{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T20:01:45Z","timestamp":1770667305500,"version":"3.49.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2018,10,2]],"date-time":"2018-10-02T00:00:00Z","timestamp":1538438400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000265","name":"Medical Research Council","doi-asserted-by":"publisher","award":["1367061"],"award-info":[{"award-number":["1367061"]}],"id":[{"id":"10.13039\/501100000265","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1007\/s00330-018-5707-5","type":"journal-article","created":{"date-parts":[[2018,10,2]],"date-time":"2018-10-02T13:24:53Z","timestamp":1538486693000},"page":"2027-2033","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Ultra-high-field arterial spin labelling MRI for non-contrast assessment of cortical lesion perfusion in multiple sclerosis"],"prefix":"10.1007","volume":"29","author":[{"given":"Richard J.","family":"Dury","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasser","family":"Falah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Penny A.","family":"Gowland","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikos","family":"Evangelou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7257-9646","authenticated-orcid":false,"given":"Molly G.","family":"Bright","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susan T.","family":"Francis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,10,2]]},"reference":[{"issue":"Pt 10","key":"5707_CR1","doi-asserted-by":"publisher","first-page":"2952","DOI":"10.1093\/brain\/aws246","volume":"135","author":"M Calabrese","year":"2012","unstructured":"Calabrese M, Poretto V, Favaretto A et al (2012) Cortical lesion load associates with progression of disability in multiple sclerosis. Brain 135(Pt 10):2952\u20132961","journal-title":"Brain"},{"issue":"9","key":"5707_CR2","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.1001\/archneurol.2009.174","volume":"66","author":"M Calabrese","year":"2009","unstructured":"Calabrese M, Agosta F, Rinaldi F et al (2009) Cortical lesions and atrophy associated with cognitive impairment in relapsing-remitting multiple sclerosis. Arch Neurol 66(9):1144\u20131150","journal-title":"Arch Neurol"},{"issue":"7","key":"5707_CR3","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1001\/archneurol.2010.148","volume":"67","author":"D Pitt","year":"2010","unstructured":"Pitt D, Boster A, Pei W et al (2010) Imaging cortical lesions in multiple sclerosis with ultra-high-field magnetic resonance imaging. Arch Neurol 67(7):812\u2013818","journal-title":"Arch Neurol"},{"issue":"3","key":"5707_CR4","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1002\/jmri.22847","volume":"35","author":"AS Nielsen","year":"2012","unstructured":"Nielsen AS, Kinkel RP, Tinelli E, Benner T, Cohen-Adad J, Mainero C (2012) Focal cortical lesion detection in multiple sclerosis: 3 Tesla DIR versus 7 Tesla FLASH-T2. J Magn Reson Imaging 35(3):537\u2013542","journal-title":"J Magn Reson Imaging"},{"key":"5707_CR5","unstructured":"Aphiwatthanasumet K, Mougin O, Geades N et al (2018) A longitudinal study of lesion evolution in multiple sclerosis using multi-contrast 7T MRI, Proceedings of the 26th Annual Meeting of the International Society for Magnetic Resonance in Medicine, Paris, France"},{"issue":"5","key":"5707_CR6","doi-asserted-by":"publisher","first-page":"1512","DOI":"10.1002\/mrm.26061","volume":"76","author":"O Mougin","year":"2016","unstructured":"Mougin O, Abdel-Fahim R, Dineen R, Pitiot A, Evangelou N, Gowland P (2016) Imaging gray matter with concomitant null point imaging from the phase sensitive inversion recovery sequence. Magn Reson Med 76(5):1512\u20131516","journal-title":"Magn Reson Med"},{"issue":"1","key":"5707_CR7","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1148\/radiol.2361040450","volume":"236","author":"JJ Geurts","year":"2005","unstructured":"Geurts JJ, Pouwels PJ, Uitdehaag BM, Polman CH, Barkhof F, Castelijns JA (2005) Intracortical lesions in multiple sclerosis: improved detection with 3D double inversion-recovery MR imaging. Radiology 236(1):254\u2013260","journal-title":"Radiology"},{"issue":"5","key":"5707_CR8","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1002\/(SICI)1522-2586(200005)11:5<495::AID-JMRI5>3.0.CO;2-S","volume":"11","author":"R Haselhorst","year":"2000","unstructured":"Haselhorst R, Kappos L, Bilecen D et al (2000) Dynamic susceptibility contrast MR imaging of plaque development in multiple sclerosis: application of an extended blood-brain barrier leakage correction. J Magn Reson Imaging 