{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T14:08:32Z","timestamp":1790345312149,"version":"4.1.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T00:00:00Z","timestamp":1544659200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,5]]},"DOI":"10.1007\/s00330-018-5889-x","type":"journal-article","created":{"date-parts":[[2018,12,13]],"date-time":"2018-12-13T04:38:41Z","timestamp":1544675921000},"page":"2253-2262","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":83,"title":["Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study"],"prefix":"10.1007","volume":"29","author":[{"given":"Kyungsoo","family":"Bae","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2267-0366","authenticated-orcid":false,"given":"Kyung Nyeo","family":"Jeon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moon Jung","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joon Sung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Young","family":"Ha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyeong Hwa","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ho Cheol","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,12,13]]},"reference":[{"key":"5889_CR1","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/00005382-199324000-00003","volume":"8","author":"CJ Bergin","year":"1993","unstructured":"Bergin CJ, Glover GM, Pauly J (1993) Magnetic resonance imaging of lung parenchyma. J Thorac Imaging 8:12\u201317","journal-title":"J Thorac Imaging"},{"key":"5889_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1053\/crad.2003.1157","volume":"58","author":"PD Gatehouse","year":"2003","unstructured":"Gatehouse PD, Bydder GM (2003) Magnetic resonance imaging of short T2 components in tissue. Clin Radiol 58:1\u201319","journal-title":"Clin Radiol"},{"key":"5889_CR3","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/00004728-200311000-00001","volume":"27","author":"MD Robson","year":"2003","unstructured":"Robson MD, Gatehouse PD, Bydder M, Bydder GM (2003) Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr 27:825\u2013846","journal-title":"J Comput Assist Tomogr"},{"key":"5889_CR4","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1002\/jmri.10432","volume":"19","author":"IL Reichert","year":"2004","unstructured":"Reichert IL, Benjamin M, Gatehouse PD et al (2004) Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences. J Magn Reson Imaging 19:99\u2013107","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR5","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.crad.2003.11.021","volume":"59","author":"MD Robson","year":"2004","unstructured":"Robson MD, Benjamin M, Gishen P, Bydder GM (2004) Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences. Clin Radiol 59:727\u2013735","journal-title":"Clin Radiol"},{"key":"5889_CR6","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1002\/mrm.1910330513","volume":"33","author":"DC Alsop","year":"1995","unstructured":"Alsop DC, Hatabu H, Bonnet M, Listerud J, Gefter W (1995) Multi-slice, breathhold imaging of the lung with submillisecond echo times. Magn Reson Med 33:678\u2013682","journal-title":"Magn Reson Med"},{"key":"5889_CR7","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1002\/jmri.22267","volume":"32","author":"M Takahashi","year":"2010","unstructured":"Takahashi M, Togao O, Obara M et al (2010) Ultra-short echo time (UTE) MR imaging of the lung: comparison between normal and emphysematous lungs in mutant mice. J Magn Reson Imaging 32:326\u2013333","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR8","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1002\/jmri.24680","volume":"41","author":"W Ma","year":"2015","unstructured":"Ma W, Sheikh K, Svenningsen S et al (2015) Ultra-short echo-time pulmonary MRI: evaluation and reproducibility in COPD subjects with and without bronchiectasis. J Magn Reson Imaging 41:1465\u20131474","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR9","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1002\/jmri.24232","volume":"39","author":"Y Ohno","year":"2014","unstructured":"Ohno Y, Nishio M, Koyama H et al (2014) Pulmonary 3 T MRI with ultrashort TEs: influence of ultrashort echo time interval on pulmonary functional and clinical stage assessments of smokers. J Magn Reson Imaging 