{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T07:54:13Z","timestamp":1781942053897,"version":"3.54.5"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2018,1,15]],"date-time":"2018-01-15T00:00:00Z","timestamp":1515974400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1007\/s00330-017-5240-y","type":"journal-article","created":{"date-parts":[[2018,1,15]],"date-time":"2018-01-15T09:10:56Z","timestamp":1516007456000},"page":"2436-2443","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":51,"title":["Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE?"],"prefix":"10.1007","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0734-264X","authenticated-orcid":false,"given":"Morikatsu","family":"Yoshida","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taihei","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Tanoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sentaro","family":"Takada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Utsunomiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Tsumagari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazunori","family":"Harada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuyuki","family":"Yamashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,1,15]]},"reference":[{"key":"5240_CR1","doi-asserted-by":"publisher","first-page":"432","DOI":"10.2214\/ajr.185.2.01850432","volume":"185","author":"S Mazziotti","year":"2005","unstructured":"Mazziotti S, Costa C, Ascenti G, Gaeta M, Pandolfo A, Blandino A (2005) MR cholangiopancreatography diagnosis of juxtapapillary duodenal diverticulum simulating a cystic lesion of the pancreas: usefulness of an oral negative contrast agent. AJR Am J Roentgenol 185:432\u2013435","journal-title":"AJR Am J Roentgenol"},{"key":"5240_CR2","doi-asserted-by":"publisher","first-page":"812","DOI":"10.2214\/ajr.184.3.01840812","volume":"184","author":"C Valls","year":"2005","unstructured":"Valls C, Alba E, Cruz M et al (2005) Biliary complications after liver transplantation: diagnosis with MR cholangiopancreatography. AJR Am J Roentgenol 184:812\u2013820","journal-title":"AJR Am J Roentgenol"},{"key":"5240_CR3","doi-asserted-by":"publisher","first-page":"55","DOI":"10.2214\/ajr.184.1.01840055","volume":"184","author":"C Aube","year":"2005","unstructured":"Aube C, Delorme B, Yzet T et al (2005) MR cholangiopancreatography versus endoscopic sonography in suspected common bile duct lithiasis: a prospective, comparative study. AJR Am J Roentgenol 184:55\u201362","journal-title":"AJR Am J Roentgenol"},{"key":"5240_CR4","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1016\/j.mri.2005.07.002","volume":"23","author":"P Asbach","year":"2005","unstructured":"Asbach P, Klessen C, Kroencke TJ et al (2005) Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction. Magn Reson Imaging 23:939\u2013945","journal-title":"Magn Reson Imaging"},{"key":"5240_CR5","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.1007\/s00330-010-1714-x","volume":"20","author":"S Kinner","year":"2010","unstructured":"Kinner S, Dechene A, Ladd SC et al (2010) Comparison of different MRCP techniques for the depiction of biliary complications after liver transplantation. Eur Radiol 20:1749\u20131756","journal-title":"Eur Radiol"},{"key":"5240_CR6","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1002\/jmri.21485","volume":"28","author":"S Morita","year":"2008","unstructured":"Morita S, Ueno E, Suzuki K et al (2008) Navigator-triggered prospective acquisition correction (PACE) technique vs. conventional respiratory-triggered technique for free-breathing 3D MRCP: an initial prospective comparative study using healthy volunteers. J Magn Reson Imaging 28:673\u2013677","journal-title":"J Magn Reson Imaging"},{"key":"5240_CR7","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.2214\/AJR.05.1032","volume":"187","author":"J Zhang","year":"2006","unstructured":"Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS (2006) Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study. AJR Am J Roentgenol 187:1564\u20131570","journal-title":"AJR Am J Roentgenol"},{"key":"5240_CR8","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1097\/01.rli.0000261940.98762.20","volume":"42","author":"ST Schindera","year":"2007","unstructured":"Schindera ST, Miller CM, Ho LM, DeLong DM, Merkle EM (2007) Magnetic resonance (MR) cholangiography: quantitative and qualitative comparison of 3.0 Tesla with 1.5 Tesla. Invest Radiol 42:399\u2013405","journal-title":"Invest