{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,5]],"date-time":"2025-12-05T12:16:43Z","timestamp":1764937003339,"version":"3.37.3"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,7,2]],"date-time":"2018-07-02T00:00:00Z","timestamp":1530489600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s00330-018-5596-7","type":"journal-article","created":{"date-parts":[[2018,7,2]],"date-time":"2018-07-02T06:22:20Z","timestamp":1530512540000},"page":"477-484","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Comparison of performance metrics with digital 2D versus tomosynthesis mammography in the diagnostic setting"],"prefix":"10.1007","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7728-7690","authenticated-orcid":false,"given":"Manisha","family":"Bahl","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Mercaldo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charmi A.","family":"Vijapura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne Marie","family":"McCarthy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Constance D.","family":"Lehman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,7,2]]},"reference":[{"issue":"2","key":"5596_CR1","doi-asserted-by":"publisher","first-page":"256","DOI":"10.2214\/AJR.16.17127","volume":"208","author":"RJ Hooley","year":"2017","unstructured":"Hooley RJ, Durand MA, Philpotts LE (2017) Advances in digital breast tomosynthesis. AJR Am J Roentgenol 208(2):256\u2013266","journal-title":"AJR Am J Roentgenol"},{"issue":"7","key":"5596_CR2","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","volume":"14","author":"S Ciatto","year":"2013","unstructured":"Ciatto S, Houssami N, Bernardi D et al (2013) Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Lancet Oncol 14(7):583\u2013589","journal-title":"Lancet Oncol"},{"issue":"1","key":"5596_CR3","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1148\/radiol.12121373","volume":"267","author":"P Skaane","year":"2013","unstructured":"Skaane P, Bandos AI, Gullien R et al (2013) Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 267(1):47\u201356","journal-title":"Radiology"},{"issue":"24","key":"5596_CR4","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1001\/jama.2014.6095","volume":"311","author":"SM Friedewald","year":"2014","unstructured":"Friedewald SM, Rafferty EA, Rose SL et al (2014) Breast cancer screening using tomosynthesis in combination with digital mammography. JAMA 311(24):2499\u20132507","journal-title":"JAMA"},{"key":"5596_CR5","doi-asserted-by":"crossref","unstructured":"McCarthy AM, Kontos D, Synnestvedt M et al (2014) Screening outcomes following implementation of digital breast tomosynthesis in a general-population screening program. J Natl Cancer Inst 106(11)","DOI":"10.1093\/jnci\/dju316"},{"issue":"3","key":"5596_CR6","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1148\/radiol.2015142036","volume":"278","author":"RE Sharpe Jr","year":"2016","unstructured":"Sharpe RE Jr, Venkataraman S, Phillips J et al (2016) Increased cancer detection rate and variations in the recall rate resulting from implementation of 3D digital breast tomosynthesis into a population-based screening program. Radiology 278(3):698\u2013706","journal-title":"Radiology"},{"issue":"1","key":"5596_CR7","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1148\/radiol.2016151999","volume":"281","author":"M Raghu","year":"2016","unstructured":"Raghu M, Durand MA, Andrejeva L et al (2016) Tomosynthesis in the diagnostic setting: changing rates of BI-RADS final assessment over time. Radiology 281(1):54\u201361","journal-title":"Radiology"},{"key":"5596_CR8","unstructured":"Sickles EA, D'Orsi CJ, Bassett LW et al (2013) ACR BI-RADS mammography. In: ACR BI-RADS atlas, breast imaging reporting and data system. American College of Radiology, Reston, VA"},{"issue":"6","key":"5596_CR9","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.2214\/AJR.12.9672","volume":"200","author":"SL Rose","year":"2013","unstructured":"Rose SL, Tidwell AL, Bujnoch LJ, Kushwaha AC, Nordmann AS, Sexton R Jr (2013) Implementation of breast tomosynthesis in a routine screening practice: an observational study. AJR Am J Roentgenol 200(6):1401\u20131408","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"5596_CR10","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1148\/radiol.2017171148","volume":"287","author":"M Bahl","year":"2017","unstructured":"Bahl M, Gaffney S, McCarthy AM, Lowry KP, Dang PA, Lehman CD (2017) Breast cancer characteristics associated with 2D digital mammography versus digital breast tomosynthesis for screening-detected and interval cancers. Radiology 287(1):49\u201357","journal-title":"Radiology"},{"issue":"1","key":"5596_CR11","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1148\/radiol.2017161519","volume":"283","author":"BL Sprague","year":"2017","unstructured":"Sprague BL, Arao RF, Miglioretti DL et al (2017) National performance benchmarks for modern diagnostic digital mammography: update from the Breast Cancer Surveillance Consortium. Radiology 283(1):59\u201369","journal-title":"Radiology"},{"issue":"5","key":"5596_CR12","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.2214\/AJR.17.17979","volume":"209","author":"M Bahl","year":"2017","unstructured":"Bahl M, Lamb LR, Lehman CD (2017) Pathologic outcomes of architectural distortion on digital 2D versus tomosynthesis mammography. AJR Am J Roentgenol 209(5):1162\u20131167","journal-title":"AJR Am J Roentgenol"},{"issue":"3","key":"5596_CR13","doi-asserted-by":"publisher","first-page":"616","DOI":"10.2214\/AJR.07.2231","volume":"189","author":"SP Poplack","year":"2007","unstructured":"Poplack SP, Tosteson TD, Kogel CA, Nagy HM (2007) Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. AJR