{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T07:14:48Z","timestamp":1793344488534,"version":"4.5.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T00:00:00Z","timestamp":1656547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T00:00:00Z","timestamp":1656547200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000892","name":"Prostate Cancer Foundation","doi-asserted-by":"publisher","award":["20YOUN15"],"award-info":[{"award-number":["20YOUN15"]}],"id":[{"id":"10.13039\/100000892","id-type":"DOI","asserted-by":"publisher"}]},{"name":"European School of Radiology","award":["FG has been the recipient of the 2021 ESOR Nicholas Gourtsoyiannis teaching fellowship"],"award-info":[{"award-number":["FG has been the recipient of the 2021 ESOR Nicholas Gourtsoyiannis teaching fellowship"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant\u2019s ability to apply PI-QUAL.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50\u20130.66]) to post-teaching (0.96 [0.92\u20130.98]), an improvement of 0.37 [0.21\u20130.41] (<jats:italic>p<\/jats:italic> &lt; 0.001).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Key Points<\/jats:title>\n                <jats:p>\u2022 <jats:italic>A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention.<\/jats:italic><\/jats:p>\n                <jats:p>\u2022 <jats:italic>Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI.<\/jats:italic><\/jats:p>\n                <jats:p>\u2022 <jats:italic>Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.<\/jats:italic><\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00330-022-08947-5","type":"journal-article","created":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T05:03:01Z","timestamp":1656565381000},"page":"461-471","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Promoting the use of the PI-QUAL score for prostate MRI quality: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5218-6431","authenticated-orcid":false,"given":"Francesco","family":"Giganti","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander P.","family":"Cole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fiona M.","family":"Fennessy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy","family":"Clinton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro Lopes Da Frota","family":"Moreira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariana Costa","family":"Bernardes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carl-Fredrik","family":"Westin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepa","family":"Krishnaswamy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andriy","family":"Fedorov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel A.","family":"Wollin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bjoern","family":"Langbein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Frego","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhieddine","family":"Labban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joy S.","family":"Badaoui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven L.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Logan G.","family":"Briggs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junichi","family":"Tokuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Ambrosi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alex","family":"Kirkham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Emberton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veeru","family":"Kasivisvanathan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caroline M.","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clare","family":"Allen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clare M.","family":"Tempany","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,30]]},"reference":[{"key":"8947_CR1","doi-asserted-by":"publisher","unstructured":"Karanasios E, Caglic I, Zawaideh JP, Barrett TL (2022) Prostate MRI quality: clinical impact of the PI-QUAL score in prostate cancer diagnostic work-up. Br J Radiol 1;95(1133):20211372. https:\/\/doi.org\/10.1259\/bjr.20211372","DOI":"10.1259\/bjr.20211372"},{"issue":"1","key":"8947_CR2","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.eururo.2015.08.052","volume":"69","author":"JC Weinreb","year":"2016","unstructured":"Weinreb