{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T18:20:51Z","timestamp":1790965251196,"version":"4.1.0"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,1,15]],"date-time":"2022-01-15T00:00:00Z","timestamp":1642204800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,15]],"date-time":"2022-01-15T00:00:00Z","timestamp":1642204800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100014718","name":"Innovative Research Group Project of the National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["Grant 82071886"],"award-info":[{"award-number":["Grant 82071886"]}],"id":[{"id":"10.13039\/100014718","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1007\/s00330-021-08415-6","type":"journal-article","created":{"date-parts":[[2022,1,14]],"date-time":"2022-01-14T19:05:35Z","timestamp":1642187135000},"page":"2988-2997","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Capability of intravoxel incoherent motion and diffusion tensor imaging to detect early kidney injury in type 2 diabetes"],"prefix":"10.1007","volume":"32","author":[{"given":"Haoran","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dafa","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanfei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuedan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siyuan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guangsong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ke","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,15]]},"reference":[{"key":"8415_CR1","unstructured":"GBD Chronic Kidney Disease Collaboration (2020) Global, regional, and national burden of chronic kidney disease, 1990\u20132017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet 395:709\u2013733"},{"key":"8415_CR2","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1038\/s41581-019-0135-6","volume":"15","author":"M Kato","year":"2019","unstructured":"Kato M, Natarajan R (2019) Epigenetics and epigenomics in diabetic kidney disease and metabolic memory. Nat Rev Nephrol 15:327\u2013345","journal-title":"Nat Rev Nephrol"},{"key":"8415_CR3","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.2215\/CJN.11111016","volume":"12","author":"SM Doshi","year":"2017","unstructured":"Doshi SM, Friedman AN (2017) Diagnosis and management of type 2 diabetic kidney disease. Clin J Am Soc Nephrol 12:1366\u20131373","journal-title":"Clin J Am Soc Nephrol"},{"key":"8415_CR4","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1016\/S0140-6736(12)61350-6","volume":"380","author":"CS Fox","year":"2012","unstructured":"Fox CS, Matsushita K, Woodward M et al (2012) Associations of kidney disease measures with mortality and end-stage renal disease in individuals with and without diabetes: a meta-analysis. Lancet 380:1662\u20131673","journal-title":"Lancet"},{"key":"8415_CR5","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jfma.2018.02.007","volume":"117","author":"YC Lin","year":"2018","unstructured":"Lin YC, Chang YH, Yang SY, Wu KD, Chu TS (2018) Update of pathophysiology and management of diabetic kidney disease. J Formos Med Assoc 117:662\u2013675","journal-title":"J Formos Med Assoc"},{"key":"8415_CR6","doi-asserted-by":"publisher","first-page":"1975","DOI":"10.1016\/S0140-6736(14)61601-9","volume":"385","author":"T Liyanage","year":"2015","unstructured":"Liyanage T, Ninomiya T, Jha V et al (2015) Worldwide access to treatment for end-stage kidney disease: a systematic review. Lancet 385:1975\u20131982","journal-title":"Lancet"},{"key":"8415_CR7","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.molmet.2019.10.005","volume":"30","author":"H Fu","year":"2019","unstructured":"Fu H, Liu S, Bastacky SI, Wang X, Tian XJ, Zhou D (2019) Diabetic kidney diseases revisited: a new perspective for a new era. Mol Metab 30:250\u2013263","journal-title":"Mol Metab"},{"key":"8415_CR8","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1007\/s00125-018-4567-5","volume":"61","author":"HM Colhoun","year":"2018","unstructured":"Colhoun HM, Marcovecchio ML (2018) Biomarkers of diabetic kidney disease. Diabetologia 61:996\u20131011","journal-title":"Diabetologia"},{"key":"8415_CR9","doi-asserted-by":"publisher","first-page":"108082","DOI":"10.1016\/j.diabres.2020.108082","volume":"161","author":"S Hussain","year":"2020","unstructured":"Hussain S, Habib A, Hussain MS, Najmi AK (2020) Potential biomarkers for early detection of diabetic kidney disease. Diabetes Res Clin Pract 161:108082","journal-title":"Diabetes