{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T21:12:47Z","timestamp":1789765967431,"version":"4.0.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,1,6]],"date-time":"2022-01-06T00:00:00Z","timestamp":1641427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,6]],"date-time":"2022-01-06T00:00:00Z","timestamp":1641427200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s00330-021-08469-6","type":"journal-article","created":{"date-parts":[[2022,1,6]],"date-time":"2022-01-06T06:02:43Z","timestamp":1641448963000},"page":"3830-3838","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Magnetic resonance imaging safety in patients with abandoned or functioning epicardial pacing leads"],"prefix":"10.1007","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4686-3269","authenticated-orcid":false,"given":"Aino-Maija","family":"Vuorinen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riitta","family":"Paakkanen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jarkko","family":"Karvonen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juha","family":"Sinisalo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miia","family":"Holmstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sari","family":"Kivist\u00f6","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juha I.","family":"Peltonen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Touko","family":"Kaasalainen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,6]]},"reference":[{"key":"8469_CR1","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/S0002-8703(97)70083-8","volume":"134","author":"S Achenbach","year":"1997","unstructured":"Achenbach S, Moshage W, Diem B, Bieberlea T, Schibgilla V, Bachmann K (1997) Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 134:467\u2013473","journal-title":"Am Heart J"},{"key":"8469_CR2","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1016\/j.jacc.2003.12.016","volume":"43","author":"ET Martin","year":"2004","unstructured":"Martin ET, Coman JA, Shellock FG, Pulling CC, Fair R, Jenkins K (2004) Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. J Am Coll Cardiol 43:1315\u20131324","journal-title":"J Am Coll Cardiol"},{"key":"8469_CR3","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1111\/j.1540-8159.1998.tb00202.x","volume":"21","author":"JM Fontaine","year":"1998","unstructured":"Fontaine JM, Mohamed FB, Gottlieb C, Callans DJ, Marchlinski FE (1998) Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging. Pacing Clin Electrophysiol 21:1336\u20131339","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR4","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1056\/NEJMoa1603265","volume":"376","author":"RJ Russo","year":"2017","unstructured":"Russo RJ, Costa HS, Silva PD et al (2017) Assessing the risks associated with MRI in patients with a pacemaker or defibrillator. N Engl J Med 376:755\u2013764","journal-title":"N Engl J Med"},{"key":"8469_CR5","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","volume":"377","author":"S Nazarian","year":"2017","unstructured":"Nazarian S, Hansford R, Rahsepar AA et al (2017) Safety of magnetic resonance imaging in patients with cardiac devices. N Engl J Med 377:2555\u20132564","journal-title":"N Engl J Med"},{"key":"8469_CR6","doi-asserted-by":"publisher","first-page":"1378","DOI":"10.1007\/s00330-019-06449-5","volume":"30","author":"AN Bhuva","year":"2020","unstructured":"Bhuva AN, Moralee R, Moon JC, Manisty CH (2020) Making MRI available for patients with cardiac implantable electronic devices: growing need and barriers to change. Eur Radiol 30:1378\u20131384","journal-title":"Eur Radiol"},{"key":"8469_CR7","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","volume":"43","author":"M Glikson","year":"2021","unstructured":"Glikson M, Nielsen JC, Kronborg MB et al (2021) 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J 43:3427\u20133520","journal-title":"Eur Heart J"},{"key":"8469_CR8","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1111\/j.1540-8159.2009.02304.x","volume":"32","author":"AF Pulver","year":"2009","unstructured":"Pulver AF, Puchalski MD, Bradley DJ et al (2009) Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers. Pacing Clin Electrophysiol 