JC, Barentsz JO, Choyke PL et al (2016) PI-RADS prostate imaging-reporting and data system: 2015, Version 2. Eur Urol 69(1):16\u201340","journal-title":"Eur Urol"},{"key":"8947_CR3","first-page":"1","volume":"0232","author":"B Turkbey","year":"2019","unstructured":"Turkbey B, Rosenkrantz AB, Haider MA et al (2019) Prostate Imaging Reporting and Data System Version 2.1: 2019 Update of Prostate Imaging Reporting and Data System Version 2. Eur Urol 0232:1\u201312","journal-title":"Eur Urol"},{"issue":"10","key":"8947_CR4","doi-asserted-by":"publisher","first-page":"5404","DOI":"10.1007\/s00330-020-06929-z","volume":"30","author":"M De Rooij","year":"2020","unstructured":"De Rooij M, Isra\u00ebl B, Tummers M et al (2020) ESUR \/ ESUI consensus statements on multi-parametric MRI for the detection of clinically significant prostate cancer: quality requirements for image acquisition, interpretation, and radiologists\u2019 training. Eur Radiol 30(10):5404\u20135416","journal-title":"Eur Radiol"},{"issue":"1","key":"8947_CR5","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1111\/bju.14361","volume":"122","author":"M Brizmohun Appayya","year":"2018","unstructured":"Brizmohun Appayya M, Adshead J, Ahmed H et al (2018) National implementation of multi-parametric MRI for prostate cancer detection - recommendations from a UK consensus meeting. BJU Int 122(1):13\u201325","journal-title":"BJU Int"},{"issue":"5","key":"8947_CR6","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.euo.2020.06.007","volume":"3","author":"F Giganti","year":"2020","unstructured":"Giganti F, Allen C, Emberton M, Moore CM, Kasivisvanathan V (2020) Prostate Imaging Quality (PI-QUAL): a new quality control scoring system for multiparametric magnetic resonance imaging of the prostate from the PRECISION trial. Eur Urol Oncol 3(5):615\u2013619","journal-title":"Eur Urol Oncol"},{"key":"8947_CR7","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1007\/s00330-009-1625-x","volume":"20","author":"O Akin","year":"2010","unstructured":"Akin O, Riedl CC, Ishill NM, Moskowitz CS, Zhang J, Hricak H (2010) Interactive dedicated training curriculum improves accuracy in the interpretation of MR imaging of prostate cancer. Eur Radiol 20:995\u20131002","journal-title":"Eur Radiol"},{"issue":"3","key":"8947_CR8","doi-asserted-by":"publisher","first-page":"W92","DOI":"10.2214\/AJR.16.16876","volume":"208","author":"AB Rosenkrantz","year":"2017","unstructured":"Rosenkrantz AB, Ayoola A, Hoffman D et al (2017) The learning curve in prostate MRI Interpretation: self-directed learning versus continual reader feedback. AJR Am J Roentgenol 208(3):W92\u2013W100","journal-title":"AJR Am J Roentgenol"},{"issue":"11","key":"8947_CR9","doi-asserted-by":"publisher","first-page":"894.e19","DOI":"10.1016\/j.crad.2019.03.026","volume":"74","author":"PR Burn","year":"2019","unstructured":"Burn PR, Freeman SJ, Andreou A, Burns-Cox N, Persad R, Barrett T (2019) A multicentre assessment of prostate MRI quality and compliance with UK and international standards. Clin Radiol 74(11):894.e19\u2013894.e25","journal-title":"Clin Radiol"},{"issue":"1","key":"8947_CR10","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1186\/s13244-021-00996-6","volume":"12","author":"F Giganti","year":"2021","unstructured":"Giganti F, Kirkham A, Kasivisvanathan V et al (2021) Understanding PI-QUAL for prostate MRI quality: a practical primer for radiologists. Insights Imaging 12(1):59","journal-title":"Insights Imaging"},{"key":"8947_CR11","doi-asserted-by":"crossref","first-page":"S22","DOI":"10.1016\/S1076-6332(05)80441-6","volume":"2","author":"NA Obuchowski","year":"1995","unstructured":"Obuchowski NA (1995) Multireader, multimodality receiver operating characteristic curve studies: hypothesis testing and sample size estimation using an analysis of variance approach with dependent observations. Acad Radiol 2:S22\u2013S29 discussion S57-64, S70-1 pas","journal-title":"Acad Radiol"},{"key":"8947_CR12","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1177\/0962280215579476","volume":"26","author":"W Liu","year":"2017","unstructured":"Liu W, Pantoja-Galicia N, Zhang B et al (2017) Generalized linear mixed models for multi-reader multi-case studies of diagnostic tests. Stat Methods Med