{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T02:48:50Z","timestamp":1777344530155,"version":"3.51.4"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2019,6,7]],"date-time":"2019-06-07T00:00:00Z","timestamp":1559865600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,7]],"date-time":"2019-06-07T00:00:00Z","timestamp":1559865600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s00330-019-06278-6","type":"journal-article","created":{"date-parts":[[2019,6,7]],"date-time":"2019-06-07T15:02:36Z","timestamp":1559919756000},"page":"6858-6866","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Wide-volume versus helical acquisition in unenhanced chest CT: prospective intra-patient comparison of diagnostic accuracy and radiation dose in an ultra-low-dose setting"],"prefix":"10.1007","volume":"29","author":[{"given":"Elsa","family":"Meyer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aissam","family":"Labani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Micka\u00ebl","family":"Schaeffer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mi-Young","family":"Jeung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claire","family":"Ludes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alain","family":"Meyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catherine","family":"Roy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Leyendecker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0179-5784","authenticated-orcid":false,"given":"Micka\u00ebl","family":"Ohana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,7]]},"reference":[{"key":"6278_CR1","doi-asserted-by":"publisher","first-page":"k4931","DOI":"10.1136\/bmj.k4931","volume":"364","author":"R Smith-Bindman","year":"2019","unstructured":"Smith-Bindman R, Wang Y, Chu P et al (2019) International variation in radiation dose for computed tomography examinations: prospective cohort study. BMJ 364:k4931","journal-title":"BMJ"},{"key":"6278_CR2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.pneumo.2016.09.007","volume":"73","author":"M Ohana","year":"2017","unstructured":"Ohana M, Ludes C, Schaal M et al (2017) What future for chest x-ray against ultra-low-dose computed tomography? Rev Pneumol Clin 73:3\u201312","journal-title":"Rev Pneumol Clin"},{"key":"6278_CR3","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.lpm.2015.12.003","volume":"45","author":"C Ludes","year":"2016","unstructured":"Ludes C, Schaal M, Labani A, Jeung MY, Roy C, Ohana M (2016) Ultra-low dose chest CT: the end of chest radiograph. Presse Med 45:291\u2013301","journal-title":"Presse Med"},{"issue":"11","key":"6278_CR4","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1016\/j.acra.2019.01.002","volume":"26","author":"Nirali Patel","year":"2019","unstructured":"Patel N, Li D, Nakanishi R et al (2019) Comparison of whole heart computed tomography scanners for image quality lower radiation dosing in coronary computed tomography angiography: the CONVERGE registry. Acad Radiol. \nhttps:\/\/doi.org\/10.1016\/j.acra.2019.01.002","journal-title":"Academic Radiology"},{"key":"6278_CR5","doi-asserted-by":"publisher","first-page":"e0204145","DOI":"10.1371\/journal.pone.0204145","volume":"13","author":"D Mata-Mbemba","year":"2018","unstructured":"Mata-Mbemba D, Labani A, El Ghannudi S et al (2018) 320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection. PLoS One 13:e0204145","journal-title":"PLoS One"},{"key":"6278_CR6","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1016\/j.diii.2018.05.009","volume":"99","author":"C Roy","year":"2018","unstructured":"Roy C, Quin R, Labani A, Leyendecker P, Mertz L, Ohana M (2018) Wide volume versus helical acquisition using 320-detector row computed tomography for computed tomography urography in adults. Diagn Interv Imaging 99:653\u2013662","journal-title":"Diagn Interv Imaging"},{"key":"6278_CR7","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.diii.2012.05.017","volume":"94","author":"A Gervaise","year":"2013","unstructured":"Gervaise A, Teixeira P, Villani N, Lecocq S, Louis M, Blum A (2013) CT dose optimisation and reduction in osteoarticular disease. Diagn Interv Imaging 94:371\u2013388","journal-title":"Diagn Interv Imaging"},{"issue":"Suppl 1","key":"6278_CR8","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/s10554-012-0072-y","volume":"28","author":"EJ Kang","year":"2012","unstructured":"Kang EJ, Lee KN, Kim DW et al (2012) Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes. Int J Cardiovasc Imaging 28(Suppl 1):7\u201313","journal-title":"Int J Cardiovasc Imaging"},{"key":"6278_CR9","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1007\/s00330-011-2088-4","volume":"21","author":"T Durmus","year":"2011","unstructured":"Durmus T, Rogalla P, Lembcke A, Muhler MR, Hamm B, Hein PA (2011) Low-dose triple-rule-out using 320-row-detector