{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T21:25:48Z","timestamp":1785619548078,"version":"3.56.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,9,9]],"date-time":"2020-09-09T00:00:00Z","timestamp":1599609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,9,9]],"date-time":"2020-09-09T00:00:00Z","timestamp":1599609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Canon Medical System"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1007\/s00330-020-07212-x","type":"journal-article","created":{"date-parts":[[2020,9,10]],"date-time":"2020-09-10T12:45:08Z","timestamp":1599741908000},"page":"1578-1587","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Comparison of liver stiffness measurements by a 2D-shear wave technique and transient elastography: results from a European prospective multi-centre study"],"prefix":"10.1007","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7464-3939","authenticated-orcid":false,"given":"Maxime","family":"Ronot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanna","family":"Ferraioli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans-Peter","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mireen","family":"Friedrich-Rust","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"Filice","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Val\u00e9rie","family":"Vilgrain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Cosgrove","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrian K.","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,9,9]]},"reference":[{"key":"7212_CR1","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1186\/s12916-014-0145-y","volume":"12","author":"AA Mokdad","year":"2014","unstructured":"Mokdad AA, Lopez AD, Shahraz S et al (2014) Liver cirrhosis mortality in 187 countries between 1980 and 2010: a systematic analysis. BMC Med 12:145","journal-title":"BMC Med"},{"key":"7212_CR2","doi-asserted-by":"crossref","unstructured":"Gower E, Estes C, Blach, Razavi-Shearer K, Razavi H (2014) Global epidemiology and genotype distribution of the hepatitis C virus infection. J Hepatol 61:S45\u2013S57","DOI":"10.1016\/j.jhep.2014.07.027"},{"key":"7212_CR3","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1016\/j.jhep.2018.05.011","volume":"69","author":"L Pimpin","year":"2018","unstructured":"Pimpin L, Cortez-Pinto H, Negro F et al (2018) Burden of liver disease in Europe: epidemiology and analysis of risk factors to identify prevention policies. J Hepatol 69:718\u2013735","journal-title":"J Hepatol"},{"key":"7212_CR4","doi-asserted-by":"crossref","unstructured":"de Franchis R, Baveno VI Faculty (2015) Expanding consensus in portal hypertension: report of the Baveno VI Consensus Workshop: stratifying risk and individualizing care for portal hypertension. J Hepatol 63:743\u2013752","DOI":"10.1016\/j.jhep.2015.05.022"},{"key":"7212_CR5","first-page":"e48","volume":"38","author":"CF Dietrich","year":"2017","unstructured":"Dietrich CF, Bamber J, Berzigotti A et al (2017) EFSUMB guidelines and recommendations on the clinical use of liver ultrasound elastography, update 2017 (long version). Ultraschall Med 38:e48","journal-title":"Ultraschall Med"},{"key":"7212_CR6","doi-asserted-by":"publisher","first-page":"2419","DOI":"10.1016\/j.ultrasmedbio.2018.07.008","volume":"44","author":"G Ferraioli","year":"2018","unstructured":"Ferraioli G, Wong VW, Castera L et al (2018) Liver ultrasound elastography: an update to the World Federation for Ultrasound in Medicine and Biology guidelines and recommendations. Ultrasound Med Biol 44:2419\u20132440","journal-title":"Ultrasound Med Biol"},{"key":"7212_CR7","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1038\/nrgastro.2016.86","volume":"13","author":"M Friedrich-Rust","year":"2016","unstructured":"Friedrich-Rust M, Poynard T, Castera L (2016) Critical comparison of elastography methods to assess chronic liver disease. Nat Rev Gastroenterol Hepatol 13:402\u2013411","journal-title":"Nat Rev Gastroenterol Hepatol"},{"key":"7212_CR8","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/j.jhep.2013.10.027","volume":"60","author":"S Augustin","year":"2014","unstructured":"Augustin S, Millan L, Gonzalez A et al (2014) Detection of early portal hypertension with routine data and liver stiffness in patients with asymptomatic liver