{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T08:32:10Z","timestamp":1781512330232,"version":"3.54.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s00330-019-06264-y","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T14:51:11Z","timestamp":1560264671000},"page":"6991-6999","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Screening outcome for consecutive examinations with digital breast tomosynthesis versus standard digital mammography in a population-based screening program"],"prefix":"10.1007","volume":"29","author":[{"given":"Tone","family":"Hovda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siri H. B.","family":"Brandal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sofie","family":"Sebu\u00f8deg\u00e5rd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c5sne S.","family":"Holen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hilde","family":"Bj\u00f8rndal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Per","family":"Skaane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0178-8939","authenticated-orcid":false,"given":"Solveig","family":"Hofvind","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,11]]},"reference":[{"key":"6264_CR1","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.crad.2015.11.008","volume":"71","author":"FJ Gilbert","year":"2016","unstructured":"Gilbert FJ, Tucker L, Young KC (2016) Digital breast tomosynthesis (DBT): a review of the evidence for use as a screening tool. Clin Radiol 71:141\u2013150","journal-title":"Clin Radiol"},{"key":"6264_CR2","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1093\/jnci\/djy121","volume":"110","author":"ML Marinovich","year":"2018","unstructured":"Marinovich ML, Hunter KE, Macaskill P, Houssami N (2018) Breast cancer screening using tomosynthesis or mammography: a meta-analysis of cancer detection and recall. J Natl Cancer Inst 110:942\u2013949","journal-title":"J Natl Cancer Inst"},{"key":"6264_CR3","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1001\/jama.2014.6095","volume":"311","author":"SM Friedewald","year":"2014","unstructured":"Friedewald SM, Rafferty EA, Rose SL et al (2014) Breast cancer screening using tomosynthesis in combination with digital mammography. JAMA 311:2499\u20132507","journal-title":"JAMA"},{"key":"6264_CR4","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1148\/radiol.12121373","volume":"267","author":"P Skaane","year":"2013","unstructured":"Skaane P, Bandos AI, Gullien R et al (2013) Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 267:47\u201356","journal-title":"Radiology"},{"key":"6264_CR5","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1016\/S1470-2045(16)30101-2","volume":"17","author":"D Bernardi","year":"2016","unstructured":"Bernardi D, Macaskill P, Pellegrini M et al (2016) Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study. Lancet Oncol 17:1105\u20131113","journal-title":"Lancet Oncol"},{"key":"6264_CR6","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/S1470-2045(13)70134-7","volume":"14","author":"S Ciatto","year":"2013","unstructured":"Ciatto S, Houssami N, Bernardi D et al (2013) Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Lancet Oncol 14:583\u2013589","journal-title":"Lancet Oncol"},{"issue":"11","key":"6264_CR7","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1016\/S1470-2045(18)30521-7","volume":"19","author":"Sophia Zackrisson","year":"2018","unstructured":"Zackrisson S, L\u00e5ng K, Rosso A et al (2018) One-view breast tomosynthesis versus two-view mammography in the Malmo Breast Tomosynthesis Screening Trial (MBTST): a prospective, population-based, diagnostic accuracy study. Lancet Oncol. \nhttps:\/\/doi.org\/10.1016\/S1470-2045(18)30521-7","journal-title":"The Lancet Oncology"},{"key":"6264_CR8","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1007\/s10549-018-4705-2","volume":"169","author":"P Skaane","year":"2018","unstructured":"Skaane P, Sebu\u00f8deg\u00e5rd S, Bandos AI et al (2018) Performance of breast cancer screening using digital breast tomosynthesis: results from the prospective population-based Oslo Tomosynthesis Screening Trial. Breast Cancer Res Treat 169:489\u2013496","journal-title":"Breast Cancer Res Treat"},{"key":"6264_CR9","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.breast.2018.01.002","volume":"38","author":"N Houssami","year":"2018","unstructured":"Houssami N, Bernardi D, Caumo F et al (2018) Interval breast cancers in the 'screening with tomosynthesis or standard mammography' (STORM) population-based trial. Breast 38:150\u2013153","journal-title":"Breast"},{"issue":"S1","key":"6264_CR10","doi-asserted-by":"publisher","first-page":"S-3-S-11","DOI":"10.1089\/pop.2015.29023.mor","volume":"18","author":"Elizabeth Morris","year":"2015","unstructured":"Morris E, Feig SA, Drexler M, Lehman C (2015) Implications of overdiagnosis: impact on screening mammography practices. Popul Health Manag 18(Suppl 1):S3\u2013S11","journal-title":"Population Health Management"},{"key":"6264_CR11","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1148\/radiol.2015142566","volume":"277","author":"FJ Gilbert","year":"2015","unstructured":"Gilbert FJ, Tucker L, Gillan MG et al (2015) Accuracy of digital breast tomosynthesis for depicting breast cancer subgroups in a UK retrospective reading study (TOMMY trial). Radiology 277:697\u2013706","journal-title":"Radiology"},{"key":"6264_CR12","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1148\/radiol.13131391","volume":"271","author":"P Skaane","year":"2014","unstructured":"Skaane P, Bandos AI, Eben EB et al (2014) Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images. Radiology 271:655\u2013663","journal-title":"Radiology"},{"issue":"3","key":"6264_CR13","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s10549-017-4458-3","volume":"166","author":"Giovanna Mariscotti","year":"2017","unstructured":"Mariscotti G, Durando M, Houssami N et al (2017) Comparison of synthetic mammography, reconstructed from digital breast tomosynthesis, and digital mammography: evaluation of lesion conspicuity and BI-RADS assessment categories. Breast Cancer Res Treat. \nhttps:\/\/doi.org\/10.1007\/s10549-017-4458-3","journal-title":"Breast Cancer Research and Treatment"},{"key":"6264_CR14","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1148\/radiol.2016160366","volume":"281","author":"SP