volume MDCT-less contrast medium and lower radiation exposure. Eur Radiol 21:1416\u20131423","journal-title":"Eur Radiol"},{"key":"6278_CR10","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ejrad.2010.05.014","volume":"80","author":"K Kitajima","year":"2011","unstructured":"Kitajima K, Maeda T, Ohno Y et al (2011) Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT. Eur J Radiol 80:219\u2013223","journal-title":"Eur J Radiol"},{"key":"6278_CR11","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1097\/RCT.0b013e318260941a","volume":"36","author":"O Honda","year":"2012","unstructured":"Honda O, Takenaka D, Matsuki M et al (2012) Image quality of 320-detector row wide-volume computed tomography with diffuse lung diseases: comparison with 64-detector row helical CT. J Comput Assist Tomogr 36:505\u2013511","journal-title":"J Comput Assist Tomogr"},{"key":"6278_CR12","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1148\/radiol.2462070712","volume":"246","author":"DM Hansell","year":"2008","unstructured":"Hansell DM, Bankier AA, MacMahon H, McLoud TC, Muller NL, Remy J (2008) Fleischner society: glossary of terms for thoracic imaging. Radiology 246:697\u2013722","journal-title":"Radiology"},{"key":"6278_CR13","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1148\/radiol.2483071964","volume":"248","author":"W Huda","year":"2008","unstructured":"Huda W, Ogden KM, Khorasani MR (2008) Converting dose-length product to effective dose at CT. Radiology 248:995\u20131003","journal-title":"Radiology"},{"key":"6278_CR14","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.3348\/kjr.2015.16.5.1132","volume":"16","author":"HJ Yoon","year":"2015","unstructured":"Yoon HJ, Chung MJ, Hwang HS, Moon JW, Lee KS (2015) Adaptive statistical iterative reconstruction-applied ultra-low-dose CT with radiography-comparable radiation dose: usefulness for lung nodule detection. Korean J Radiol 16:1132\u20131141","journal-title":"Korean J Radiol"},{"key":"6278_CR15","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1007\/s00330-012-2627-7","volume":"23","author":"A Neroladaki","year":"2013","unstructured":"Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X (2013) Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol 23:360\u2013366","journal-title":"Eur Radiol"},{"key":"6278_CR16","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1007\/s00330-013-3090-9","volume":"24","author":"SW Lee","year":"2014","unstructured":"Lee SW, Kim Y, Shim SS et al (2014) Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction. Eur Radiol 24:817\u2013826","journal-title":"Eur Radiol"},{"key":"6278_CR17","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.1016\/j.ejrad.2015.03.012","volume":"84","author":"Y Nagatani","year":"2015","unstructured":"Nagatani Y, Takahashi M, Murata K et al (2015) Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis. Eur J Radiol 84:1401\u20131412","journal-title":"Eur J Radiol"},{"key":"6278_CR18","doi-asserted-by":"publisher","first-page":"3290","DOI":"10.1007\/s00330-017-4739-6","volume":"27","author":"M Messerli","year":"2017","unstructured":"Messerli M, Kluckert T, Knitel M et al (2017) Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose - a prospective intra-individual comparative study. Eur Radiol 27:3290\u20133299","journal-title":"Eur Radiol"},{"key":"6278_CR19","doi-asserted-by":"publisher","first-page":"393","DOI":"10.4143\/crt.2013.132","volume":"46","author":"HJ Kim","year":"2014","unstructured":"Kim HJ, Park SY, Lee HY, Lee KS, Shin KE, Moon JW (2014) Ultra-low-dose chest CT in patients with neutropenic fever and hematologic malignancy: image quality and its diagnostic performance. Cancer Res Treat 46:393\u2013402","journal-title":"Cancer Res Treat"},{"key":"6278_CR20","doi-asserted-by":"publisher","first-page":"743","DOI":"10.2214\/AJR.14.13101","volume":"204","author":"R Wang","year":"2015","unstructured":"Wang R, Sui X, Schoepf UJ et al (2015) Ultralow-radiation-dose chest CT: accuracy for lung densitometry and emphysema detection. AJR Am J Roentgenol 204:743\u2013749","journal-title":"AJR Am J Roentgenol"},{"key":"6278_CR21","doi-asserted-by":"publisher","first-page":"e004980","DOI":"10.1136\/bmjopen-2014-004980","volume":"4","author":"M Tekath","year":"2014","unstructured":"Tekath M, Dutheil F, Bellini R et al (2014) Comparison of the ultra-low-dose Veo algorithm with the gold standard filtered back projection for detecting pulmonary asbestos-related conditions: a clinical observational study. BMJ Open 4:e004980","journal-title":"BMJ Open"},{"key":"6278_CR22","doi-asserted-by":"publisher","first-page":"e0168979","DOI":"10.1371\/journal.pone.0168979","volume":"11","author":"M Schaal","year":"2016","unstructured":"Schaal M, Severac F, Labani A, Jeung MY, Roy C, Ohana M (2016) Diagnostic performance of ultra-low-dose computed tomography