disease: a prospective study. J Hepatol 60:561\u2013569","journal-title":"J Hepatol"},{"key":"7212_CR9","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/j.jhep.2017.02.003","volume":"67","author":"A Berzigotti","year":"2017","unstructured":"Berzigotti A (2017) Non-invasive evaluation of portal hypertension using ultrasound elastography. J Hepatol 67:399\u2013411","journal-title":"J Hepatol"},{"key":"7212_CR10","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1002\/hep.29179","volume":"67","author":"E Herrmann","year":"2018","unstructured":"Herrmann E, de Ledinghen V, Cassinotto C et al (2018) Assessment of biopsy-proven liver fibrosis by two-dimensional shear wave elastography: an individual patient data-based meta-analysis. Hepatology 67:260\u2013272","journal-title":"Hepatology"},{"key":"7212_CR11","doi-asserted-by":"crossref","unstructured":"Furlan A, Tublin ME, Yu L, Chopra KB, Lippello A, Behari J (2020) Comparison of 2D shear wave elastography, transient elastography, and MR elastography for the diagnosis of fibrosis in patients with nonalcoholic fatty liver disease. AJR Am J Roentgenol 214:W20\u2013W26","DOI":"10.2214\/AJR.19.21267"},{"key":"7212_CR12","doi-asserted-by":"publisher","unstructured":"Udompap P, Sukonrut K, Suvannarerg V, Pongpaibul A, Charatcharoenwitthaya P (2019) Prospective comparison of transient elastography, point shear wave elastography, APRI and FIB-4 for staging liver fibrosis in chronic viral hepatitis. J Viral Hepat. https:\/\/doi.org\/10.1111\/jvh.13246","DOI":"10.1111\/jvh.13246"},{"key":"7212_CR13","doi-asserted-by":"publisher","first-page":"6477","DOI":"10.1007\/s00330-019-06331-4","volume":"29","author":"T Lefebvre","year":"2019","unstructured":"Lefebvre T, Wartelle-Bladou C, Wong P et al (2019) Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis. Eur Radiol 29:6477\u20136488","journal-title":"Eur Radiol"},{"key":"7212_CR14","doi-asserted-by":"crossref","unstructured":"Tsochatzis EA, Gurusamy KS, Ntaoula S, Cholongitas E, Davidson BR, Burroughs AK (2011) Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy. J Hepatol 54:650\u2013659","DOI":"10.1016\/j.jhep.2010.07.033"},{"key":"7212_CR15","doi-asserted-by":"crossref","unstructured":"Payan C, Roudot-Thoraval F, Marcellin P, et al. (2005) Changing of hepatitis C virus genotype patterns in France at the beginning of the third millenium: The GEMHEP GenoCII Study. J Viral Hepat 12:405\u2013413","DOI":"10.1111\/j.1365-2893.2005.00605.x"},{"key":"7212_CR16","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1111\/hepr.13319","volume":"49","author":"H Iijima","year":"2019","unstructured":"Iijima H, Tada T, Kumada T et al (2019) Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices. Hepatol Res 49:676\u2013686","journal-title":"Hepatol Res"},{"key":"7212_CR17","doi-asserted-by":"publisher","first-page":"2864","DOI":"10.1007\/s00261-017-1213-5","volume":"42","author":"SB Paul","year":"2017","unstructured":"Paul SB, Das P, Mahanta M et al (2017) Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography. Abdom Radiol (NY) 42:2864\u20132873","journal-title":"Abdom Radiol (NY)"},{"key":"7212_CR18","doi-asserted-by":"publisher","first-page":"2350","DOI":"10.1016\/j.ultrasmedbio.2015.04.014","volume":"41","author":"L Gerber","year":"2015","unstructured":"Gerber L, Kasper D, Fitting D et al (2015) Assessment of liver fibrosis with 2-D shear wave elastography in comparison to transient elastography and acoustic radiation force impulse imaging in patients with chronic liver disease. Ultrasound Med Biol 41:2350\u20132359","journal-title":"Ultrasound Med Biol"},{"key":"7212_CR19","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1148\/radiol.13130128","volume":"269","author":"VY Leung","year":"2013","unstructured":"Leung VY, Shen J, Wong VW et al (2013) Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: comparison of shear-wave elastography and transient elastography with liver biopsy correlation. Radiology 269:910\u2013918","journal-title":"Radiology"},{"key":"7212_CR20","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1016\/j.ultrasmedbio.2017.03.014","volume":"43","author":"J Zeng","year":"2017","unstructured":"Zeng J, Zheng J, Huang Z et al (2017) Comparison of 2-D shear wave elastography and transient elastography for assessing liver fibrosis in chronic hepatitis