Res Clin Pract"},{"key":"8415_CR10","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1080\/10408363.2017.1377682","volume":"54","author":"N Papadopoulou-Marketou","year":"2017","unstructured":"Papadopoulou-Marketou N, Kanaka-Gantenbein C, Marketos N, Chrousos GP, Papassotiriou I (2017) Biomarkers of diabetic nephropathy: A 2017 update. Crit Rev Clin Lab Sci 54:326\u2013342","journal-title":"Crit Rev Clin Lab Sci"},{"key":"8415_CR11","doi-asserted-by":"publisher","first-page":"ii29","DOI":"10.1093\/ndt\/gfy163","volume":"33","author":"A Caroli","year":"2018","unstructured":"Caroli A, Schneider M, Friedli I et al (2018) Diffusion-weighted magnetic resonance imaging to assess diffuse renal pathology: a systematic review and statement paper. Nephrol Dial Transplant 33:ii29\u2013ii40","journal-title":"Nephrol Dial Transplant"},{"key":"8415_CR12","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1007\/s00330-014-3461-x","volume":"25","author":"Z Liu","year":"2015","unstructured":"Liu Z, Xu Y, Zhang J et al (2015) Chronic kidney disease: pathological and functional assessment with diffusion tensor imaging at 3T MR. Eur Radiol 25:652\u2013660","journal-title":"Eur Radiol"},{"key":"8415_CR13","doi-asserted-by":"publisher","first-page":"1678","DOI":"10.1007\/s00330-012-2749-y","volume":"23","author":"C Gaudiano","year":"2013","unstructured":"Gaudiano C, Clementi V, Busato F et al (2013) Diffusion tensor imaging and tractography of the kidneys: assessment of chronic parenchymal diseases. Eur Radiol 23:1678\u20131685","journal-title":"Eur Radiol"},{"key":"8415_CR14","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s11684-014-0365-8","volume":"8","author":"X Chen","year":"2014","unstructured":"Chen X, Xiao W, Li X, He J, Huang X, Tan Y (2014) In vivo evaluation of renal function using diffusion weighted imaging and diffusion tensor imaging in type 2 diabetics with normoalbuminuria versus microalbuminuria. Front Med 8:471\u2013476","journal-title":"Front Med"},{"key":"8415_CR15","doi-asserted-by":"publisher","first-page":"853","DOI":"10.3348\/kjr.2016.17.6.853","volume":"17","author":"Y Ding","year":"2016","unstructured":"Ding Y, Zeng M, Rao S, Chen C, Fu C, Zhou J (2016) Comparison of Biexponential and monoexponential model of diffusion-weighted imaging for distinguishing between common renal cell carcinoma and fat poor angiomyolipoma. Korean J Radiol 17:853\u2013863","journal-title":"Korean J Radiol"},{"key":"8415_CR16","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1002\/jmri.25524","volume":"46","author":"H Li","year":"2017","unstructured":"Li H, Liang L, Li A et al (2017) Monoexponential, biexponential, and stretched exponential diffusion-weighted imaging models: quantitative biomarkers for differentiating renal clear cell carcinoma and minimal fat angiomyolipoma. J Magn Reson Imaging 46:240\u2013247","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR17","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1002\/jmri.25519","volume":"46","author":"S van Baalen","year":"2017","unstructured":"van Baalen S, Leemans A, Dik P, Lilien MR, Ten Haken B, Froeling M (2017) Intravoxel incoherent motion modeling in the kidneys: comparison of mono-, bi-, and triexponential fit. J Magn Reson Imaging 46:228\u2013239","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR18","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.neuroimage.2017.12.062","volume":"187","author":"D Le Bihan","year":"2019","unstructured":"Le Bihan D (2019) What can we see with IVIM MRI? Neuroimage 187:56\u201367","journal-title":"Neuroimage"},{"key":"8415_CR19","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.mri.2017.12.010","volume":"47","author":"W Mao","year":"2018","unstructured":"Mao W, Zhou J, Zeng M et al (2018) Intravoxel incoherent motion diffusion-weighted imaging for the assessment of renal fibrosis of chronic kidney disease: a preliminary study. Magn Reson Imaging 47:118\u2013124","journal-title":"Magn Reson Imaging"},{"key":"8415_CR20","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1097\/RLI.0000000000000066","volume":"49","author":"B Ebrahimi","year":"2014","unstructured":"Ebrahimi B, Rihal N, Woollard JR, Krier JD, Eirin A, Lerman LO (2014) Assessment of renal artery stenosis using intravoxel incoherent motion diffusion-weighted magnetic resonance imaging analysis. Invest Radiol 49:640\u2013646","journal-title":"Invest