{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T02:56:10Z","timestamp":1772160970505,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2014,12,24]],"date-time":"2014-12-24T00:00:00Z","timestamp":1419379200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2015,4]]},"DOI":"10.1007\/s00330-014-3470-9","type":"journal-article","created":{"date-parts":[[2014,12,23]],"date-time":"2014-12-23T05:43:43Z","timestamp":1419313423000},"page":"1059-1067","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Influence of field strength, coil type and image resolution on assessment of synovitis by unenhanced MRI \u2013 a comparison with contrast-enhanced MRI"],"prefix":"10.1007","volume":"25","author":[{"given":"Iris","family":"Eshed","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Krabbe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikkel","family":"\u00d8stergaard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pernille","family":"B\u00f8yesen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakob M.","family":"M\u00f8ller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Flemming","family":"Therkildsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ole Rintek","family":"Madsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mette","family":"Axelsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susanne Juhl","family":"Pedersen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,12,24]]},"reference":[{"key":"3470_CR1","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.berh.2008.09.014","volume":"22","author":"M Ostergaard","year":"2008","unstructured":"Ostergaard M, Pedersen SJ, Dohn UM (2008) Imaging in rheumatoid arthritis\u2013status and recent advances for magnetic resonance imaging, ultrasonography, computed tomography and conventional radiography. Best Pract Res Clin Rheumatol 22:1019\u20131044","journal-title":"Best Pract Res Clin Rheumatol"},{"key":"3470_CR2","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/BF00243060","volume":"21","author":"CG Whitten","year":"1992","unstructured":"Whitten CG, Moore TE, Yuh WT, Kathol MH, Renfrew DL, Walker CW (1992) The use of intravenous gadopentetate dimeglumine in magnetic resonance imaging of synovial lesions. Skelet Radiol 21:215\u2013218","journal-title":"Skelet Radiol"},{"key":"3470_CR3","first-page":"1364","volume":"30","author":"C Peterfy","year":"2003","unstructured":"Peterfy C, Edmonds J, Lassere M, Conaghan P, Ostergaard M, McQueen F et al (2003) OMERACT rheumatoid arthritis MRI studies module. J Rheumatol 30:1364\u20131365","journal-title":"J Rheumatol"},{"key":"3470_CR4","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1111\/j.1749-6632.2009.04382.x","volume":"1154","author":"FM McQueen","year":"2009","unstructured":"McQueen FM (2009) The MRI view of synovitis and tenosynovitis in inflammatory arthritis: implications for diagnosis and management. Ann N Y Acad Sci 1154:21\u201334","journal-title":"Ann N Y Acad Sci"},{"key":"3470_CR5","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1177\/0284185113492651","volume":"54","author":"HS Thomsen","year":"2013","unstructured":"Thomsen HS (2013) Non-renal adverse reactions to contrast media: separating fact from myth. Acta Radiol 54:835\u2013836","journal-title":"Acta Radiol"},{"key":"3470_CR6","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.mri.2012.06.025","volume":"31","author":"RC Semelka","year":"2013","unstructured":"Semelka RC, Hernandes Mde A, Stallings CG, Castillo M (2013) Objective evaluation of acute adverse events and image quality of gadolinium-based contrast agents (gadobutrol and gadobenate dimeglumine) by blinded evaluation. Pilot study. Magn Reson Imaging 31:96\u2013101","journal-title":"Magn Reson Imaging"},{"key":"3470_CR7","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.ejrad.2010.12.104","volume":"80","author":"HS Thomsen","year":"2011","unstructured":"Thomsen HS (2011) Contrast media safety-an update. Eur J Radiol 80:77\u201382","journal-title":"Eur J Radiol"},{"key":"3470_CR8","doi-asserted-by":"crossref","first-page":"358","DOI":"10.3109\/s10165-009-0172-2","volume":"19","author":"T Suzuki","year":"2009","unstructured":"Suzuki T, Ito S, Handa S, Kose K, Okamoto Y, Minami M et al (2009) A new low-field extremity magnetic resonance imaging and proposed compact MRI score: evaluation of anti-tumor necrosis factor biologics on rheumatoid arthritis. Mod Rheumatol 19:358\u2013365","journal-title":"Mod