B. Ultrasound Med Biol 43:1563\u20131570","journal-title":"Ultrasound Med Biol"},{"key":"7212_CR21","doi-asserted-by":"publisher","first-page":"4011","DOI":"10.1007\/s00261-019-02295-7","volume":"44","author":"J Matos","year":"2019","unstructured":"Matos J, Paparo F, Bacigalupo L et al (2019) Noninvasive liver fibrosis assessment in chronic viral hepatitis C: agreement among 1D transient elastography, 2D shear wave elastography, and magnetic resonance elastography. Abdom Radiol (NY) 44:4011\u20134021","journal-title":"Abdom Radiol (NY)"},{"key":"7212_CR22","doi-asserted-by":"crossref","unstructured":"Mulabecirovic A, Mjelle AB, Gilja OH, Vesterhus M, Havre RF (2018) Liver elasticity in healthy individuals by two novel shear-wave elastography systems-comparison by age, gender, BMI and number of measurements. PLoS One 13:e0203486","DOI":"10.1371\/journal.pone.0203486"},{"key":"7212_CR23","doi-asserted-by":"publisher","first-page":"3102","DOI":"10.1016\/j.ejrad.2012.05.030","volume":"81","author":"G Ferraioli","year":"2012","unstructured":"Ferraioli G, Tinelli C, Zicchetti M et al (2012) Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. Eur J Radiol 81:3102\u20133106","journal-title":"Eur J Radiol"},{"key":"7212_CR24","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1016\/j.dld.2017.03.001","volume":"49","author":"F Piscaglia","year":"2017","unstructured":"Piscaglia F, Salvatore V, Mulazzani L et al (2017) Differences in liver stiffness values obtained with new ultrasound elastography machines and FibroScan: a comparative study. Dig Liver Dis 49:802\u2013808","journal-title":"Dig Liver Dis"},{"key":"7212_CR25","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1055\/s-0043-124184","volume":"40","author":"G Ferraioli","year":"2019","unstructured":"Ferraioli G, De Silvestri A, Lissandrin R et al (2019) Evaluation of inter-system variability in liver stiffness measurements. Ultraschall Med 40:64\u201375","journal-title":"Ultraschall Med"},{"key":"7212_CR26","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1148\/radiol.2015150619","volume":"276","author":"RG Barr","year":"2015","unstructured":"Barr RG, Ferraioli G, Palmeri ML et al (2015) Elastography assessment of liver fibrosis: Society of Radiologists in Ultrasound Consensus Conference statement. Radiology 276:845\u2013861","journal-title":"Radiology"},{"key":"7212_CR27","doi-asserted-by":"crossref","unstructured":"European Association for Study of Liver; Asociacion Latinoamericana para el Estudio del Higado (2015) EASL-ALEH clinical practice guidelines: non-invasive tests for evaluation of liver disease severity and prognosis. J Hepatol 63:237\u2013264","DOI":"10.1016\/j.jhep.2015.04.006"},{"key":"7212_CR28","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1016\/j.jhep.2014.12.007","volume":"62","author":"B Procopet","year":"2015","unstructured":"Procopet B, Berzigotti A, Abraldes JG et al (2015) Real-time shear-wave elastography: applicability, reliability and accuracy for clinically significant portal hypertension. J Hepatol 62:1068\u20131075","journal-title":"J Hepatol"},{"key":"7212_CR29","doi-asserted-by":"publisher","first-page":"268","DOI":"10.11152\/mu.2013.2066.154.isp2","volume":"15","author":"I Sporea","year":"2013","unstructured":"Sporea I, Gradinaru-Tascau O, Bota S et al (2013) How many measurements are needed for liver stiffness assessment by 2D-shear wave elastography (2D-SWE) and which value should be used: the mean or median? Med Ultrason 15:268\u2013272","journal-title":"Med Ultrason"},{"key":"7212_CR30","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1055\/s-0042-108431","volume":"38","author":"M Thiele","year":"2017","unstructured":"Thiele M, Madsen BS, Procopet B et al (2017) Reliability criteria for liver stiffness measurements with real-time 2D shear wave elastography in different clinical scenarios of chronic liver disease. Ultraschall Med 38:648\u2013654","journal-title":"Ultraschall Med"},{"key":"7212_CR31","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1148\/radiol.14141210","volume":"275","author":"L Elkrief","year":"2015","unstructured":"Elkrief L, Rautou PE, Ronot M et al (2015) Prospective comparison of spleen and liver stiffness by using shear-wave and transient elastography for detection of portal hypertension in cirrhosis. Radiology 