{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T04:03:33Z","timestamp":1789704213031,"version":"4.0.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Objective<\/jats:title>\n<jats:p>To show that for the MRI workup of non-specific low back pain and\/or lumbar radiculopathy, the acquisition of T1-weighted sequences in the sagittal plane could be waived when using an FSE T2-weighted Dixon sequence.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Materials and methods<\/jats:title>\n<jats:p>Three musculoskeletal radiologists retrospectively reviewed fifty lumbar spine MRI examinations performed for non-specific low back pain and\/or lumbar radiculopathy. Two protocols were separately analyzed in the sagittal plane: a standard protocol (T1-weighted, in-phase, and water-only images of an FSE T2-weighted Dixon sequence) and a simplified protocol (fat-only, in-phase, and water-only images of an FSE T2-weighted Dixon sequence). Eight items usually assessed on T1-weighted sequences were analyzed for each of the vertebrae (<jats:italic>n<\/jats:italic>\u2009=\u2009250), vertebral endplates (<jats:italic>n<\/jats:italic>\u2009=\u2009500), vertebral corners (<jats:italic>n<\/jats:italic>\u2009=\u20091000), foramina (<jats:italic>n<\/jats:italic>\u2009=\u2009500), lamina (<jats:italic>n<\/jats:italic>\u2009=\u2009500), and facet joints (<jats:italic>n<\/jats:italic>\u00a0=\u2009500). Interchangeability of these protocols was tested using the individual equivalence index. A decrease in interobserver agreement of \u2265\u20095% when one reader used the simplified protocol compared with when both readers used the standard protocol was considered clinically significant. Interreader and intrareader agreement were assessed using kappa statistics. Rates of findings with each protocol were compared using odd ratios.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The standard and simplified protocols were interchangeable (range of upper bound of the 95%CI of individual equivalence index\u2009=\u20090.25 to 1.38%). Intraprotocol and interprotocol interreader kappa values were similar (0.253\u20130.671 vs. 0.236\u20130.723, respectively). Rates of findings were not statistically significantly different (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.074), or were higher with the simplified protocol (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.036).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>In our target population, a single sagittal T2-weighted Dixon sequence may replace the recommended combination of T1-, T2-, and fat-suppressed T2-weighted sequences.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Key Points<\/jats:title>\n<jats:p><jats:italic>\u2022 In patients with non-specific low back pain or lumbar radiculopathy, spine MRI in the sagittal plane could be limited to a single FSE T2-weighted Dixon sequence, hereby reducing the acquisition time.<\/jats:italic><\/jats:p>\n<jats:p><jats:italic>\u2022 A simplified protocol of spine MRI in the sagittal plane combining FSE T2-weighted Dixon sequence provides the same information as a standard protocol including T1-, T2-, and fat-suppressed T2-weighted sequences for the workup of degenerative lumbar spine lesions.<\/jats:italic><\/jats:p>\n<jats:p><jats:italic>\u2022 For some findings shown on the simplified protocol, such as focal bone marrow replacement lesions or signs of infection, additional sequences including pre- and post-contrast T1-weighted sequences may be required, as is currently the case when using the standard protocol.<\/jats:italic><\/jats:p>\n<\/jats:sec>","DOI":"10.1007\/s00330-019-06626-6","type":"journal-article","created":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T18:02:47Z","timestamp":1580839367000},"page":"2583-2593","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":47,"title":["MRI of non-specific low back pain and\/or lumbar radiculopathy: do we need T1 when using a sagittal T2-weighted Dixon sequence?"],"prefix":"10.1007","volume":"30","author":[{"given":"Fabio","family":"Zanchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rapha\u00ebl","family":"Richard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmoud","family":"Hussami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnaud","family":"Monier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Fran\u00e7ois","family":"Knebel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3251-3666","authenticated-orcid":false,"given":"Patrick","family":"Omoumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,2,4]]},"reference":[{"issue":"9","key":"6626_CR1","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.1016\/j.jacr.2016.06.008","volume":"13","author":"ND