{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T15:34:48Z","timestamp":1783092888250,"version":"3.54.6"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2015,12,2]],"date-time":"2015-12-02T00:00:00Z","timestamp":1449014400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","award":["Om-12-01 IIT"],"award-info":[{"award-number":["Om-12-01 IIT"]}],"id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1007\/s00330-015-4109-1","type":"journal-article","created":{"date-parts":[[2015,12,2]],"date-time":"2015-12-02T16:44:42Z","timestamp":1449074682000},"page":"2446-2454","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Lowering iodinated contrast concentration in infrainguinal endovascular interventions: a three-armed randomized controlled non-inferiority trial"],"prefix":"10.1007","volume":"26","author":[{"given":"Sjoerd","family":"Jens","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanne M.","family":"Schreuder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diederik W.","family":"De Boo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas C.","family":"van Dijk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"van Overhagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shandra","family":"Bipat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark J. W.","family":"Koelemay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jim A.","family":"Reekers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,12,2]]},"reference":[{"key":"4109_CR1","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1007\/s00330-011-2225-0","volume":"21","author":"F Stacul","year":"2011","unstructured":"Stacul F, van der Molen AJ, Reimer P et al (2011) Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines. Eur Radiol 21:2527\u20132541","journal-title":"Eur Radiol"},{"key":"4109_CR2","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1007\/s003300050894","volume":"9","author":"SK Morcos","year":"1999","unstructured":"Morcos SK, Thomsen HS, Webb JA (1999) Contrast-media-induced nephrotoxicity: a consensus report. Eur Radiol 9:1602\u20131613","journal-title":"Eur Radiol"},{"key":"4109_CR3","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/01.RVI.0000145224.02920.C2","volume":"16","author":"SK Morcos","year":"2005","unstructured":"Morcos SK (2005) Prevention of contrast media-induced nephrotoxicity after angiographic procedures. J Vasc Interv Radiol 16:13\u201323","journal-title":"J Vasc Interv Radiol"},{"key":"4109_CR4","first-page":"51","volume":"3","author":"J Golshahi","year":"2014","unstructured":"Golshahi J, Nasri H, Gharipour M (2014) Contrast-induced nephropathy; A literature review. J Nephropathol 3:51\u201356","journal-title":"J Nephropathol"},{"key":"4109_CR5","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1016\/j.amjcard.2014.07.059","volume":"114","author":"A Ukaigwe","year":"2014","unstructured":"Ukaigwe A, Karmacharya P, Mahmood M et al (2014) Meta-analysis on efficacy of statins for prevention of contrast-induced acute kidney injury in patients undergoing coronary angiography. Am J Cardiol 114:1295\u20131302","journal-title":"Am J Cardiol"},{"key":"4109_CR6","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1007\/BF02552447","volume":"6","author":"W Seyferth","year":"1983","unstructured":"Seyferth W, Dilbat G, Zeitler E (1983) Efficacy and safety of digital subtraction angiography with special reference to contrast agents. Cardiovasc Intervent Radiol 6:265\u2013270","journal-title":"Cardiovasc Intervent Radiol"},{"key":"4109_CR7","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1177\/028418519103200210","volume":"32","author":"GP Naisby","year":"1991","unstructured":"Naisby GP, Owen JP, Alexander TW, Cope L, Laker MF, Hamilton PJ (1991) Transfemoral digital subtraction aortography. Are diluted high osmolar contrast media acceptable? Acta Radiol 32:137\u2013140","journal-title":"Acta Radiol"},{"key":"4109_CR8","doi-asserted-by":"crossref","first-page":"S77","DOI":"10.1016\/0720-048X(94)90098-1","volume":"18","author":"U