Res 26:1373\u20131388","journal-title":"Stat Methods Med Res"},{"issue":"2","key":"8947_CR13","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1177\/0284185115574873","volume":"57","author":"T Kaasalainen","year":"2016","unstructured":"Kaasalainen T, Kivist\u00f6 S, Holmstr\u00f6m M et al (2016) Cardiac MRI in patients with cardiac pacemakers: practical methods for reducing susceptibility artifacts and optimizing image quality. Acta Radiol 57(2):178\u2013187","journal-title":"Acta Radiol"},{"issue":"3","key":"8947_CR14","doi-asserted-by":"publisher","first-page":"634","DOI":"10.2214\/AJR.09.2994","volume":"194","author":"AB Rosenkrantz","year":"2010","unstructured":"Rosenkrantz AB, Patel JM, Babb JS, Storey P, Hecht EM (2010) Liver MRI at 3 T using a respiratory-triggered time-efficient 3D T2-weighted technique: impact on artifacts and image quality. AJR Am J Roentgenol 194(3):634\u2013641","journal-title":"AJR Am J Roentgenol"},{"issue":"5","key":"8947_CR15","doi-asserted-by":"publisher","first-page":"2571","DOI":"10.1007\/s00330-019-06599-6","volume":"30","author":"L Lunden","year":"2020","unstructured":"Lunden L, Wolff S, S\u00f6nke P et al (2020) MRI in patients with implanted active devices: how to combine safety and image quality using a limited transmission field? Eur Radiol 30(5):2571\u20132582","journal-title":"Eur Radiol"},{"issue":"4","key":"8947_CR16","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.acra.2019.07.002","volume":"27","author":"L Ruiz-Flores","year":"2020","unstructured":"Ruiz-Flores L, Whitman GJ, Carissa Le-Petross HT, Hess KR, Parikh JR (2020) Variation in Technical Quality of Breast MRI. Acad Radiol 27(4):468\u2013475","journal-title":"Acad Radiol"},{"issue":"1","key":"8947_CR17","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1148\/radiology.184.1.1609100","volume":"184","author":"MN Linver","year":"1992","unstructured":"Linver MN, Paster SB, Rosenberg RD, Key CR, Stidley CA, King WV (1992) Improvement in mammography interpretation skills in a community radiology practice after dedicated teaching courses: 2-year medical audit of 38,633 cases. Radiology 184(1):39\u201343","journal-title":"Radiology"},{"issue":"1","key":"8947_CR18","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.eururo.2018.09.033","volume":"75","author":"V Kasivisvanathan","year":"2019","unstructured":"Kasivisvanathan V, Ambrosi A, Giganti F et al (2019) A dedicated prostate MRI teaching course improves the ability of the urologist to interpret clinically significant prostate cancer on multiparametric MRI. Eur Urol 75(1):203\u2013204","journal-title":"Eur Urol"},{"issue":"6","key":"8947_CR19","doi-asserted-by":"publisher","first-page":"4386","DOI":"10.1007\/s00330-020-07527-9","volume":"31","author":"AR Padhani","year":"2021","unstructured":"Padhani AR, Schoots I, Turkbey B, Giannarini G, Barentsz JO (2021) A multifaceted approach to quality in the MRI-directed biopsy pathway for prostate cancer diagnosis. Eur Radiol 31(6):4386\u20134389","journal-title":"Eur Radiol"},{"key":"8947_CR20","doi-asserted-by":"publisher","first-page":"110145","DOI":"10.1016\/j.ejrad.2021.110145","volume":"147","author":"MA Arnoldner","year":"2022","unstructured":"Arnoldner MA, Polanec SH, Lazar M et al (2022) Rectal preparation significantly improves prostate imaging quality: assessment of the PI-QUAL score with visual grading characteristics. Eur J Radiol 147:110145","journal-title":"Eur J Radiol"},{"key":"8947_CR21","doi-asserted-by":"publisher","first-page":"109949","DOI":"10.1016\/j.ejrad.2021.109949","volume":"144","author":"M Boschheidgen","year":"2021","unstructured":"Boschheidgen M, Ullrich T, Blondin D et al (2021) Comparison and prediction of artefact severity due to total hip replacement in 1.5T versus 3T MRI of the prostate. Eur J Radiol 144:109949","journal-title":"Eur J Radiol"},{"issue":"2","key":"8947_CR22","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1007\/s00330-021-08169-1","volume":"32","author":"F Giganti","year":"2022","unstructured":"Giganti F, Dinneen E, Kasivisvanathan V et al (2022) Inter-reader agreement of the PI-QUAL score for prostate MRI quality in the NeuroSAFE PROOF trial. Eur Radiol 32(2):879\u2013889","journal-title":"Eur