Radiol"},{"key":"8415_CR21","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1016\/j.ejrad.2014.01.024","volume":"83","author":"Q Li","year":"2014","unstructured":"Li Q, Li J, Zhang L, Chen Y, Zhang M, Yan F (2014) Diffusion-weighted imaging in assessing renal pathology of chronic kidney disease: a preliminary clinical study. Eur J Radiol 83:756\u2013762","journal-title":"Eur J Radiol"},{"key":"8415_CR22","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1002\/jmri.25861","volume":"47","author":"W Mao","year":"2018","unstructured":"Mao W, Zhou J, Zeng M et al (2018) Chronic kidney disease: pathological and functional evaluation with intravoxel incoherent motion diffusion-weighted imaging. J Magn Reson Imaging 47:1251\u20131259","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR23","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.2215\/CJN.00020119","volume":"14","author":"W Wang","year":"2019","unstructured":"Wang W, Yu Y, Wen J et al (2019) Combination of functional magnetic resonance imaging and histopathologic analysis to evaluate interstitial fibrosis in kidney allografts. Clin J Am Soc Nephrol 14:1372\u20131380","journal-title":"Clin J Am Soc Nephrol"},{"key":"8415_CR24","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1002\/jmri.25158","volume":"44","author":"K Hueper","year":"2016","unstructured":"Hueper K, Khalifa AA, Brasen JH et al (2016) Diffusion-weighted imaging and diffusion tensor imaging detect delayed graft function and correlate with allograft fibrosis in patients early after kidney transplantation. J Magn Reson Imaging 44:112\u2013121","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR25","doi-asserted-by":"publisher","first-page":"201","DOI":"10.3348\/kjr.2018.19.2.201","volume":"19","author":"Y Xie","year":"2018","unstructured":"Xie Y, Li Y, Wen J et al (2018) Functional evaluation of transplanted kidneys with reduced field-of-view diffusion-weighted imaging at 3T. Korean J Radiol 19:201\u2013208","journal-title":"Korean J Radiol"},{"key":"8415_CR26","doi-asserted-by":"publisher","first-page":"3326","DOI":"10.1007\/s00330-017-5298-6","volume":"28","author":"YC Wang","year":"2018","unstructured":"Wang YC, Feng Y, Lu CQ, Ju S (2018) Renal fat fraction and diffusion tensor imaging in patients with early-stage diabetic nephropathy. Eur Radiol 28:3326\u20133334","journal-title":"Eur Radiol"},{"key":"8415_CR27","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1093\/ndt\/gfz066","volume":"35","author":"RS Brown","year":"2020","unstructured":"Brown RS, Sun MRM, Stillman IE, Russell TL, Rosas SE, Wei JL (2020) The utility of magnetic resonance imaging for noninvasive evaluation of diabetic nephropathy. Nephrol Dial Transplant 35:970\u2013978","journal-title":"Nephrol Dial Transplant"},{"key":"8415_CR28","doi-asserted-by":"publisher","first-page":"20190562","DOI":"10.1259\/bjr.20190562","volume":"93","author":"YZ Feng","year":"2020","unstructured":"Feng YZ, Ye YJ, Cheng ZY et al (2020) Non-invasive assessment of early stage diabetic nephropathy by DTI and BOLD MRI. Br J Radiol 93:20190562","journal-title":"Br J Radiol"},{"key":"8415_CR29","doi-asserted-by":"publisher","first-page":"487","DOI":"10.2337\/dci19-0066","volume":"43","author":"JB Buse","year":"2020","unstructured":"Buse JB, Wexler DJ, Tsapas A et al (2020) 2019 Update to: Management of Hyperglycemia in Type 2 Diabetes, 2018. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetes Care 43:487\u2013493","journal-title":"Diabetes Care"},{"key":"8415_CR30","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1002\/nbm.1486","volume":"23","author":"JS Cheung","year":"2010","unstructured":"Cheung JS, Fan SJ, Chow AM, Zhang J, Man K, Wu EX (2010) Diffusion tensor imaging of renal ischemia reperfusion injury in an experimental model. NMR Biomed 23:496\u2013502","journal-title":"NMR Biomed"},{"key":"8415_CR31","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1007\/s00330-015-3841-x","volume":"26","author":"WJ Fan","year":"2016","unstructured":"Fan WJ, Ren T, Li Q et al (2016) Assessment of renal allograft function early after transplantation with isotropic resolution diffusion tensor imaging. Eur Radiol 26:567\u2013575","journal-title":"Eur Radiol"},{"key":"8415_CR32","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1148\/radiol.12111327","volume":"263","author":"EE Sigmund","year":"2012","unstructured":"Sigmund EE, Vivier PH, Sui D et al (2012) Intravoxel incoherent motion and diffusion-tensor imaging in renal tissue under hydration and furosemide flow