Am J Roentgenol 189(3):616\u2013623","journal-title":"AJR Am J Roentgenol"},{"issue":"7","key":"5596_CR14","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1007\/s00330-009-1699-5","volume":"20","author":"G Gennaro","year":"2010","unstructured":"Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20(7):1545\u20131553","journal-title":"Eur Radiol"},{"issue":"2","key":"5596_CR15","doi-asserted-by":"publisher","first-page":"W172","DOI":"10.2214\/AJR.09.3244","volume":"195","author":"CM Hakim","year":"2010","unstructured":"Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D (2010) Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol 195(2):W172\u2013W176","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"5596_CR16","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1148\/radiol.11101763","volume":"262","author":"M Noroozian","year":"2012","unstructured":"Noroozian M, Hadjiiski L, Rahnama-Moghadam S et al (2012) Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization. Radiology 262(1):61\u201368","journal-title":"Radiology"},{"issue":"3","key":"5596_CR17","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1007\/s00330-011-2305-1","volume":"22","author":"A Tagliafico","year":"2012","unstructured":"Tagliafico A, Astengo D, Cavagnetto F et al (2012) One-to-one comparison between digital spot compression view and digital breast tomosynthesis. Eur Radiol 22(3):539\u2013544","journal-title":"Eur Radiol"},{"issue":"2","key":"5596_CR18","doi-asserted-by":"publisher","first-page":"291","DOI":"10.2214\/AJR.12.8881","volume":"200","author":"KR Brandt","year":"2013","unstructured":"Brandt KR, Craig DA, Hoskins TL et al (2013) Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting. AJR Am J Roentgenol 200(2):291\u2013298","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"5596_CR19","doi-asserted-by":"publisher","first-page":"226","DOI":"10.2214\/AJR.11.8202","volume":"200","author":"C Waldherr","year":"2013","unstructured":"Waldherr C, Cerny P, Altermatt HJ et al (2013) Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening. AJR Am J Roentgenol 200(1):226\u2013231","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"5596_CR20","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1148\/radiol.12120552","volume":"266","author":"ML Zuley","year":"2013","unstructured":"Zuley ML, Bandos AI, Ganott MA et al (2013) Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions. Radiology 266(1):89\u201395","journal-title":"Radiology"},{"issue":"3","key":"5596_CR21","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s00330-013-3012-x","volume":"24","author":"J Lei","year":"2014","unstructured":"Lei J, Yang P, Zhang L, Wang Y, Yang K (2014) Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysis. Eur Radiol 24(3):595\u2013602","journal-title":"Eur Radiol"},{"issue":"4","key":"5596_CR22","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1148\/rg.2015140204","volume":"35","author":"HR Peppard","year":"2015","unstructured":"Peppard HR, Nicholson BE, Rochman CM, Merchant JK, Mayo RC 3rd, Harvey JA (2015) Digital breast tomosynthesis in the diagnostic setting: indications and clinical applications. Radiographics 35(4):975\u2013990","journal-title":"Radiographics"},{"issue":"3","key":"5596_CR23","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.rcl.2016.12.010","volume":"55","author":"S Poplack","year":"2017","unstructured":"Poplack S (2017) Breast tomosynthesis: clinical evidence. Radiol Clin North Am 55(3):475\u2013492","journal-title":"Radiol Clin North Am"},{"issue":"2","key":"5596_CR24","doi-asserted-by":"publisher","first-page":"320","DOI":"10.2214\/AJR.10.4656","volume":"196","author":"ML Spangler","year":"2011","unstructured":"Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol 196(2):320\u2013324","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"5596_CR25","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.breast.2014.12.002","volume":"24","author":"TM Svahn","year":"2015","unstructured":"Svahn TM, Houssami N, Sechopoulos I, Mattsson S (2015) Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography. Breast 24(2):93\u201399","journal-title":"Breast"},{"issue":"2","key":"5596_CR26","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1007\/s00330-017-5024-4","volume":"28","author":"G Gennaro","year":"2018","unstructured":"Gennaro G, Bernardi D, Houssami N (2018) Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis. Eur Radiol 28(2):573\u2013581","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-018-5596-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5596-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5596-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T19:07:12Z","timestamp":1562008032000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-018-5596-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,2]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["5596"],"URL":"https:\/\/doi.org\/10.1007\/s00330-018-5596-7","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"type":"print","value":"0938-7994"},{"type":"electronic","value":"1432-1084"}],"subject":[],"published":{"date-parts":[[2018,7,2]]},"assertion":[{"value":"27 December 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Manisha Bahl, MD, MPH.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: Constance D. Lehman, MD, PhD, has a research grant from GE Healthcare and serves on an advisory board for GE Healthcare. The authors of this manuscript declare no other relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors (Sarah Mercaldo, PhD) has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 retrospective\u2022 observational\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}