Ugolotti","year":"1994","unstructured":"Ugolotti U, Larini P, Marcato C, Cusmano F, Puccianti F (1994) Peripheral arteriography with a new nonionic agent: comparison of iomeprol with iopamidol. Eur J Radiol 18:S77\u2013S82","journal-title":"Eur J Radiol"},{"key":"4109_CR9","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s10157-013-0843-3","volume":"17","author":"I Ohno","year":"2013","unstructured":"Ohno I, Hayashi H, Aonuma K et al (2013) Guidelines on the use of iodinated contrast media in patients with kidney disease 2012: digest version : JSN, JRS, and JCS Joint Working Group. Clin Exp Nephrol 17:441\u2013479","journal-title":"Clin Exp Nephrol"},{"key":"4109_CR10","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1016\/S0140-6736(00)04337-3","volume":"357","author":"D Moher","year":"2001","unstructured":"Moher D, Schulz KF, Altman DG (2001) The CONSORT statement: revised recommendations for improving the quality of reports of parallel-group randomised trials. Lancet 357:1191\u20131194","journal-title":"Lancet"},{"key":"4109_CR11","unstructured":"Radiological Society of North America Radlex Web site. Image quality. Available via http:\/\/www.radlex.org\/RID\/RID10 . Accessed 20 Nov 2014"},{"key":"4109_CR12","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1148\/radiol.2331031595","volume":"233","author":"ME Adriaensen","year":"2004","unstructured":"Adriaensen ME, Kock MC, Stijnen T et al (2004) Peripheral arterial disease: therapeutic confidence of CT versus digital subtraction angiography and effects on additional imaging recommendations. Radiology 233:385\u2013391","journal-title":"Radiology"},{"key":"4109_CR13","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1080\/02841850802050762","volume":"49","author":"U Nyman","year":"2008","unstructured":"Nyman U, Bj\u00f6rk J, Aspelin P, Marenzi G (2008) Contrast medium dose-to-GFR ratio: a measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention. Acta Radiol 49:658\u2013667","journal-title":"Acta Radiol"},{"key":"4109_CR14","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1016\/j.jvs.2013.12.039","volume":"59","author":"P Kougias","year":"2014","unstructured":"Kougias P, Sharath S, Barshes NR et al (2014) Impact of cumulative intravascular contrast exposure on renal function in patients with occlusive and aneurysmal vascular disease. J Vasc Surg 59:1644\u20131650","journal-title":"J Vasc Surg"},{"key":"4109_CR15","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/S0009-9260(99)90688-8","volume":"54","author":"NR Bees","year":"1999","unstructured":"Bees NR, Beese RC, Belli AM, Buckenham TM (1999) Carbon dioxide angiography of the lower limbs: initial experience with an automated carbon dioxide injector. Clin Radiol 54:833\u2013838","journal-title":"Clin Radiol"},{"key":"4109_CR16","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S1051-0443(07)61460-2","volume":"11","author":"LP D\u00edaz","year":"2000","unstructured":"D\u00edaz LP, Pab\u00f3n IP, Garc\u00eda JA, de la Cal L\u00f3pez MA (2000) Assessment of CO2 arteriography in arterial occlusive disease of the lower extremities. J Vasc Interv Radiol 11:163\u2013169","journal-title":"J Vasc Interv Radiol"},{"key":"4109_CR17","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1111\/j.1754-9485.2009.02035.x","volume":"53","author":"KS Madhusudhan","year":"2009","unstructured":"Madhusudhan KS, Sharma S, Srivastava DN et al (2009) Comparison of intra-arterial digital subtraction angiography using carbon dioxide by \u2018home made\u2019 delivery system and conventional iodinated contrast media in the evaluation of peripheral arterial occlusive disease of the lower limbs. J Med Imaging Radiat Oncol 53:40\u201349","journal-title":"J Med Imaging Radiat Oncol"},{"key":"4109_CR18","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S1607-551X(09)70513-3","volume":"19","author":"CF Ho","year":"2003","unstructured":"Ho CF, Chern MS, Wu MH et al (2003) Carbon dioxide angiography in lower limbs: a prospective comparative study