{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T13:35:29Z","timestamp":1768829729397,"version":"3.49.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2019,2,25]],"date-time":"2019-02-25T00:00:00Z","timestamp":1551052800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s00330-019-06032-y","type":"journal-article","created":{"date-parts":[[2019,2,25]],"date-time":"2019-02-25T11:30:37Z","timestamp":1551094237000},"page":"4783-4793","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection"],"prefix":"10.1007","volume":"29","author":[{"given":"Domenico","family":"De Santis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo N.","family":"De Cecco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6164-5641","authenticated-orcid":false,"given":"U. Joseph","family":"Schoepf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John W.","family":"Nance","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ricardo T.","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brooke A.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Otani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian E.","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. Alan","family":"Turner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julian L.","family":"Wichmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marwen","family":"Eid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akos","family":"Varga-Szemes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damiano","family":"Caruso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharine L.","family":"Grant","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas J.","family":"Vogl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Laghi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moritz H.","family":"Albrecht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,2,25]]},"reference":[{"key":"6032_CR1","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1148\/radiol.2363041140","volume":"236","author":"R Ouwendijk","year":"2005","unstructured":"Ouwendijk R, de Vries M, Pattynama PM et al (2005) Imaging peripheral arterial disease: a randomized controlled trial comparing contrast-enhanced MR angiography and multi-detector row CT angiography. Radiology 236:1094\u20131103","journal-title":"Radiology"},{"key":"6032_CR2","doi-asserted-by":"publisher","first-page":"1261","DOI":"10.2214\/AJR.04.1296","volume":"185","author":"R Ouwendijk","year":"2005","unstructured":"Ouwendijk R, Kock MC, Visser K, Pattynama PM, de Haan MW, Hunink MG (2005) Interobserver agreement for the interpretation of contrast-enhanced 3D MR angiography and MDCT angiography in peripheral arterial disease. AJR Am J Roentgenol 185:1261\u20131267","journal-title":"AJR Am J Roentgenol"},{"key":"6032_CR3","doi-asserted-by":"publisher","first-page":"1590","DOI":"10.2214\/AJR.09.3550","volume":"194","author":"C Thomas","year":"2010","unstructured":"Thomas C, Korn A, Ketelsen D et al (2010) Automatic lumen segmentation in calcified plaques: dual-energy CT versus standard reconstructions in comparison with digital subtraction angiography. AJR Am J Roentgenol 194:1590\u20131595","journal-title":"AJR Am J Roentgenol"},{"key":"6032_CR4","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1097\/RLI.0b013e3182479c77","volume":"47","author":"WH Sommer","year":"2012","unstructured":"Sommer WH, Bamberg F, Johnson TR et al (2012) Diagnostic accuracy of dynamic computed tomographic angiographic of the lower leg in patients with critical limb ischemia. Invest Radiol 47:325\u2013331","journal-title":"Invest Radiol"},{"key":"6032_CR5","doi-asserted-by":"crossref","unstructured":"Sandgaard NC, Diederichsen AC, Petersen H, H\u00f8ilund-Carlsen PF, Mickley H (2012) Patients\u2019 views of cardiac computed tomography angiography compared with conventional coronary angiography. J Thorac Imaging 27:36\u201339","DOI":"10.1097\/RTI.0b013e3182108091"},{"key":"6032_CR6","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1148\/radiol.11110700","volume":"263","author":"R Iezzi","year":"2012","unstructured":"Iezzi R, Santoro M, Marano R et al (2012) Low-dose multidetector CT angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease. Radiology 263:287\u2013298","journal-title":"Radiology"},{"key":"6032_CR7","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1148\/radiol.2372040616","volume":"237","author":"MC Kock","year":"2005","unstructured":"Kock MC, Adriaensen ME, Pattynama PM et al (2005) DSA versus multi-detector row CT angiography in peripheral arterial disease: randomized controlled trial. Radiology 237:727\u2013737","journal-title":"Radiology"},{"key":"6032_CR8","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1148\/radiol.2451061280","volume":"245","author":"MH