{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T06:22:19Z","timestamp":1791354139697,"version":"4.3.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2012,8,16]],"date-time":"2012-08-16T00:00:00Z","timestamp":1345075200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2013,2]]},"DOI":"10.1007\/s00330-012-2611-2","type":"journal-article","created":{"date-parts":[[2012,8,15]],"date-time":"2012-08-15T13:48:25Z","timestamp":1345038505000},"page":"521-527","source":"Crossref","is-referenced-by-count":29,"title":["Measurement of quantifiable parameters by time-density curves in the elastase-induced aneurysm model: first results in the comparison of a flow diverter and a conventional aneurysm stent"],"prefix":"10.1007","volume":"23","author":[{"given":"Tobias","family":"Struffert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabine","family":"Ott","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Kowarschik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederik","family":"Bender","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edyta","family":"Adamek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Engelhorn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"G\u00f6litz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Lang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles M.","family":"Strother","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnd","family":"Doerfler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2012,8,16]]},"reference":[{"key":"2611_CR1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.4065\/70.2.153","volume":"70","author":"FB Meyer","year":"1995","unstructured":"Meyer FB, Morita A, Puumala MR, Nichols DA (1995) Medical and surgical management of intracranial aneurysms. Mayo Clin Proc 70:153\u2013172","journal-title":"Mayo Clin Proc"},{"key":"2611_CR2","doi-asserted-by":"crossref","first-page":"515","DOI":"10.3171\/jns.1992.77.4.0515","volume":"77","author":"G Guglielmi","year":"1992","unstructured":"Guglielmi G, Vi\u00f1uela F, Duckwiler G et al (1992) Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 77:515\u2013524","journal-title":"J Neurosurg"},{"key":"2611_CR3","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1016\/S0140-6736(02)11314-6","volume":"360","author":"A Molyneux","year":"2002","unstructured":"Molyneux A, Kerr R, Stratton I et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267\u20131274","journal-title":"Lancet"},{"key":"2611_CR4","first-page":"1223","volume":"15","author":"G Geremia","year":"1994","unstructured":"Geremia G, Haklin M, Brennecke L (1994) Embolization of experimentally created aneurysms with intravascular stent devices. AJNR Am J Neuroradiol 15:1223\u20131231","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR5","first-page":"493","volume":"15","author":"AK Wakhloo","year":"1994","unstructured":"Wakhloo AK, Schellhammer F, de Vries J, Haberstroh J, Schumacher M (1994) Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. AJNR Am J Neuroradiol 15:493\u2013502","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR6","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1148\/radiology.191.2.8153318","volume":"191","author":"MP Marks","year":"1994","unstructured":"Marks MP, Dake MD, Steinberg GK, Norbash AM, Lane B (1994) Stent placement for arterial and venous cerebrovascular disease: preliminary experience. Radiology 191:441\u2013446","journal-title":"Radiology"},{"key":"2611_CR7","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1007\/BF02684187","volume":"25","author":"BB Lieber","year":"1997","unstructured":"Lieber BB, Stancampiano AP, Wakhloo AK (1997) Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann Biomed Eng 25:460\u2013469","journal-title":"Ann Biomed Eng"},{"key":"2611_CR8","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1097\/00006123-199808000-00126","volume":"43","author":"AK Wakhloo","year":"1998","unstructured":"Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN (1998) Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery 43:377\u2013379","journal-title":"Neurosurgery"},{"key":"2611_CR9","doi-asserted-by":"crossref","first-page":"onsE313","DOI":"10.1227\/01.NEU.0000383875.08681.23","volume":"67","author":"D Fiorella","year":"2010","unstructured":"Fiorella D, Hsu D, Woo RW, Tarr HH, Nelson PK (2010) Very late thrombosis of a pipeline embolization device construct: case report. Neurosurgery 67:onsE313\u2013onsE314","journal-title":"Neurosurgery"},{"key":"2611_CR10","doi-asserted-by":"crossref","first-page":"2247","DOI":"10.1161\/STROKEAHA.110.589911","volume":"41","author":"B Lubicz","year":"2010","unstructured":"Lubicz B, Collignon L, Raphaeli G et al (2010) Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41:2247\u20132253","journal-title":"Stroke"},{"key":"2611_CR11","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3174\/ajnr.A2339","volume":"32","author":"Z