{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:20:48Z","timestamp":1761862848435},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2009,5,9]],"date-time":"2009-05-09T00:00:00Z","timestamp":1241827200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2009,10]]},"DOI":"10.1007\/s00330-009-1433-3","type":"journal-article","created":{"date-parts":[[2009,5,8]],"date-time":"2009-05-08T10:18:27Z","timestamp":1241777907000},"page":"2407-2415","source":"Crossref","is-referenced-by-count":9,"title":["Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?"],"prefix":"10.1007","volume":"19","author":[{"given":"Fabrizio","family":"Fanelli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael D.","family":"Dake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Filippo Maria","family":"Salvatori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armando","family":"Pucci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Mazzesi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierleone","family":"Lucatelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Plinio","family":"Rossi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Passariello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,5,9]]},"reference":[{"key":"1433_CR1","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1148\/radiol.2291020905","volume":"229","author":"R Fattori","year":"2003","unstructured":"Fattori R, Napoli G, Lovato L et al (2003) Descending thoracic aortic diseases: stent-graft repair. Radiology 229:176\u2013183","journal-title":"Radiology"},{"key":"1433_CR2","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1046\/j.1540-8191.2003.02078.x","volume":"18","author":"K Tiesenhausen","year":"2003","unstructured":"Tiesenhausen K, Hausegger KA, Oberwalder P et al (2003) Left subclavian artery management in endovascular repair of thoracic aortic aneurysms and aortic dissections. J Card Surg 18:429\u2013435","journal-title":"J Card Surg"},{"key":"1433_CR3","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1583\/04-1311R.1","volume":"11","author":"TC Rehders","year":"2004","unstructured":"Rehders TC, Petzsch M, Ince H et al (2004) Intentional occlusion of the left subclavian artery during stent-graft implantation in the thoracic aorta: risk and relevance. J Endovasc Ther 11:659\u2013666","journal-title":"J Endovasc Ther"},{"key":"1433_CR4","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1177\/15266028020090S207","volume":"9","author":"J G\u00f6rich","year":"2002","unstructured":"G\u00f6rich J, Asquan Y, Seifarth H et al (2002) Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs. J Endovasc Ther 9:39\u201343","journal-title":"J Endovasc Ther"},{"key":"1433_CR5","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1016\/S0003-4975(02)03397-0","volume":"73","author":"JH Palma","year":"2002","unstructured":"Palma JH, De Souza JA, Rodrigues Alves CM et al (2002) Self-expandable aortic stent-grafts for treatment of descending aortic dissections. Ann Thorac Surg 73:1138\u20131142","journal-title":"Ann Thorac Surg"},{"key":"1433_CR6","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1016\/j.jtcvs.2008.05.036","volume":"136","author":"MD Peterson","year":"2008","unstructured":"Peterson MD, Wheatley GH 3rd, Kpodonu J et al (2008) Treatment of type II endoleaks associated with left subclavian artery coverage during thoracic aortic stent grafting. J Thorac Cardiovasc Surg 136:1193\u20131199","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1433_CR7","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.jvs.2006.08.076","volume":"45","author":"PJ Riesenman","year":"2007","unstructured":"Riesenman PJ, Farber MA, Mendes RR et al (2007) Coverage of the left subclavian artery during thoracic endovascular aortic repair. J Vasc Surg 45:90\u201394","journal-title":"J Vasc Surg"},{"key":"1433_CR8","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1007\/s00464-005-0526-6","volume":"20","author":"R Caronno","year":"2006","unstructured":"Caronno R, Piffaretti G, Tozzi M et al (2006) Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease. Surg Endosc 20:915\u2013918","journal-title":"Surg Endosc"},{"key":"1433_CR9","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1583\/03-1180.1","volume":"11","author":"RG McWilliams","year":"2004","unstructured":"McWilliams RG, Murphy M, Hartley D et al (2004) In situ stent-graft fenestration to preserve the left subclavian artery. J Endovasc Ther 11:170\u2013174","journal-title":"J Endovasc Ther"},{"key":"1433_CR10","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.jvs.2004.11.030","volume":"41","author":"N Saito","year":"2005","unstructured":"Saito N, Kimura T, Odashiro K et al (2005) Feasibility of the Inoue single-branched stent-graft implantation for thoracic aortic aneurysm or dissection involving the left subclavian artery: short to medium term results in 17 patients. J Vasc Surg 41:206\u2013212","journal-title":"J Vasc Surg"},{"key":"1433_CR11","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0741-5214(03)01023-1","volume":"38","author":"TA Chuter","year":"2003","unstructured":"Chuter TA, Schneider DB, Reilly LM et al (2003) Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection. J Vasc Surg 38:859\u2013863","journal-title":"J Vasc Surg"},{"key":"1433_CR12","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.ejvs.2004.01.008","volume":"27","author":"AW Vos","year":"2004","unstructured":"Vos AW, Linsen MA, Wisselink W et al (2004) Endovascular grafting of complex aortic aneurysms with a modular side branch stent-graft system in porcine model. Eur J Vasc Endovasc Surg 27:492\u2013497","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"1433_CR13","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1007\/s00270-007-9147-x","volume":"30","author":"M Thompson","year":"2007","unstructured":"Thompson M, Ivaz S, Cheshire N et al (2007) Early results of endovascular treatment of