{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T22:46:50Z","timestamp":1782168410756,"version":"3.54.5"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2009,8,6]],"date-time":"2009-08-06T00:00:00Z","timestamp":1249516800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2010,1]]},"DOI":"10.1007\/s00330-009-1523-2","type":"journal-article","created":{"date-parts":[[2009,8,5]],"date-time":"2009-08-05T06:24:37Z","timestamp":1249453477000},"page":"16-24","source":"Crossref","is-referenced-by-count":120,"title":["Breast tomosynthesis in clinical practice: initial results"],"prefix":"10.1007","volume":"20","author":[{"given":"Hendrik J.","family":"Teertstra","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudette E.","family":"Loo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maurice A. A. J.","family":"van den Bosch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harm","family":"van Tinteren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emiel J. T.","family":"Rutgers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara H.","family":"Muller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth G. A.","family":"Gilhuijs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,8,6]]},"reference":[{"key":"1523_CR1","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/S0039-6109(03)00034-3","volume":"83","author":"SE Singletary","year":"2003","unstructured":"Singletary SE, Allred C, Ashley P et al (2003) Staging system for breast cancer: revisions for the 6th edition of the AJCC Cancer Staging Manual. Surg Clin North Am 83:803\u2013819","journal-title":"Surg Clin North Am"},{"key":"1523_CR2","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0009-9260(05)80218-1","volume":"44","author":"MG Wallis","year":"1991","unstructured":"Wallis MG, Walsh MT, Lee JR (1991) A review of false negative mammography in a symptomatic population. Clin Radiol 44:13\u201315","journal-title":"Clin Radiol"},{"key":"1523_CR3","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/S0009-9260(05)83454-3","volume":"49","author":"EC Coveney","year":"1994","unstructured":"Coveney EC, Geraghty JG, O\u2019Laide R et al (1994) Reasons underlying negative mammography in patients with palpable breast cancer. Clin Radiol 49:123\u2013125","journal-title":"Clin Radiol"},{"key":"1523_CR4","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/0959-8049(94)90177-5","volume":"30","author":"H Joensuu","year":"1994","unstructured":"Joensuu H, Asola R, Holli K et al (1994) Delayed diagnosis and large size of breast cancer after a false negative mammogram. Eur J Cancer 30:1299\u20131302","journal-title":"Eur J Cancer"},{"key":"1523_CR5","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1111\/j.1445-2197.1996.tb01140.x","volume":"66","author":"SB Chew","year":"1996","unstructured":"Chew SB, Hughes M, Kennedy C, Gillett D, Carmalt H (1996) Mammographically negative breast cancer at the Strathfield Breast Centre. Aust N Z J Surg 66:134\u2013137","journal-title":"Aust N Z J Surg"},{"key":"1523_CR6","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/S0009-9260(99)91090-5","volume":"54","author":"HA Moss","year":"1999","unstructured":"Moss HA, Britton PD, Flower CD et al (1999) How reliable is modern breast imaging in differentiating benign from malignant breast lesions in a symptomatic population? Clin Radiol 54:676\u2013682","journal-title":"Clin Radiol"},{"key":"1523_CR7","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiol.2251011667","volume":"225","author":"TM Kolb","year":"2002","unstructured":"Kolb TM, Lichy J, Newhouse JH (2002) Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology 225:165\u2013175","journal-title":"Radiology"},{"key":"1523_CR8","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1001\/archinte.163.10.1194","volume":"163","author":"K Flobbe","year":"2003","unstructured":"Flobbe K, Bosch AM, Kessels AG et al (2003) The additional diagnostic value of ultrasonography in the diagnosis of breast cancer. Arch Intern Med 163:1194\u20131199","journal-title":"Arch