{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T11:41:18Z","timestamp":1781005278317,"version":"3.54.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,6,18]],"date-time":"2020-06-18T00:00:00Z","timestamp":1592438400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,18]],"date-time":"2020-06-18T00:00:00Z","timestamp":1592438400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Innsbruck and Medical University of Innsbruck"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2020,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Objectives<\/jats:title>\n<jats:p>To evaluate magnetic resonance cholangiopancreatography (MRCP) with compressed sensing (CS) for the assessment of branch duct intraductal papillary mucinous neoplasm (BD-IPMN) of the pancreas. For this purpose, conventional navigator-triggered (NT) sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) MRCP was compared with various CS-SPACE-MRCP sequences in a clinical setting.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>A total of 41 patients (14 male, 27 female, mean age 68 years) underwent 1.5-T MRCP for the evaluation of BD-IPMN. The MRCP protocol consisted of the following sequences: conventional NT-SPACE-MRCP, CS-SPACE-MRCP with long (BHL, 17 s) and short single breath-hold (BHS, 8 s), and NT-CS-SPACE-MRCP. Two board-certified radiologists evaluated image quality, duct sharpness, duct visualization, lesion conspicuity, confidence, and communication with the main pancreatic duct in consensus using a 5-point scale (1\u20135), with higher scores indicating better quality\/delineation\/confidence. Maximum intensity projection reconstructions and originally acquired data were used for evaluation. Wilcoxon signed-rank test was used to compare the intra-individual difference between sequences.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>BHS-CS-SPACE-MRCP had the highest scores for image quality (3.85 \u00b1 0.79), duct sharpness (3.81 \u00b1 1.05), and duct visualization (3.81 \u00b1 1.01). There was a significant difference compared with NT-CS-SPACE-MRCP (<jats:italic>p<\/jats:italic> &lt; 0.05) but no significant difference to the standard NT-SPACE-MRCP (<jats:italic>p<\/jats:italic> &gt; 0.05). Concerning diagnostic quality, BHS-CS-SPACE-MRCP had the highest scores in lesion conspicuity (3.95 \u00b1 0.92), confidence (4.12 \u00b1 1.08), and communication (3.8 \u00b1 1.06), significantly higher compared with NT-SPACE-MRCP, BHL-SPACE-MRCP, and NT-CS-SPACE-MRCP (<jats:italic>p<\/jats:italic> = &lt;0.05).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>MRCP with CS 3D SPACE for the evaluation of BD-IPMN at 1.5 T provides the best results using a short breath-hold sequence. This approach is feasible and an excellent alternative to standard NT 3D MRCP sequences.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Key Points<\/jats:title>\n<jats:p><jats:italic>\u2022 1.5-T MRCP with compressed sensing for the evaluation of branch duct IPMN is a feasible method.<\/jats:italic><\/jats:p>\n<jats:p><jats:italic>\u2022 Short breath-hold sequences provide the best results for this purpose.<\/jats:italic><\/jats:p>\n<\/jats:sec>","DOI":"10.1007\/s00330-020-06996-2","type":"journal-article","created":{"date-parts":[[2020,6,18]],"date-time":"2020-06-18T00:02:26Z","timestamp":1592438546000},"page":"6014-6021","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas"],"prefix":"10.1007","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2872-840X","authenticated-orcid":false,"given":"Benjamin","family":"Henninger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Steurer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michaela","family":"Plaikner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisabeth","family":"Weiland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Werner","family":"Jaschke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Kremser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,18]]},"reference":[{"key":"6996_CR1","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.rcl.2014.02.006","volume":"52","author":"E O\u2019Neill","year":"2014","unstructured":"O\u2019Neill E, Hammond N, Miller FH (2014) MR imaging of the pancreas. Radiol Clin North Am 52:757\u2013777","journal-title":"Radiol Clin North Am"},{"key":"6996_CR2","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1016\/j.pan.2017.07.007","volume":"17","author":"M Tanaka","year":"2017","unstructured":"Tanaka M, Fernandez-Del Castillo C, Kamisawa T et al (2017) Revisions of international consensus