Patel","year":"2016","unstructured":"Patel ND, Broderick DF, Burns J et al (2016) ACR appropriateness criteria low back pain. J Am Coll Radiol 13(9):1069\u20131078","journal-title":"J Am Coll Radiol"},{"issue":"10070","key":"6626_CR2","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1016\/S0140-6736(16)30970-9","volume":"389","author":"C Maher","year":"2017","unstructured":"Maher C, Underwood M, Buchbinder R (2017) Non-specific low back pain. Lancet 389(10070):736\u2013747","journal-title":"Lancet"},{"issue":"3","key":"6626_CR3","doi-asserted-by":"publisher","first-page":"181","DOI":"10.7326\/0003-4819-154-3-201102010-00008","volume":"154","author":"R Chou","year":"2011","unstructured":"Chou R, Qaseem A, Owens DK, Shekelle P (2011) Clinical Guidelines Committee of the American College of Physicians. Diagnostic imaging for low back pain: advice for high-value health care from the American College of Physicians. Ann Intern Med 154(3):181\u2013189","journal-title":"Ann Intern Med"},{"issue":"6","key":"6626_CR4","doi-asserted-by":"publisher","first-page":"2028","DOI":"10.1002\/art.34347","volume":"64","author":"D Hoy","year":"2012","unstructured":"Hoy D, Bain C, Williams G, March L et al (2012) A systematic review of the global prevalence of low back pain. Arthritis Rheum 64(6):2028\u20132037","journal-title":"Arthritis Rheum"},{"issue":"8","key":"6626_CR5","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1007\/s003300050547","volume":"8","author":"BC Vande Berg","year":"1998","unstructured":"Vande Berg BC, Malghem J, Lecouvet FE, Maldague B (1998) Magnetic resonance imaging of normal bone marrow. Eur Radiol 8(8):1327\u20131334","journal-title":"Eur Radiol"},{"issue":"6","key":"6626_CR6","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.2214\/AJR.11.7005","volume":"197","author":"LM Shah","year":"2011","unstructured":"Shah LM, Hanrahan CJ (2011) MRI of spinal bone marrow: part I, techniques and normal age-related appearances. AJR Am J Roentgenol 197(6):1298\u20131308","journal-title":"AJR Am J Roentgenol"},{"key":"6626_CR7","unstructured":"ACR\u2013ASNR\u2013SCBT-MR\u2013SSR Practice parameter for the performance of magnetic resonance imaging (MRI) of the adult spine. American College of Radiology, Reston Virginia. Available via https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Practice-Parameters\/MR-Adult-Spine.pdf?la=en. Accessed 02 Oct 2019"},{"issue":"11","key":"6626_CR8","doi-asserted-by":"publisher","first-page":"e617","DOI":"10.1016\/j.crad.2013.06.004","volume":"68","author":"S Brand\u00e3o","year":"2013","unstructured":"Brand\u00e3o S, Seixas D, Ayres-Basto M et al (2013 Nov) Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine. Clin Radiol 68(11):e617\u2013e623","journal-title":"Clin Radiol"},{"issue":"6","key":"6626_CR9","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1097\/RCT.0000000000000453","volume":"40","author":"SI Zhadanov","year":"2016","unstructured":"Zhadanov SI, Doshi AH, Pawha PS, Corcuera-Solano I, Tanenbaum LN (2016) Contrast-enhanced Dixon fat-water separation imaging of the spine: added value of fat, in-phase and opposed-phase imaging in marrow lesion detection. J Comput Assist Tomogr 40(6):985\u2013990","journal-title":"J Comput Assist Tomogr"},{"issue":"4","key":"6626_CR10","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1055\/s-0035-1565913","volume":"19","author":"H Guerini","year":"2015","unstructured":"Guerini H, Omoumi P, Guichoux F et al (2015) Fat suppression with Dixon techniques in musculoskeletal magnetic resonance imaging: a pictorial review. Semin Musculoskelet Radiol 19(4):335\u2013347","journal-title":"Semin Musculoskelet Radiol"},{"issue":"3","key":"6626_CR11","doi-asserted-by":"publisher","first-page":"603","DOI":"10.2214\/AJR.16.16774","volume":"208","author":"A \u00d6zgen","year":"2016","unstructured":"\u00d6zgen A (2016) The value of the T2-weighted multipoint Dixon sequence in MRI of sacroiliac joints for the diagnosis of active and chronic sacroiliitis. Am J Roentgenol 208(3):603\u2013608","journal-title":"Am J Roentgenol"},{"key":"6626_CR12","doi-asserted-by":"crossref","unstructured":"Park HJ, Lee SY, Rho MH et al (2016) Usefulness of the fast spin-echo three-point Dixon (mDixon) image of the knee joint on 3.0-T MRI: comparison with conventional fast spin-echo T2 weighted image. Br J Radiol 89(1062)","DOI":"10.1259\/bjr.20151074"},{"key":"6626_CR13","first-page":"170325","volume":"2","author":"Y Maeder","year":"2017","unstructured":"Maeder Y, Dunet V, Richard R, Becce F, Omoumi P (2017) Bone marrow metastases: T2-weighted Dixon spin-echo fat images can replace T1-weighted spin-Echo images. Radiology. 