Intern Med"},{"key":"1523_CR9","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.amjsurg.2004.06.032","volume":"188","author":"SR Benson","year":"2004","unstructured":"Benson SR, Blue J, Judd K, Harman JE (2004) Ultrasound is now better than mammography for the detection of invasive breast cancer. Am J Surg 188:381\u2013385","journal-title":"Am J Surg"},{"key":"1523_CR10","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1148\/radiol.2333031484","volume":"233","author":"WA Berg","year":"2004","unstructured":"Berg WA, Gutierrez L, NessAiver MS, Carter WB, Bhargavan M, Lewis RS, Ioffe OB (2004) Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer. Radiology 233:830\u2013849","journal-title":"Radiology"},{"key":"1523_CR11","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1002\/jso.20801","volume":"96","author":"IG Murphy","year":"2007","unstructured":"Murphy IG, Dillon MF, Doherty AO, McDermott EW, Kelly G, O'Higgins N, Hill AD (2007) Analysis of patients with false negative mammography and symptomatic breast carcinoma. J Surg Oncol 96:457\u2013463","journal-title":"J Surg Oncol"},{"key":"1523_CR12","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1038\/sj.bjc.6600713","volume":"88","author":"PJ Kneeshaw","year":"2003","unstructured":"Kneeshaw PJ, Turnbull LW, Drew PJ (2003) Current applications and future direction of MR mammography. Br J Cancer 88:4\u201310","journal-title":"Br J Cancer"},{"key":"1523_CR13","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1148\/radiol.2443051661","volume":"244","author":"CK Kuhl","year":"2007","unstructured":"Kuhl CK (2007) Current status of breast MR imaging. Part 2. Clinical applications. Radiology 244:672\u2013691","journal-title":"Radiology"},{"key":"1523_CR14","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1200\/JCO.2007.14.3594","volume":"26","author":"S Orel","year":"2008","unstructured":"Orel S (2008) Who should have breast magnetic resonance imaging evaluation? J Clin Oncol 26:703\u201311","journal-title":"J Clin Oncol"},{"key":"1523_CR15","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1053\/j.ro.2007.06.004","volume":"42","author":"CJ D'Orsi","year":"2007","unstructured":"D'Orsi CJ, Newell MS (2007) Digital mammography: clinical implementation and clinical trials. Semin Roentgenol 42:236\u2013242","journal-title":"Semin Roentgenol"},{"key":"1523_CR16","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/j.rcl.2007.06.005","volume":"45","author":"EA Rafferty","year":"2007","unstructured":"Rafferty EA (2007) Digital mammography: novel applications. Radiol Clin North Am 45:831\u2013843","journal-title":"Radiol Clin North Am"},{"key":"1523_CR17","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1056\/NEJMoa052911","volume":"353","author":"ED Pisano","year":"2005","unstructured":"Pisano ED, Gatsonis C, Hendrick E et al (2005) Digital Mammographic Imaging Screening Trial (DMIST) Investigators Group: diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 353:1773\u20131783","journal-title":"N Engl J Med"},{"key":"1523_CR18","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1148\/radiol.2461070200","volume":"246","author":"ED Pisano","year":"2008","unstructured":"Pisano ED, Hendrick RE, Yaffe MJ et al (2008) Diagnostic accuracy of digital versus film mammography: exploratory analysis of selected population subgroups in DMIST. Radiology 246:376\u2013383","journal-title":"Radiology"},{"key":"1523_CR19","doi-asserted-by":"crossref","first-page":"S231","DOI":"10.1148\/rg.27si075511","volume":"27","author":"JM Park","year":"2007","unstructured":"Park JM, Franken EA Jr, Garg M, Fajardo LL, Niklason LT (2007) Breast tomosynthesis: present considerations and future applications. Radiographics 27:S231\u2013S240","journal-title":"Radiographics"},{"key":"1523_CR20","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1053\/j.ro.2007.06.006","volume":"42","author":"JM Lewin","year":"2007","unstructured":"Lewin JM, Niklason L (2007) Advanced applications of digital mammography: breast tomosynthesis