Heijenbrok-Kal","year":"2007","unstructured":"Heijenbrok-Kal MH, Kock MC, Hunink MG (2007) Lower extremity arterial disease: multidetector CT angiography meta-analysis. Radiology 245:433\u2013439","journal-title":"Radiology"},{"key":"6032_CR9","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.ejrad.2008.09.010","volume":"68","author":"F Schwarz","year":"2008","unstructured":"Schwarz F, Ruzsics B, Schoepf UJ et al (2008) Dual-energy CT of the heart--principles and protocols. Eur J Radiol 68:423\u2013433","journal-title":"Eur J Radiol"},{"key":"6032_CR10","doi-asserted-by":"publisher","first-page":"S54","DOI":"10.2214\/AJR.12.9208","volume":"199","author":"R Vliegenthart","year":"2012","unstructured":"Vliegenthart R, Pelgrim GJ, Ebersberger U, Rowe GW, Oudkerk M, Schoepf UJ (2012) Dual-energy CT of the heart. AJR Am J Roentgenol 199:S54\u2013S63","journal-title":"AJR Am J Roentgenol"},{"key":"6032_CR11","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1097\/RLI.0000000000000272","volume":"51","author":"MH Albrecht","year":"2016","unstructured":"Albrecht MH, Trommer J, Wichmann JL et al (2016) Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen. Invest Radiol 51:582\u2013590","journal-title":"Invest Radiol"},{"key":"6032_CR12","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1007\/s00330-006-0517-6","volume":"17","author":"TR Johnson","year":"2007","unstructured":"Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510\u20131517","journal-title":"Eur Radiol"},{"key":"6032_CR13","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1148\/radiol.12112455","volume":"264","author":"F Schwarz","year":"2012","unstructured":"Schwarz F, Nance JW Jr, Ruzsics B, Bastarrika G, Sterzik A, Schoepf UJ (2012) Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography. Radiology 264:700\u2013707","journal-title":"Radiology"},{"key":"6032_CR14","doi-asserted-by":"publisher","first-page":"6128","DOI":"10.1118\/1.3651475","volume":"38","author":"M Straten van","year":"2011","unstructured":"van Straten M, Schaap M, Dijkshoorn ML et al (2011) Automated bone removal in CT angiography: comparison of methods based on single energy and dual energy scans. Med Phys 38:6128\u20136137","journal-title":"Med Phys"},{"key":"6032_CR15","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1097\/RLI.0000000000000391","volume":"52","author":"M Mannil","year":"2017","unstructured":"Mannil M, Ramachandran J, Vittoria de Martini I et al (2017) Modified dual-energy algorithm for calcified plaque removal: evaluation in carotid computed tomography angiography and comparison with digital subtraction angiography. Invest Radiol 52:680\u2013685","journal-title":"Invest Radiol"},{"key":"6032_CR16","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1097\/RLI.0000000000000416","volume":"53","author":"D Santis De","year":"2018","unstructured":"De Santis D, Jin KN, Schoepf UJ et al (2018) Heavily calcified coronary arteries: advanced calcium subtraction improves luminal visualization and diagnostic confidence in dual-energy coronary computed tomography angiography. Invest Radiol 53:103\u2013109","journal-title":"Invest Radiol"},{"key":"6032_CR17","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1148\/radiol.14140244","volume":"273","author":"M Meyer","year":"2014","unstructured":"Meyer M, Haubenreisser H, Schoepf UJ et al (2014) Closing in on the K edge: coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second- versus a third-generation dual-source CT system. Radiology 273:373\u2013382","journal-title":"Radiology"},{"key":"6032_CR18","doi-asserted-by":"publisher","first-page":"4380","DOI":"10.1007\/s00330-016-4304-8","volume":"26","author":"S Mangold","year":"2016","unstructured":"Mangold S, De Cecco CN, Schoepf UJ et al (2016) A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography. Eur Radiol 26:4380\u20134389","journal-title":"Eur Radiol"},{"key":"6032_CR19","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1097\/RLI.0000000000000216","volume":"51","author":"JL Wichmann","year":"2016","unstructured":"Wichmann JL, Gillott MR, De Cecco CN et al (2016) Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy. Invest Radiol 51:139\u2013146","journal-title":"Invest Radiol"},{"key":"6032_CR20","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1148\/radiol.14132903","volume":"273","author":"N Saltybaeva","year":"2014","unstructured":"Saltybaeva N, Jafari ME, Hupfer M, Kalender WA (2014) Estimates of effective dose for CT scans of the lower extremities. Radiology 