{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T00:10:38Z","timestamp":1790640638144,"version":"4.1.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2010,6]]},"DOI":"10.1007\/s00330-009-1672-3","type":"journal-article","created":{"date-parts":[[2009,12,15]],"date-time":"2009-12-15T09:34:54Z","timestamp":1260869694000},"page":"1311-1320","source":"Crossref","is-referenced-by-count":103,"title":["Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases"],"prefix":"10.1007","volume":"20","author":[{"given":"Mayil S.","family":"Krishnam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anderanik","family":"Tomasian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sachin","family":"Malik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vibhas","family":"Desphande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerhard","family":"Laub","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan G.","family":"Ruehm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2009,12,16]]},"reference":[{"issue":"6","key":"1672_CR1","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1007\/s10554-006-9204-6","volume":"23","author":"R Gebker","year":"2007","unstructured":"Gebker R, Gomaa O, Schnackenburg B, Rebakowski J, Fleck E, Nagel E (2007) Comparison of different MRI techniques for the assessment of thoracic aortic pathology: 3D contrast enhanced MR angiography, turbo spin-echo and balanced steady state free precession. Int J Cardiovasc Imaging 23(6):747\u2013756","journal-title":"Int J Cardiovasc Imaging"},{"issue":"2","key":"1672_CR2","doi-asserted-by":"crossref","first-page":"522","DOI":"10.2214\/AJR.05.1467","volume":"188","author":"EM Groves","year":"2007","unstructured":"Groves EM, Bireley W, Dill K, Carroll TJ, Carr JC (2007) Quantitative analysis of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta. AJR Am J Roentgenol 188(2):522\u2013528","journal-title":"AJR Am J Roentgenol"},{"key":"1672_CR3","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.2214\/ajr.166.6.8633452","volume":"166","author":"MR Prince","year":"1996","unstructured":"Prince MR, Narasimham DL, Jacoby WT et al (1996) Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta. AJR Am J Roentgenol 166:1387\u20131397","journal-title":"AJR Am J Roentgenol"},{"key":"1672_CR4","doi-asserted-by":"crossref","first-page":"145","DOI":"10.2214\/ajr.173.1.10397116","volume":"173","author":"GA Krinsky","year":"1999","unstructured":"Krinsky GA, Reuss PM, Lee VS et al (1999) Thoracic aorta: comparison of single-dose breath-hold and double-dose non-breath-hold gadolinium-enhanced three-dimensional MR angiography. AJR Am J Roentgenol 173:145\u2013150","journal-title":"AJR Am J Roentgenol"},{"key":"1672_CR5","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1016\/S0733-8651(03)00087-0","volume":"21","author":"LP Lawler","year":"2003","unstructured":"Lawler LP, Fishman EK (2003) Multidetector row computed tomography of the aorta and peripheral arteries. Cardiol Clin 21:607\u2013629","journal-title":"Cardiol Clin"},{"key":"1672_CR6","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.rcl.2005.02.010","volume":"43","author":"C Chiles","year":"2005","unstructured":"Chiles C, Carr JJ (2005) Vascular diseases of the thorax: evaluation with multidetector CT. Radiol Clin North Am 43:543\u2013569","journal-title":"Radiol Clin North Am"},{"issue":"1","key":"1672_CR7","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1148\/radiol.2461071267","volume":"246","author":"E Kanal","year":"2008","unstructured":"Kanal E, Broome DR, Martin DR, Thomsen HS (2008) Response to the FDA\u2019s May 23, 2007, nephrogenic systemic fibrosis update. Radiology 246(1):11\u201314","journal-title":"Radiology"},{"issue":"11","key":"1672_CR8","doi-asserted-by":"crossref","first-page":"3174","DOI":"10.1093\/ndt\/gfm261","volume":"22","author":"P Marckmann","year":"2007","unstructured":"Marckmann P, Skov L, Rossen K, Heaf JG, Thomsen HS (2007) Case-control study of gadodiamide-related nephrogenic systemic fibrosis. Nephrol Dial Transplant 22(11):3174\u20133178","journal-title":"Nephrol Dial Transplant"},{"issue":"1","key":"1672_CR9","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1148\/radiol.2431062144","volume":"243","author":"EA Sadowski","year":"2007","unstructured":"Sadowski EA, Bennett LK, Chan MR et al (2007) Nephrogenic systemic fibrosis: risk factors and incidence estimation. Radiology 243(1):148\u2013157","journal-title":"Radiology"},{"issue":"4","key":"1672_CR10","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1007\/s00330-005-0028-x","volume":"16","author":"V Russo","year":"2006","unstructured":"Russo V, Renzulli M, Buttazzi K, Fattori R (2006) Acquired diseases of the thoracic aorta: role of MRI and MRA. Eur Radiol 16(4):852\u2013865","journal-title":"Eur Radiol"},{"key":"1672_CR11","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/S0720-048X(02)00330-3","volume":"46","author":"F Fuchs","year":"2003","unstructured":"Fuchs F, Laub G, Othomo K (2003) TrueFISP\u2014technical considerations and cardiovascular applications. Eur J Radiol 46:28\u201332","journal-title":"Eur J Radiol"},{"issue":"5","key":"1672_CR12","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/RLI.0b013e31816be927","volume":"43","author":"A Tomasian","year":"2008","unstructured":"Tomasian A, Lohan DG, Laub G, Singhal A, Finn JP, Krishnam MS (2008) Noncontrast 3D steady state free precession magnetic resonance angiography of the thoracic central veins using nonselective radiofrequency excitation over a large field of view: initial experience. Invest Radiol 43(5):306\u2013313","journal-title":"Invest Radiol"},{"issue":"6","key":"1672_CR13","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/RLI.0b013e3181690179","volume":"43","author":"MS Krishnam","year":"2008","unstructured":"Krishnam MS, Tomasian A, Deshpande VS et al (2008) Non-contrast 3D