{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T19:02:42Z","timestamp":1771268562792,"version":"3.50.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2017,8,30]],"date-time":"2017-08-30T00:00:00Z","timestamp":1504051200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Zon-MW (Innovative Medical Devices Initiative LSH)","award":["10-10400-98-14017"],"award-info":[{"award-number":["10-10400-98-14017"]}]},{"DOI":"10.13039\/501100002996","name":"Hartstichting","doi-asserted-by":"publisher","award":["CVON2015-17"],"award-info":[{"award-number":["CVON2015-17"]}],"id":[{"id":"10.13039\/501100002996","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2018,2]]},"DOI":"10.1007\/s00330-017-5018-2","type":"journal-article","created":{"date-parts":[[2017,8,30]],"date-time":"2017-08-30T04:38:43Z","timestamp":1504067923000},"page":"844-850","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Accurate late gadolinium enhancement prediction by early T1- based quantitative synthetic mapping"],"prefix":"10.1007","volume":"28","author":[{"given":"Randy","family":"van Dijk","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirkjan","family":"Kuijpers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Theodorus A. M.","family":"Kaandorp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul R. M.","family":"van Dijkman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rozemarijn","family":"Vliegenthart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pim","family":"van der Harst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthijs","family":"Oudkerk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,8,30]]},"reference":[{"key":"5018_CR1","doi-asserted-by":"crossref","first-page":"3318","DOI":"10.1161\/01.CIR.94.12.3318","volume":"94","author":"RJ Kim","year":"1996","unstructured":"Kim RJ, Chen EL, Lima JA, Judd RM (1996) Myocardial Gd-DTPA kinetics determine MR imaging contrast enhancement and reflect the extent and severity of myocardial injury after acute reperfused infarction. Circulation 94:3318\u20133326","journal-title":"Circulation"},{"key":"5018_CR2","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1186\/1532-429X-14-61","volume":"14","author":"J Schwitter","year":"2012","unstructured":"Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Sch\u00f6nberg SO, Debl K, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T (2012) Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial). J Cardiovasc Magn Res. 14:61\u201371","journal-title":"J Cardiovasc Magn Res."},{"key":"5018_CR3","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0140-6736(11)61335-4","volume":"379","author":"JP Greenwood","year":"2012","unstructured":"Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ, Ball SG, Plein S (2012) Cardiovascular magnetic resonance and sin-gle-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet 379:453\u2013460","journal-title":"Lancet"},{"key":"5018_CR4","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1002\/mrm.23153","volume":"67","author":"H Xue","year":"2012","unstructured":"Xue H, Shah S, Greiser A, Guetter C, Littmann A, Jolly M-P, Arai AE, Zuehlsdorff S, Guehring J, Kellman P (2012) Motion correction for myocardial T1 mapping using image registration with synthetic image estimation. Magn Reson Med 67:1644\u20131655","journal-title":"Magn Reson Med"},{"key":"5018_CR5","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1002\/mrm.24385","volume":"69","author":"H Xue","year":"2013","unstructured":"Xue H, Greiser A, Zuehhldorff S, Jolly M-P, Guehring J, Arai AE, Kellman P (2013) Phase-Sensitive Inversion Recovery for Myocardial T1 Mapping with Motion Correction and Parametric Fitting. Magn Reson Med. 69:1408\u20131420","journal-title":"Magn Reson Med."},{"key":"5018_CR6","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/1532-429X-16-2","volume":"16","author":"P Kellman","year":"2014","unstructured":"Kellman P, Hansen MS (2014) T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson 16:2","journal-title":"J Cardiovasc Magn Reson"},{"key":"5018_CR7","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1148\/radiol.2015150162","volume":"278","author":"A Varga-Szemes","year":"2016","unstructured":"Varga-Szemes A, van der Geest RJ, Spottiswoode BS, Suranyi P, Ruzsics B, De Cecco CN, Muscogiuri G, Cannao PM, Fox MA, Wichmann JL, Vliegenthart R, Schoepf UJ (2016) Myocardial late gadolinium enhancement: Accuracy of T1 mapping-based synthetic Inversion-recovery imaging. Radiology 278:374\u2013382","journal-title":"Radiology"},{"key":"5018_CR8","doi-asserted-by":"crossref","first-page":"3235","DOI":"10.1007\/s00330-016-4665-z","volume":"27","author":"A Varga-Szemes","year":"2017","unstructured":"Varga-Szemes A, van der Geest RJ, Schoepf UJ, Spottiswoode BS, De Cecco CN, Muscogiuri G et al (2017) Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging. Eur Radiol 27:3235\u20133243","journal-title":"Eur Radiol"},{"key":"5018_CR9","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1161\/hc0402.102975","volume":"105","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Counsil on Clinical Cardiology of the American Heart Association. Circulation 105:535\u2013542","journal-title":"Circulation"},{"key":"5018_CR10","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1148\/radiol.2461062164","volume":"246","author":"E Heiberg","year":"2008","unstructured":"Heiberg E, Ugander M, Engblom H, Gotberg M, Olivecrona GK, Erlinge D, Arheden H (2008) Automated quantification of myocardial infarction from MR images by accounting for partial volume effects: animal, phantom, and human study. Radiology 246:581\u2013588","journal-title":"Radiology"},{"key":"5018_CR11","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1080\/10976640601187604","volume":"9","author":"P Kellman","year":"2007","unstructured":"Kellman P, Arai AE (2007) Imaging sequences for first pass perfusion: A Review. J Cardiovasc Magn Reson 9:525\u2013537","journal-title":"J Cardiovasc Magn Reson"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-017-5018-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-017-5018-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-017-5018-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T04:43:41Z","timestamp":1513831421000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-017-5018-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,30]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["5018"],"URL":"https:\/\/doi.org\/10.1007\/s00330-017-5018-2","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,30]]}}}