{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T22:35:14Z","timestamp":1767825314076,"version":"3.49.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2013,9,13]],"date-time":"2013-09-13T00:00:00Z","timestamp":1379030400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1007\/s00330-013-3012-x","type":"journal-article","created":{"date-parts":[[2013,9,12]],"date-time":"2013-09-12T15:27:21Z","timestamp":1378999641000},"page":"595-602","source":"Crossref","is-referenced-by-count":84,"title":["Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysis"],"prefix":"10.1007","volume":"24","author":[{"given":"Junqiang","family":"Lei","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yinzhong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kehu","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,9,13]]},"reference":[{"key":"3012_CR1","unstructured":"Breast Cancer (2009) Breast Cancer in Young Women WebMD. Retrieved 9 September 2009. Available from www.webmd.com\/breast-cancer\/guide\/breast-cancer-young-women"},{"key":"3012_CR2","doi-asserted-by":"crossref","first-page":"e337","DOI":"10.5301\/JBM.2012.10370","volume":"27","author":"LW Chow","year":"2012","unstructured":"Chow LW, Yip AY, Ng EL (2012) Prevention of oncological diseases: primary and secondary prevention. Int J Biol Markers 27:e337\u2013e343","journal-title":"Int J Biol Markers"},{"key":"3012_CR3","doi-asserted-by":"crossref","first-page":"2817","DOI":"10.1007\/s00330-008-1076-9","volume":"18","author":"I Andersson","year":"2008","unstructured":"Andersson I, Ikeda DM, Zackrisson S et al (2008) Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur Radiol 18:2817\u20132825","journal-title":"Eur Radiol"},{"key":"3012_CR4","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1258\/ar.2012.120062","volume":"53","author":"P Skaane","year":"2012","unstructured":"Skaane P, Gullien R, Bjorndal H et al (2012) Digital breast tomosynthesis (DBT): initial experience in a clinical setting. Acta Radiol 53:524\u2013529","journal-title":"Acta Radiol"},{"key":"3012_CR5","doi-asserted-by":"crossref","first-page":"5","DOI":"10.2214\/AJR.09.3244","volume":"195","author":"CM Hakim","year":"2010","unstructured":"Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D (2010) Digital breast tomosynthesis in the diagnostic environment: A subjective side-by-side review. Am J Roentgenol 195:5","journal-title":"Am J Roentgenol"},{"key":"3012_CR6","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1007\/s00330-009-1699-5","volume":"20","author":"G Gennaro","year":"2010","unstructured":"Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545\u20131553","journal-title":"Eur Radiol"},{"key":"3012_CR7","doi-asserted-by":"crossref","first-page":"S231","DOI":"10.1148\/rg.27si075511","volume":"1","author":"JM Park","year":"2007","unstructured":"Park JM, Franken EA Jr, Garg M, Fajardo LL, Niklason LT (2007) Breast tomosynthesis: present considerations and future applications. Radiogr Suppl 1:S231\u2013S240","journal-title":"Radiogr Suppl"},{"key":"3012_CR8","author":"F Thibault","year":"2013","unstructured":"Thibault F, Dromain C et al (2013) Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study. Eur Radiol. doi: 10.1007\/s00330-013-2863-5","journal-title":"Eur Radiol"},{"key":"3012_CR9","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s00330-009-1523-2","volume":"20","author":"HJ Teertstra","year":"2010","unstructured":"Teertstra HJ, Loo CE, van den Bosch MA et al (2010) Breast tomosynthesis in clinical practice: initial results. Eur Radiol 20:16\u201324","journal-title":"Eur Radiol"},{"key":"3012_CR10","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1007\/s00330-011-2305-1","volume":"22","author":"A Tagliafico","year":"2012","unstructured":"Tagliafico A, Astengo D, Cavagnetto F, Calabrese M et al (2012) One-to-one comparison between digital spot compression view and