Rheumatol"},{"key":"3470_CR9","doi-asserted-by":"crossref","first-page":"937","DOI":"10.2214\/ajr.182.4.1820937","volume":"182","author":"B Taouli","year":"2004","unstructured":"Taouli B, Zaim S, Peterfy CG, Lynch JA, Stork A, Guermazi A et al (2004) Rheumatoid arthritis of the hand and wrist: comparison of three imaging techniques. AJR Am J Roentgenol 182:937\u2013943","journal-title":"AJR Am J Roentgenol"},{"key":"3470_CR10","doi-asserted-by":"crossref","first-page":"1806","DOI":"10.3899\/jrheum.090350","volume":"36","author":"M Ostergaard","year":"2009","unstructured":"Ostergaard M, Conaghan PG, O'Connor P, Szkudlarek M, Klarlund M, Emery P et al (2009) Reducing invasiveness, duration, and cost of magnetic resonance imaging in rheumatoid arthritis by omitting intravenous contrast injection \u2013 does it change the assessment of inflammatory and destructive joint changes by the OMERACT RAMRIS? J Rheumatol 36:1806\u20131810","journal-title":"J Rheumatol"},{"key":"3470_CR11","first-page":"1385","volume":"30","author":"M Ostergaard","year":"2003","unstructured":"Ostergaard M, Peterfy C, Conaghan P, McQueen F, Bird P, Ejbjerg B et al (2003) OMERACT rheumatoid arthritis magnetic resonance imaging studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system. J Rheumatol 30:1385\u20131386","journal-title":"J Rheumatol"},{"key":"3470_CR12","first-page":"1380","volume":"30","author":"P Bird","year":"2003","unstructured":"Bird P, Ejbjerg B, McQueen F, Ostergaard M, Lassere M, Edmonds J (2003) OMERACT rheumatoid arthritis magnetic resonance imaging studies. Exercise 5: an international multicenter reliability study using computerized MRI erosion volume measurements. J Rheumatol 30:1380\u20131384","journal-title":"J Rheumatol"},{"key":"3470_CR13","doi-asserted-by":"crossref","first-page":"i23","DOI":"10.1136\/ard.2004.031823","volume":"64","author":"B Ejbjerg","year":"2005","unstructured":"Ejbjerg B, McQueen F, Lassere M, Haavardsholm E, Conaghan P, O'Connor P et al (2005) The EULAR-OMERACT rheumatoid arthritis MRI reference image atlas: the wrist joint. Ann Rheum Dis 64:i23\u2013i47","journal-title":"Ann Rheum Dis"},{"key":"3470_CR14","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1093\/rheumatology\/keu029","volume":"53","author":"S Krabbe","year":"2014","unstructured":"Krabbe S, Eshed I, Pedersen SJ, Boyesen P, Moller JM, Therkildsen F et al (2014) Bone marrow oedema assessment by magnetic resonance imaging in rheumatoid arthritis wrist and metacarpophalangeal joints: the importance of field strength, coil type and image resolution. Rheumatology (Oxford) 53:1446\u20131451","journal-title":"Rheumatology (Oxford)"},{"key":"3470_CR15","first-page":"1366","volume":"30","author":"M Lassere","year":"2003","unstructured":"Lassere M, McQueen F, Ostergaard M, Conaghan P, Shnier R, Peterfy C et al (2003) OMERACT rheumatoid arthritis magnetic resonance imaging studies. Exercise 3: an international multicenter reliability study using the RA-MRI Score. J Rheumatol 30:1366\u20131375","journal-title":"J Rheumatol"},{"key":"3470_CR16","doi-asserted-by":"crossref","first-page":"3860","DOI":"10.1002\/art.21493","volume":"52","author":"EA Haavardsholm","year":"2005","unstructured":"Haavardsholm EA, Ostergaard M, Ejbjerg BJ, Kvan NP, Uhlig TA, Lilleas FG et al (2005) Reliability and sensitivity to change of the OMERACT rheumatoid arthritis magnetic resonance imaging score in a multireader, longitudinal setting. Arthritis Rheum 52:3860\u20133867","journal-title":"Arthritis Rheum"},{"key":"3470_CR17","doi-asserted-by":"crossref","first-page":"654","DOI":"10.3109\/s10165-011-0575-8","volume":"22","author":"M Tamai","year":"2012","unstructured":"Tamai M, Kawakami A, Uetani M, Fukushima A, Arima K, Fujikawa K et al (2012) Magnetic resonance imaging (MRI) detection of synovitis and bone lesions of the wrists and finger joints in early-stage rheumatoid arthritis: comparison of the accuracy of plain MRI-based findings and gadolinium-diethylenetriamine pentaacetic acid-enhanced MRI-based findings. Mod Rheumatol 22:654\u2013658","journal-title":"Mod Rheumatol"},{"key":"3470_CR18","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1055\/s-2005-872338","volume":"9","author":"WB Morrison","year":"2005","unstructured":"Morrison WB (2005) Indirect MR arthrography: concepts and controversies. Semin Musculoskelet Radiol 9:125\u2013134","journal-title":"Semin Musculoskelet