2:170325","journal-title":"Radiology."},{"issue":"4","key":"6626_CR14","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1097\/RCT.0000000000000723","volume":"42","author":"S Schlaeger","year":"2018","unstructured":"Schlaeger S, Klupp E, Weidlich D et al (2018) T2-weighted Dixon turbo spin echo for accelerated simultaneous grading of whole-body skeletal muscle fat infiltration and edema in patients with neuromuscular diseases. J Comput Assist Tomogr 42(4):574\u2013579","journal-title":"J Comput Assist Tomogr"},{"issue":"1088","key":"6626_CR15","doi-asserted-by":"publisher","first-page":"20170779","DOI":"10.1259\/bjr.20170779","volume":"91","author":"JH You","year":"2018","unstructured":"You JH, Kim IH, Hwang J, Lee HS, Park EH (2018) Fracture of ankle: MRI using opposed-phase imaging obtained from turbo spin echo modified Dixon image shows improved sensitivity. Br J Radiol 91(1088):20170779","journal-title":"Br J Radiol"},{"issue":"1","key":"6626_CR16","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1148\/rg.341135130","volume":"34","author":"F Del Grande","year":"2014","unstructured":"Del Grande F, Santini F, Herzka DA et al (2014) Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system. Radiographics 34(1):217\u2013233","journal-title":"Radiographics"},{"key":"6626_CR17","doi-asserted-by":"crossref","unstructured":"Delfaut EM, Beltran J, Johnson G, Rousseau J, Marchandise X, Cotten A (1999) Fat suppression in MR imaging: techniques and pitfalls. Radiographics 19(2):373\u2013382","DOI":"10.1148\/radiographics.19.2.g99mr03373"},{"issue":"6","key":"6626_CR18","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1002\/jmri.20201","volume":"20","author":"J Ma","year":"2004","unstructured":"Ma J, Singh SK, Kumar AJ, Leeds NE, Zhan J (2004) T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 20(6):1025\u20131029","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"6626_CR19","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1148\/radiology.153.1.6089263","volume":"153","author":"WT Dixon","year":"1984","unstructured":"Dixon WT (1984) Simple proton spectroscopic imaging. Radiology. 153(1):189\u2013194","journal-title":"Radiology."},{"issue":"2","key":"6626_CR20","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1002\/mrm.1910180211","volume":"18","author":"GH Glover","year":"1991","unstructured":"Glover GH, Schneider E (1991) Three-point Dixon technique for true water\/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 18(2):371\u2013383","journal-title":"Magn Reson Med"},{"issue":"3","key":"6626_CR21","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1002\/jmri.21492","volume":"28","author":"J Ma","year":"2008","unstructured":"Ma J (2008) Dixon techniques for water and fat imaging. J Magn Reson Imaging 28(3):543\u2013558","journal-title":"J Magn Reson Imaging"},{"issue":"1085","key":"6626_CR22","doi-asserted-by":"publisher","first-page":"20170782","DOI":"10.1259\/bjr.20170782","volume":"91","author":"S Hahn","year":"2018","unstructured":"Hahn S, Lee YH, Suh J-S (2018) Detection of vertebral metastases: a comparison between the modified Dixon turbo spin echo T2 weighted MRI and conventional T1 weighted MRI: a preliminary study in a tertiary centre. Br J Radiol 91(1085):20170782. https:\/\/doi.org\/10.1259\/bjr.20170782","journal-title":"Br J Radiol"},{"issue":"10","key":"6626_CR23","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1007\/s002560050434","volume":"27","author":"BC Vande Berg","year":"1998","unstructured":"Vande Berg BC, Malghem J, Lecouvet FE, Maldague B (1998) Classification and detection of bone marrow lesions with magnetic resonance imaging. Skeletal Radiol 27(10):529\u2013545","journal-title":"Skeletal Radiol"},{"issue":"1 Pt 1","key":"6626_CR24","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1148\/radiology.166.1.3336678","volume":"166","author":"MT Modic","year":"1988","unstructured":"Modic MT, Steinberg PM, Ross JS, Masaryk TJ, Carter JR (1988) Degenerative disk disease: assessment of changes in vertebral body marrow with MR imaging. Radiology. 166(1 Pt 1):193\u2013199","journal-title":"Radiology."