with selective iodinated contrast angiography. Kaohsiung J Med Sci 19:599\u2013607","journal-title":"Kaohsiung J Med Sci"},{"key":"4109_CR19","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/S1051-0443(99)70106-5","volume":"10","author":"VL Oliva","year":"1999","unstructured":"Oliva VL, Denbow N, Th\u00e9rasse E et al (1999) Digital subtraction angiography of the abdominal aorta and lower extremities: carbon dioxide versus iodinated contrast material. J Vasc Interv Radiol 10:723\u2013731","journal-title":"J Vasc Interv Radiol"},{"key":"4109_CR20","doi-asserted-by":"crossref","first-page":"333","DOI":"10.2214\/ajr.171.2.9694446","volume":"171","author":"Y Rolland","year":"1998","unstructured":"Rolland Y, Duvauferrier R, Lucas A et al (1998) Lower limb angiography: a prospective study comparing carbon dioxide with iodinated contrast material in 30 patients. Am J Roentgenol 171:333\u2013337","journal-title":"Am J Roentgenol"},{"key":"4109_CR21","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1097\/00000658-199306000-00011","volume":"217","author":"JM Seeger","year":"1993","unstructured":"Seeger JM, Self S, Harward TR, Flynn TC, Hawkins IF Jr (1993) Carbon dioxide gas as an arterial contrast agent. Ann Surg 217:688\u2013697","journal-title":"Ann Surg"},{"key":"4109_CR22","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1007\/s003300050643","volume":"9","author":"FD Hammer","year":"1999","unstructured":"Hammer FD, Goffette PP, Malaise J, Mathurin P (1999) Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography. Eur Radiol 9:128\u2013136","journal-title":"Eur Radiol"},{"key":"4109_CR23","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/00004424-200105000-00003","volume":"36","author":"HJ Wagner","year":"2001","unstructured":"Wagner HJ, Kalinowski M, Klose KJ, Alfke H (2001) The use of gadolinium chelates for X-ray digital subtraction angiography. Invest Radiol 36:257\u2013265","journal-title":"Invest Radiol"},{"key":"4109_CR24","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1148\/radiol.2232010221","volume":"223","author":"U Nyman","year":"2002","unstructured":"Nyman U, Elmst\u00e5hl B, Leander P, Nilsson M, Golman K, Alm\u00e9n T (2002) Are gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia? Radiology 223:311\u2013318","journal-title":"Radiology"},{"key":"4109_CR25","doi-asserted-by":"crossref","first-page":"2526","DOI":"10.1093\/ndt\/gfh272","volume":"19","author":"CM Erley","year":"2004","unstructured":"Erley CM, Bader BD, Berger ED et al (2004) Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients. Nephrol Dial Transplant 19:2526\u20132531","journal-title":"Nephrol Dial Transplant"},{"key":"4109_CR26","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.amjcard.2004.08.056","volume":"95","author":"G Dangas","year":"2005","unstructured":"Dangas G, Iakovou I, Nikolsky E et al (2005) Contrast-induced nephropathy after percutaneous coronary interventions in relation to chronic kidney disease and hemodynamic variables. Am J Cardiol 95:13\u201319","journal-title":"Am J Cardiol"},{"key":"4109_CR27","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.jcin.2013.02.007","volume":"6","author":"M Yamamoto","year":"2013","unstructured":"Yamamoto M, Hayashida K, Mouillet G et al (2013) Renal function-based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation. JACC Cardiovasc Interv 6:479\u2013486","journal-title":"JACC Cardiovasc Interv"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-015-4109-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-015-4109-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-015-4109-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,2]],"date-time":"2019-09-02T00:40:40Z","timestamp":1567384840000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-015-4109-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,2]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["4109"],"URL":"https:\/\/doi.org\/10.1007\/s00330-015-4109-1","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,2]]}}}