{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T06:07:49Z","timestamp":1789625269456,"version":"build-2803163510"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2015,2,24]],"date-time":"2015-02-24T00:00:00Z","timestamp":1424736000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2015,7]]},"DOI":"10.1007\/s00330-015-3607-5","type":"journal-article","created":{"date-parts":[[2015,2,23]],"date-time":"2015-02-23T03:48:12Z","timestamp":1424663292000},"page":"1975-1983","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":55,"title":["MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?"],"prefix":"10.1007","volume":"25","author":[{"given":"Tomas","family":"Jurencak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakub","family":"Turek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastiaan L. J. H.","family":"Kietselaer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Casper","family":"Mihl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madeleine","family":"Kok","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent G. V. A.","family":"van Ommen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leen A. F. M.","family":"van Garsse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Estelle C.","family":"Nijssen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joachim E.","family":"Wildberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Das","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,2,24]]},"reference":[{"issue":"4","key":"3607_CR1","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1016\/j.jacc.2003.11.026","volume":"43","author":"A Cribier","year":"2004","unstructured":"Cribier A, Eltchaninoff H, Tron C et al (2004) Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. J Am Coll Cardiol 43(4):698\u2013703","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"3607_CR2","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jacc.2007.04.047","volume":"50","author":"E Grube","year":"2007","unstructured":"Grube E, Schuler G, Buellesfeld L et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 50(1):69\u201376","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"3607_CR3","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1161\/CIRCULATIONAHA.105.582882","volume":"113","author":"JG Webb","year":"2006","unstructured":"Webb JG, Chandavimol M, Thompson CR et al (2006) Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 113(6):842\u2013850","journal-title":"Circulation"},{"issue":"7","key":"3607_CR4","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1161\/CIRCULATIONAHA.107.698258","volume":"116","author":"JG Webb","year":"2007","unstructured":"Webb JG, Pasupati S, Humphries K et al (2007) Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation 116(7):755\u2013763","journal-title":"Circulation"},{"issue":"2","key":"3607_CR5","first-page":"297","volume":"49","author":"LG Svensson","year":"2008","unstructured":"Svensson LG (2008) Aortic valve stenosis and regurgitation: an overview of management. J Cardiovasc Surg 49(2):297\u2013303","journal-title":"J Cardiovasc Surg"},{"issue":"4","key":"3607_CR6","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.jcmg.2011.01.014","volume":"4","author":"J Leipsic","year":"2011","unstructured":"Leipsic J, Gurvitch R, Labounty TM et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4(4):416\u2013429","journal-title":"JACC Cardiovasc Imaging"},{"issue":"3","key":"3607_CR7","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.jacc.2009.06.063","volume":"55","author":"D Messika-Zeitoun","year":"2010","unstructured":"Messika-Zeitoun D, Serfaty JM, Brochet E et al (2010) Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 55(3):186\u2013194","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"3607_CR8","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/CIRCULATIONAHA.110.946533","volume":"123","author":"C Tamburino","year":"2011","unstructured":"Tamburino C, Capodanno D, Ramondo A et al (2011) Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 123(3):299\u2013308","journal-title":"Circulation"},{"issue":"5","key":"3607_CR9","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.jtcvs.2009.10.056","volume":"139","author":"J Ye","year":"2010","unstructured":"Ye J, Cheung A, Lichtenstein SV et al (2010) Transapical transcatheter aortic valve implantation: follow-up to 3 years. J Thorac Cardiovasc Surg 139(5):1107\u20131113, 1113 e1101","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"9","key":"3607_CR10","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.jcin.2009.07.003","volume":"2","author":"D Detaint","year":"2009","unstructured":"Detaint D, Lepage L, Himbert D et al (2009) Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv 2(9):821\u2013827","journal-title":"JACC Cardiovasc Interv"},{"issue":"1","key":"3607_CR11","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ejrad.2009.01.028","volume":"74","author":"M Smid","year":"2010","unstructured":"Smid