275:589\u2013598","journal-title":"Radiology"},{"key":"7212_CR32","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1111\/liv.13243","volume":"37","author":"C Jansen","year":"2017","unstructured":"Jansen C, Bogs C, Verlinden W et al (2017) Shear-wave elastography of the liver and spleen identifies clinically significant portal hypertension: a prospective multicentre study. Liver Int 37:396\u2013405","journal-title":"Liver Int"},{"key":"7212_CR33","doi-asserted-by":"crossref","unstructured":"Fang C, Konstantatou E, Romanos O, Yusuf GT, Quinlan DJ, Sidhu PS (2017) Reproducibility of 2-dimensional shear wave elastography assessment of the liver: a direct comparison with point shear wave elastography in healthy volunteers. J Ultrasound Med 36:1563\u20131569","DOI":"10.7863\/ultra.16.07018"},{"key":"7212_CR34","doi-asserted-by":"publisher","first-page":"e0168758","DOI":"10.1371\/journal.pone.0168758","volume":"11","author":"HJ Shin","year":"2016","unstructured":"Shin HJ, Kim MJ, Kim HY et al (2016) Optimal acquisition number for hepatic shear wave velocity measurements in children. PLoS One 11:e0168758","journal-title":"PLoS One"},{"key":"7212_CR35","doi-asserted-by":"publisher","unstructured":"Roccarina D, Iogna Prat L, Buzzetti E et al (2019) Establishing reliability criteria for liver ElastPQ shear wave elastography (ElastPQ-SWE): comparison between 10, 5 and 3 measurements. Ultraschall Med. https:\/\/doi.org\/10.1055\/a-1010-6052","DOI":"10.1055\/a-1010-6052"},{"key":"7212_CR36","doi-asserted-by":"publisher","first-page":"2569","DOI":"10.1016\/j.ultrasmedbio.2018.07.028","volume":"44","author":"I Durot","year":"2018","unstructured":"Durot I, Akhbardeh A, Rosenberg J et al (2018) Point shear wave elastography for grading liver fibrosis: can the number of measurements be reduced? Ultrasound Med Biol 44:2569\u20132577","journal-title":"Ultrasound Med Biol"},{"key":"7212_CR37","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1148\/radiol.2018172104","volume":"287","author":"C Fang","year":"2018","unstructured":"Fang C, Jaffer OS, Yusuf GT et al (2018) Reducing the number of measurements in liver point shear-wave elastography: factors that influence the number and reliability of measurements in assessment of liver fibrosis in clinical practice. Radiology 287:844\u2013852","journal-title":"Radiology"},{"key":"7212_CR38","unstructured":"Vilgrain VCC, Leung VY-F, Ferraioli G et al (2015) Optimal number of 2D shear wave elastography measurements for diagnosing liver fibrosis severity. ESGAR, Paris"},{"key":"7212_CR39","doi-asserted-by":"publisher","first-page":"1056","DOI":"10.1016\/j.dld.2018.03.033","volume":"50","author":"G Ferraioli","year":"2018","unstructured":"Ferraioli G, De Silvestri A, Reiberger T et al (2018) Adherence to quality criteria improves concordance between transient elastography and ElastPQ for liver stiffness assessment-a multicenter retrospective study. Dig Liver Dis 50:1056\u20131061","journal-title":"Dig Liver Dis"},{"key":"7212_CR40","doi-asserted-by":"crossref","unstructured":"Ferraioli G, Maiocchi L, Lissandrin R et al (2016) Accuracy of the ElastPQ technique for the assessment of liver fibrosis in patients with chronic hepatitis C: a \u201creal life\u201d single center study. J Gastrointestin Liver Dis 25:331\u2013335","DOI":"10.15403\/jgld.2014.1121.253.epq"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07212-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-020-07212-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-020-07212-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,8]],"date-time":"2021-09-08T23:32:33Z","timestamp":1631143953000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-020-07212-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,9]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["7212"],"URL":"https:\/\/doi.org\/10.1007\/s00330-020-07212-x","relation":{},"ISSN":["0938-7994","1432-1084"],"issn-type":[{"value":"0938-7994","type":"print"},{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,9]]},"assertion":[{"value":"24 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Maxime Ronot.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional review board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 diagnostic or prognostic study\u2022 multi-centre study","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}