{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T15:08:04Z","timestamp":1761664084731,"version":"3.37.3"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T00:00:00Z","timestamp":1592006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T00:00:00Z","timestamp":1592006400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1007\/s00330-020-07010-5","type":"journal-article","created":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T21:02:37Z","timestamp":1592082157000},"page":"5826-5833","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of liver iron overload with R2* relaxometry with versus without fat suppression: both are clinically accurate but there are differences"],"prefix":"10.1007","volume":"30","author":[{"given":"M.","family":"Plaikner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6953-935X","authenticated-orcid":false,"given":"C.","family":"Kremser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Zoller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Jaschke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Steurer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Viveiros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Henninger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,6,13]]},"reference":[{"key":"7010_CR1","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1056\/NEJM200008033430503","volume":"343","author":"E Angelucci","year":"2000","unstructured":"Angelucci E, Brittenham GM, McLaren CE et al (2000) Hepatic iron concentration and total body iron stores in thalassemia major. N Engl J Med 343:327\u2013331","journal-title":"N Engl J Med"},{"key":"7010_CR2","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1002\/jmri.24584","volume":"40","author":"D Hernando","year":"2014","unstructured":"Hernando D, Levin YS, Sirlin CB, Reeder SB (2014) Quantification of liver iron with MRI: state of the art and remaining challenges. J Magn Reson Imaging 40:1003\u20131021","journal-title":"J Magn Reson Imaging"},{"key":"7010_CR3","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.3748\/wjg.v16.i13.1587","volume":"16","author":"K Tziomalos","year":"2010","unstructured":"Tziomalos K, Perifanis V (2010) Liver iron content determination by magnetic resonance imaging. World J Gastroenterol 16:1587\u20131597","journal-title":"World J Gastroenterol"},{"issue":"359\u2013381","key":"7010_CR4","first-page":"ix","volume":"18","author":"CB Sirlin","year":"2010","unstructured":"Sirlin CB, Reeder SB (2010) Magnetic resonance imaging quantification of liver iron. Magn Reson Imaging Clin N Am 18(359\u2013381):ix","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"7010_CR5","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s11547-016-0661-2","volume":"121","author":"L Bacigalupo","year":"2016","unstructured":"Bacigalupo L, Paparo F, Zefiro D et al (2016) Comparison between different software programs and post-processing techniques for the MRI quantification of liver iron concentration in thalassemia patients. Radiol Med 121:751\u2013762","journal-title":"Radiol Med"},{"key":"7010_CR6","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1111\/bjh.13374","volume":"170","author":"JC Wood","year":"2015","unstructured":"Wood JC (2015) Estimating tissue iron burden: current status and future prospects. Br J Haematol 170:15\u201328","journal-title":"Br J Haematol"},{"key":"7010_CR7","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s13244-011-0132-1","volume":"3","author":"JM Alustiza Echeverria","year":"2012","unstructured":"Alustiza Echeverria JM, Castiella A, Emparanza JI (2012) Quantification of iron concentration in the liver by MRI. Insights Imaging 3:173\u2013180","journal-title":"Insights Imaging"},{"key":"7010_CR8","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/S0730-725X(03)00080-8","volume":"21","author":"PR Clark","year":"2003","unstructured":"Clark PR, Chua-anusorn W, St Pierre TG (2003) Bi-exponential proton transverse relaxation rate (R2) image analysis using RF field intensity-weighted spin density projection: potential for R2 measurement of iron-loaded liver. Magn Reson Imaging 21:519\u2013530","journal-title":"Magn Reson Imaging"},{"key":"7010_CR9","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1002\/mrm.20697","volume":"54","author":"NR Ghugre","year":"2005","unstructured":"Ghugre NR, Coates TD, Nelson MD, Wood JC (2005) Mechanisms of tissue-iron relaxivity: nuclear magnetic resonance studies of human liver biopsy specimens. Magn Reson Med 54:1185\u20131193","journal-title":"Magn Reson