","year":"1995","unstructured":"Bain GI, Turnbull J, Charles MN, Roth JH, Richards RS (1995) Percutaneous A1 pulley release: a cadaveric study. J Hand Surg [Am] 20(5):781\u2013784 discussion 785\u2013786","journal-title":"J Hand Surg [Am]"},{"issue":"2","key":"1397_CR14","doi-asserted-by":"crossref","first-page":"167","DOI":"10.3109\/17453679809117620","volume":"69","author":"B Cihantimur","year":"1998","unstructured":"Cihantimur B, Akin S, Ozcan M (1998) Percutaneous treatment of trigger finger. 34 fingers followed 0.5\u20132\u00a0years. Acta Orthop Scand 69(2):167\u2013168","journal-title":"Acta Orthop Scand"},{"issue":"2 Pt 1","key":"1397_CR15","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/0363-5023(89)90006-3","volume":"14","author":"J Carrozzella","year":"1989","unstructured":"Carrozzella J, Stern PJ, Von Kuster LC (1989) Transection of radial digital nerve of the thumb during trigger release. J Hand Surg [Am] 14(2 Pt 1):198\u2013200","journal-title":"J Hand Surg [Am]"},{"issue":"4","key":"1397_CR16","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1053\/jhsu.1999.0860","volume":"24","author":"MJ Dunn","year":"1999","unstructured":"Dunn MJ, Pess GM (1999) Percutaneous trigger finger release: a comparison of a new push knife and a 19-gauge needle in a cadaveric model. J Hand Surg [Am] 24(4):860\u2013865","journal-title":"J Hand Surg [Am]"},{"issue":"1","key":"1397_CR17","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/0363-5023(92)90125-9","volume":"17","author":"DM Eastwood","year":"1992","unstructured":"Eastwood DM, Gupta KJ, Johnson DP (1992) Percutaneous release of the trigger finger: an office procedure. J Hand Surg [Am] 17(1):114\u2013117","journal-title":"J Hand Surg [Am]"},{"issue":"1","key":"1397_CR18","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1302\/0301-620X.83B1.11247","volume":"83","author":"KI Ha","year":"2001","unstructured":"Ha KI, Park MJ, Ha CW (2001) Percutaneous release of trigger digits. J Bone Joint Surg Br 83(1):75\u201377","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"1397_CR19","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/S0363-5023(88)80097-2","volume":"13","author":"SJ Heithoff","year":"1988","unstructured":"Heithoff SJ, Millender LH, Helman J (1988) Bowstringing as a complication of trigger finger release. J Hand Surg [Am] 13(4):567\u2013570","journal-title":"J Hand Surg [Am]"},{"issue":"3","key":"1397_CR20","first-page":"418","volume":"74","author":"SR Lyu","year":"1992","unstructured":"Lyu SR (1992) Closed division of the flexor tendon sheath for trigger finger. J Bone Joint Surg Br 74(3):418\u2013420","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"1397_CR21","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/S0363-5023(05)80026-7","volume":"20","author":"DF Pope","year":"1995","unstructured":"Pope DF, Wolfe SW (1995) Safety and efficacy of percutaneous trigger finger release. J Hand Surg [Am] 20(2):280\u2013283","journal-title":"J Hand Surg [Am]"},{"issue":"2","key":"1397_CR22","first-page":"116","volume":"39","author":"J Stothard","year":"1994","unstructured":"Stothard J, Kumar A (1994) A safe percutaneous procedure for trigger finger release. J R Coll Surg Edinb 39(2):116\u2013117","journal-title":"J R Coll Surg Edinb"},{"issue":"4","key":"1397_CR23","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/0266-7681(90)90091-H","volume":"15","author":"J Tanaka","year":"1990","unstructured":"Tanaka J, Muraji M, Negoro H, Yamashita H, Nakano T, Nakano K (1990) Subcutaneous release of trigger thumb and fingers in 210 fingers. J Hand Surg [Br] 15(4):463\u2013465","journal-title":"J Hand Surg [Br]"},{"issue":"1","key":"1397_CR24","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/S0363-5023(05)80196-0","volume":"22","author":"MR Patel","year":"1997","unstructured":"Patel MR, Moradia VJ (1997) Percutaneous release of trigger digit with and without cortisone injection. J Hand Surg [Am] 22(1):150\u2013155","journal-title":"J Hand Surg [Am]"},{"issue":"5","key":"1397_CR25","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1097\/01.PRS.0000057969.87632.a8","volume":"111","author":"BJ Wilhelmi","year":"2003","unstructured":"Wilhelmi BJ, Mowlavi A, Neumeister MW, Bueno R, Ketchum J, Lee WP (2003) Surface landmarks to locate the thenar branch of the median nerve: an anatomical study. Plast Reconstr Surg 111(5):1612\u20131615","journal-title":"Plast Reconstr Surg"},{"issue":"5","key":"1397_CR26","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/S0363-5023(05)80431-9","volume":"20","author":"LB Lane","year":"1995","unstructured":"Lane LB (1995) Percutaneous release of the first annular pulley. J Hand Surg [Am] 20(5):785\u2013786","journal-title":"J Hand Surg [Am]"},{"issue":"3","key":"1397_CR27","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1097\/01.PRS.0000152419.76354.67","volume":"115","author":"TC Chern","year":"2005","unstructured":"Chern TC, Jou IM, Yen SH, Lai KA, Shao CJ (2005) Cadaveric study of sonographically assisted percutaneous release of the A1 pulley. Plast Reconstr Surg 115(3):811\u2013822","journal-title":"Plast Reconstr Surg"},{"issue":"3","key":"1397_CR28","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/s00264-006-0180-1","volume":"31","author":"O Cebesoy","year":"2007","unstructured":"Cebesoy O, Kose KC, Baltaci ET, Isik M (2007) Percutaneous release of the trigger thumb: is it safe, cheap and effective? Int Orthop 31(3):345\u2013349","journal-title":"Int Orthop"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1397-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-009-1397-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1397-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T11:54:42Z","timestamp":1559044482000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-009-1397-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4,28]]},"references-count":28,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["1397"],"URL":"https:\/\/doi.org\/10.1007\/s00330-009-1397-3","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,28]]}}}