Radiol"},{"key":"3470_CR19","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/S1064-9689(21)00595-X","volume":"8","author":"CA Boles","year":"2000","unstructured":"Boles CA, Ward WG Sr (2000) Loose fragments and other debris: miscellaneous synovial and marrow disorders. Magn Reson Imaging Clin N Am 8:371\u2013390","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"3470_CR20","doi-asserted-by":"crossref","first-page":"e68","DOI":"10.2106\/JBJS.L.00334","volume":"95","author":"AK Dewan","year":"2013","unstructured":"Dewan AK, Chhabra AB, Khanna AJ, Anderson MW, Brunton LM (2013) Magnetic resonance imaging of the hand and wrist: techniques and spectrum of disease: AAOS exhibit selection. J Bone Joint Surg Am 95:e68","journal-title":"J Bone Joint Surg Am"},{"key":"3470_CR21","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1002\/art.20135","volume":"50","author":"B Ejbjerg","year":"2004","unstructured":"Ejbjerg B, Narvestad E, Rostrup E, Szkudlarek M, Jacobsen S, Thomsen HS et al (2004) Magnetic resonance imaging of wrist and finger joints in healthy subjects occasionally shows changes resembling erosions and synovitis as seen in rheumatoid arthritis. Arthritis Rheum 50:1097\u20131106","journal-title":"Arthritis Rheum"},{"key":"3470_CR22","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S1064-9689(21)00159-8","volume":"3","author":"JB Kneeland","year":"1995","unstructured":"Kneeland JB (1995) Technical considerations for MR imaging of the hand and wrist. Magn Reson Imaging Clin N Am 3:191\u2013196","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"3470_CR23","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1148\/radiol.2521081507","volume":"251","author":"AM Naraghi","year":"2009","unstructured":"Naraghi AM, White LM, Patel C, Tomlinson G, Keystone EC (2009) Comparison of 1.0-T extremity MR and 1.5-T conventional high-field-strength MR in patients with rheumatoid arthritis. Radiology 251:829\u2013837","journal-title":"Radiology"},{"key":"3470_CR24","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1136\/ard.2004.029850","volume":"64","author":"BJ Ejbjerg","year":"2005","unstructured":"Ejbjerg BJ, Narvestad E, Jacobsen S, Thomsen HS, Ostergaard M (2005) Optimised, low cost, low field dedicated extremity MRI is highly specific and sensitive for synovitis and bone erosions in rheumatoid arthritis wrist and finger joints: comparison with conventional high field MRI and radiography. Ann Rheum Dis 64:1280\u20131287","journal-title":"Ann Rheum Dis"},{"key":"3470_CR25","doi-asserted-by":"crossref","first-page":"89","DOI":"10.3109\/03009742.2011.608375","volume":"41","author":"MB Axelsen","year":"2012","unstructured":"Axelsen MB, Stoltenberg M, Poggenborg RP, Kubassova O, Boesen M, Bliddal H et al (2012) Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology. Scand J Rheumatol 41:89\u201394","journal-title":"Scand J Rheumatol"},{"key":"3470_CR26","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1093\/rheumatology\/ker220","volume":"51","author":"M Boesen","year":"2012","unstructured":"Boesen M, Kubassova O, Bouert R, Axelsen MB, Ostergaard M, Cimmino MA et al (2012) Correlation between computer-aided dynamic gadolinium-enhanced MRI assessment of inflammation and semi-quantitative synovitis and bone marrow oedema scores of the wrist in patients with rheumatoid arthritis--a cohort stud. Rheumatology (Oxford) 51:134\u2013143","journal-title":"Rheumatology (Oxford)"},{"key":"3470_CR27","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1148\/rg.275065204","volume":"27","author":"MM Barth","year":"2007","unstructured":"Barth MM, Smith MP, Pedrosa I, Lenkinski RE, Rofsky NM (2007) Body MR imaging at 3.0 T: understanding the opportunities and challenges. Radiographics 27:1445\u20131462, discussion 1462-4","journal-title":"Radiographics"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-014-3470-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-014-3470-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-014-3470-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,24]],"date-time":"2022-04-24T20:40:45Z","timestamp":1650832845000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-014-3470-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,24]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,4]]}},"alternative-id":["3470"],"URL":"https:\/\/doi.org\/10.1007\/s00330-014-3470-9","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,24]]}}}