{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T10:54:32Z","timestamp":1781261672174,"version":"3.54.1"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T00:00:00Z","timestamp":1576800000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T00:00:00Z","timestamp":1576800000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s00330-019-06554-5","type":"journal-article","created":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T08:05:16Z","timestamp":1576829116000},"page":"2241-2252","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["MRI with state-of-the-art metal artifact reduction after total hip arthroplasty: periprosthetic findings in asymptomatic and symptomatic patients"],"prefix":"10.1007","volume":"30","author":[{"given":"Lukas","family":"Filli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pia M.","family":"Jungmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick O.","family":"Zingg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannes A.","family":"R\u00fcdiger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julien","family":"Galley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reto","family":"Sutter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian W. A.","family":"Pfirrmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,20]]},"reference":[{"key":"6554_CR1","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1055\/s-0034-1396765","volume":"19","author":"AJ Burge","year":"2015","unstructured":"Burge AJ (2015) Total hip arthroplasty: MR imaging of complications unrelated to metal wear. Semin Musculoskelet Radiol 19:31\u201339","journal-title":"Semin Musculoskelet Radiol"},{"key":"6554_CR2","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1148\/radiology.215.1.r00ap11254","volume":"215","author":"LM White","year":"2000","unstructured":"White LM, Kim JK, Mehta M et al (2000) Complications of total hip arthroplasty: MR imaging-initial experience. Radiology 215:254\u2013262","journal-title":"Radiology"},{"key":"6554_CR3","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1056\/NEJMcp0905029","volume":"361","author":"JL Del Pozo","year":"2009","unstructured":"Del Pozo JL, Patel R (2009) Clinical practice. Infection associated with prosthetic joints. N Engl J Med 361:787\u2013794","journal-title":"N Engl J Med"},{"key":"6554_CR4","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1148\/rg.324115183","volume":"32","author":"TD Roth","year":"2012","unstructured":"Roth TD, Maertz NA, Parr JA, Buckwalter KA, Choplin RH (2012) CT of the hip prosthesis: appearance of components, fixation, and complications. Radiographics 32:1089\u20131107","journal-title":"Radiographics"},{"key":"6554_CR5","doi-asserted-by":"publisher","first-page":"570","DOI":"10.2214\/AJR.12.8844","volume":"199","author":"H Mulcahy","year":"2012","unstructured":"Mulcahy H, Chew FS (2012) Current concepts of hip arthroplasty for radiologists: part 2, revisions and complications. AJR Am J Roentgenol 199:570\u2013580","journal-title":"AJR Am J Roentgenol"},{"key":"6554_CR6","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1002\/jmri.23523","volume":"35","author":"CL Hayter","year":"2012","unstructured":"Hayter CL, Koff MF, Potter HG (2012) Magnetic resonance imaging of the postoperative hip. J Magn Reson Imaging 35:1013\u20131025","journal-title":"J Magn Reson Imaging"},{"key":"6554_CR7","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.crad.2007.07.012","volume":"63","author":"AP Toms","year":"2008","unstructured":"Toms AP, Marshall TJ, Cahir J et al (2008) MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips. Clin Radiol 63:49\u201358","journal-title":"Clin Radiol"},{"key":"6554_CR8","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1055\/s-0035-1563735","volume":"19","author":"CY Chang","year":"2015","unstructured":"Chang CY, Huang AJ, Palmer WE (2015) Radiographic evaluation of hip implants. Semin Musculoskelet Radiol 19:12\u201320","journal-title":"Semin Musculoskelet Radiol"},{"key":"6554_CR9","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/00002142-199908000-00003","volume":"10","author":"C