11(5):495\u2013505","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"5707_CR9","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1038\/jcbfm.2012.192","volume":"33","author":"D Peruzzo","year":"2013","unstructured":"Peruzzo D, Castellaro M, Calabrese M et al (2013) Heterogeneity of cortical lesions in multiple sclerosis: an MRI perfusion study. J Cereb Blood Flow Metab 33(3):457\u2013463","journal-title":"J Cereb Blood Flow Metab"},{"issue":"8","key":"5707_CR10","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.3174\/ajnr.A4737","volume":"37","author":"SP Hojjat","year":"2016","unstructured":"Hojjat SP, Kincal M, Vitorino R et al (2016) Cortical Perfusion Alteration in Normal-Appearing Gray Matter Is Most Sensitive to Disease Progression in Relapsing-Remitting Multiple Sclerosis. AJNR Am J Neuroradiol 37(8):1454\u20131461","journal-title":"AJNR Am J Neuroradiol"},{"issue":"Pt 1","key":"5707_CR11","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1093\/brain\/awh007","volume":"127","author":"J Wuerfel","year":"2004","unstructured":"Wuerfel J, Bellmann-Strobl J, Brunecker P et al (2004) Changes in cerebral perfusion precede plaque formation in multiple sclerosis: a longitudinal perfusion MRI study. Brain 127(Pt 1):111\u2013119","journal-title":"Brain"},{"issue":"3","key":"5707_CR12","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1148\/radiol.2015150337","volume":"275","author":"A Radbruch","year":"2015","unstructured":"Radbruch A, Weberling LD, Kieslich PJ et al (2015) Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent. Radiology 275(3):783\u2013791","journal-title":"Radiology"},{"issue":"3","key":"5707_CR13","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1148\/radiol.15150025","volume":"275","author":"RJ McDonald","year":"2015","unstructured":"McDonald RJ, McDonald JS, Kallmes DF et al (2015) Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging. Radiology 275(3):772\u2013782","journal-title":"Radiology"},{"issue":"1","key":"5707_CR14","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1148\/radiol.2015142690","volume":"276","author":"T Kanda","year":"2015","unstructured":"Kanda T, Fukusato T, Matsuda M et al (2015) Gadolinium-based Contrast Agent Accumulates in the Brain Even in Subjects without Severe Renal Dysfunction: Evaluation of Autopsy Brain Specimens with Inductively Coupled Plasma Mass Spectroscopy. Radiology 276(1):228\u2013232","journal-title":"Radiology"},{"issue":"3","key":"5707_CR15","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1148\/radiol.13131669","volume":"270","author":"T Kanda","year":"2014","unstructured":"Kanda T, Ishii K, Kawaguchi H, Kitajima K, Takenaka D (2014) High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 270(3):834\u2013841","journal-title":"Radiology"},{"issue":"5","key":"5707_CR16","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1136\/jnnp-2013-305612","volume":"85","author":"L Debernard","year":"2014","unstructured":"Debernard L, Melzer TR, Van Stockum S et al (2014) Reduced grey matter perfusion without volume loss in early relapsing-remitting multiple sclerosis. J Neurol Neurosurg Psychiatry 85(5):544\u2013551","journal-title":"J Neurol Neurosurg Psychiatry"},{"issue":"4","key":"5707_CR17","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1002\/mrm.21796","volume":"61","author":"AG Gardener","year":"2009","unstructured":"Gardener AG, Gowland PA, Francis ST (2009) Implementation of quantitative perfusion imaging using pulsed arterial spin labeling at ultra-high field. Magn Reson Med 61(4):874\u2013882","journal-title":"Magn Reson Med"},{"key":"5707_CR18","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1002\/ima.20218","volume":"20","author":"WM Teeuwisse","year":"2010","unstructured":"Teeuwisse WM, Webb AG, van Osch MJ (2010) Arterial Spin Labeling at Ultra-High Field: All That Glitters is Not Gold. Int J Imaging Syst Technol. 20:62\u201370. https:\/\/doi.org\/10.1002\/ima.20218","journal-title":"Int J Imaging Syst Technol."},{"key":"5707_CR19","unstructured":"Hall EL, Wesolowski R, Gowland PA, Francis ST (2010) Optimising image readout for perfusion imaging at 7T. Proceedings of the 18th Annual Scientific Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine, Stockholm, 1\u20137 May 2010"},{"issue":"1","key":"5707_CR20","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1111\/jon.12367","volume":"27","author":"AP Samaraweera","year":"2017","unstructured":"Samaraweera AP, Clarke MA, Whitehead A et al (2017) The Central Vein Sign in Multiple Sclerosis Lesions Is Present Irrespective of the T2* Sequence at 3 T. J Neuroimaging 27(1):114\u2013121","journal-title":"J Neuroimaging"},{"issue":"1","key":"5707_CR21","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1002\/mrm.22167","volume":"63","author":"AC