Radiol"},{"key":"5240_CR9","doi-asserted-by":"publisher","first-page":"1346","DOI":"10.1002\/jmri.25289","volume":"44","author":"K Yokoyama","year":"2016","unstructured":"Yokoyama K, Nakaura T, Iyama Y et al (2016) Usefulness of 3D hybrid profile order technique with 3T magnetic resonance cholangiography: comparison of image quality and acquisition time. J Magn Reson Imaging 44:1346\u20131353","journal-title":"J Magn Reson Imaging"},{"key":"5240_CR10","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1067\/mge.2002.120324","volume":"55","author":"AC Taylor","year":"2002","unstructured":"Taylor AC, Little AF, Hennessy OF, Banting SW, Smith PJ, Desmond PV (2002) Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc 55:17\u201322","journal-title":"Gastrointest Endosc"},{"key":"5240_CR11","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1148\/radiol.2493080389","volume":"249","author":"KR Nandalur","year":"2008","unstructured":"Nandalur KR, Hussain HK, Weadock WJ et al (2008) Possible biliary disease: diagnostic performance of high-spatial-resolution isotropic 3D T2-weighted MRCP. Radiology 249:883\u2013890","journal-title":"Radiology"},{"key":"5240_CR12","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1148\/radiology.181.2.1924811","volume":"181","author":"DA Feinberg","year":"1991","unstructured":"Feinberg DA, Oshio K (1991) GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique. Radiology 181:597\u2013602","journal-title":"Radiology"},{"key":"5240_CR13","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/S0730-725X(99)00140-X","volume":"18","author":"A Ba-Ssalamaha","year":"2000","unstructured":"Ba-Ssalamaha A, Schick S, Heimberger K et al (2000) Ultrafast magnetic resonance imaging of the brain. Magn Reson Imaging 18:237\u2013243","journal-title":"Magn Reson Imaging"},{"key":"5240_CR14","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1186\/s12968-015-0199-9","volume":"17","author":"R Fernandez-Jimenez","year":"2015","unstructured":"Fernandez-Jimenez R, Sanchez-Gonzalez J, Aguero J et al (2015) Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia\/reperfusion. J Cardiovasc Magn Reson 17:92","journal-title":"J Cardiovasc Magn Reson"},{"key":"5240_CR15","doi-asserted-by":"publisher","first-page":"963","DOI":"10.2214\/ajr.165.4.7677002","volume":"165","author":"MR Patel","year":"1995","unstructured":"Patel MR, Klufas RA, Shapiro AW (1995) MR imaging of diseases of the brain: comparison of GRASE and conventional spin-echo T2-weighted pulse sequences. AJR Am J Roentgenol 165:963\u2013966","journal-title":"AJR Am J Roentgenol"},{"key":"5240_CR16","first-page":"1923","volume":"18","author":"DT Rockwell","year":"1997","unstructured":"Rockwell DT, Melhem ER, Bhatia RG (1997) GRASE (gradient- and spin-echo) MR of the brain. AJNR Am J Neuroradiol 18:1923\u20131928","journal-title":"AJNR Am J Neuroradiol"},{"key":"5240_CR17","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s12968-015-0127-z","volume":"17","author":"AM Sprinkart","year":"2015","unstructured":"Sprinkart AM, Luetkens JA, Traber F et al (2015) Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping. J Cardiovasc Magn Reson 17:12","journal-title":"J Cardiovasc Magn Reson"},{"key":"5240_CR18","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1002\/jmri.20572","volume":"23","author":"T Yoshikawa","year":"2006","unstructured":"Yoshikawa T, Mitchell DG, Hirota S et al (2006) Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions. J Magn Reson Imaging 23:712\u2013719","journal-title":"J Magn Reson Imaging"},{"key":"5240_CR19","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1002\/jmri.20544","volume":"23","author":"T Yoshikawa","year":"2006","unstructured":"Yoshikawa T, Mitchell DG, Hirota S et al (2006) Focal liver lesions: breathhold gradient- and spin-echo T2-weighted imaging for detection and characterization. J Magn Reson Imaging 23:520\u2013528","journal-title":"J Magn Reson Imaging"},{"key":"5240_CR20","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s12968-015-0177-2","volume":"17","author":"B Baessler","year":"2015","unstructured":"Baessler B, Schaarschmidt F, Stehning C, Schnackenburg B, Maintz D, Bunck AC (2015) Cardiac T2-mapping using a fast gradient echo spin echo sequence - first in vitro and in vivo experience. J Cardiovasc Magn Reson 17:67","journal-title":"J Cardiovasc Magn Reson"},{"key":"5240_CR21","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1097\/RCT.0000000000000401","volume":"40","author":"R