39:988\u2013997","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR10","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1002\/mrm.24570","volume":"70","author":"KM Johnson","year":"2013","unstructured":"Johnson KM, Fain SB, Schiebler ML, Nagle S (2013) Optimized 3D ultrashort echo time pulmonary MRI. Magn Reson Med 70:1241\u20131250","journal-title":"Magn Reson Med"},{"key":"5889_CR11","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1002\/mrm.24816","volume":"70","author":"M Weiger","year":"2013","unstructured":"Weiger M, Brunner DO, Dietrich BE, M\u00fcller CF, Pruessmann KP (2013) ZTE imaging in humans. Magn Reson Med 70:328\u2013332","journal-title":"Magn Reson Med"},{"key":"5889_CR12","doi-asserted-by":"publisher","first-page":"360","DOI":"10.5152\/dir.2014.13458","volume":"20","author":"S Alibek","year":"2014","unstructured":"Alibek S, Vogel M, Sun W et al (2014) Acoustic noise reduction in MRI using Silent Scan: an initial experience. Diagn Interv Radiol 20:360\u2013363","journal-title":"Diagn Interv Radiol"},{"key":"5889_CR13","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1002\/nbm.3246","volume":"28","author":"M Weiger","year":"2015","unstructured":"Weiger M, Wu M, Wurnig MC et al (2015) ZTE imaging with long-T2 suppression. NMR Biomed 28:247\u2013254","journal-title":"NMR Biomed"},{"key":"5889_CR14","doi-asserted-by":"publisher","first-page":"404","DOI":"10.2214\/AJR.17.18247","volume":"210","author":"SJ Holdsworth","year":"2018","unstructured":"Holdsworth SJ, Macpherson SJ, Yeom KW, Wintermark M, Zaharchuk G (2018) Clinical evaluation of silent T1-weighted MRI and silent MR angiography of the brain. AJR Am J Roentgenol 210:404\u2013411","journal-title":"AJR Am J Roentgenol"},{"key":"5889_CR15","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1007\/s10334-014-0459-y","volume":"28","author":"F Gibiino","year":"2015","unstructured":"Gibiino F, Sacolick L, Menini A, Landini L, Wiesinger F (2015) Free-breathing, zero-TE MR lung imaging. MAGMA 28:207\u2013221","journal-title":"MAGMA"},{"key":"5889_CR16","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1053\/j.sult.2018.02.006","volume":"39","author":"JP Ko","year":"2018","unstructured":"Ko JP, Azour L (2018) Management of incidental lung nodules. Semin Ultrasound CT MR 39:249\u2013259","journal-title":"Semin Ultrasound CT MR"},{"key":"5889_CR17","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1148\/radiol.2017161659","volume":"284","author":"H MacMahon","year":"2017","unstructured":"MacMahon H, Naidich DP, Goo JM et al (2017) Guidelines for management of incidental pulmonary nodules detected on CT images: from the Fleischner Society 2017. Radiology 284:228\u2013243","journal-title":"Radiology"},{"key":"5889_CR18","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1002\/nbm.3161","volume":"27","author":"M Weiger","year":"2014","unstructured":"Weiger M, Wu M, Wurnig MC et al (2014) Rapid and robust pulmonary proton ZTE imaging in the mouse. NMR Biomed 27:1129\u20131134","journal-title":"NMR Biomed"},{"key":"5889_CR19","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1002\/mrm.20796","volume":"55","author":"PT Gurney","year":"2006","unstructured":"Gurney PT, Hargreaves BA, Nishimura DG (2006) Design and analysis of a practical 3D cones trajectory. Magn Reson Med 55:575\u2013582","journal-title":"Magn Reson Med"},{"key":"5889_CR20","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1002\/nbm.3417","volume":"28","author":"A Bianchi","year":"2015","unstructured":"Bianchi A, Tibiletti M, Kj\u00f8rstad \u00c5 et al (2015) Three-dimensional accurate detection of lung emphysema in rats using ultra-short and zero echo time MRI. NMR Biomed 28:1471\u20131479","journal-title":"NMR Biomed"},{"key":"5889_CR21","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1002\/jmri.25420","volume":"45","author":"T Niwa","year":"2017","unstructured":"Niwa T, Nozawa K, Aida N (2017) Visualization of the airway in infants with MRI using pointwise encoding time reduction with radial acquisition (PETRA). J Magn Reson Imaging 45:839\u2013844","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR22","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1002\/mrm.22829","volume":"66","author":"J Yu","year":"2011","unstructured":"Yu J, Xue Y, Song HK (2011) Comparison of lung T2* during free-breathing at 1.5 T and 3.0 T with ultrashort echo time imaging. Magn Reson Med 