Czerny","year":"1999","unstructured":"Czerny C, Krestan C, Imhof H, Trattnig S (1999) Magnetic resonance imaging of the postoperative hip. Top Magn Reson Imaging 10:214\u2013220","journal-title":"Top Magn Reson Imaging"},{"key":"6554_CR10","doi-asserted-by":"publisher","unstructured":"Otazo R, Nittka M, Bruno M et al (2016) Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration. Magn Reson Med. https:\/\/doi.org\/10.1002\/mrm.26342","DOI":"10.1002\/mrm.26342"},{"issue":"361-373","key":"6554_CR11","first-page":"vi","volume":"37","author":"HG Potter","year":"2006","unstructured":"Potter HG, Foo LF (2006) Magnetic resonance imaging of joint arthroplasty. Orthop Clin North Am 37(361-373):vi\u2013vii","journal-title":"Orthop Clin North Am"},{"key":"6554_CR12","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1016\/j.orthres.2005.02.007","volume":"23","author":"DE Weiland","year":"2005","unstructured":"Weiland DE, Walde TA, Leung SB et al (2005) Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: a cadaveric study. J Orthop Res 23:713\u2013719","journal-title":"J Orthop Res"},{"key":"6554_CR13","doi-asserted-by":"crossref","unstructured":"Walde TA, Weiland DE, Leung SB et al (2005) Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study. Clin Orthop Relat Res:138\u2013144","DOI":"10.1097\/01.blo.0000164028.14504.46"},{"key":"6554_CR14","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1148\/radiol.2353040403","volume":"235","author":"CW Pfirrmann","year":"2005","unstructured":"Pfirrmann CW, Notzli HP, Dora C, Hodler J, Zanetti M (2005) Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients. Radiology 235:969\u2013976","journal-title":"Radiology"},{"key":"6554_CR15","doi-asserted-by":"publisher","first-page":"E106","DOI":"10.1148\/rg.344140010","volume":"34","author":"J Fritz","year":"2014","unstructured":"Fritz J, Lurie B, Miller TT, Potter HG (2014) MR imaging of hip arthroplasty implants. Radiographics 34:E106\u2013E132","journal-title":"Radiographics"},{"key":"6554_CR16","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1002\/mrm.21967","volume":"62","author":"W Lu","year":"2009","unstructured":"Lu W, Pauly KB, Gold GE, Pauly JM, Hargreaves BA (2009) SEMAC: slice encoding for metal artifact correction in MRI. Magn Reson Med 62:66\u201376","journal-title":"Magn Reson Med"},{"key":"6554_CR17","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1148\/radiol.12112408","volume":"265","author":"R Sutter","year":"2012","unstructured":"Sutter R, Ulbrich EJ, Jellus V, Nittka M, Pfirrmann CW (2012) Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging. Radiology 265:204\u2013214","journal-title":"Radiology"},{"key":"6554_CR18","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1055\/s-0037-1606135","volume":"21","author":"I Khodarahmi","year":"2017","unstructured":"Khodarahmi I, Nittka M, Fritz J (2017) Leaps in technology: advanced MR imaging after total hip arthroplasty. Semin Musculoskelet Radiol 21:604\u2013615","journal-title":"Semin Musculoskelet Radiol"},{"key":"6554_CR19","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1002\/jmri.25708","volume":"46","author":"PM Jungmann","year":"2017","unstructured":"Jungmann PM, Agten CA, Pfirrmann CW, Sutter R (2017) Advances in MRI around metal. J Magn Reson Imaging 46:972\u2013991","journal-title":"J Magn Reson Imaging"},{"key":"6554_CR20","doi-asserted-by":"publisher","first-page":"547","DOI":"10.2214\/AJR.11.7364","volume":"197","author":"BA Hargreaves","year":"2011","unstructured":"Hargreaves BA, Worters PW, Pauly KB, Pauly JM, Koch KM, Gold GE (2011) Metal-induced artifacts in MRI. AJR Am J Roentgenol 197:547\u2013555","journal-title":"AJR Am J Roentgenol"},{"key":"6554_CR21","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1002\/mrm.22523","volume":"65","author":"KM Koch","year":"2011","unstructured":"Koch KM, Brau AC, Chen W et al (2011) Imaging near metal with a MAVRIC-SEMAC hybrid. Magn Reson Med 65:71\u201382","journal-title":"Magn Reson