{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T12:44:03Z","timestamp":1762605843457},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2010,5,1]],"date-time":"2010-05-01T00:00:00Z","timestamp":1272672000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2010,9]]},"DOI":"10.1007\/s00330-010-1782-y","type":"journal-article","created":{"date-parts":[[2010,4,30]],"date-time":"2010-04-30T11:58:53Z","timestamp":1272628733000},"page":"2100-2107","source":"Crossref","is-referenced-by-count":32,"title":["Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study"],"prefix":"10.1007","volume":"20","author":[{"given":"Selma","family":"Uysal Ramadan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P\u0131nar","family":"Kosar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iclal","family":"Sonmez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sevilay","family":"Karahan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ugur","family":"Kosar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,5,1]]},"reference":[{"key":"1782_CR1","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1148\/radiol.2213010473","volume":"221","author":"V Raptopoulos","year":"2001","unstructured":"Raptopoulos V, Boiselle PM (2001) Multi-detector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT. Radiology 221:606\u2013613","journal-title":"Radiology"},{"key":"1782_CR2","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1148\/radiol.2222001802","volume":"222","author":"UJ Schoepf","year":"2002","unstructured":"Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483\u2013490","journal-title":"Radiology"},{"key":"1782_CR3","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1136\/emj.2005.029397","volume":"23","author":"K Hogg","year":"2006","unstructured":"Hogg K, Brown G, Dunning J et al (2006) Diagnosis of pulmonary embolism with CT pulmonary angiography: a systematic review. Emerg Med J 23:172\u2013178","journal-title":"Emerg Med J"},{"key":"1782_CR4","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1148\/radiol.2422052132","volume":"242","author":"KT Bae","year":"2007","unstructured":"Bae KT, Tao C, G\u00fcrel S et al (2007) Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography. Radiology 242:582\u2013589","journal-title":"Radiology"},{"key":"1782_CR5","doi-asserted-by":"crossref","first-page":"313","DOI":"10.2214\/AJR.06.0078","volume":"188","author":"CH Lee","year":"2007","unstructured":"Lee CH, Goo JM, Lee HJ, Kim KG, Im J, Bae KT (2007) Determination of optimal timing window for pulmonary artery MDCT angiography. AJR Am J Roentgenol 188:313\u2013317","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR6","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.2214\/AJR.05.0714","volume":"187","author":"H Schoellnast","year":"2006","unstructured":"Schoellnast H, Deutschmann HA, Berghold A, Fritz GA, Schaffer GJ, Tillich M (2006) MDCT angiography of the pulmonary arteries: influence of body weight, body mass index, and scan length on arterial enhancement at different iodine flow rate. AJR Am J Roentgenol 187:1074\u20131078","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR7","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/S0899-7071(98)00068-0","volume":"22","author":"DF Yankelevitz","year":"1998","unstructured":"Yankelevitz DF, Shaham D, Shah A, Rademacker J, Henschke CI (1998) Optimization of contrast delivery for pulmonary CT angiography. Clin Imaging 22:398\u2013403","journal-title":"Clin Imaging"},{"key":"1782_CR8","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0363-0188(02)00006-3","volume":"32","author":"L Washington","year":"2003","unstructured":"Washington L, Gulsun M (2003) CT for thromboembolic disease. Curr Probl Diagn Radiol 32:105\u2013126","journal-title":"Curr Probl Diagn Radiol"},{"key":"1782_CR9","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1148\/radiol.2302021489","volume":"230","author":"UJ Schoepf","year":"2004","unstructured":"Schoepf UJ, Costello P (2004) CT angiography for diagnosis of pulmonary embolism: state of the art. Radiology 230:329\u2013337","journal-title":"Radiology"},{"key":"1782_CR10","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1148\/radiology.217.2.r00nv01447","volume":"217","author":"SD Qanadli","year":"2000","unstructured":"Qanadli SD, Hajjam ME, Mesurolle B et al (2000) Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients. Radiology 