M, Ferda J, Baxa J et al (2010) Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis. Eur J Radiol 74(1):152\u2013155","journal-title":"Eur J Radiol"},{"issue":"8","key":"3607_CR12","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1007\/s10554-011-9838-x","volume":"27","author":"LM Heer de","year":"2011","unstructured":"de Heer LM, Budde RP, Mali WP, de Vos AM, van Herwerden LA, Kluin J (2011) Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography. Int J Cardiovasc Imaging 27(8):1195\u20131204","journal-title":"Int J Cardiovasc Imaging"},{"issue":"14","key":"3607_CR13","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.jacc.2011.11.045","volume":"59","author":"H Jilaihawi","year":"2012","unstructured":"Jilaihawi H, Kashif M, Fontana G et al (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275\u20131286","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"3607_CR14","doi-asserted-by":"crossref","first-page":"872","DOI":"10.2214\/AJR.10.4232","volume":"195","author":"P Blanke","year":"2010","unstructured":"Blanke P, Euringer W, Baumann T et al (2010) Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation. AJR Am J Roentgenol 195(4):872\u2013881","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"3607_CR15","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1016\/j.athoracsur.2012.06.044","volume":"94","author":"F Plank","year":"2012","unstructured":"Plank F, Friedrich G, Bartel T et al (2012) Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation. Ann Thorac Surg 94(6):1961\u20131966","journal-title":"Ann Thorac Surg"},{"issue":"1","key":"3607_CR16","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1093\/ejcts\/ezs155","volume":"43","author":"N Buzzatti","year":"2013","unstructured":"Buzzatti N, Maisano F, Latib A et al (2013) Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation. Eur J Cardiothorac Surg 43(1):43\u201350, discussion 50\u201341","journal-title":"Eur J Cardiothorac Surg"},{"issue":"14","key":"3607_CR17","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1016\/j.jacc.2011.12.015","volume":"59","author":"AB Willson","year":"2012","unstructured":"Willson AB, Webb JG, Labounty TM et al (2012) 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 59(14):1287\u20131294","journal-title":"J Am Coll Cardiol"},{"issue":"2","key":"3607_CR18","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/j.athoracsur.2011.08.068","volume":"93","author":"LM Heer de","year":"2012","unstructured":"de Heer LM, Budde RP, van Prehn J et al (2012) Pulsatile distention of the nondiseased and stenotic aortic valve annulus: analysis with electrocardiogram-gated computed tomography. Ann Thorac Surg 93(2):516\u2013522","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"3607_CR19","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.jacc.2011.09.045","volume":"59","author":"A Hamdan","year":"2012","unstructured":"Hamdan A, Guetta V, Konen E et al (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59(2):119\u2013127","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"3607_CR20","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00330-011-2233-0","volume":"22","author":"W Wuest","year":"2012","unstructured":"Wuest W, Anders K, Schuhbaeck A et al (2012) Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 22(1):51\u201358","journal-title":"Eur Radiol"},{"issue":"7","key":"3607_CR21","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1002\/ccd.22654","volume":"76","author":"A Hutter","year":"2010","unstructured":"Hutter A, Opitz A, Bleiziffer S et al (2010) Aortic annulus evaluation in transcatheter aortic valve implantation. Catheter Cardiovasc Interv 76(7):1009\u20131019","journal-title":"Catheter Cardiovasc Interv"},{"issue":"1","key":"3607_CR22","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s00330-011-2257-5","volume":"22","author":"M Beeres","year":"2012","unstructured":"Beeres M, Schell B, Mastragelopoulos A et al (2012) High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: initial experience. Eur Radiol 22(1):129\u2013137","journal-title":"Eur Radiol"},{"issue":"8","key":"3607_CR23","doi-asserted-by":"crossref","first-page":"2091","DOI":"10.1007\/s10554-012-0018-4","volume":"28","author":"AG Bertaso","year":"2012","unstructured":"Bertaso AG, Wong DT, Liew GY et al (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28(8):2091\u20132098","journal-title":"Int J Cardiovasc Imaging"},{"issue":"6","key":"3607_CR24","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","volume":"6","author":"S Achenbach","year":"2012","unstructured":"Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6(6):366\u2013380","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"3","key":"3607_CR25","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s10554-012-0123-4","volume":"29","author":"L Lehmkuhl","year":"2013","unstructured":"Lehmkuhl L, Foldyna B, Von Aspern K et al (2013) Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Int J Cardiovasc Imaging 29(3):693\u2013703","journal-title":"Int J Cardiovasc Imaging"},{"issue":"1","key":"3607_CR26","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.jcct.2013.12.001","volume":"8","author":"L Azzalini","year":"2014","unstructured":"Azzalini L, Sharma UC, Ghoshhajra BB et al (2014) Feasibility of C-arm computed tomography for transcatheter aortic valve replacement planning. J Cardiovasc Comput Tomogr 8(1):33\u201343","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"6","key":"3607_CR27","first-page":"H795","volume":"241","author":"M Thubrikar","year":"1981","unstructured":"Thubrikar M, Piepgrass WC, Shaner TW, Nolan SP (1981) The design of the normal aortic valve. Am J Physiol 241(6):H795\u2013H801","journal-title":"Am J Physiol"},{"issue":"9","key":"3607_CR28","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1016\/j.amjcard.2009.01.034","volume":"103","author":"DA Wood","year":"2009","unstructured":"Wood DA, Tops LF, Mayo JR et al (2009) Role of multislice computed tomography in transcatheter aortic valve replacement. Am J Cardiol 103(9):1295\u20131301","journal-title":"Am J Cardiol"},{"issue":"3","key":"3607_CR29","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.jcmg.2007.12.006","volume":"1","author":"LF Tops","year":"2008","unstructured":"Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321\u2013330","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"3607_CR30","doi-asserted-by":"crossref","first-page":"29","DOI":"10.14797\/mdcj-8-2-29","volume":"8","author":"SH Little","year":"2012","unstructured":"Little SH, Shah DJ, Mahmarian JJ (2012) Multimodality noninvasive imaging for transcatheter aortic valve implantation: a primer. Methodist Debakey Cardiovasc J 8(2):29\u201337","journal-title":"Methodist Debakey Cardiovasc J"},{"issue":"10","key":"3607_CR31","first-page":"941","volume":"184","author":"L Lehmkuhl","year":"2013","unstructured":"Lehmkuhl L, Foldyna B, Haensig M et al (2013) Role of preprocedural computed tomography in transcatheter aortic valve implantation. R\u00f6Fo 184(10):941\u2013949","journal-title":"R\u00f6Fo"},{"issue":"5","key":"3607_CR32","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/j.jacc.2007.10.023","volume":"51","author":"R Zegdi","year":"2008","unstructured":"Zegdi R, Ciobotaru V, Noghin M et al (2008) Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. J Am Coll Cardiol 51(5):579\u2013584","journal-title":"J Am Coll Cardiol"},{"issue":"18","key":"3607_CR33","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","volume":"366","author":"SK Kodali","year":"2012","unstructured":"Kodali SK, Williams MR, Smith CR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366(18):1686\u20131695","journal-title":"N Engl J Med"},{"issue":"5","key":"3607_CR34","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1016\/j.athoracsur.2010.05.072","volume":"90","author":"M Pasic","year":"2010","unstructured":"Pasic M, Buz S, Dreysse S et al (2010) Transapical aortic valve implantation in 194 patients: problems, complications, and solutions. Ann Thorac Surg 90(5):1463\u20131469, discussion 1469\u20131470","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"3607_CR35","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.ejcts.2010.09.002","volume":"39","author":"A Colli","year":"2011","unstructured":"Colli A, Nofrerias EF, Escudero A (2011) Aortic root rupture during trans-catheter aortic valve implantation. Eur J Cardiothorac Surg 39(5):788","journal-title":"Eur J Cardiothorac Surg"},{"issue":"10","key":"3607_CR36","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.4244\/EIJV9I10A194","volume":"9","author":"P Houthuizen","year":"2014","unstructured":"Houthuizen P, van der Boon RM, Urena M et al (2014) Occurrence, fate and consequences of ventricular conduction abnormalities after transcatheter aortic valve implantation. EuroIntervention 9(10):1142\u20131150","journal-title":"EuroIntervention"},{"issue":"11","key":"3607_CR37","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1016\/j.jcin.2011.07.014","volume":"4","author":"R Gurvitch","year":"2011","unstructured":"Gurvitch R, Webb JG, Yuan R et al (2011) Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4(11):1235\u20131245","journal-title":"JACC Cardiovasc Interv"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-015-3607-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-015-3607-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-015-3607-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,26]],"date-time":"2019-02-26T14:13:43Z","timestamp":1551190423000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-015-3607-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,24]]},"references-count":37,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["3607"],"URL":"https:\/\/doi.org\/10.1007\/s00330-015-3607-5","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,24]]}}}