Med"},{"key":"7010_CR10","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1002\/nbm.903","volume":"17","author":"Y Gossuin","year":"2004","unstructured":"Gossuin Y, Muller RN, Gillis P (2004) Relaxation induced by ferritin: a better understanding for an improved MRI iron quantification. NMR Biomed 17:427\u2013432","journal-title":"NMR Biomed"},{"key":"7010_CR11","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1007\/s00261-011-9762-5","volume":"37","author":"L Marti-Bonmati","year":"2012","unstructured":"Marti-Bonmati L, Alberich-Bayarri A, Sanchez-Gonzalez J (2012) Overload hepatitides: quanti-qualitative analysis. Abdom Imaging 37:180\u2013187","journal-title":"Abdom Imaging"},{"key":"7010_CR12","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1002\/jmri.25630","volume":"46","author":"B Henninger","year":"2017","unstructured":"Henninger B, Zoller H, Kannengiesser S, Zhong X, Jaschke W, Kremser C (2017) 3D multiecho Dixon for the evaluation of hepatic iron and fat in a clinical setting. J Magn Reson Imaging 46:793\u2013800","journal-title":"J Magn Reson Imaging"},{"key":"7010_CR13","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1159\/000282080","volume":"28","author":"S Bellentani","year":"2010","unstructured":"Bellentani S, Scaglioni F, Marino M, Bedogni G (2010) Epidemiology of non-alcoholic fatty liver disease. Dig Dis 28:155\u2013161","journal-title":"Dig Dis"},{"key":"7010_CR14","doi-asserted-by":"crossref","first-page":"173","DOI":"10.23736\/S0391-1977.16.02565-7","volume":"42","author":"C Datz","year":"2017","unstructured":"Datz C, Muller E, Aigner E (2017) Iron overload and non-alcoholic fatty liver disease. Minerva Endocrinol 42:173\u2013183","journal-title":"Minerva Endocrinol"},{"key":"7010_CR15","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1007\/s00330-013-2829-7","volume":"23","author":"B Henninger","year":"2013","unstructured":"Henninger B, Kremser C, Rauch S et al (2013) Evaluation of liver fat in the presence of iron with MRI using T2* correction: a clinical approach. Eur Radiol 23:1643\u20131649","journal-title":"Eur Radiol"},{"key":"7010_CR16","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1148\/radiol.12112520","volume":"265","author":"JP Kuhn","year":"2012","unstructured":"Kuhn JP, Hernando D, Munoz del Rio A et al (2012) Effect of multipeak spectral modeling of fat for liver iron and fat quantification: correlation of biopsy with MR imaging results. Radiology 265:133\u2013142","journal-title":"Radiology"},{"key":"7010_CR17","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1002\/jmri.25382","volume":"45","author":"DE Horng","year":"2017","unstructured":"Horng DE, Hernando D, Reeder SB (2017) Quantification of liver fat in the presence of iron overload. J Magn Reson Imaging 45:428\u2013439","journal-title":"J Magn Reson Imaging"},{"key":"7010_CR18","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1016\/j.mri.2012.03.002","volume":"30","author":"O Papakonstantinou","year":"2012","unstructured":"Papakonstantinou O, Foufa K, Benekos O et al (2012) Use of fat suppression in R(2) relaxometry with MRI for the quantification of tissue iron overload in beta-thalassemic patients. Magn Reson Imaging 30:926\u2013933","journal-title":"Magn Reson Imaging"},{"key":"7010_CR19","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1055\/s-0035-1550887","volume":"187","author":"B Henninger","year":"2015","unstructured":"Henninger B, Zoller H, Rauch S et al (2015) R2* relaxometry for the quantification of hepatic iron overload: biopsy-based calibration and comparison with the literature. Rofo 187:472\u2013479","journal-title":"Rofo"},{"key":"7010_CR20","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.ejrad.2017.02.006","volume":"89","author":"B Henninger","year":"2017","unstructured":"Henninger B, Rauch S, Zoller H, Plaikner M, Jaschke W, Kremser C (2017) R2*-relaxometry of the pancreas in patients with human hemochromatosis protein associated hereditary hemochromatosis. Eur J Radiol 89:149\u2013155","journal-title":"Eur J Radiol"},{"key":"7010_CR21","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1002\/mrm.25868","volume":"76","author":"AJ Krafft","year":"2016","unstructured":"Krafft AJ, Loeffler RB, Song R et al (2016) Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T. Magn Reson Med 76:591\u2013601","journal-title":"Magn Reson Med"},{"key":"7010_CR22","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1088\/0031-9155\/30\/4\/008","volume":"30","author":"A Haase","year":"1985","unstructured":"Haase A, Frahm J, Hanicke W, Matthaei D (1985) 1H NMR chemical shift selective (CHESS) imaging. Phys Med Biol 30:341\u2013344","journal-title":"Phys Med Biol"},{"key":"7010_CR23","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1148\/radiol.2523082084","volume":"252","author":"N Pineda","year":"2009","unstructured":"Pineda N, Sharma P, Xu Q, Hu X, Vos M, Martin DR (2009) Measurement of hepatic lipid: high-speed T2-corrected multiecho acquisition at 1H MR spectroscopy--a rapid and accurate technique. Radiology 252:568\u2013576","journal-title":"Radiology"},{"key":"7010_CR24","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","volume":"9","author":"CA Schneider","year":"2012","unstructured":"Schneider CA, Rasband WS, Eliceiri KW (2012) NIH image to ImageJ: 25 years of image analysis. Nat Methods 9:671\u2013675","journal-title":"Nat Methods"},{"key":"7010_CR25","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1002\/mrm.21744","volume":"60","author":"T He","year":"2008","unstructured":"He T, Gatehouse PD, Smith GC, Mohiaddin RH, Pennell DJ, Firmin DN (2008) Myocardial T2* measurements in iron-overloaded thalassemia: an in vivo study to investigate optimal methods of quantification. Magn Reson Med 60:1082\u20131089","journal-title":"Magn Reson Med"},{"key":"7010_CR26","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1111\/bjh.12296","volume":"161","author":"A Meloni","year":"2013","unstructured":"Meloni A, Rienhoff HY Jr, Jones A, Pepe A, Lombardi M, Wood JC (2013) The use of appropriate calibration curves corrects for systematic differences in liver R2* values measured using different software packages. Br J Haematol 161:888\u2013891","journal-title":"Br J Haematol"},{"key":"7010_CR27","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/S0140-6736(04)15436-6","volume":"363","author":"Y Gandon","year":"2004","unstructured":"Gandon Y, Olivie D, Guyader D et al (2004) Non-invasive assessment of hepatic iron stores by MRI. Lancet 363:357\u2013362","journal-title":"Lancet"},{"key":"7010_CR28","doi-asserted-by":"crossref","unstructured":"European European Association For The Study Of The Liver (2010) EASL clinical practice guidelines for HFE hemochromatosis. J Hepatol 53:3\u201322","DOI":"10.1016\/j.jhep.2010.03.001"},{"key":"7010_CR29","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/S0168-8278(01)80874-6","volume":"33","author":"P Adams","year":"2000","unstructured":"Adams P, Brissot P, Powell LW (2000) EASL International Consensus Conference on Haemochromatosis. J Hepatol 33:485\u2013504","journal-title":"J Hepatol"},{"key":"7010_CR30","doi-asserted-by":"crossref","unstructured":"European Association for the Study of the Liver (EASL); European Association for the Study of Diabetes (EASD); European Association for the Study of Obesity (EASO) (2016) EASL-EASD-EASO clinical practice guidelines for the management of non-alcoholic fatty liver disease. J Hepatol 64:1388\u20131402","DOI":"10.1016\/j.jhep.2015.11.004"},{"key":"7010_CR31","doi-asserted-by":"crossref","first-page":"255","DOI":"10.2307\/2532051","volume":"45","author":"LI Lin","year":"1989","unstructured":"Lin LI (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255\u2013268","journal-title":"Biometrics"},{"key":"7010_CR32","unstructured":"Stevenson M, Nunes T, Heuer C et al (2018) epiR: tools for the analysis of epidemiological data. Available via https:\/\/CRAN.R-project.org\/package=epiR"},{"key":"7010_CR33","doi-asserted-by":"crossref","first-page":"625","DOI":"10.2214\/AJR.14.12786","volume":"204","author":"A Meloni","year":"2015","unstructured":"Meloni A, Tyszka JM, Pepe A, Wood JC (2015) Effect of inversion recovery fat suppression on hepatic R2* quantitation in transfusional siderosis. AJR Am J Roentgenol 204:625\u2013629","journal-title":"AJR Am J Roentgenol"},{"key":"7010_CR34","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1016\/j.mri.2013.07.013","volume":"31","author":"L Sanches-Rocha","year":"2013","unstructured":"Sanches-Rocha L, Serpa B, Figueiredo E, Hamerschlak N, Baroni R (2013) Comparison between multi-echo T2* with and without fat saturation pulse for quantification of liver iron overload. Magn Reson Imaging 31:1704\u20131708","journal-title":"Magn Reson Imaging"},{"key":"7010_CR35","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1111\/jgh.12451","volume":"29","author":"CH Wu","year":"2014","unstructured":"Wu CH, Ho MC, Jeng YM et al (2014) Quantification of hepatic steatosis: a comparison of the accuracy among multiple magnetic resonance techniques. J Gastroenterol Hepatol 29:807\u2013813","journal-title":"J Gastroenterol