},{"issue":"4","key":"6626_CR25","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.2214\/AJR.09.2772","volume":"194","author":"S Lee","year":"2010","unstructured":"Lee S, Lee JW, Yeom JS et al (2010) A practical MRI grading system for lumbar foraminal stenosis. AJR Am J Roentgenol 194(4):1095\u20131098","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"6626_CR26","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00256-017-2780-9","volume":"47","author":"EF Alaia","year":"2018","unstructured":"Alaia EF, Benedick A, Obuchowski NA et al (2018) Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study. Skeletal Radiol 47(1):107\u2013116","journal-title":"Skeletal Radiol"},{"issue":"11","key":"6626_CR27","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1016\/j.acra.2014.07.004","volume":"21","author":"NA Obuchowski","year":"2014","unstructured":"Obuchowski NA, Subhas N, Schoenhagen P (2014) Testing for interchangeability of imaging tests. Acad Radiol 21(11):1483\u20131489","journal-title":"Acad Radiol"},{"issue":"4","key":"6626_CR28","doi-asserted-by":"publisher","first-page":"W146","DOI":"10.2214\/AJR.16.17041","volume":"208","author":"N Subhas","year":"2017","unstructured":"Subhas N, Benedick A, Obuchowski NA et al (2017) Comparison of a fast 5-minute shoulder MRI protocol with a standard shoulder MRI protocol: a multiinstitutional multireader study. AJR Am J Roentgenol 208(4):W146\u2013W154","journal-title":"AJR Am J Roentgenol"},{"key":"6626_CR29","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511802843","volume-title":"Bootstrap methods and their application","author":"AC Davison","year":"1997","unstructured":"Davison AC, Hinkley DV (1997) Bootstrap methods and their application. Cambridge University Press, Cambridge"},{"issue":"1","key":"6626_CR30","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics. 33(1):159\u2013174","journal-title":"Biometrics."},{"issue":"13","key":"6626_CR31","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1002\/(SICI)1097-0258(19980715)17:13<1495::AID-SIM863>3.0.CO;2-I","volume":"17","author":"NA Obuchowski","year":"1998","unstructured":"Obuchowski NA (1998) On the comparison of correlated proportions for clustered data. Stat Med 17(13):1495\u20131507","journal-title":"Stat Med"},{"issue":"1","key":"6626_CR32","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1148\/radiol.2493071999","volume":"250","author":"JA Carrino","year":"2009","unstructured":"Carrino JA, Lurie JD, Tosteson ANA et al (2009) Lumbar spine: reliability of MR imaging findings. Radiology. 250(1):161\u2013170","journal-title":"Radiology."},{"issue":"9","key":"6626_CR33","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.diii.2019.05.001","volume":"100","author":"A Danner","year":"2019","unstructured":"Danner A, Brumpt E, Alilet M, Tio G, Omoumi P, Aubry S (2019) Improved contrast for myeloma focal lesions with T2-weighted Dixon images compared to T1-weighted images. Diagn Interv Imaging 100(9):513\u2013519","journal-title":"Diagn Interv Imaging"},{"key":"6626_CR34","unstructured":"Czervionke LF, Fenton DS (2008) Fat-saturated MR imaging in the detection of inflammatory facet arthropathy (facet synovitis) in the lumbar spine. Pain Med 9(4):400\u2013406"},{"issue":"7\u20138 Pt 1","key":"6626_CR35","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1016\/S0221-0363(07)89900-8","volume":"88","author":"G Morvan","year":"2007","unstructured":"Morvan G, Vuillemin-Bodaghi V, Wybier M, Mathieu P, Busson J, Haddad A (2007) The \u201cde S\u00e8ze\u201d magnetic imaging. J Radiol 88(7\u20138 Pt 1):943\u2013946","journal-title":"J Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06626-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00330-019-06626-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-019-06626-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,3]],"date-time":"2021-02-03T00:09:55Z","timestamp":1612310995000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00330-019-06626-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,4]]},"references-count":35,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["6626"],"URL":"https:\/\/doi.org\/10.1007\/s00330-019-06626-6","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,4]]},"assertion":[{"value":"26 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 November 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Patrick Omoumi, Lausanne University Hospital.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Dr. Jean-Fran\u00e7ois Knebel (one of the authors) kindly provided statistical advice for this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained (Project ID 2017-01555 by Swiss Ethics Committees on research involving humans).","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 retrospective\u2022 not applicable\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}