273:153\u2013159","journal-title":"Radiology"},{"key":"6032_CR21","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1007\/s00330-016-4422-3","volume":"27","author":"SS Martin","year":"2017","unstructured":"Martin SS, Albrecht MH, Wichmann JL et al (2017) Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement. Eur Radiol 27:705\u2013714","journal-title":"Eur Radiol"},{"key":"6032_CR22","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1148\/radiol.12120509","volume":"265","author":"TS Genders","year":"2012","unstructured":"Genders TS, Spronk S, Stijnen T, Steyerberg EW, Lesaffre E, Hunink MG (2012) Methods for calculating sensitivity and specificity of clustered data: a tutorial. Radiology 265:910\u2013916","journal-title":"Radiology"},{"key":"6032_CR23","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1007\/s00330-011-2063-0","volume":"21","author":"S Haneder","year":"2011","unstructured":"Haneder S, Attenberger UI, Riffel P, Henzler T, Schoenberg SO, Michaely HJ (2011) Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA. Eur Radiol 21:1452\u20131461","journal-title":"Eur Radiol"},{"key":"6032_CR24","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1161\/CIRCIMAGING.111.970814","volume":"5","author":"AW Pollak","year":"2012","unstructured":"Pollak AW, Norton PT, Kramer CM (2012) Multimodality imaging of lower extremity peripheral arterial disease: current role and future directions. Circ Cardiovasc Imaging 5:797\u2013807","journal-title":"Circ Cardiovasc Imaging"},{"key":"6032_CR25","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.jcmg.2016.09.030","volume":"10","author":"A Varga-Szemes","year":"2017","unstructured":"Varga-Szemes A, Wichmann JL, Schoepf UJ et al (2017) Accuracy of noncontrast quiescent-interval single-shot lower extremity MR angiography versus CT angiography for diagnosis of peripheral artery disease: comparison with digital subtraction angiography. JACC Cardiovasc Imaging 10:1116\u20131124","journal-title":"JACC Cardiovasc Imaging"},{"key":"6032_CR26","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/S0002-9610(99)00151-8","volume":"178","author":"E Ascher","year":"1999","unstructured":"Ascher E, Mazzariol F, Hingorani A, Salles-Cunha S, Gade P (1999) The use of duplex ultrasound arterial mapping as an alternative to conventional arteriography for primary and secondary infrapopliteal bypasses. Am J Surg 178:162\u2013165","journal-title":"Am J Surg"},{"key":"6032_CR27","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1093\/eurheartj\/ehx095","volume":"39","author":"V Aboyans","year":"2018","unstructured":"Aboyans V, Ricco JB, Bartelink MEL et al (2018) 2017 ESC guidelines on the diagnosis and treatment of peripheral arterial diseases, in collaboration with the European Society for Vascular Surgery (ESVS): document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries endorsed by: the European Stroke Organization (ESO) The Task Force for the Diagnosis and Treatment of Peripheral Arterial Diseases of the European Society of Cardiology (ESC) and of the European Society for Vascular Surgery (ESVS). Eur Heart J 39:763\u2013816","journal-title":"Eur Heart J"},{"key":"6032_CR28","first-page":"e686","volume":"135","author":"MD Gerhard-Herman","year":"2017","unstructured":"Gerhard-Herman MD, Gornik HL, Barrett C et al (2017) 2016 AHA\/ACC guideline on the management of patients with lower extremity peripheral artery disease: executive summary: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines. Circulation 135:e686\u2013e725","journal-title":"Circulation"},{"key":"6032_CR29","doi-asserted-by":"publisher","first-page":"3104","DOI":"10.1007\/s00330-013-2933-8","volume":"23","author":"S Jens","year":"2013","unstructured":"Jens S, Koelemay MJ, Reekers JA, Bipat S (2013) Diagnostic performance of computed tomography angiography and contrast-enhanced magnetic resonance angiography in patients with critical limb ischaemia and intermittent claudication: systematic review and meta-analysis. Eur Radiol 23:3104\u20133114","journal-title":"Eur Radiol"},{"key":"6032_CR30","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1002\/jmri.21416","volume":"28","author":"RP Lim","year":"2008","unstructured":"Lim RP, Hecht EM, Xu J et al (2008) 3D nongadolinium-enhanced ECG-gated MRA of the distal lower extremities: preliminary clinical experience. J Magn Reson Imaging 28:181\u2013189","journal-title":"J Magn Reson Imaging"},{"key":"6032_CR31","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1055\/s-0043-101526","volume":"189","author":"T Klink","year":"2017","unstructured":"Klink T, Wilhelm T, Roth C, Heverhagen JT (2017) Dual-energy CTA in patients with symptomatic peripheral arterial occlusive disease: study of diagnostic accuracy and impeding