digital breast tomosynthesis. Eur Radiol 22:539\u2013544","journal-title":"Eur Radiol"},{"key":"3012_CR11","doi-asserted-by":"crossref","first-page":"4087","DOI":"10.1118\/1.2968098","volume":"35","author":"HP Chan","year":"2008","unstructured":"Chan HP, Wei J, Zhang Y et al (2008) Computer-aided detection of masses in digital tomosynthesis mammography: comparison of three approaches. Med Phys 35:4087\u20134095","journal-title":"Med Phys"},{"key":"3012_CR12","doi-asserted-by":"crossref","first-page":"865","DOI":"10.2214\/AJR.07.2841","volume":"190","author":"WF Good","year":"2008","unstructured":"Good WF, Abrams GS, Catullo VJ et al (2008) Digital breast tomosynthesis: a pilot observer study. Am J Roentgenol 190:865\u2013869","journal-title":"Am J Roentgenol"},{"key":"3012_CR13","doi-asserted-by":"crossref","first-page":"980","DOI":"10.1136\/bmj.315.7114.980","volume":"315","author":"AK Hackshaw","year":"1997","unstructured":"Hackshaw AK, Law MR, Wald NJ (1997) The accumulated evidence on lung cancer and environmental tobacco smoke. BMJ Brit Med J 315:980\u2013988","journal-title":"BMJ Brit Med J"},{"key":"3012_CR14","first-page":"191","volume-title":"System evaluation Guideline","author":"JH Tian","year":"2010","unstructured":"Tian JH (2010) Systematic review of Diagnosis text accuracy. In: Yang KH (ed) System evaluation Guideline. People's Medical Publishing House, Beijin, pp 191\u2013195"},{"key":"3012_CR15","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","volume":"155","author":"PF Whiting","year":"2011","unstructured":"Whiting PF, Rutjes AW, Westwood ME et al (2011) QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155:529\u2013536","journal-title":"Ann Intern Med"},{"key":"3012_CR16","first-page":"97","volume":"8","author":"TS Zhang","year":"2008","unstructured":"Zhang TS, Zhong WZ (2008) Meta-DiSc software in meta-analysis of diagnostic test. J Evid Based Med 8:97\u2013108","journal-title":"J Evid Based Med"},{"key":"3012_CR17","doi-asserted-by":"crossref","first-page":"889","DOI":"10.7326\/0003-4819-149-12-200812160-00008","volume":"149","author":"MM Leeflang","year":"2008","unstructured":"Leeflang MM, Deeks JJ, Gatsonis C, Bossuyt PM (2008) Systematic reviews of diagnostic test accuracy. Ann Intern Med 149:889\u2013897","journal-title":"Ann Intern Med"},{"key":"3012_CR18","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/1471-2288-6-31","volume":"6","author":"J Zamora","year":"2006","unstructured":"Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A (2006) Meta-DiSc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol 6:31","journal-title":"BMC Med Res Methodol"},{"key":"3012_CR19","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ Brit Med J 327:557\u2013560","journal-title":"BMJ Brit Med J"},{"key":"3012_CR20","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1471-2288-11-41","volume":"11","author":"J Bowden","year":"2011","unstructured":"Bowden J, Tierney JF et al (2011) Quantifying, displaying and accounting for heterogeneity in the meta-analysis of RCTs using standard and generalised Q statistics. BMC Med Res Methodol 11:41","journal-title":"BMC Med Res Methodol"},{"key":"3012_CR21","first-page":"2265","volume":"27","author":"PL Liu","year":"2011","unstructured":"Liu PL, Tang SS (2011) Contrast enhanced ultrasound and contrast enhanced CT for diagnosis of focal pancreas lesions: a meta-analysis. Chin J Med Image Technol 27:2265\u20132269","journal-title":"Chin J Med Image Technol"},{"key":"3012_CR22","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/S0895-4356(01)00377-8","volume":"54","author":"JA Sterne","year":"2001","unstructured":"Sterne JA, Egger M (2001) Funnel plots for detecting bias in meta-analysis: guidelines on choice of axis. J Clin Epidemiol 54:1046\u20131055","journal-title":"J Clin Epidemiol"},{"key":"3012_CR23","unstructured":"23 Higgins JPT, Green S (editors) (2011) Chapter 