Fukuoka guidelines for the management of IPMN of the pancreas. Pancreatology 17:738\u2013753","journal-title":"Pancreatology"},{"key":"6996_CR3","doi-asserted-by":"crossref","unstructured":"Anupindi SA, Victoria T (2008) Magnetic resonance cholangiopancreatography: techniques and applications. Magn Reson Imaging Clin N Am 16:453\u2013466 v","DOI":"10.1016\/j.mric.2008.04.005"},{"key":"6996_CR4","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1148\/radiol.14132960","volume":"274","author":"SH Kim","year":"2015","unstructured":"Kim SH, Lee JM, Lee ES et al (2015) Intraductal papillary mucinous neoplasms of the pancreas: evaluation of malignant potential and surgical resectability by using MR imaging with MR cholangiography. Radiology 274:723\u2013733","journal-title":"Radiology"},{"key":"6996_CR5","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1148\/radiol.2382032065","volume":"238","author":"A Sodickson","year":"2006","unstructured":"Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM (2006) Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 238:549\u2013559","journal-title":"Radiology"},{"key":"6996_CR6","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.3892\/ol.2015.2935","volume":"9","author":"K Liu","year":"2015","unstructured":"Liu K, Xie P, Peng W, Zhou Z (2015) Magnetic resonance cholangiopancreatography: comparison of two- and three-dimensional sequences for the assessment of pancreatic cystic lesions. Oncol Lett 9:1917\u20131921","journal-title":"Oncol Lett"},{"key":"6996_CR7","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.jacr.2017.03.010","volume":"14","author":"AJ Megibow","year":"2017","unstructured":"Megibow AJ, Baker ME, Morgan DE et al (2017) Management of incidental pancreatic cysts: a white paper of the ACR Incidental Findings Committee. J Am Coll Radiol 14:911\u2013923","journal-title":"J Am Coll Radiol"},{"key":"6996_CR8","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1002\/jmri.21484","volume":"28","author":"S Arizono","year":"2008","unstructured":"Arizono S, Isoda H, Maetani YS et al (2008) High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3 T: comparison with the conventional constant flip angle sequence in healthy volunteers. J Magn Reson Imaging 28:685\u2013690","journal-title":"J Magn Reson Imaging"},{"key":"6996_CR9","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182\u20131195","journal-title":"Magn Reson Med"},{"key":"6996_CR10","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.ejrad.2018.03.001","volume":"102","author":"B Henninger","year":"2018","unstructured":"Henninger B, Raithel E, Kranewitter C, Steurer M, Jaschke W, Kremser C (2018) Evaluation of an accelerated 3D SPACE sequence with compressed sensing and free-stop scan mode for imaging of the knee. Eur J Radiol 102:74\u201382","journal-title":"Eur J Radiol"},{"key":"6996_CR11","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1016\/j.jcmg.2014.04.016","volume":"7","author":"G Vincenti","year":"2014","unstructured":"Vincenti G, Monney P, Chaptinel J et al (2014) Compressed sensing single-breath-hold CMR for fast quantification of LV function, volumes, and mass. JACC Cardiovasc Imaging 7:882\u2013892","journal-title":"JACC Cardiovasc Imaging"},{"key":"6996_CR12","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1148\/radiol.2016151935","volume":"280","author":"H Chandarana","year":"2016","unstructured":"Chandarana H, Doshi AM, Shanbhogue A et al (2016) Three-dimensional MR cholangiopancreatography in a breath hold with sparsity-based reconstruction of highly undersampled data. Radiology 280:585\u2013594","journal-title":"Radiology"},{"key":"6996_CR13","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1002\/jmri.25672","volume":"46","author":"N Seo","year":"2017","unstructured":"Seo N, Park MS, Han K et al (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3 T. J Magn Reson Imaging 46:1289\u20131297","journal-title":"J Magn Reson Imaging"},{"key":"6996_CR14","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1007\/s00261-018-01886-0","volume":"44","author":"S Nagata","year":"2019","unstructured":"Nagata S, Goshima S, Noda Y et al (2019) Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique. Abdom Radiol (NY) 44:1766\u20131772","journal-title":"Abdom Radiol (NY)"},{"key":"6996_CR15","unstructured":"(2006) R Development Core Team (2006), Vienna, Austria, URL: http:\/\/www.R-project.org, Version 3.5.1."