SSFP MR angiography of the whole chest using non-selective RF excitation over a large field of view: comparison with single-phase 3D contrast-enhanced MRA. Invest Radiol 43(6):411\u2013420","journal-title":"Invest Radiol"},{"issue":"5","key":"1672_CR14","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1002\/mrm.1910330515","volume":"33","author":"JH Brittain","year":"1995","unstructured":"Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG (1995) Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med 33(5):689\u2013696","journal-title":"Magn Reson Med"},{"key":"1672_CR15","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1002\/jmri.10106","volume":"15","author":"SM Shea","year":"2002","unstructured":"Shea SM, Deshpande VS, Chung YC (2002) Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation. J Magn Reson Imaging 15:597\u2013602","journal-title":"J Magn Reson Imaging"},{"key":"1672_CR16","unstructured":"Deshpande VS, Krishnam MS, Ruehm SG et al (2006) Non-contrast MR angiography of the heart and great vessels using SSFP with non-selective excitation (abstract). In: Proceedings of the Fourteenth Scientific Meeting of the International Society for Magnetic Resonance in Medicine. International Society for Magnetic Resonance in Medicine, Seattle, p 383"},{"key":"1672_CR17","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202\u20131210","journal-title":"Magn Reson Med"},{"issue":"1","key":"1672_CR18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1064-9689(21)00038-6","volume":"8","author":"GP Reddy","year":"2000","unstructured":"Reddy GP, Higgins CB (2000) MR imaging of the thoracic aorta. Magn Reson Imaging Clin N Am 8(1):1\u201315","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"1672_CR19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0730-725X(95)02045-U","volume":"14","author":"RM Summers","year":"1996","unstructured":"Summers RM, Sostman HD, Spritzer CE et al (1996) Fast spoiled gradient-recalled MR imaging of thoracic aortic dissection: preliminary clinical experience at 1.5 T. Magn Reson Imaging 14:1\u20139","journal-title":"Magn Reson Imaging"},{"key":"1672_CR20","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1097\/RLI.0b013e3180661a77","volume":"42","author":"RM McCarthy","year":"2007","unstructured":"McCarthy RM, Deshpande VS, Beohar N et al (2007) Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease. Invest Radiol 42:665\u2013670","journal-title":"Invest Radiol"},{"key":"1672_CR21","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1148\/radiol.2231010966","volume":"223","author":"FS Pereles","year":"2002","unstructured":"Pereles FS, McCarthy RM, Baskaran V, Carr JC et al (2002) Thoracic aortic dissection and aneurysm: evaluation with non-enhanced TrueFISP MR angiography in less than 4 minutes. Radiology 223:270\u2013274","journal-title":"Radiology"},{"key":"1672_CR22","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1161\/01.CIR.0000134282.35183.AD","volume":"110","author":"TS Sorensen","year":"2004","unstructured":"Sorensen TS, K\u00f6rperich H, Greil GF et al (2004) Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study. Circulation 110:163\u2013169","journal-title":"Circulation"},{"key":"1672_CR23","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1080\/10976640600723706","volume":"8","author":"X Bi","year":"2006","unstructured":"Bi X, Deshpande V, Carr J, Li D (2006) Coronary artery magnetic resonance angiography (MRA): a comparison between the whole-heart and volume targeted methods using a T2-prepared SSFP sequence. J Cardiovasc Magn Reson 8:703\u2013707","journal-title":"J Cardiovasc Magn Reson"},{"issue":"4","key":"1672_CR24","doi-asserted-by":"crossref","first-page":"902","DOI":"10.2214\/AJR.07.2997","volume":"190","author":"CJ Fran\u00e7ois","year":"2008","unstructured":"Fran\u00e7ois CJ, Tuite D, Deshpande V, Jerecic R, Weale P, Carr JC (2008) Unenhanced MA angiography of the thoracic aorta: initial clinical evaluation. AJR Am J Roentgenol 190(4):902\u2013906","journal-title":"AJR Am J Roentgenol"},{"key":"1672_CR25","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.2214\/AJR.05.1012","volume":"186","author":"R Muthupillai","year":"2006","unstructured":"Muthupillai R, Smink J, Hong S, Ravindran R, Lee VV, Flamm SD (2006) SENSE or k-MAG to accelerate free breathing navigator-guided coronary MR angiography. AJR Am J Roentgenol 186:1669\u20131675","journal-title":"AJR Am J Roentgenol"},{"key":"1672_CR26","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","volume":"42","author":"KP Pruessmann","year":"1999","unstructured":"Pruessmann KP, Weiger M, Scheidegger MB, Boesinger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952\u2013962","journal-title":"Magn Reson Med"},{"key":"1672_CR27","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1002\/mrm.20713","volume":"54","author":"P Kellman","year":"2005","unstructured":"Kellman P, McVeigh ER (2005) Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med 54:1439\u20131447","journal-title":"Magn Reson Med"},{"key":"1672_CR28","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1148\/rg.255045202","volume":"25","author":"JF Glockner","year":"2005","unstructured":"Glockner JF, Hu HH, Stanley DW, Angelos L, King K (2005) Parallel MR imaging: a user\u2019s guide. Radiographics 25:1279\u20131297","journal-title":"Radiographics"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.springerlink.com\/index\/pdf\/10.1007\/s00330-009-1672-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T22:44:26Z","timestamp":1634337866000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-009-1672-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12,16]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2010,6]]}},"alternative-id":["1672"],"URL":"https:\/\/doi.org\/10.1007\/s00330-009-1672-3","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,12,16]]}}}