Hepatol"},{"key":"7010_CR36","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1002\/mrm.25681","volume":"75","author":"X Wang","year":"2016","unstructured":"Wang X, Hernando D, Reeder SB (2016) Sensitivity of chemical shift-encoded fat quantification to calibration of fat MR spectrum. Magn Reson Med 75:845\u2013851","journal-title":"Magn Reson Med"},{"key":"7010_CR37","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1046\/j.1365-2141.2001.03195.x","volume":"115","author":"JB Porter","year":"2001","unstructured":"Porter JB (2001) Practical management of iron overload. Br J Haematol 115:239\u2013252","journal-title":"Br J Haematol"},{"key":"7010_CR38","doi-asserted-by":"publisher","unstructured":"Henninger B, Alustiza J, Garbowski M, Gandon Y (2019) Practical guide to quantification of hepatic iron with MRI. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-019-06380-9","DOI":"10.1007\/s00330-019-06380-9"},{"key":"7010_CR39","doi-asserted-by":"crossref","first-page":"2022","DOI":"10.1007\/s00330-017-5106-3","volume":"28","author":"G d\u2019Assignies","year":"2018","unstructured":"d\u2019Assignies G, Paisant A, Bardou-Jacquet E et al (2018) Non-invasive measurement of liver iron concentration using 3-Tesla magnetic resonance imaging: validation against biopsy. Eur Radiol 28:2022\u20132030","journal-title":"Eur Radiol"},{"key":"7010_CR40","doi-asserted-by":"crossref","first-page":"3494","DOI":"10.1007\/s00330-017-5263-4","volume":"28","author":"H Lin","year":"2018","unstructured":"Lin H, Wei H, He N et al (2018) Quantitative susceptibility mapping in combination with water-fat separation for simultaneous liver iron and fat fraction quantification. Eur Radiol 28:3494\u20133504","journal-title":"Eur Radiol"},{"key":"7010_CR41","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1002\/mrm.24593","volume":"70","author":"D Hernando","year":"2013","unstructured":"Hernando D, Kramer JH, Reeder SB (2013) Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation. Magn Reson Med 70:1319\u20131331","journal-title":"Magn Reson Med"},{"key":"7010_CR42","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/s42000-018-0012-x","volume":"17","author":"E Chartampilas","year":"2018","unstructured":"Chartampilas E (2018) Imaging of nonalcoholic fatty liver disease and its clinical utility. Hormones (Athens) 17:69\u201381","journal-title":"Hormones (Athens)"},{"key":"7010_CR43","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1002\/jmri.21837","volume":"30","author":"JR van Werven","year":"2009","unstructured":"van Werven JR, Hoogduin JM, Nederveen AJ et al (2009) Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content. J Magn Reson Imaging 30:444\u2013448","journal-title":"J Magn Reson Imaging"},{"key":"7010_CR44","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/RMR.0000000000000141","volume":"26","author":"CW Hong","year":"2017","unstructured":"Hong CW, Fazeli Dehkordy S, Hooker JC, Hamilton G, Sirlin CB (2017) Fat quantification in the abdomen. Top Magn Reson Imaging 26:221\u2013227","journal-title":"Top Magn Reson Imaging"},{"key":"7010_CR45","doi-asserted-by":"crossref","first-page":"2246","DOI":"10.1007\/s00330-018-5783-6","volume":"29","author":"A Meloni","year":"2019","unstructured":"Meloni A, De Marchi D, Pistoia L et al (2019) Multicenter validation of the magnetic resonance T2* technique for quantification of pancreatic iron. Eur Radiol 29:2246\u20132252","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07010-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-020-07010-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07010-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,28]],"date-time":"2022-10-28T10:55:13Z","timestamp":1666954513000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-020-07010-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,13]]},"references-count":45,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["7010"],"URL":"https:\/\/doi.org\/10.1007\/s00330-020-07010-5","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"type":"print","value":"0938-7994"},{"type":"electronic","value":"1432-1084"}],"subject":[],"published":{"date-parts":[[2020,6,13]]},"assertion":[{"value":"22 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 June 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Christian Kremser.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Even if no complex statistical methods were necessary for this paper one of the authors has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 diagnostic or prognostic study\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}