217:447\u2013455","journal-title":"Radiology"},{"key":"1782_CR11","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1148\/radiology.219.3.r01jn32629","volume":"219","author":"B Ghaye","year":"2001","unstructured":"Ghaye B, Szapiro D, Mastora I et al (2001) Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis? Radiology 219:629\u2013636","journal-title":"Radiology"},{"key":"1782_CR12","doi-asserted-by":"crossref","first-page":"1971","DOI":"10.1007\/s00330-002-1485-0","volume":"12","author":"M Remy-Jardin","year":"2002","unstructured":"Remy-Jardin M, Tillie-Leblond I, Szapiro D et al (2002) CT angiography of pulmonary embolism in patients with underlying respiratory disease: impact of multislice CT on image quality and negative predictive value. Eur Radiol 12:1971\u20131978","journal-title":"Eur Radiol"},{"key":"1782_CR13","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1148\/radiol.2232010913","volume":"223","author":"I Tilie-Leblond","year":"2002","unstructured":"Tilie-Leblond I, Mastora I, Radenne F et al (2002) Risk of pulmonary embolism after a negative spiral CT angiogram in patients with pulmonary disease: 1-year clinical follow-up study. Radiology 223:461\u2013467","journal-title":"Radiology"},{"key":"1782_CR14","doi-asserted-by":"crossref","unstructured":"Kubo S, Tadamura E, Yamamuro M et al (2006) Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material. AJR Am J Roentgenol 187:548\u2013554","DOI":"10.2214\/AJR.05.0309"},{"key":"1782_CR15","doi-asserted-by":"crossref","first-page":"2716","DOI":"10.1007\/s00330-008-1114-7","volume":"18","author":"AK Andreou","year":"2008","unstructured":"Andreou AK, Curtin JJ, Wilde A, Clark A (2008) Does pregnancy affect vascular enhancement in patients undergoing CT pulmonary angiography? Eur Radiol 18:2716\u20132722","journal-title":"Eur Radiol"},{"key":"1782_CR16","doi-asserted-by":"crossref","first-page":"2705","DOI":"10.1007\/s00330-008-1158-8","volume":"18","author":"C Schaefer-Prokop","year":"2008","unstructured":"Schaefer-Prokop C, Prokop M (2008) CTPA for the diagnosis of acute pulmonary embolism during pregnancy. Eur Radiol 18:2705\u20132708","journal-title":"Eur Radiol"},{"key":"1782_CR17","doi-asserted-by":"crossref","first-page":"2709","DOI":"10.1007\/s00330-008-1100-0","volume":"18","author":"JM U-King-Im","year":"2008","unstructured":"U-King-Im JM, Freeman SJ, Boylan T, Cheow HK (2008) Quality of CT pulmonary angiography for suspected pulmonary embolus in pregnancy. Eur Radiol 18:2709\u20132715","journal-title":"Eur Radiol"},{"key":"1782_CR18","doi-asserted-by":"crossref","first-page":"W351","DOI":"10.2214\/AJR.07.3402","volume":"190","author":"D Roggenland","year":"2008","unstructured":"Roggenland D, Peters SA, Lemburg SP, Holland-Letz T, Nicolas V, Heyer CM (2008) CT angiography in suspected pulmonary embolism: impact of patient characteristics and different venous lines on vessel enhancement and image quality. AJR Am J Roentgenol 190:W351\u2013W359","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR19","doi-asserted-by":"crossref","first-page":"156","DOI":"10.2214\/AJR.06.1240","volume":"189","author":"H Arakawa","year":"2007","unstructured":"Arakawa H, Kohno T, Hiki T, Kaji Y (2007) CT pulmonary angiography and CT venography: factors associated with vessel enhancement. AJR Am J Roentgenol 189:156\u2013161","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR20","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/00004728-200201000-00004","volume":"26","author":"IJ Hartmann","year":"2002","unstructured":"Hartmann IJ, Lo RT, Bakker J, de Monye W, van Waes PF, Pattynama PM (2002) Optimal scan delay in spiral CT for the diagnosis of acute pulmonary embolism. J Comput Assist Tomogr 26:21\u201325","journal-title":"J Comput Assist Tomogr"},{"key":"1782_CR21","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1148\/radiology.207.3.9609886","volume":"207","author":"KT Bae","year":"1998","unstructured":"Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part 1. Prediction with a computer model. Radiology 207:647\u2013655","journal-title":"Radiology"},{"key":"1782_CR22","doi-asserted-by":"crossref","first-page":"623","DOI":"10.2214\/ajr.184.2.01840623","volume":"184","author":"BA Eyer","year":"2005","unstructured":"Eyer BA, Goodman LR, Washington L (2005) Clinicians\u2019 response to radiologists\u2019 reports of isolated subsegmental pulmonary embolism or inconclusive interpretation of pulmonary embolism using MDCT. AJR Am J Roentgenol 