},{"key":"6996_CR16","unstructured":"Matthias Gamer JL, and Ian Fellows Puspendra Singh (2012). irr: Various coefficients of interrater reliability and agreement. R package version 084 https:\/\/www.CRANR-projectorg\/package=irr"},{"key":"6996_CR17","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1097\/RCT.0b013e3181852193","volume":"33","author":"LS Yoon","year":"2009","unstructured":"Yoon LS, Catalano OA, Fritz S, Ferrone CR, Hahn PF, Sahani DV (2009) Another dimension in magnetic resonance cholangiopancreatography: comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas. J Comput Assist Tomogr 33:363\u2013368","journal-title":"J Comput Assist Tomogr"},{"key":"6996_CR18","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.1007\/s00261-017-1451-6","volume":"43","author":"H Kwon","year":"2018","unstructured":"Kwon H, Reid S, Kim D, Lee S, Cho J, Oh J (2018) Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing. Abdom Radiol (NY) 43:2255\u20132261","journal-title":"Abdom Radiol (NY)"},{"key":"6996_CR19","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.mri.2018.05.015","volume":"52","author":"A Furlan","year":"2018","unstructured":"Furlan A, Bayram E, Thangasamy S, Barley D, Dasyam A (2018) Application of compressed sensing to 3D magnetic resonance cholangiopancreatography for the evaluation of pancreatic cystic lesions. Magn Reson Imaging 52:131\u2013136","journal-title":"Magn Reson Imaging"},{"key":"6996_CR20","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1097\/RLI.0000000000000489","volume":"53","author":"J Taron","year":"2018","unstructured":"Taron J, Weiss J, Notohamiprodjo M et al (2018) Acceleration of magnetic resonance cholangiopancreatography using compressed sensing at 1.5 and 3 T: a clinical feasibility study. Invest Radiol 53:681\u2013688","journal-title":"Invest Radiol"},{"key":"6996_CR21","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/RLI.0000000000000421","volume":"53","author":"L Zhu","year":"2018","unstructured":"Zhu L, Wu X, Sun Z et al (2018) Compressed-sensing accelerated 3-dimensional magnetic resonance cholangiopancreatography: application in suspected pancreatic diseases. Invest Radiol 53:150\u2013157","journal-title":"Invest Radiol"},{"key":"6996_CR22","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1097\/RLI.0000000000000380","volume":"52","author":"JH Yoon","year":"2017","unstructured":"Yoon JH, Lee SM, Kang HJ et al (2017) Clinical feasibility of 3-dimensional magnetic resonance cholangiopancreatography using compressed sensing: comparison of image quality and diagnostic performance. Invest Radiol 52:612\u2013619","journal-title":"Invest Radiol"},{"key":"6996_CR23","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.1002\/jmri.26049","volume":"48","author":"L Zhu","year":"2018","unstructured":"Zhu L, Xue H, Sun Z et al (2018) Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 48:1389\u20131399","journal-title":"J Magn Reson Imaging"},{"key":"6996_CR24","doi-asserted-by":"publisher","first-page":"108765","DOI":"10.1016\/j.ejrad.2019.108765","volume":"122","author":"H Tokoro","year":"2020","unstructured":"Tokoro H, Yamada A, Suzuki T et al (2020) Usefulness of breath-hold compressed sensing accelerated three-dimensional magnetic resonance cholangiopancreatography (MRCP) added to respiratory-gating conventional MRCP. Eur J Radiol 122:108765","journal-title":"Eur J Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-06996-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-020-06996-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-06996-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T23:23:03Z","timestamp":1623972183000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-020-06996-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,18]]},"references-count":24,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["6996"],"URL":"https:\/\/doi.org\/10.1007\/s00330-020-06996-2","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,18]]},"assertion":[{"value":"31 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is PD Dr. Benjamin Henniner.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: Siemens Healthineers.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was not required for this study because of its retrospective character and further written informed consent was waived by the institutional review board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional review board approval was not required because of the retrospective character.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022retrospective\u2022observational\u2022performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}