32:450\u2013456","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR9","doi-asserted-by":"publisher","first-page":"804","DOI":"10.4070\/kcj.2016.46.6.804","volume":"46","author":"YM Hwang","year":"2016","unstructured":"Hwang YM, Kim J, Lee JH et al (2016) Cardiac implantable electronic device safety during magnetic resonance imaging. Korean Circ J 46:804\u2013810","journal-title":"Korean Circ J"},{"key":"8469_CR10","first-page":"818","volume":"19","author":"L Bertelsen","year":"2017","unstructured":"Bertelsen L, Petersen HH, Philbert BT, Svendsen JH, Thomsen C, Vejlstrup N (2017) Safety of magnetic resonance scanning without monitoring of patients with pacemakers. Europace 19:818\u2013823","journal-title":"Europace"},{"key":"8469_CR11","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1007\/s00246-020-02316-z","volume":"41","author":"M Bireley","year":"2020","unstructured":"Bireley M, Kovach JR, Morton C et al (2020) Cardiac magnetic resonance imaging (MRI) in children is safe with most pacemaker systems, including those with epicardial leads. Pediatr Cardiol 41:801\u2013808","journal-title":"Pediatr Cardiol"},{"key":"8469_CR12","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1111\/pace.13984","volume":"43","author":"L Gakenheimer-Smith","year":"2020","unstructured":"Gakenheimer-Smith L, Etheridge SP, Niu MC et al (2020) MRI in pediatric and congenital heart disease patients with CIEDs and epicardial or abandoned leads. Pacing Clin Electrophysiol 43:797\u2013804","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR13","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/j.hrthm.2017.10.022","volume":"15","author":"D Padmanabhan","year":"2018","unstructured":"Padmanabhan D, Kella DK, Mehta R et al (2018) Safety of magnetic resonance imaging in patients with legacy pacemakers and defibrillators and abandoned leads. Heart Rhythm 15:228\u2013233","journal-title":"Heart Rhythm"},{"key":"8469_CR14","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1111\/pace.13060","volume":"40","author":"AD Shah","year":"2017","unstructured":"Shah AD, Patel AU, Knezevic A et al (2017) Clinical performance of magnetic resonance imaging conditional and nonconditional cardiac implantable electronic devices. Pacing Clin Electrophysiol 40:467\u2013475","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR15","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1111\/pace.13340","volume":"41","author":"IS Nyotowidjojo","year":"2018","unstructured":"Nyotowidjojo IS, Skinner K, Shah AS et al (2018) Thoracic versus nonthoracic MR imaging for patients with an MR nonconditional cardiac implantable electronic device. Pacing Clin Electrophysiol 41:589\u2013596","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR16","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1001\/jamacardio.2020.7572","volume":"6","author":"RD Schaller","year":"2021","unstructured":"Schaller RD, Brunker T, Riley MP, Marchlinski FE, Nazarian S, Litt H (2021) Magnetic resonance imaging in patients with cardiac implantable electronic devices with abandoned leads. JAMA Cardiol 6:549\u2013556","journal-title":"JAMA Cardiol"},{"key":"8469_CR17","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1002\/jmri.24971","volume":"43","author":"S Nazarian","year":"2016","unstructured":"Nazarian S, Reynolds MR, Ryan MP, Wolff SD, Mollenkopf SA, Turakhia MP (2016) Utilization and likelihood of radiologic diagnostic imaging in patients with implantable cardiac defibrillators. J Magn Reson Imaging 43:115\u2013127","journal-title":"J Magn Reson Imaging"},{"key":"8469_CR18","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1177\/0284185119830288","volume":"60","author":"AM Vuorinen","year":"2019","unstructured":"Vuorinen AM, Pakarinen S, Jaakkola I, Holmstrom M, Kivisto S, Kaasalainen T (2019) Clinical experience of magnetic resonance imaging in patients with cardiac pacing devices: unrestricted patient population. Acta Radiol 60:1414\u20131421","journal-title":"Acta Radiol"},{"key":"8469_CR19","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1016\/j.ejrad.2014.04.022","volume":"83","author":"T Kaasalainen","year":"2014","unstructured":"Kaasalainen T, Pakarinen S, Kivisto S et al (2014) MRI with cardiac pacing devices - safety in clinical practice. Eur J Radiol 83:1387\u20131395","journal-title":"Eur J