Hurley","year":"2010","unstructured":"Hurley AC, Al-Radaideh A, Bai L et al (2010) Tailored RF pulse for magnetization inversion at ultrahigh field. Magn Reson Med 63(1):51\u201358","journal-title":"Magn Reson Med"},{"issue":"2","key":"5707_CR22","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1006\/nimg.2002.1132","volume":"17","author":"M Jenkinson","year":"2002","unstructured":"Jenkinson M, Bannister P, Brady M, Smith S (2002) Improved Optimisation for the Robust and Accurate Linear Registration and Motion Correction of Brain Images. Neuroimage 17(2):825\u2013841","journal-title":"Neuroimage"},{"issue":"3","key":"5707_CR23","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1002\/hbm.10062","volume":"17","author":"SM Smith","year":"2002","unstructured":"Smith SM (2002) Fast robust automated brain extraction. Hum Brain Mapp 17(3):143\u2013155","journal-title":"Hum Brain Mapp"},{"issue":"5","key":"5707_CR24","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1016\/j.mri.2014.01.016","volume":"32","author":"C Maumet","year":"2014","unstructured":"Maumet C, Maurel P, Ferr\u00e9 JC, Barillot C (2014) Robust estimation of the cerebral blood flow in arterial spin labelling. Magn Reson Imaging 32(5):497\u2013504","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"5707_CR25","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1002\/mrm.21792","volume":"60","author":"NP Blockley","year":"2008","unstructured":"Blockley NP, Jiang L, Gardener AG, Ludman CN, Francis ST, Gowland PA (2008) Field strength dependence of R1 and R2* relaxivities of human whole blood to ProHance, Vasovist, and deoxyhemoglobin. Magn Reson Med 60(6):1313\u20131320","journal-title":"Magn Reson Med"},{"issue":"2","key":"5707_CR26","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1002\/mrm.21442","volume":"59","author":"ST Francis","year":"2008","unstructured":"Francis ST, Bowtell R, Gowland PA (2008) Modeling and optimization of Look-Locker spin labeling for measuring perfusion and transit time changes in activation studies taking into account arterial blood volume. Magn Reson Med 59(2):316\u2013325","journal-title":"Magn Reson Med"},{"key":"5707_CR27","unstructured":"Dury RJ, Falah Y, Gowland PA, Evangelou N, Francis ST, Bright MG (2018) Reproducibility and quality assessment of a 3D-EPI pulsed arterial spin labelling scheme at 7 T in a clinical cohort, (abstract) Proc Intl Soc Magn Reson Med Ann Mtg Paris, France"},{"issue":"6","key":"5707_CR28","doi-asserted-by":"publisher","first-page":"2243","DOI":"10.1002\/mrm.25333","volume":"73","author":"AG Gardener","year":"2015","unstructured":"Gardener AG, Jezzard P (2015) Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla. Magn Reson Med 73(6):2243\u20132248","journal-title":"Magn Reson Med"},{"issue":"12","key":"5707_CR29","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.3174\/ajnr.A4939","volume":"37","author":"RM D'Ortenzio","year":"2016","unstructured":"D'Ortenzio RM, Hojjat SP, Vitorino R et al (2016) Comparison of Quantitative Cerebral Blood Flow Measurements Performed by Bookend Dynamic Susceptibility Contrast and Arterial Spin-Labeling MRI in Relapsing-Remitting Multiple Sclerosis. AJNR Am J Neuroradiol 37(12):2265\u20132272","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5707-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-018-5707-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5707-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,11]],"date-time":"2020-11-11T21:58:59Z","timestamp":1605131939000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-018-5707-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,2]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["5707"],"URL":"https:\/\/doi.org\/10.1007\/s00330-018-5707-5","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,2]]},"assertion":[{"value":"2 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Professor Susan Francis, PhD.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all patients in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All patients were selected based on having known pre-existing chronic cortical lesions (CLs) from scans of two prior studies. One of these studies developed the PSIR technique for improved CL detection and the second examined the \u2018central vein sign\u2019 in white matter lesions; neither of these earlier studies acquired arterial spin labelling data or quantified perfusion. Access to these earlier scans followed ethical guidelines to which consent was given.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 Prospective\u2022 Cross-sectional study\u2022 Performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}