challenges. Radiology 263:758\u2013769","journal-title":"Radiology"},{"key":"8415_CR33","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1148\/radiol.2015150244","volume":"278","author":"M Iima","year":"2016","unstructured":"Iima M, Le Bihan D (2016) Clinical intravoxel incoherent motion and diffusion MR imaging: past, present, and future. Radiology 278:13\u201332","journal-title":"Radiology"},{"key":"8415_CR34","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1002\/jmri.26911","volume":"52","author":"JL Zhang","year":"2020","unstructured":"Zhang JL, Lee VS (2020) Renal perfusion imaging by MRI. J Magn Reson Imaging 52:369\u2013379","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR35","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.1007\/s00330-011-2189-0","volume":"21","author":"K Hueper","year":"2011","unstructured":"Hueper K, Gutberlet M, Rodt T et al (2011) Diffusion tensor imaging and tractography for assessment of renal allograft dysfunction-initial results. Eur Radiol 21:2427\u20132433","journal-title":"Eur Radiol"},{"key":"8415_CR36","doi-asserted-by":"publisher","first-page":"4913","DOI":"10.1007\/s00330-017-4906-9","volume":"27","author":"Y Zhong","year":"2017","unstructured":"Zhong Y, Wang H, Shen Y et al (2017) Diffusion-weighted imaging versus contrast-enhanced MR imaging for the differentiation of renal oncocytomas and chromophobe renal cell carcinomas. Eur Radiol 27:4913\u20134922","journal-title":"Eur Radiol"},{"key":"8415_CR37","doi-asserted-by":"publisher","first-page":"6930","DOI":"10.1007\/s00330-019-06240-6","volume":"29","author":"Y Ding","year":"2019","unstructured":"Ding Y, Tan Q, Mao W et al (2019) Differentiating between malignant and benign renal tumors: do IVIM and diffusion kurtosis imaging perform better than DWI? Eur Radiol 29:6930\u20136939","journal-title":"Eur Radiol"},{"key":"8415_CR38","doi-asserted-by":"publisher","first-page":"W85","DOI":"10.2214\/AJR.16.16652","volume":"208","author":"AM Hotker","year":"2017","unstructured":"Hotker AM, Mazaheri Y, Wibmer A et al (2017) Differentiation of clear cell renal cell carcinoma from other renal cortical tumors by use of a quantitative multiparametric MRI approach. AJR Am J Roentgenol 208:W85\u2013W91","journal-title":"AJR Am J Roentgenol"},{"key":"8415_CR39","doi-asserted-by":"publisher","first-page":"669581","DOI":"10.3389\/fphys.2021.669581","volume":"12","author":"Y Li","year":"2021","unstructured":"Li Y, Shi D, Zhang H et al (2021) The application of functional magnetic resonance imaging in type 2 diabetes rats with contrast-induced acute kidney injury and the associated innate immune response. Front Physiol 12:669581","journal-title":"Front Physiol"},{"key":"8415_CR40","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1111\/j.2040-1124.2010.00071.x","volume":"2","author":"Y Hashimoto","year":"2011","unstructured":"Hashimoto Y, Yamagishi S, Mizukami H et al (2011) Polyol pathway and diabetic nephropathy revisited: early tubular cell changes and glomerulopathy in diabetic mice overexpressing human aldose reductase. J Diabetes Investig 2:111\u2013122","journal-title":"J Diabetes Investig"},{"key":"8415_CR41","doi-asserted-by":"publisher","first-page":"791","DOI":"10.2337\/db16-0796","volume":"66","author":"RE Gilbert","year":"2017","unstructured":"Gilbert RE (2017) Proximal tubulopathy: prime mover and key therapeutic target in diabetic kidney disease. Diabetes 66:791\u2013800","journal-title":"Diabetes"},{"key":"8415_CR42","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1016\/j.semnephrol.2012.07.009","volume":"32","author":"BD Humphreys","year":"2012","unstructured":"Humphreys BD (2012) Targeting pericyte differentiation as a strategy to modulate kidney fibrosis in diabetic nephropathy. Semin Nephrol 32:463\u2013470","journal-title":"Semin Nephrol"},{"key":"8415_CR43","doi-asserted-by":"publisher","first-page":"2103","DOI":"10.1007\/s00330-019-06530-z","volume":"30","author":"O Rouviere","year":"2020","unstructured":"Rouviere O, Cornelis F, Brunelle S et al (2020) Imaging protocols for renal multiparametric MRI and MR urography: results of a consensus conference from the French Society of Genitourinary Imaging. Eur Radiol 30:2103\u20132114","journal-title":"Eur Radiol"},{"key":"8415_CR44","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1002\/jmri.26861","volume":"51","author":"ZY Cheng","year":"2019","unstructured":"Cheng ZY, Feng YZ, Hu JJ et al (2019) Intravoxel incoherent motion imaging