Radiol"},{"issue":"2","key":"8947_CR23","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1007\/s00330-021-08399-3","volume":"32","author":"M De Rooij","year":"2022","unstructured":"De Rooij M, Barentsz JO (2022) PI-QUAL v. 1: the first step towards good-quality prostate MRI. Eur Radiol 32(2):876\u2013878","journal-title":"Eur Radiol"},{"key":"8947_CR24","doi-asserted-by":"publisher","unstructured":"Turkbey B (2022) Better image quality for diffusion-weighted MRI of the prostate using deep learning. Radiology 303(2):382\u2013383. https:\/\/doi.org\/10.1148\/radiol.212078","DOI":"10.1148\/radiol.212078"},{"issue":"5","key":"8947_CR25","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/j.euo.2020.07.003","volume":"3","author":"B Turkbey","year":"2020","unstructured":"Turkbey B, Choyke PL (2020) PI-QUAL, a new system for evaluating prostate magnetic resonance imaging quality: is beauty in the eye of the beholder? Eur Urol Oncol 3(5):620\u2013621","journal-title":"Eur Urol Oncol"},{"issue":"4","key":"8947_CR26","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.eururo.2020.09.015","volume":"79","author":"G Giannarini","year":"2021","unstructured":"Giannarini G, Valotto C, Girometti R, Dal Moro F, Briganti A, Padhani AR (2021) Measuring the quality of diagnostic prostate magnetic resonance imaging: a urologist\u2019s perspective. Eur Urol 79(4):440\u2013441","journal-title":"Eur Urol"},{"key":"8947_CR27","doi-asserted-by":"publisher","unstructured":"Girometti R, Blandino A, Zichichi C et al (2022) Inter-reader agreement of the Prostate Imaging Quality (PI-QUAL) score: a bicentric study. Eur J Radiol 150:110267. https:\/\/doi.org\/10.1016\/j.ejrad.2022.110267","DOI":"10.1016\/j.ejrad.2022.110267"},{"key":"8947_CR28","doi-asserted-by":"publisher","unstructured":"Giganti F, Aupin L, Thoumin C et al (2022) Promoting the use of the PRECISE score for prostate MRI during active surveillance: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship. Insights Imaging. https:\/\/doi.org\/10.1186\/s13244-022-01252-1","DOI":"10.1186\/s13244-022-01252-1"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-08947-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-022-08947-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-08947-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,15]],"date-time":"2022-12-15T12:10:55Z","timestamp":1671106255000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-022-08947-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,30]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["8947"],"URL":"https:\/\/doi.org\/10.1007\/s00330-022-08947-5","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,30]]},"assertion":[{"value":"25 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Dr. Francesco Giganti.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies:FG is a recipient of the 2020 Young Investigator Award (20YOUN15) funded by the Prostate Cancer Foundation \/ CRIS Cancer Foundation. FG has been the recipient of the 2021 ESOR Nicholas Gourtsoyiannis teaching fellowship.APC is supported by Pfizer and the American Cancer Society.LGB reports consulting fees from Delfina outside of the submitted work and research funding from the Office of Scholarly Engagement at Harvard Medical School.VK is an Academic Clinical Lecturer funded by the UK National Institute for Health Research (NIHR).AK is supported by the UCLH\/UCL Biomedical Research Centre.ME receives research support from the United kingdom\u2019s National Institute of Health Research (NIHR) UCLH and UCL Biomedical Research Centre.CMM is supported by the UKNIHR, Movember, PCUK, and the EAU Research Foundation.CMT receives NIH research funding (EB 028741 and\u00a0EB 025823) and is a medical advisor for\u00a0Profound Medical, Medscape and Promaxo.\u00a0","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors (AA) has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"All patients gave written informed consent.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"All patients included in this report gave written informed consent to have their images used for research and teaching purposes. No IRB approval was needed for this study.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 retrospective\u2022 experimental\u2022 multi-centre study","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}