Radiol"},{"key":"8469_CR20","doi-asserted-by":"publisher","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","volume":"14","author":"JH Indik","year":"2017","unstructured":"Indik JH, Gimbel JR, Abe H et al (2017) 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm 14:e97\u2013e153","journal-title":"Heart Rhythm"},{"key":"8469_CR21","first-page":"812","volume":"19","author":"L Horwood","year":"2017","unstructured":"Horwood L, Attili A, Luba F et al (2017) Magnetic resonance imaging in patients with cardiac implanted electronic devices: focus on contraindications to magnetic resonance imaging protocols. Europace 19:812\u2013817","journal-title":"Europace"},{"key":"8469_CR22","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1109\/TDMR.2005.859033","volume":"5","author":"JA Nyenhuis","year":"2005","unstructured":"Nyenhuis JA, Sung-Min P, Kamondetdacha R, Amjad A, Shellock FG, Rezai AR (2005) MRI and implanted medical devices: basic interactions with an emphasis on heating. IEEE Tran Device and Mater Reliab 5:467\u2013480","journal-title":"IEEE Tran Device and Mater Reliab"},{"key":"8469_CR23","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1002\/mrm.25106","volume":"73","author":"E Mattei","year":"2015","unstructured":"Mattei E, Gentili G, Censi F, Triventi M, Calcagnini G (2015) Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant. Magn Reson Med 73:390\u2013400","journal-title":"Magn Reson Med"},{"key":"8469_CR24","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/0002-9149(86)90768-X","volume":"57","author":"JA Erlebacher","year":"1986","unstructured":"Erlebacher JA, Cahill PT, Pannizzo F, Knowles RJR (1986) Effect of magnetic resonance imaging on DDD pacemakers. Am J Cardiol 57:437\u2013440","journal-title":"Am J Cardiol"},{"key":"8469_CR25","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1093\/eurheartj\/ehi009","volume":"26","author":"R Luechinger","year":"2005","unstructured":"Luechinger R, Zeijlemaker VA, Pedersen EM et al (2005) In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J 26:376\u2013383","journal-title":"Eur Heart J"},{"key":"8469_CR26","first-page":"115","volume":"7","author":"AM Ferreira","year":"2014","unstructured":"Ferreira AM, Costa F, Marques H, Cardim N, Tralhao A, Adragao P (2014) MRI-conditional pacemakers: current perspectives Med Devices (Auckl) 7:115\u2013124","journal-title":"MRI-conditional pacemakers: current perspectives Med Devices (Auckl)"},{"key":"8469_CR27","doi-asserted-by":"publisher","first-page":"3828","DOI":"10.1118\/1.3439590","volume":"37","author":"PA Bottomley","year":"2010","unstructured":"Bottomley PA, Kumar A, Edelstein WA, Allen JM, Karmarkar PV (2010) Designing passive MRI-safe implantable conducting leads with electrodes. Med Phys 37:3828\u20133843","journal-title":"Med Phys"},{"key":"8469_CR28","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1016\/j.mri.2005.07.005","volume":"23","author":"RW Gray","year":"2005","unstructured":"Gray RW, Bibens WT, Shellock FG (2005) Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads. Magn Reson Imaging 23:887\u2013891","journal-title":"Magn Reson Imaging"},{"key":"8469_CR29","doi-asserted-by":"publisher","first-page":"1645","DOI":"10.1016\/j.hrthm.2019.05.031","volume":"16","author":"D Padmanabhan","year":"2019","unstructured":"Padmanabhan D, Kella DK, Deshmukh AJ et al (2019) Safety of thoracic magnetic resonance imaging for patients with pacemakers and defibrillators. Heart Rhythm 16:1645\u20131651","journal-title":"Heart Rhythm"},{"key":"8469_CR30","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s10840-019-00627-7","volume":"56","author":"C Balmer","year":"2019","unstructured":"Balmer C, Gass M, Dave H, Duru F, Luechinger R (2019) Magnetic resonance imaging of patients with epicardial leads: in vitro evaluation of temperature changes at the lead tip. J Interv Card Electrophysiol 56:321\u2013326","journal-title":"J Interv Card Electrophysiol"},{"key":"8469_CR31","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1002\/jmri.22463","volume":"33","author":"DA Langman","year":"2011","unstructured":"Langman DA, Goldberg IB, Finn JP, Ennis DB (2011) Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 tesla MRI. J Magn Reson Imaging 33:426\u2013431","journal-title":"J Magn Reson