{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T19:35:28Z","timestamp":1793388928216,"version":"4.5.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T00:00:00Z","timestamp":1587686400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T00:00:00Z","timestamp":1587686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s00330-020-06890-x","type":"journal-article","created":{"date-parts":[[2020,4,24]],"date-time":"2020-04-24T11:03:36Z","timestamp":1587726216000},"page":"5130-5138","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Respiratory motion\u2013resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE"],"prefix":"10.1007","volume":"30","author":[{"given":"Kyungsoo","family":"Bae","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyung Nyeo","family":"Jeon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moon Jung","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joon Sung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung Eun","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ho Cheol","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Menini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,4,24]]},"reference":[{"key":"6890_CR1","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jmr.2013.01.011","volume":"229","author":"M Garwood","year":"2013","unstructured":"Garwood M (2013) MRI of fast-relaxing spins. J Magn Reson 229:49\u201354","journal-title":"J Magn Reson"},{"key":"6890_CR2","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1002\/mrm.21230","volume":"57","author":"DO Kuethe","year":"2007","unstructured":"Kuethe DO, Adolphi NL, Fukushima E (2007) Short data-acquisition times improve projection images of lung tissue. Magn Reson Med 57:1058\u20131064","journal-title":"Magn Reson Med"},{"key":"6890_CR3","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1002\/jmri.25008","volume":"43","author":"Y Ohno","year":"2016","unstructured":"Ohno Y, Koyama H, Yoshikawa T et al (2016) Pulmonary high-resolution ultrashort TE MR imaging: comparison with thin-section standard- and low-dose computed tomography for the assessment of pulmonary parenchyma diseases. J Magn Reson Imaging 43:512\u2013532","journal-title":"J Magn Reson Imaging"},{"key":"6890_CR4","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1002\/mrm.27800","volume":"82","author":"MM Willmering","year":"2019","unstructured":"Willmering MM, Robison RK, Wang H, Pipe JG, Woods JC (2019) Implementation of the FLORET UTE sequence for lung imaging. Magn Reson Med 82:1091\u20131100","journal-title":"Magn Reson Med"},{"key":"6890_CR5","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.acra.2018.12.007","volume":"26","author":"L Torres","year":"2019","unstructured":"Torres L, Kammerman J, Hahn AD et al (2019) Structure-function imaging of lung disease using ultrashort echo time MRI. Acad Radiol 26:431\u2013441","journal-title":"Acad Radiol"},{"key":"6890_CR6","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1148\/radiology.179.3.2027991","volume":"179","author":"CJ Bergin","year":"1991","unstructured":"Bergin CJ, Pauly JM, Macovski A (1991) Lung parenchyma: projection reconstruction MR imaging. Radiology 179:777\u2013781","journal-title":"Radiology"},{"key":"6890_CR7","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1002\/mrm.22521","volume":"64","author":"O Togao","year":"2010","unstructured":"Togao O, Tsuji R, Ohno Y, Dimitrov I, Takahashi M (2010) Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma. Magn Reson Med 64:1491\u20131498","journal-title":"Magn Reson Med"},{"key":"6890_CR8","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1002\/jmri.24680","volume":"41","author":"W Ma","year":"2015","unstructured":"Ma W, Sheikh K, Svenningsen S et al (2015) Ultra-short echo-time pulmonary MRI: evaluation and reproducibility in COPD subjects with and without bronchiectasis. J Magn Reson Imaging 41:1465\u20131474","journal-title":"J Magn Reson Imaging"},{"key":"6890_CR9","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1002\/jmri.25073","volume":"43","author":"ND Gai","year":"2016","unstructured":"Gai ND, Malayeri A, Agarwal H, Evers R, Bluemke D (2016) Evaluation of optimized breath-hold and free-breathing 3D ultrashort echo time contrast agent-free MRI of the human lung. J Magn Reson Imaging 43:1230\u20131238","journal-title":"J Magn Reson Imaging"},{"key":"6890_CR10","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1002\/mrm.24816","volume":"70","author":"M Weiger","year":"2013","unstructured":"Weiger M, Brunner DO, Dietrich BE, Muller CF, Pruessmann KP (2013) ZTE imaging in humans. Magn Reson Med 70:328\u2013332","journal-title":"Magn Reson Med"},{"key":"6890_CR11","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s10334-014-0459-y","volume":"28","author":"F Gibiino","year":"2015","unstructured":"Gibiino F, Sacolick L, Menini A, Landini L, Wiesinger F (2015) Free-breathing, zero-TE MR lung imaging. MAGMA 28:207\u2013215","journal-title":"MAGMA"},{"key":"6890_CR12","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1007\/s00330-018-5889-x","volume":"29","author":"K Bae","year":"2019","unstructured":"Bae K, Jeon KN, Hwang MJ et al (2019) Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study. Eur Radiol 29:2253\u20132262","journal-title":"Eur Radiol"},{"key":"6890_CR13","doi-asserted-by":"crossref","first-page":"3811","DOI":"10.1007\/s00330-016-4218-5","volume":"26","author":"G Dournes","year":"2016","unstructured":"Dournes G, Menut F, Macey J et al (2016) Lung morphology assessment of cystic fibrosis using MRI with ultra-short echo time at submillimeter spatial resolution. Eur Radiol 26:3811\u20133820","journal-title":"Eur