for detecting Asbestos-related pleuropulmonary diseases: prospective study in a screening setting. PLoS One 11:e0168979","journal-title":"PLoS One"},{"key":"6278_CR23","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.diii.2018.11.012","volume":"100","author":"C Ludes","year":"2019","unstructured":"Ludes C, Labani A, Severac F et al (2019) Ultra-low-dose unenhanced chest CT: prospective comparison of high kV\/low mA versus low kV\/high mA protocols. Diagn Interv Imaging 100:85\u201393","journal-title":"Diagn Interv Imaging"},{"key":"6278_CR24","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/S0221-0363(10)70115-3","volume":"91","author":"A Gervaise","year":"2010","unstructured":"Gervaise A, Louis M, Batch T et al (2010) Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results. J Radiol 91:779\u2013785","journal-title":"J Radiol"},{"key":"6278_CR25","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1007\/s00330-008-1255-8","volume":"19","author":"PA Hein","year":"2009","unstructured":"Hein PA, Romano VC, Lembcke A, May J, Rogalla P (2009) Initial experience with a chest pain protocol using 320-slice volume MDCT. Eur Radiol 19:1148\u20131155","journal-title":"Eur Radiol"},{"key":"6278_CR26","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1007\/s00247-013-2690-5","volume":"43","author":"JH Johnston","year":"2013","unstructured":"Johnston JH, Podberesky DJ, Yoshizumi TT et al (2013) Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT. Pediatr Radiol 43:1117\u20131127","journal-title":"Pediatr Radiol"},{"key":"6278_CR27","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1148\/radiol.2322031304","volume":"232","author":"MK Kalra","year":"2004","unstructured":"Kalra MK, Maher MM, Toth TL, Kamath RS, Halpern EF, Saini S (2004) Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology 232:347\u2013353","journal-title":"Radiology"},{"key":"6278_CR28","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.acra.2011.12.001","volume":"19","author":"T Yamashiro","year":"2012","unstructured":"Yamashiro T, Miyara T, Takahashi M et al (2012) Lung image quality with 320-row wide-volume CT scans: the effect of prospective ECG-gating and comparisons with 64-row helical CT scans. Acad Radiol 19:380\u2013388","journal-title":"Acad Radiol"},{"key":"6278_CR29","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1148\/rg.304095167","volume":"30","author":"A Schilham","year":"2010","unstructured":"Schilham A, van der Molen AJ, Prokop M, de Jong HW (2010) Overranging at multisection CT: an underestimated source of excess radiation exposure. Radiographics 30:1057\u20131067","journal-title":"Radiographics"},{"key":"6278_CR30","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.1016\/j.ejrad.2011.12.001","volume":"82","author":"E Sorantin","year":"2013","unstructured":"Sorantin E, Riccabona M, Stucklschweiger G, Guss H, Fotter R (2013) Experience with volumetric (320 rows) pediatric CT. Eur J Radiol 82:1091\u20131097","journal-title":"Eur J Radiol"},{"key":"6278_CR31","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.radmeas.2013.04.012","volume":"56","author":"Y.L. Liao","year":"2013","unstructured":"Liao YL, Lai NK, Tyan YS, Chuang KS, Tsai HY (2013) Automatic tube current modulation for volume scan in a 320-detector row CT scanner. Radiat Meas 328\u2013332. \nhttps:\/\/doi.org\/10.1016\/j.radmeas.2013.04.012","journal-title":"Radiation Measurements"},{"issue":"8","key":"6278_CR32","doi-asserted-by":"publisher","first-page":"4315","DOI":"10.1007\/s00330-018-5849-5","volume":"29","author":"Tony M. Svahn","year":"2018","unstructured":"Svahn TM, Sjoberg T, Ast JC (2018) Dose estimation of ultra-low-dose chest CT to different sized adult patients. Eur Radiol. \nhttps:\/\/doi.org\/10.1007\/s00330-018-5849-5","journal-title":"European Radiology"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06278-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-019-06278-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06278-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,5]],"date-time":"2020-06-05T23:15:51Z","timestamp":1591398951000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-019-06278-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,7]]},"references-count":32,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["6278"],"URL":"https:\/\/doi.org\/10.1007\/s00330-019-06278-6","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,7]]},"assertion":[{"value":"5 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 June 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Micka\u00ebl Ohana.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise: Dr. Micka\u00ebl Schaeffer is a biostatistician.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 Prospective\u2022 Case-control study\u2022 Performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}