Imaging"},{"key":"8469_CR32","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1111\/pace.12419","volume":"37","author":"JV Higgins","year":"2014","unstructured":"Higgins JV, Gard JJ, Sheldon SH et al (2014) Safety and outcomes of magnetic resonance imaging in patients with abandoned pacemaker and defibrillator leads. Pacing Clin Electrophysiol 37:1284\u20131290","journal-title":"Pacing Clin Electrophysiol"},{"key":"8469_CR33","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s12968-021-00728-1","volume":"23","author":"C Gatterer","year":"2021","unstructured":"Gatterer C, Stelzm\u00fcller M-E, Kammerlander A et al (2021) Safety and image quality of cardiovascular magnetic resonance imaging in patients with retained epicardial pacing wires after heart transplantation. J Cardiovasc Magn Reson 23:24","journal-title":"J Cardiovasc Magn Reson"},{"key":"8469_CR34","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1002\/jmri.25761","volume":"47","author":"LP Panych","year":"2018","unstructured":"Panych LP, Madore B (2018) The physics of MRI safety. J Magn Reson Imaging 47:28\u201343","journal-title":"J Magn Reson Imaging"},{"key":"8469_CR35","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s10840-015-0064-7","volume":"45","author":"JV Higgins","year":"2016","unstructured":"Higgins JV, Watson RE, Jaffe AS et al (2016) Cardiac troponin T in patients with cardiac implantable electronic devices undergoing magnetic resonance imaging. J Interv Card Electrophysiol 45:91\u201397","journal-title":"J Interv Card Electrophysiol"},{"key":"8469_CR36","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1093\/europace\/eut029","volume":"15","author":"MS Silvetti","year":"2013","unstructured":"Silvetti MS, Drago F, Di Carlo D, Placidi S, Brancaccio G, Carotti A (2013) Cardiac pacing in paediatric patients with congenital heart defects: transvenous or epicardial? Europace 15:1280\u20131286","journal-title":"Europace"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-021-08469-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-021-08469-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-021-08469-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T06:08:55Z","timestamp":1653026935000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-021-08469-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,6]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["8469"],"URL":"https:\/\/doi.org\/10.1007\/s00330-021-08469-6","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,6]]},"assertion":[{"value":"1 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 November 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Touko Kaasalainen.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: Abbott (Jarkko Karvonen), Medtronic (Jarkko Karvonen).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was not required for this study because research based purely on documentation or registered materials does not need to be reviewed by the regional ethics committees and informed written consent is not required for research based on purely documentation.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.Research based purely on documentation or registered materials does not need to be reviewed by the regional ethics committees.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Some study subjects or cohorts have been previously reported in Vuorinen AM, Pakarinen S, Jaakkola I, Holmstrom M, Kivisto S, Kaasalainen T (2019) Clinical experience of magnetic resonance imaging in patients with cardiac pacing devices: unrestricted patient population. Acta Radiol 60:1414\u20131421. Seven MRIs in seven patients with functioning or abandoned epicardial leads were included in this previous publication and are also included in this study. However, our previous article concentrated on the general safety of MRI in patients with CIED and on the MRI safety protocol. Patients with functioning epicardial pacing leads remained without specific note. This publication concentrates specifically in the subgroup of patients with epicardial pacing leads and adds valuable information in this setting.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 retrospective\u2022 observational\u2022 performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}