8: assessing risk of bias in included studies. In: Higgins JPT, Green S (eds) Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration. Available from www.cochrane-handbook.org"},{"key":"3012_CR24","doi-asserted-by":"crossref","first-page":"586","DOI":"10.2214\/AJR.08.2031","volume":"193","author":"D Gur","year":"2009","unstructured":"Gur D, Abrams GS, Chough DM et al (2009) Digital breast tomosynthesis: observer performance study. AJR Am J Roentgenol 193:586\u2013591","journal-title":"AJR Am J Roentgenol"},{"key":"3012_CR25","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1016\/j.crad.2012.03.009","volume":"67","author":"MJ Michell","year":"2012","unstructured":"Michell MJ, Iqbal A, Wasan RK et al (2012) comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis. Clin Radiol 67:976\u2013981","journal-title":"Clin Radiol"},{"key":"3012_CR26","doi-asserted-by":"crossref","first-page":"e1074","DOI":"10.1259\/bjr\/53282892","volume":"85","author":"TM Svahn","year":"2012","unstructured":"Svahn TM, Chakraborty DP, Ikeda D et al (2012) Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. Br J Radiol 85:e1074\u2013e1082","journal-title":"Br J Radiol"},{"key":"3012_CR27","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1258\/ar.2010.100262","volume":"52","author":"G Svane","year":"2011","unstructured":"Svane G, Azavedo E, Lindman K et al (2011) Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography. Acta Radiol 52:134\u2013142","journal-title":"Acta Radiol"},{"key":"3012_CR28","doi-asserted-by":"crossref","first-page":"213421","DOI":"10.1155\/2012\/213421","volume":"2012","author":"A Tejerina Bernal","year":"2012","unstructured":"Tejerina Bernal A, Rabadan Doreste F et al (2012) Breast imaging: how we manage diagnostic technology at a multidisciplinary breast center. J Oncol 2012:213421","journal-title":"J Oncol"},{"key":"3012_CR29","first-page":"25","volume":"27","author":"A Smith","year":"2005","unstructured":"Smith A (2005) Full-field breast tomosynthesis. Radiol Manag 27:25\u201331","journal-title":"Radiol Manag"},{"key":"3012_CR30","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/j.rcl.2007.06.005","volume":"45","author":"EA Rafferty","year":"2007","unstructured":"Rafferty EA (2007) Digital mammography: novel applications. Radiol Clin N Am 45:831\u2013843, vii","journal-title":"Radiol Clin N Am"},{"key":"3012_CR31","doi-asserted-by":"crossref","first-page":"616","DOI":"10.2214\/AJR.07.2231","volume":"189","author":"SP Poplack","year":"2007","unstructured":"Poplack SP, Tosteson TD, Kogel CA, Nagy HM (2007) Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. AJR Am J Roentgenol 189:616\u2013623","journal-title":"AJR Am J Roentgenol"},{"key":"3012_CR32","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3109\/02841850903524447","volume":"51","author":"D Fornvik","year":"2010","unstructured":"Fornvik D, Zackrisson S, Ljungberg O et al (2010) Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography. Acta Radiol 51:240\u2013247","journal-title":"Acta Radiol"},{"key":"3012_CR33","doi-asserted-by":"crossref","first-page":"320","DOI":"10.2214\/AJR.10.4656","volume":"196","author":"ML Spangler","year":"2011","unstructured":"Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol 196:320\u2013324","journal-title":"AJR Am J Roentgenol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-013-3012-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-013-3012-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-013-3012-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T12:02:03Z","timestamp":1559044923000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-013-3012-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,13]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["3012"],"URL":"https:\/\/doi.org\/10.1007\/s00330-013-3012-x","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,13]]}}}