factors. Rofo 189:441\u2013452","journal-title":"Rofo"},{"key":"6032_CR32","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.rcl.2018.03.010","volume":"56","author":"D Santis De","year":"2018","unstructured":"De Santis D, Eid M, De Cecco CN et al (2018) Dual-energy computed tomography in cardiothoracic vascular imaging. Radiol Clin North Am 56:521\u2013534","journal-title":"Radiol Clin North Am"},{"key":"6032_CR33","doi-asserted-by":"publisher","first-page":"1863","DOI":"10.1007\/s00330-015-3970-2","volume":"26","author":"MH Albrecht","year":"2016","unstructured":"Albrecht MH, Scholtz JE, H\u00fcsers K et al (2016) Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast. Eur Radiol 26:1863\u20131870","journal-title":"Eur Radiol"},{"key":"6032_CR34","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1016\/j.ejrad.2008.09.016","volume":"68","author":"BC Meyer","year":"2008","unstructured":"Meyer BC, Werncke T, Hopfenmuller W, Raatschen HJ, Wolf KJ, Albrecht T (2008) Dual energy CT of peripheral arteries: effect of automatic bone and plaque removal on image quality and grading of stenoses. Eur J Radiol 68:414\u2013422","journal-title":"Eur J Radiol"},{"key":"6032_CR35","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.acra.2008.09.004","volume":"16","author":"DN Tran","year":"2009","unstructured":"Tran DN, Straka M, Roos JE, Napel S, Fleischmann D (2009) Dual-energy CT discrimination of iodine and calcium: experimental results and implications for lower extremity CT angiography. Acad Radiol 16:160\u2013171","journal-title":"Acad Radiol"},{"key":"6032_CR36","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1055\/s-0029-1245268","volume":"182","author":"T Werncke","year":"2010","unstructured":"Werncke T, Albrecht T, Wolf KJ, Meyer BC (2010) Dual energy CT of the peripheral arteries: a phantom study to assess the effect of automatic plaque removal on stenosis grading. Rofo 182:682\u2013689","journal-title":"Rofo"},{"key":"6032_CR37","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/RLI.0b013e31819b70ba","volume":"44","author":"WH Sommer","year":"2009","unstructured":"Sommer WH, Johnson TR, Becker CR et al (2009) The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography. Invest Radiol 44:285\u2013292","journal-title":"Invest Radiol"},{"key":"6032_CR38","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1001\/jama.301.4.415","volume":"301","author":"R Met","year":"2009","unstructured":"Met R, Bipat S, Legemate DA, Reekers JA, Koelemay MJ (2009) Diagnostic performance of computed tomography angiography in peripheral arterial disease: a systematic review and meta-analysis. JAMA 301:415\u2013424","journal-title":"JAMA"},{"key":"6032_CR39","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.2214\/AJR.09.3538","volume":"194","author":"SG Naidu","year":"2010","unstructured":"Naidu SG, Hara AK, Brandis AR, Stone WM (2010) Incidence of highly important extravascular findings detected on CT angiography of the abdominal aorta and the lower extremities. AJR Am J Roentgenol 194:1630\u20131634","journal-title":"AJR Am J Roentgenol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-019-06032-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06032-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06032-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,24]],"date-time":"2020-02-24T19:08:07Z","timestamp":1582571287000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-019-06032-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,25]]},"references-count":39,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["6032"],"URL":"https:\/\/doi.org\/10.1007\/s00330-019-06032-y","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,25]]},"assertion":[{"value":"7 August 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Prof. U. Joseph Schoepf.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: U.J.S. receives institutional research support from Astellas, Bayer, General Electric, and Siemens Healthineers. U.J.S. has received honoraria for speaking and consulting from Bayer, Guerbet, HeartFlow Inc., and Siemens Healthineers. C.N.D.C. receives institutional research support from Siemens Healthineers and speaking fees from Bayer. A.V.S. receives institutional research support from Siemens Healthineers. J.L.W. received speaking fees from Siemens Healthineers and General Electric. K.O., K.L.G., and B.S. are employees of Siemens Healthineers. M.H.A. received speaking fees from Siemens Healthineers and Bracco. All other authors declare that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 retrospective\u2022 diagnostic or prognostic study\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}