Kulcs\u00e1r","year":"2011","unstructured":"Kulcs\u00e1r Z, Houdart E, Bonaf\u00e9 A et al (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32:20\u201325","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR12","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s00234-010-0676-7","volume":"53","author":"B Turowski","year":"2011","unstructured":"Turowski B, Macht S, Kulcs\u00e1r Z, H\u00e4nggi D, Stummer W (2011) Early fatal haemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-stent): do we need to rethink our concepts? Neuroradiology 53:37\u201341","journal-title":"Neuroradiology"},{"key":"2611_CR13","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1177\/159101991001600204","volume":"16","author":"CJ O\u2019kelly","year":"2010","unstructured":"O\u2019kelly CJ, Krings T, Fiorella D, Marotta TR (2010) A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 16:133\u2013137","journal-title":"Interv Neuroradiol"},{"key":"2611_CR14","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s00234-010-0767-5","volume":"53","author":"M Kamran","year":"2011","unstructured":"Kamran M, Yarnold J, Grunwald IQ, Byrne JV (2011) Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schema. Neuroradiology 53:501\u2013508","journal-title":"Neuroradiology"},{"key":"2611_CR15","first-page":"1214","volume":"23","author":"C Sadasivan","year":"2002","unstructured":"Sadasivan C, Lieber BB, Gounis MJ, Lopes DK, Hopkins LN (2002) Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement. AJNR Am J Neuroradiol 23:1214\u20131221","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR16","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1109\/TMI.2008.2012162","volume":"28","author":"C Sadasivan","year":"2009","unstructured":"Sadasivan C, Cesar L, Seong J, Wakhloo AK, Lieber BB (2009) Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography. IEEE Trans Med Imaging 28:1117\u20131125","journal-title":"IEEE Trans Med Imaging"},{"key":"2611_CR17","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.3174\/ajnr.A1586","volume":"30","author":"AS Ahmed","year":"2009","unstructured":"Ahmed AS, Deuerling-Zheng Y, Strother CM et al (2009) Impact of intra-arterial injection parameters on arterial, capillary, and venous time-concentration curves in a canine model. AJNR Am J Neuroradiol 30:1337\u20131341","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR18","doi-asserted-by":"crossref","first-page":"919","DOI":"10.3174\/ajnr.A2020","volume":"31","author":"CM Strother","year":"2010","unstructured":"Strother CM, Bender F, Deuerling-Zheng Y et al (2010) Parametric color coding of digital subtraction angiography. AJNR Am J Neuroradiol 31:919\u2013924","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR19","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1148\/radiology.213.1.r99oc15223","volume":"213","author":"HJ Cloft","year":"1999","unstructured":"Cloft HJ, Altes TA, Marx WF et al (1999) Endovascular creation of an in vivo bifurcation aneurysm model in rabbits. Radiology 213:223\u2013228","journal-title":"Radiology"},{"key":"2611_CR20","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1148\/radiology.213.1.r99oc16217","volume":"213","author":"DF Kallmes","year":"1999","unstructured":"Kallmes DF, Helm GA, Hudson SB et al (1999) Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits. Radiology 213:217\u2013222","journal-title":"Radiology"},{"key":"2611_CR21","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s00234-008-0392-8","volume":"50","author":"C Roth","year":"2008","unstructured":"Roth C, Struffert T, Grunwald IQ et al (2008) Long-term results with Matrix coils vs GDC: an angiographic and histopathological comparison. Neuroradiology 50:693\u2013699","journal-title":"Neuroradiology"},{"key":"2611_CR22","doi-asserted-by":"crossref","first-page":"77","DOI":"10.3171\/JNS\/2008\/109\/7\/0077","volume":"109","author":"T Struffert","year":"2008","unstructured":"Struffert T, Roth C, Romeike B et al (2008) Onyx in an experimental aneurysm model: histological and angiographic results. J Neurosurg 109:77\u201382","journal-title":"J Neurosurg"},{"key":"2611_CR23","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1227\/01.NEU.0000180037.43693.fe","volume":"57","author":"IQ Grunwald","year":"2005","unstructured":"Grunwald IQ, Romeike BF, Roth C et al (2005) Anticoagulation regimes and their influence on the occlusion rate of aneurysms: an experimental study in rabbits. Neurosurgery 57:1048\u20131055","journal-title":"Neurosurgery"},{"key":"2611_CR24","doi-asserted-by":"crossref","first-page":"595","DOI":"10.3174\/ajnr.A2324","volume":"32","author":"Z Zeng","year":"2011","unstructured":"Zeng Z, Kallmes DF, Durka MJ et al (2011) Hemodynamics and anatomy of elastase-induced rabbit aneurysm models: similarity to human cerebral aneurysms? AJNR Am J Neuroradiol 