Med"},{"key":"6554_CR22","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1097\/RLI.0000000000000317","volume":"51","author":"J Fritz","year":"2016","unstructured":"Fritz J, Ahlawat S, Demehri S et al (2016) Compressed Sensing SEMAC: 8-fold accelerated high resolution metal artifact reduction MRI of cobalt-chromium knee arthroplasty implants. Invest Radiol 51:666\u2013676","journal-title":"Invest Radiol"},{"key":"6554_CR23","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1002\/mrm.26342","volume":"78","author":"R Otazo","year":"2017","unstructured":"Otazo R, Nittka M, Bruno M et al (2017) Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration. Magn Reson Med 78:79\u201387","journal-title":"Magn Reson Med"},{"key":"6554_CR24","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/RLI.0000000000000504","volume":"54","author":"PM Jungmann","year":"2019","unstructured":"Jungmann PM, Bensler S, Zingg P, Fritz B, Pfirrmann CW, Sutter R (2019) Improved visualization of juxtaprosthetic tissue using metal artifact reduction magnetic resonance imaging: experimental and clinical optimization of Compressed Sensing SEMAC. Invest Radiol 54:23\u201331","journal-title":"Invest Radiol"},{"key":"6554_CR25","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1148\/radiol.2016161078","volume":"283","author":"CO Kim","year":"2017","unstructured":"Kim CO, Dietrich TJ, Zingg PO, Dora C, Pfirrmann CWA, Sutter R (2017) Arthroscopic hip surgery: frequency of postoperative MR arthrographic findings in asymptomatic and symptomatic patients. Radiology 283:779\u2013788","journal-title":"Radiology"},{"key":"6554_CR26","first-page":"1833","volume":"15","author":"N Bellamy","year":"1988","unstructured":"Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833\u20131840","journal-title":"J Rheumatol"},{"key":"6554_CR27","doi-asserted-by":"publisher","first-page":"161","DOI":"10.2106\/00004623-199072020-00002","volume":"72","author":"RC Johnston","year":"1990","unstructured":"Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB (1990) Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 72:161\u2013168","journal-title":"J Bone Joint Surg Am"},{"key":"6554_CR28","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC (1979) \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res (141):17\u201327","DOI":"10.1097\/00003086-197906000-00002"},{"key":"6554_CR29","unstructured":"DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res:20\u201332"},{"key":"6554_CR30","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1148\/radiology.215.3.r00jn05835","volume":"215","author":"M Zanetti","year":"2000","unstructured":"Zanetti M, Bruder E, Romero J, Hodler J (2000) Bone marrow edema pattern in osteoarthritic knees: correlation between MR imaging and histologic findings. Radiology 215:835\u2013840","journal-title":"Radiology"},{"key":"6554_CR31","doi-asserted-by":"publisher","first-page":"130","DOI":"10.2214\/AJR.14.13617","volume":"205","author":"R Sutter","year":"2015","unstructured":"Sutter R, Dietrich TJ, Zingg PO, Pfirrmann CW (2015) Assessment of femoral antetorsion with MRI: comparison of oblique measurements to standard transverse measurements. AJR Am J Roentgenol 205:130\u2013135","journal-title":"AJR Am J Roentgenol"},{"key":"6554_CR32","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1148\/radiol.12111903","volume":"263","author":"R Sutter","year":"2012","unstructured":"Sutter R, Dietrich TJ, Zingg PO, Pfirrmann CW (2012) Femoral antetorsion: comparing asymptomatic volunteers and patients with femoroacetabular impingement. Radiology 263:475\u2013483","journal-title":"Radiology"},{"key":"6554_CR33","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174","journal-title":"Biometrics"},{"key":"6554_CR34","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1148\/radiol.2282011860","volume":"228","author":"HL Kundel","year":"2003","unstructured":"Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303\u2013308","journal-title":"Radiology"},{"key":"6554_CR35","doi-asserted-by":"publisher","first-page":"140","DOI":"10.2214\/AJR.13.11785","volume":"204","author":"SJ Choi","year":"2015","unstructured":"Choi SJ, Koch KM, Hargreaves BA, Stevens KJ, Gold GE (2015) Metal artifact reduction with MAVRIC SL at 3-T MRI in patients with hip arthroplasty. AJR Am J Roentgenol 204:140\u2013147","journal-title":"AJR Am J Roentgenol"},{"key":"6554_CR36","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1097\/RLI.0000000000000351","volume":"52","author":"L Filli","year":"2017","unstructured":"Filli L, Jud L, Luechinger R et al (2017) Material-dependent implant artifact reduction using SEMAC-VAT and MAVRIC: a prospective MRI phantom study. Invest Radiol 52:381\u2013387","journal-title":"Invest Radiol"},{"key":"6554_CR37","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1055\/s-0041-104893","volume":"187","author":"X Deligianni","year":"2015","unstructured":"Deligianni X, Bieri O, Elke R, Wischer T, Egelhof T (2015) Optimization of scan time in MRI for total hip prostheses: SEMAC tailoring for prosthetic implants containing different types of metals. Rofo 187:1116\u20131122","journal-title":"Rofo"},{"key":"6554_CR38","doi-asserted-by":"publisher","first-page":"1345","DOI":"10.1007\/s00256-016-2437-0","volume":"45","author":"J Fritz","year":"2016","unstructured":"Fritz J, Fritz B, Thawait GK et al (2016) Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC. Skeletal Radiol 45:1345\u20131356","journal-title":"Skeletal Radiol"},{"key":"6554_CR39","doi-asserted-by":"publisher","first-page":"559","DOI":"10.2214\/AJR.12.8843","volume":"199","author":"H Mulcahy","year":"2012","unstructured":"Mulcahy H, Chew FS (2012) Current concepts of hip arthroplasty for radiologists: part 1, features and radiographic assessment. AJR Am J Roentgenol 199:559\u2013569","journal-title":"AJR Am J Roentgenol"},{"key":"6554_CR40","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1148\/rg.341135130","volume":"34","author":"F Del Grande","year":"2014","unstructured":"Del Grande F, Santini F, Herzka DA et al (2014) Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system. Radiographics 34:217\u2013233","journal-title":"Radiographics"},{"key":"6554_CR41","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1023\/A:1011216509099","volume":"12","author":"M Bosetti","year":"2001","unstructured":"Bosetti M, Masse A, Navone R, Cannas M (2001) Biochemical and histological evaluation of human synovial-like membrane around failed total hip replacement prostheses during in vitro mechanical loading. J Mater Sci Mater Med 12:693\u2013698","journal-title":"J Mater Sci Mater Med"},{"key":"6554_CR42","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1148\/radiol.2293021061","volume":"229","author":"H Sugimoto","year":"2003","unstructured":"Sugimoto H, Hirose I, Miyaoka E et al (2003) Low-field-strength MR imaging of failed hip arthroplasty: association of femoral periprosthetic signal intensity with radiographic, surgical, and pathologic findings. Radiology 229:718\u2013723","journal-title":"Radiology"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06554-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-019-06554-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06554-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,19]],"date-time":"2020-12-19T00:14:35Z","timestamp":1608336875000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-019-06554-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,20]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["6554"],"URL":"https:\/\/doi.org\/10.1007\/s00330-019-06554-5","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,20]]},"assertion":[{"value":"14 June 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Lukas Filli.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all prospectively included asymptomatic subjects in this study. Ethical approval for retrospective inclusion of symptomatic patients was waived by the local ethics committee.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 Prospective\u2022 Cross-sectional study\u2022 Multi-center study","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}