Radiol"},{"key":"6890_CR14","doi-asserted-by":"crossref","first-page":"1885","DOI":"10.1002\/mrm.25321","volume":"73","author":"C Forman","year":"2015","unstructured":"Forman C, Piccini D, Grimm R, Hutter J, Hornegger J, Zenge MO (2015) Reduction of respiratory motion artifacts for free-breathing whole-heart coronary MRA by weighted iterative reconstruction. Magn Reson Med 73:1885\u20131895","journal-title":"Magn Reson Med"},{"key":"6890_CR15","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1002\/jmri.26245","volume":"49","author":"L Feng","year":"2019","unstructured":"Feng L, Delacoste J, Smith D et al (2019) Simultaneous evaluation of lung anatomy and ventilation using 4D respiratory-motion-resolved ultrashort echo time sparse MRI. J Magn Reson Imaging 49:411\u2013422","journal-title":"J Magn Reson Imaging"},{"key":"6890_CR16","unstructured":"Menini A, Lai P, McKinnon G, Wiesinger F (2018) Self-calibrated soft gating for respiratory resolved 3D+ time lung ZTE. Proceedings of the joint annual meeting ISMRM-ESMRMB, Paris, France. Available via http:\/\/archive.ismrm.org\/2018\/4104.html. Accessed 19 Nov 2019"},{"key":"6890_CR17","doi-asserted-by":"crossref","first-page":"1879","DOI":"10.1007\/s00330-015-3954-2","volume":"26","author":"M Costagli","year":"2016","unstructured":"Costagli M, Symms MR, Angeli L et al (2016) Assessment of silent T1-weighted head imaging at 7 T. Eur Radiol 26:1879\u20131888","journal-title":"Eur Radiol"},{"key":"6890_CR18","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1002\/jmri.24850","volume":"42","author":"M Zaitsev","year":"2015","unstructured":"Zaitsev M, Maclaren J, Herbst M (2015) Motion artifacts in MRI: a complex problem with many partial solutions. J Magn Reson Imaging 42:887\u2013901","journal-title":"J Magn Reson Imaging"},{"key":"6890_CR19","doi-asserted-by":"crossref","first-page":"5037","DOI":"10.1118\/1.3480508","volume":"37","author":"C Liu","year":"2010","unstructured":"Liu C, Alessio A, Pierce L et al (2010) Quiescent period respiratory gating for PET\/CT. Med Phys 37:5037\u20135043","journal-title":"Med Phys"},{"key":"6890_CR20","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1148\/radiol.2502071998","volume":"250","author":"AD Scott","year":"2009","unstructured":"Scott AD, Keegan J, Firmin DN (2009) Motion in cardiovascular MR imaging. Radiology 250:331\u2013351","journal-title":"Radiology"},{"key":"6890_CR21","doi-asserted-by":"crossref","unstructured":"Ehman RL, McNamara MT, Pallack M, Hricak H, Higgins CB (1984) Magnetic resonance imaging with respiratory gating: techniques and advantages. AJR Am J Roentgenol 143:1175\u20131182","DOI":"10.2214\/ajr.143.6.1175"},{"key":"6890_CR22","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1148\/radiol.2203010132","volume":"220","author":"K Nehrke","year":"2001","unstructured":"Nehrke K, Bornert P, Manke D, Bock JC (2001) Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results. Radiology 220:810\u2013815","journal-title":"Radiology"},{"key":"6890_CR23","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1002\/mrm.23144","volume":"67","author":"KM Johnson","year":"2012","unstructured":"Johnson KM, Block WF, Reeder SB, Samsonov A (2012) Improved least squares MR image reconstruction using estimates of k-space data consistency. Magn Reson Med 67:1600\u20131608","journal-title":"Magn Reson Med"},{"key":"6890_CR24","doi-asserted-by":"crossref","first-page":"2954","DOI":"10.1002\/mrm.26958","volume":"79","author":"W Jiang","year":"2018","unstructured":"Jiang W, Ong F, Johnson KM et al (2018) Motion robust high resolution 3D free-breathing pulmonary MRI using dynamic 3D image self-navigator. Magn Reson Med 79:2954\u20132967","journal-title":"Magn Reson Med"},{"key":"6890_CR25","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1002\/mrm.26206","volume":"77","author":"CM Rank","year":"2017","unstructured":"Rank CM, Heu\u00dfer T, Buzan MT et al (2017) 4D respiratory motion-compensated image reconstruction of free-breathing radial MR data with very high undersampling. Magn Reson Med 77:1170\u20131183","journal-title":"Magn Reson Med"},{"key":"6890_CR26","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1148\/radiol.2017161037","volume":"284","author":"Y Ohno","year":"2017","unstructured":"Ohno Y, Koyama H, Yoshikawa T et al (2017) Standard-, reduced-, and no-dose thin-section radiologic examinations: comparison of capability for nodule detection and nodule type assessment in patients suspected of having pulmonary nodules. Radiology 284:562\u2013573","journal-title":"Radiology"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-06890-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-020-06890-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-06890-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,30]],"date-time":"2023-09-30T04:49:02Z","timestamp":1696049342000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-020-06890-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,24]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["6890"],"URL":"https:\/\/doi.org\/10.1007\/s00330-020-06890-x","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,24]]},"assertion":[{"value":"2 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Kyung Nyeo Jeon.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the company GE Healthcare. MJ Hwang, JS Lee, and Anne Menini are employees of GE Healthcare.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all patients in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"This study was approved by the Institutional Review Board of Gyeongsang National University Changwon Hospital.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 observational\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}