the thoracic aorta using the Valiant endograft. Cardiovasc Intervent Radiol 30:1130\u20131138","journal-title":"Cardiovasc Intervent Radiol"},{"key":"1433_CR14","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.jvs.2005.11.049","volume":"43","author":"BG Peterson","year":"2006","unstructured":"Peterson BG, Eskandari MK, Gleason TG et al (2006) Utility of the left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology. J Vasc Surg 43:433\u2013439","journal-title":"J Vasc Surg"},{"key":"1433_CR15","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1016\/j.jvs.2007.08.020","volume":"46","author":"J Buth","year":"2007","unstructured":"Buth J, Harris PL, Hobo R et al (2007) Neurologic complications associated with endovascular repair of thoracic aortic pathology: incidence and risk factors. a study from the European Collaborators on Stent\/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry. J Vasc Surg 46:1103\u20131110","journal-title":"J Vasc Surg"},{"key":"1433_CR16","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1510\/icvts.2008.181222","volume":"7","author":"J Dunning","year":"2008","unstructured":"Dunning J, Martin JE, Shennib H et al (2008) Is it safe to cover the left subclavian artery when placing an endovascular stent in the descending thoracic aorta? Interact Cardiovasc Thorac Surg 7:690\u2013697","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"1433_CR17","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.jvs.2008.03.060","volume":"48","author":"EY Woo","year":"2008","unstructured":"Woo EY, Carpenter JP, Jackson BM et al (2008) Left subclavian artery coverage during thoracic endovascular aortic repair: a single-center experience. J Vasc Surg 48:555\u2013560","journal-title":"J Vasc Surg"},{"key":"1433_CR18","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1067\/mva.2002.120035","volume":"35","author":"CS Cina","year":"2002","unstructured":"Cina CS, Safar HA, Lagan\u00e0 A et al (2002) Subclavian carotid transposition and bypass grafting: consecutive cohort study and systematic review. J Vasc Surg 35:422\u2013429","journal-title":"J Vasc Surg"},{"key":"1433_CR19","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1583\/08-2364.1","volume":"15","author":"L Qu","year":"2008","unstructured":"Qu L, Raithel D (2008) Two-year single-center experience with thoracic endovascular aortic repair using the EndoFit thoracic stent-graft. J Endovasc Ther 15:530\u2013538","journal-title":"J Endovasc Ther"},{"key":"1433_CR20","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S0022-5223(98)00455-3","volume":"116","author":"MD Dake","year":"1998","unstructured":"Dake MD, Miller DC, Mitchell RS et al (1998) The \u201cfirst generation\u201d of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta. J Thorac Cardiovasc Surg 116:689\u2013704","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1433_CR21","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.jtcvs.2005.11.009","volume":"131","author":"M Schoder","year":"2006","unstructured":"Schoder M, Grabenwoger M, H\u00f6lzenbein T et al (2006) Endovascular repair of the thoracic aorta necessitating anchoring of the stent graft across the arch vessels. J Thorac Cardiovasc Surg 131:380\u2013387","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1433_CR22","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0003-4975(98)00390-7","volume":"66","author":"M Ehrlich","year":"1998","unstructured":"Ehrlich M, Grabenwoeger M, Cartes-Zumelzu F et al (1998) Endovascular stent graft repair for aneurysms on the descending thoracic aorta. Ann Thorac Surg 66:19\u201325","journal-title":"Ann Thorac Surg"},{"key":"1433_CR23","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0003-4975(99)01291-6","volume":"69","author":"M Grabenwoger","year":"2000","unstructured":"Grabenwoger M, Hutschala D, Ehrlich MP et al (2000) Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts. Ann Thorac Surg 69:441\u2013445","journal-title":"Ann Thorac Surg"},{"key":"1433_CR24","first-page":"316","volume":"2","author":"K Inoue","year":"1999","unstructured":"Inoue K, Hosokawa H, Iwase T et al (1999) Aortic arch reconstruction by transluminally placed endovascular branched stent-graft. Circulation 2:316\u2013321","journal-title":"Circulation"},{"key":"1433_CR25","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1253\/circj.72.449","volume":"72","author":"Y Kurimoto","year":"2008","unstructured":"Kurimoto Y, Ito T, Harada R et al (2008) Management of left subclavian artery in endovascular stent-grafting for distal aortic arch disease. Circ J 72:449\u2013453","journal-title":"Circ J"},{"key":"1433_CR26","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1583\/06-2010.1","volume":"14","author":"FJ Criado","year":"2007","unstructured":"Criado FJ (2007) A percutaneous technique for preservation of arch branch patency during thoracic endovascular aortic repair (TEVAR): retrograde catheterization and stenting. J Endovasc Ther 14:54\u201358","journal-title":"J Endovasc Ther"},{"key":"1433_CR27","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1583\/07-2315.1","volume":"15","author":"T Ohrlander","year":"2008","unstructured":"Ohrlander T, Sonesson B, Ivancev K et al (2008) The chimney graft: a technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones. J Endovasc Ther 15:427\u2013432","journal-title":"J Endovasc Ther"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1433-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-009-1433-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1433-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T11:54:43Z","timestamp":1559044483000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-009-1433-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,9]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["1433"],"URL":"https:\/\/doi.org\/10.1007\/s00330-009-1433-3","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,9]]}}}