Zuckerman","year":"2016","unstructured":"Zuckerman SP, Conant EF, Keller BM et al (2016) Implementation of synthesized two-dimensional mammography in a population-based digital breast tomosynthesis screening program. Radiology 281:730\u2013736","journal-title":"Radiology"},{"key":"6264_CR15","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1001\/jamaoncol.2015.5536","volume":"2","author":"ES McDonald","year":"2016","unstructured":"McDonald ES, Oustimov A, Weinstein SP, Synnestvedt MB, Schnall M, Conant EF (2016) Effectiveness of digital breast tomosynthesis compared with digital mammography: outcomes analysis from 3 years of breast cancer screening. JAMA Oncol 2:737\u2013743","journal-title":"JAMA Oncol"},{"issue":"3","key":"6264_CR16","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1007\/s00330-018-5690-x","volume":"29","author":"Hildegunn S. Aase","year":"2018","unstructured":"Aase HS, Holen \u00c5S, Pedersen K et al (2018) A randomized controlled trial of digital breast tomosynthesis versus digital mammography in population-based screening in Bergen: interim analysis of performance indicators from the To-Be trial. Eur Radiol. \nhttps:\/\/doi.org\/10.1007\/s00330-018-5690-x","journal-title":"European Radiology"},{"key":"6264_CR17","doi-asserted-by":"publisher","unstructured":"Hofvind S, Hovda T, Holen \u00c5S et al (2018) Digital breast tomosynthesis and synthetic 2D mammography versus digital mammography: evaluation in a population-based screening program. Radiology. \nhttps:\/\/doi.org\/10.1148\/radiol.2018171361:171361","DOI":"10.1148\/radiol.2018171361:171361"},{"key":"6264_CR18","unstructured":"Hofvind S, Tsuruda K, Mangerud G et al (2017) The Norwegian Breast Cancer Screening Program, 1996-2016: Celebrating 20 years of organised mammographic screening. In: Cancer in Norway 2016 - Cancer incidence, mortality, survival and prevalence in Norway. Oslo: Cancer Registry of Norway"},{"key":"6264_CR19","unstructured":"Ministry of Health and Care Services (2001) Forskrift om innsamling og behandling av helseopplysninger i Kreftregisteret (The Cancer Registry Regulation) Available via \nhttps:\/\/lovdata.no\/dokument\/SF\/forskrift\/2001-12-21-1477\n\n. Accessed 10 April 2019"},{"key":"6264_CR20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1148\/radiol.2017162159","volume":"287","author":"S Hofvind","year":"2018","unstructured":"Hofvind S, Sagstad S, Sebu\u00f8deg\u00e5rd S, Chen Y, Roman M, Lee CI (2018) Interval breast cancer rates and histopathologic tumor characteristics after false-positive findings at mammography in a population-based screening program. Radiology 287:58\u201367","journal-title":"Radiology"},{"key":"6264_CR21","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1148\/radiol.2018172119","volume":"288","author":"P Pattacini","year":"2018","unstructured":"Pattacini P, Nitrosi A, Giorgi Rossi P et al (2018) Digital mammography versus digital mammography plus tomosynthesis for breast cancer screening: the Reggio Emilia Tomosynthesis Randomized Trial. Radiology 288:375\u2013385","journal-title":"Radiology"},{"key":"6264_CR22","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.ejrad.2018.07.008","volume":"106","author":"D Bernardi","year":"2018","unstructured":"Bernardi D, Li T, Pellegrini M et al (2018) Effect of integrating digital breast tomosynthesis (3D-mammography) with acquired or synthetic 2D-mammography on radiologists\u2019 true-positive and false-positive detection in a population screening trial: a descriptive study. Eur J Radiol 106:26\u201331","journal-title":"Eur J Radiol"},{"key":"6264_CR23","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1177\/0969141317733771","volume":"25","author":"S Bhargava","year":"2018","unstructured":"Bhargava S, Tsuruda K, Moen K, Bukholm I, Hofvind S (2018) Lower attendance rates in immigrant versus non-immigrant women in the Norwegian Breast Cancer Screening Programme. J Med Screen 25:155\u2013161","journal-title":"J Med Screen"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06264-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-019-06264-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06264-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,9]],"date-time":"2020-06-09T23:09:15Z","timestamp":1591744155000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-019-06264-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,11]]},"references-count":23,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["6264"],"URL":"https:\/\/doi.org\/10.1007\/s00330-019-06264-y","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,11]]},"assertion":[{"value":"21 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 May 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Prof. Solveig Hofvind.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article. SH is the Head of BreastScreen Norway, but has permanent employment as a researcher at the Cancer Registry of Norway, independent of her job as administrative leader of BreastScreen Norway.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.The Cancer Registry Regulation gives approval with waiver of informed consent to perform surveillance, quality assurance, and studies based on data collected as a part of invitation to and participation in the program.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained. Data was collected from BreastScreen Norway and thus covered by the Cancer Registry Regulation. Data from the Oslo Tomosynthesis Study Trial, as a part of BreastScreen Norway, was also approved by the regional ethical committee and data from the Oslo-Vestre-Viken-Vestfold study was approved by the institutional Data Protection Officer.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Some study subjects or cohorts have been included in previously published papers\u2014the Oslo Tomosynthesis Trial and the Oslo-Vestfold-VestreViken study.Skaane P, Bandos AI, Gullien R et al (2013) Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 267:47\u201356.Hofvind S, Hovda T, Holen \u00c5S et al (2018) Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Digital Mammography: Evaluation in a Population-based Screening Program. Radiology.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 Retrospective\u2022 Observational\u2022 Performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}