and contrast-enhanced digital mammography. Semin Roentgenol 42:243\u2013252","journal-title":"Semin Roentgenol"},{"key":"1523_CR21","doi-asserted-by":"crossref","first-page":"616","DOI":"10.2214\/AJR.07.2231","volume":"189","author":"SP Poplack","year":"2007","unstructured":"Poplack SP, Tosteson TD, Kogel CA, Nagy HM (2007) Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. Am J Roentgenol 189:616\u2013623","journal-title":"Am J Roentgenol"},{"key":"1523_CR22","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1148\/radiology.205.2.9356620","volume":"205","author":"LT Niklason","year":"1997","unstructured":"Niklason LT, Christian BT, Niklason LE et al (1997) Digital breast tomosynthesis in breast imaging. Radiology 205:399\u2013406","journal-title":"Radiology"},{"issue":"4","key":"1523_CR23","doi-asserted-by":"crossref","first-page":"865","DOI":"10.2214\/AJR.07.2841","volume":"190","author":"WF Good","year":"2008","unstructured":"Good WF, Abrams GS, Catullo VJ, Chough DM, Ganott MA, Hakim CM, Gur D (2008) Digital breast tomosynthesis: a pilot observer study. AJR Am J Roentgenol 190(4):865\u2013869","journal-title":"AJR Am J Roentgenol"},{"issue":"12","key":"1523_CR24","doi-asserted-by":"crossref","first-page":"2817","DOI":"10.1007\/s00330-008-1076-9","volume":"18","author":"I Andersson","year":"2008","unstructured":"Andersson I, Ikeda DM, Zackrisson S, Ruschin M, Svahn T, Timberg P, Tingberg A (2008) Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol 18(12):2817\u20132825","journal-title":"Eur Radiol"},{"key":"1523_CR25","volume-title":"Mammography quality control manual","author":"RE Hendrick","year":"1999","unstructured":"Hendrick RE, Bassett L, Botsco MA et al (1999) Mammography quality control manual. American College of Radiology, Reston"},{"key":"1523_CR26","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1148\/radiology.213.1.r99oc3923","volume":"213","author":"JM Boone","year":"1999","unstructured":"Boone JM (1999) Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte Carlo assessment 1. Radiology 213:23\u201337","journal-title":"Radiology"},{"key":"1523_CR27","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/S0033-8389(01)00017-3","volume":"40","author":"L Liberman","year":"2002","unstructured":"Liberman L, Menell JH (2002) Breast imaging reporting and data system (BI-RADS). Radiol Clin North Am 40:409\u2013430","journal-title":"Radiol Clin North Am"},{"key":"1523_CR28","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.rcl.2007.06.003","volume":"45","author":"CJ D'Orsi","year":"2007","unstructured":"D'Orsi CJ, Newell MS (2007) BI-RADS decoded: detailed guidance on potentially confusing issues. Radiol Clin North Am 45:751\u2013763","journal-title":"Radiol Clin North Am"},{"key":"1523_CR29","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.acra.2006.10.022","volume":"14","author":"SC Chen","year":"2007","unstructured":"Chen SC, Carton AK, Albert M, Conant EF, Schnall MD, Maidment AD (2007) Initial clinical experience with contrast-enhanced digital breast tomosynthesis. Acad Radiol 14:229\u2013238","journal-title":"Acad Radiol"},{"key":"1523_CR30","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1007\/s00330-004-2307-3","volume":"14","author":"R Kaas","year":"2004","unstructured":"Kaas R, Kroger R, Hendriks JH et al (2004) The significance of circumscribed malignant mammographic masses in the surveillance of BRCA 1\/2 gene mutation carriers. Eur Radiol 14:1647\u20131653","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1523-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-009-1523-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-009-1523-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T07:54:45Z","timestamp":1559030085000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-009-1523-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,8,6]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["1523"],"URL":"https:\/\/doi.org\/10.1007\/s00330-009-1523-2","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,8,6]]}}}