32:595\u2013601","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR25","doi-asserted-by":"crossref","first-page":"2346","DOI":"10.1161\/STROKEAHA.106.479576","volume":"38","author":"DF Kallmes","year":"2007","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ (2007) A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 38:2346\u20132352","journal-title":"Stroke"},{"key":"2611_CR26","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.3174\/ajnr.A1530","volume":"30","author":"DF Kallmes","year":"2009","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ (2009) A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms. AJNR Am J Neuroradiol 30:1153\u20131158","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR27","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.3174\/ajnr.A2056","volume":"31","author":"Y Ding","year":"2010","unstructured":"Ding Y, Dai D, Kadirvel R, Lewis DA, Kallmes DF (2010) Five-year follow-up in elastase-induced aneurysms in rabbits. AJNR Am J Neuroradiol 31:1236\u20131239","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR28","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1177\/159101990601200104","volume":"12","author":"IQ Grunwald","year":"2006","unstructured":"Grunwald IQ, Romeike B, Eymann R, Roth C, Struffert T, Reith W (2006) An experimental aneurysm model: a training model for neurointerventionalists. Interv Neuroradiol 12:17\u201324","journal-title":"Interv Neuroradiol"},{"key":"2611_CR29","doi-asserted-by":"crossref","first-page":"418","DOI":"10.3174\/ajnr.A1853","volume":"31","author":"F Bouzeghrane","year":"2010","unstructured":"Bouzeghrane F, Naggara O, Kallmes DF, Berenstein A, Raymond J (2010) International consortium of neuroendovascular centres. In vivo experimental intracranial aneurysm models: a systematic review. AJNR Am J Neuroradiol 31:418\u201323","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR30","first-page":"6916OP","volume":"6916","author":"A Dohatcu","year":"2008","unstructured":"Dohatcu A, Ionita CN, Paciorek A, Bednarek DR, Hoffmann KR, Rudin S (2008) Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology. Proc Soc Photo Opt Instrum Eng 6916:6916OP","journal-title":"Proc Soc Photo Opt Instrum Eng"},{"key":"2611_CR31","doi-asserted-by":"crossref","first-page":"891","DOI":"10.3171\/jns.2005.103.5.0891","volume":"103","author":"G Cant\u00f3n","year":"2005","unstructured":"Cant\u00f3n G, Levy DI, Lasheras JC, Nelson PK (2005) Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg 103:891\u2013902","journal-title":"J Neurosurg"},{"key":"2611_CR32","doi-asserted-by":"crossref","first-page":"27","DOI":"10.3174\/ajnr.A2274","volume":"32","author":"JR Cebral","year":"2011","unstructured":"Cebral JR, Mut F, Raschi M et al (2011) Aneurysm rupture following treatment with flow-diverting stents: computational haemodynamics analysis of treatment. AJNR Am J Neuroradiol 32:27\u201333","journal-title":"AJNR Am J Neuroradiol"},{"key":"2611_CR33","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1227\/01.NEU.0000223650.11954.6C","volume":"59","author":"D Fiorella","year":"2006","unstructured":"Fiorella D, Albuquerque FC, Deshmukh VR et al (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59:291\u2013300","journal-title":"Neurosurgery"},{"key":"2611_CR34","doi-asserted-by":"crossref","unstructured":"Ediriwickrema A, Williamson T, Hebert R, Matouk C, Johnson MH, Bulsara KR (2012) Intracranial stenting as monotherapy in subarachnoid hemorrhage and sickle cell disease. J Neurointerv Surg. doi: 10.1136\/neurintsurg-2011-010224","DOI":"10.1136\/neurintsurg-2011-010224"},{"key":"2611_CR35","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1227\/01.NEU.0000159887.03290.D1","volume":"56","author":"T Krings","year":"2005","unstructured":"Krings T, Hans FJ, M\u00f6ller-Hartmann W et al (2005) Treatment of experimentally induced aneurysms with stents. Neurosurgery 56:1347\u20131359","journal-title":"Neurosurgery"},{"key":"2611_CR36","doi-asserted-by":"crossref","first-page":"3171","DOI":"10.1088\/0031-9155\/50\/13\/014","volume":"50","author":"ZJ Wang","year":"2005","unstructured":"Wang ZJ, Hoffmann KR, Wang Z, Rudin S, Guterman LR, Meng H (2005) Contrast settling in cerebral aneurysm angiography. Phys Med Biol 50:3171\u20133181","journal-title":"Phys Med Biol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-012-2611-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-012-2611-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-012-2611-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T08:01:49Z","timestamp":1559030509000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-012-2611-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8,16]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["2611"],"URL":"https:\/\/doi.org\/10.1007\/s00330-012-2611-2","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,8,16]]}}}