66:248\u2013254","journal-title":"Magn Reson Med"},{"key":"5889_CR23","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0720-048X(98)00169-7","volume":"29","author":"H Hatabu","year":"1999","unstructured":"Hatabu H, Alsop DC, Listerud J, Bonnet M, Gefter WB (1999) T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol 29:245\u2013252","journal-title":"Eur J Radiol"},{"key":"5889_CR24","doi-asserted-by":"publisher","first-page":"2120","DOI":"10.1007\/s00330-008-1001-2","volume":"18","author":"H Koyama","year":"2008","unstructured":"Koyama H, Ohno Y, Kono A et al (2008) Quantitative and qualitative assessment of non-contrast-enhanced pulmonary MR imaging for management of pulmonary nodules in 161 subjects. Eur Radiol 18:2120\u20132131","journal-title":"Eur Radiol"},{"key":"5889_CR25","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s00432-017-2521-4","volume":"144","author":"M Meier-Schroers","year":"2018","unstructured":"Meier-Schroers M, Homsi R, Skowasch D et al (2018) Lung cancer screening with MRI: results of the first screening round. J Cancer Res Clin Oncol 144:117\u2013125","journal-title":"J Cancer Res Clin Oncol"},{"key":"5889_CR26","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1002\/jmri.25008","volume":"43","author":"Y Ohno","year":"2016","unstructured":"Ohno Y, Koyama H, Yoshikawa T et al (2016) Pulmonary high-resolution ultrashort TE MR imaging: comparison with thin-section standard- and low-dose computed tomography for the assessment of pulmonary parenchyma diseases. J Magn Reson Imaging 43:512\u2013532","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR27","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1148\/radiol.2015150489","volume":"278","author":"NS Burris","year":"2016","unstructured":"Burris NS, Johnson KM, Larson PE et al (2016) Detection of small pulmonary nodules with ultrashort echo time sequences in oncology patients by using a PET\/MR system. Radiology 278:239\u2013246","journal-title":"Radiology"},{"key":"5889_CR28","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1002\/mrm.25545","volume":"75","author":"F Wiesinger","year":"2016","unstructured":"Wiesinger F, Sacolick LI, Menini A et al (2016) Zero TE MR bone imaging in the head. Magn Reson Med 75:107\u2013114","journal-title":"Magn Reson Med"},{"key":"5889_CR29","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1002\/1522-2586(200102)13:2<288::AID-JMRI1041>3.0.CO;2-P","volume":"13","author":"DL Price","year":"2001","unstructured":"Price DL, De Wilde JP, Papadaki AM, Curran JS, Kitney RI (2001) Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T. J Magn Reson Imaging 13:288\u2013293","journal-title":"J Magn Reson Imaging"},{"key":"5889_CR30","doi-asserted-by":"publisher","first-page":"209","DOI":"10.2463\/mrms.mp.2016-0045","volume":"16","author":"C Matsuo-Hagiyama","year":"2017","unstructured":"Matsuo-Hagiyama C, Watanabe Y, Tanaka H et al (2017) Comparison of silent and conventional MR imaging for the evaluation of myelination in children. Magn Reson Med Sci 16:209\u2013216","journal-title":"Magn Reson Med Sci"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5889-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-018-5889-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-018-5889-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,12,12]],"date-time":"2019-12-12T19:08:47Z","timestamp":1576177727000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-018-5889-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,13]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["5889"],"URL":"https:\/\/doi.org\/10.1007\/s00330-018-5889-x","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,13]]},"assertion":[{"value":"2 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Kyung Nyeo Jeon.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare a relationship with GE Healthcare. GE Healthcare had provided them with 3D cones ultra-short TE research pulse. MJ Hwang and JS Lee are employees of GE Healthcare (GE Healthcare Research, Korea). GE Healthcare had no role in the design and performance of the study, data analyses, or data interpretation.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all patients in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 Prospective\u2022 Diagnostic or prognostic study\u2022 Performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}