of the kidney: the application in patients with hyperuricemia. J Magn Reson Imaging 51:833\u2013840","journal-title":"J Magn Reson Imaging"},{"key":"8415_CR45","doi-asserted-by":"publisher","first-page":"2728","DOI":"10.1007\/s00261-018-1521-4","volume":"43","author":"Y Deng","year":"2018","unstructured":"Deng Y, Yang B, Peng Y, Liu Z, Luo J, Du G (2018) Use of intravoxel incoherent motion diffusion-weighted imaging to detect early changes in diabetic kidneys. Abdom Radiol (NY) 43:2728\u20132733","journal-title":"Abdom Radiol (NY)"},{"key":"8415_CR46","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1148\/radiol.09090891","volume":"254","author":"JL Zhang","year":"2010","unstructured":"Zhang JL, Sigmund EE, Chandarana H et al (2010) Variability of renal apparent diffusion coefficients: limitations of the monoexponential model for diffusion quantification. Radiology 254:783\u2013792","journal-title":"Radiology"},{"key":"8415_CR47","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/s10334-020-00869-x","volume":"34","author":"T Mr\u0111anin","year":"2021","unstructured":"Mr\u0111anin T, Nikoli\u0107 O, Molnar U, Mitrovi\u0107 M, Till V (2021) Diffusion-weighted imaging in the assessment of renal function in patients with diabetes mellitus type 2. MAGMA 34:273\u2013283","journal-title":"MAGMA"},{"key":"8415_CR48","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1159\/000333044","volume":"34","author":"L Lu","year":"2011","unstructured":"Lu L, Sedor JR, Gulani V et al (2011) Use of diffusion tensor MRI to identify early changes in diabetic nephropathy. Am J Nephrol 34:476\u2013482","journal-title":"Am J Nephrol"},{"key":"8415_CR49","doi-asserted-by":"publisher","first-page":"2526","DOI":"10.1007\/s00261-020-02576-6","volume":"45","author":"Y Deng","year":"2020","unstructured":"Deng Y, Yang BR, Luo JW, Du GX, Luo LP (2020) DTI-based radiomics signature for the detection of early diabetic kidney damage. Abdom Radiol (NY) 45:2526\u20132531","journal-title":"Abdom Radiol (NY)"},{"key":"8415_CR50","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1097\/RLI.0000000000000426","volume":"53","author":"VD Van Phi","year":"2018","unstructured":"Van Phi VD, Becker AS, Ciritsis A, Reiner CS, Boss A (2018) Intravoxel incoherent motion analysis of abdominal organs: application of simultaneous multislice acquisition. Invest Radiol 53:179\u2013185","journal-title":"Invest Radiol"},{"key":"8415_CR51","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1002\/mrm.27990","volume":"83","author":"OJ Gurney-Champion","year":"2020","unstructured":"Gurney-Champion OJ, Rauh SS, Harrington K, Oelfke U, Laun FB, Wetscherek A (2020) Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: an accurate and precise clinically feasible protocol. Magn Reson Med 83:1003\u20131015","journal-title":"Magn Reson Med"},{"key":"8415_CR52","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1097\/RLI.0b013e3181d83abc","volume":"45","author":"M Notohamiprodjo","year":"2010","unstructured":"Notohamiprodjo M, Dietrich O, Horger W et al (2010) Diffusion tensor imaging (DTI) of the kidney at 3 tesla-feasibility, protocol evaluation and comparison to 1.5 Tesla. Invest Radiol 45:245\u2013254","journal-title":"Invest Radiol"},{"key":"8415_CR53","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s10334-019-00790-y","volume":"33","author":"A Ljimani","year":"2020","unstructured":"Ljimani A, Caroli A, Laustsen C et al (2020) Consensus-based technical recommendations for clinical translation of renal diffusion-weighted MRI. MAGMA 33:177\u2013195","journal-title":"MAGMA"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-021-08415-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-021-08415-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-021-08415-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,25]],"date-time":"2022-04-25T12:04:09Z","timestamp":1650888249000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-021-08415-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,15]]},"references-count":53,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["8415"],"URL":"https:\/\/doi.org\/10.1007\/s00330-021-08415-6","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,15]]},"assertion":[{"value":"6 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Ke Ren.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 Prospective\u2022 Diagnostic or prognostic study\u2022 Performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}