184:623\u2013628","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR23","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1148\/radiol.2341031880","volume":"234","author":"MP Revel","year":"2005","unstructured":"Revel MP, Petrover D, Hernigou A, Lefort C, Meyer G, Frija G (2005) Diagnosis pulmonary embolism with four-detector row helical CT: prospective evaluation of 216 outpatients and inpatients. Radiology 234:265\u2013273","journal-title":"Radiology"},{"key":"1782_CR24","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1148\/radiol.2222001802","volume":"222","author":"UJ Schoep","year":"2002","unstructured":"Schoep UJ, Holzknechnt N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483\u2013490","journal-title":"Radiology"},{"key":"1782_CR25","doi-asserted-by":"crossref","first-page":"429","DOI":"10.2214\/ajr.171.2.9694469","volume":"171","author":"T Kim","year":"1998","unstructured":"Kim T, Murakami T, Takahashi S et al (1998) Effects of injection rates of contrast material on arterial phase hepatic CT. AJR Am J Roentgenol 171:429\u2013432","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR26","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1148\/radiology.214.2.r00fe18363","volume":"214","author":"D Fleischmann","year":"2000","unstructured":"Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 214:363\u2013371","journal-title":"Radiology"},{"key":"1782_CR27","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1148\/radiology.216.3.r00au43872","volume":"216","author":"KT Bae","year":"2000","unstructured":"Bae KT, Tran HQ, Heiken JP (2000) Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model. Radiology 216:872\u2013880","journal-title":"Radiology"},{"key":"1782_CR28","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/S0033-8389(03)00028-9","volume":"41","author":"M Remy-Jardin","year":"2003","unstructured":"Remy-Jardin M, Mastora I, Remy J (2003) Pulmonary embolus imaging with multislice CT. Radiol Clin North Am 41:507\u2013519","journal-title":"Radiol Clin North Am"},{"key":"1782_CR29","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1148\/radiol.2333030668","volume":"233","author":"F Cademartiri","year":"2004","unstructured":"Cademartiri F, Nieman K, van der Lugt A et al (2004) Intravenous contrast material administration at 16\u2013detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817\u2013823","journal-title":"Radiology"},{"key":"1782_CR30","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.2214\/ajr.174.4.1741049","volume":"174","author":"P Haage","year":"2000","unstructured":"Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW (2000) Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174:1049\u20131053","journal-title":"AJR Am J Roentgenol"},{"key":"1782_CR31","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1148\/radiology.205.1.9314997","volume":"205","author":"KD Hopper","year":"1997","unstructured":"Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS (1997) Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205:269\u2013271","journal-title":"Radiology"},{"key":"1782_CR32","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/01.rli.0000091841.45342.84","volume":"39","author":"H Schoellnast","year":"2004","unstructured":"Schoellnast H, Tillich M, Deutschmann MJ, Deutschmann HA, Schaffler GJ, Portugaller HR (2004) Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column. Invest Radiol 39:20\u201326","journal-title":"Invest Radiol"},{"key":"1782_CR33","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.2214\/ajr.184.6.01841935","volume":"184","author":"H Schoellnast","year":"2005","unstructured":"Schoellnast H, Deutschmann HA, Fritz GA, Stessel U, Schaffler GJ, Tillich M (2005) MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization. AJR Am J Roentgenol 184:1935\u20131939","journal-title":"AJR Am J Roentgenol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-010-1782-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-010-1782-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-010-1782-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T11:54:50Z","timestamp":1559044490000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-010-1782-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,5,1]]},"references-count":33,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["1782"],"URL":"https:\/\/doi.org\/10.1007\/s00330-010-1782-y","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,5,1]]}}}