Itatani","year":"2016","unstructured":"Itatani R, Namimoto T, Kusunoki S, Mizuguchi T, Ohtsuka S, Yamashita Y (2016) Usefulness of the short-echo time cube sequence at 3-T magnetic resonance cholangiopancreatography: prospective comparison with the conventional 3-dimensional fast spin-echo sequence. J Comput Assist Tomogr 40:551\u2013556","journal-title":"J Comput Assist Tomogr"},{"key":"5240_CR22","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1152\/jappl.1997.83.3.904","volume":"83","author":"PA Hardy","year":"1997","unstructured":"Hardy PA, Yue G (1997) Measurement of magnetic resonance T2 for physiological experiments. J Appl Physiol (1985) 83:904\u2013911","journal-title":"J Appl Physiol (1985)"},{"key":"5240_CR23","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1148\/radiographics.21.1.g01ja0523","volume":"21","author":"H Irie","year":"2001","unstructured":"Irie H, Honda H, Kuroiwa T et al (2001) Pitfalls in MR cholangiopancreatographic interpretation. Radiographics 21:23\u201337","journal-title":"Radiographics"},{"key":"5240_CR24","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1002\/mrm.1910260214","volume":"26","author":"K Oshio","year":"1992","unstructured":"Oshio K, Feinberg DA (1992) Single-shot GRASE imaging without fast gradients. Magn Reson Med 26:355\u2013360","journal-title":"Magn Reson Med"},{"key":"5240_CR25","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.clinimag.2008.02.024","volume":"32","author":"H Isoda","year":"2008","unstructured":"Isoda H, Maetani Y, Kataoka M et al (2008) Contrast behavior and image quality of magnetic resonance cholangiopancreatography imaging using variable echo times at 3.0 T. Clin Imaging 32:362\u2013366","journal-title":"Clin Imaging"},{"key":"5240_CR26","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1097\/00004728-199705000-00002","volume":"21","author":"G Jung","year":"1997","unstructured":"Jung G, Krahe T, Kugel H et al (1997) Prospective comparison of fast SE and GRASE sequences and echo planar imaging with conventional SE sequences in the detection of focal liver lesions at 1.0 T. J Comput Assist Tomogr 21:341\u2013347","journal-title":"J Comput Assist Tomogr"},{"key":"5240_CR27","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1148\/radiol.2333031977","volume":"233","author":"VS Lee","year":"2004","unstructured":"Lee VS, Krinsky GA, Nazzaro CA et al (2004) Defining intrahepatic biliary anatomy in living liver transplant donor candidates at mangafodipir trisodium-enhanced MR cholangiography versus conventional T2-weighted MR cholangiography. Radiology 233:659\u2013666","journal-title":"Radiology"},{"key":"5240_CR28","doi-asserted-by":"publisher","first-page":"e513","DOI":"10.1016\/j.ejrad.2011.06.004","volume":"81","author":"JH Kim","year":"2012","unstructured":"Kim JH, Hong SS, Eun HW, Han JK, Choi BI (2012) Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: comparison with conventional breath-hold 2D MRCP. Eur J Radiol 81:e513\u2013e518","journal-title":"Eur J Radiol"},{"key":"5240_CR29","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.3892\/ol.2015.2935","volume":"9","author":"K Liu","year":"2015","unstructured":"Liu K, Xie P, Peng W, Zhou Z (2015) Magnetic resonance cholangiopancreatography: comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions. Oncol Lett 9:1917\u20131921","journal-title":"Oncol Lett"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-017-5240-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-017-5240-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-017-5240-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,1,14]],"date-time":"2019-01-14T20:30:09Z","timestamp":1547497809000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-017-5240-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,15]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["5240"],"URL":"https:\/\/doi.org\/10.1007\/s00330-017-5240-y","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,15]]},"assertion":[{"value":"9 November 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2017","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2017","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Yasuyuki Yamashita","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: We were received MR technical supports from Kazuki Shigemi of Philips Electronics Japan, Ltd.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 diagnostic or prognostic study\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}