{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T13:24:04Z","timestamp":1788009844196,"version":"build-2784847793"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T00:00:00Z","timestamp":1661385600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T00:00:00Z","timestamp":1661385600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-022-09103-9","type":"journal-article","created":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T04:03:36Z","timestamp":1661400216000},"page":"936-946","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Super-resolution application of generative adversarial network on brain time-of-flight MR angiography: image quality and diagnostic utility evaluation"],"prefix":"10.1007","volume":"33","author":[{"given":"Krishna Pandu","family":"Wicaksono","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1209-7949","authenticated-orcid":false,"given":"Koji","family":"Fujimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasutaka","family":"Fushimi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiko","family":"Sakata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sachi","family":"Okuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Hinoda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukihiro","family":"Yamao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazumichi","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanae Kawai","family":"Miyake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hitomi","family":"Numamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsuneo","family":"Saga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuji","family":"Nakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,25]]},"reference":[{"key":"9103_CR1","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1002\/mrm.1910140206","volume":"14","author":"DG Nishimura","year":"1990","unstructured":"Nishimura DG (1990) Time-of-flight MR angiography. Magn Reson Med 14:194\u2013201","journal-title":"Magn Reson Med"},{"key":"9103_CR2","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.clinimag.2017.10.012","volume":"49","author":"R Yan","year":"2018","unstructured":"Yan R, Zhang B, Wang L et al (2018) A comparison of contrast-free MRA at 3.0T in cases of intracranial aneurysms with or without subarachnoid hemorrhage. Clin Imaging 49:131\u2013135","journal-title":"Clin Imaging"},{"key":"9103_CR3","doi-asserted-by":"publisher","first-page":"3059","DOI":"10.1007\/s00330-020-06682-3","volume":"30","author":"X Zhang","year":"2020","unstructured":"Zhang X, Cao YZ, Mu XH et al (2020) Highly accelerated compressed sensing time-of-flight magnetic resonance angiography may be reliable for diagnosing head and neck arterial steno-occlusive disease: a comparative study with digital subtraction angiography. Eur Radiol 30:3059\u20133065","journal-title":"Eur Radiol"},{"key":"9103_CR4","doi-asserted-by":"crossref","unstructured":"Dong C, Loy CC, He K, Tang X (2014) Learning a Deep Convolutional Network for Image Super-Resolution. In: Computer Vision \u2013 ECCV 2014. Springer International Publishing, pp 184\u2013199","DOI":"10.1007\/978-3-319-10593-2_13"},{"key":"9103_CR5","doi-asserted-by":"crossref","unstructured":"Kim J, Lee JK, Lee KM (2016) Deeply-recursive convolutional network for image super-resolution. In: 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, pp 1637\u20131645","DOI":"10.1109\/CVPR.2016.181"},{"key":"9103_CR6","doi-asserted-by":"crossref","unstructured":"Lai W-S, Huang J-B, Ahuja N, Yang M-H (2017) Deep Laplacian pyramid networks for fast and accurate super-resolution. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, pp 5835\u20135843","DOI":"10.1109\/CVPR.2017.618"},{"key":"9103_CR7","doi-asserted-by":"crossref","unstructured":"Lim B, Son S, Kim H, et al (2017) Enhanced deep residual networks for single image super-resolution. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition Workshops (CVPRW). IEEE, pp 1132\u20131140","DOI":"10.1109\/CVPRW.2017.151"},{"key":"9103_CR8","doi-asserted-by":"publisher","unstructured":"Goodfellow IJ, Pouget-Abadie J, Mirza M et al (2014) Generative adversarial networks. arXiv:1406.2661 [stat.ML]. https:\/\/doi.org\/10.48550\/arXiv.1406.2661","DOI":"10.48550\/arXiv.1406.2661"},{"key":"9103_CR9","doi-asserted-by":"crossref","unstructured":"Ledig C, Theis L, Husz\u00e1r F et al (2017) Photo-realistic single image super-resolution using a generative adversarial network. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, pp 105\u2013114","DOI":"10.1109\/CVPR.2017.19"},{"key":"9103_CR10","doi-asserted-by":"publisher","first-page":"21815","DOI":"10.1007\/s11042-020-08980-w","volume":"79","author":"Y Gu","year":"2020","unstructured":"Gu Y, Zeng Z, Chen H et al (2020) MedSRGAN: medical images super-resolution using generative adversarial networks. Multimed Tools Appl 79:21815\u201321840","journal-title":"Multimed Tools Appl"},{"key":"9103_CR11","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s12194-019-00520-y","volume":"12","author":"S Kaji","year":"2019","unstructured":"Kaji S, Kida S (2019) Overview of image-to-image translation by use of deep neural networks: denoising, super-resolution, modality conversion, and reconstruction in medical imaging. Radiol Phys Technol 12:235\u2013248","journal-title":"Radiol Phys Technol"},{"key":"9103_CR12","doi-asserted-by":"crossref","unstructured":"Tan C, Zhu J, Lio\u2019 P (2020) Arbitrary scale super-resolution for brain MRI images. Artificial Intelligence Applications and Innovations 583:165","DOI":"10.1007\/978-3-030-49161-1_15"},{"key":"9103_CR13","doi-asserted-by":"publisher","unstructured":"Zhang H, Shinomiya Y, Yoshida S (2021) 3D MRI reconstruction based on 2D generative adversarial network super-resolution. Sensors 21. https:\/\/doi.org\/10.3390\/s21092978","DOI":"10.3390\/s21092978"},{"key":"9103_CR14","doi-asserted-by":"publisher","unstructured":"Sanchez I, Vilaplana V (2018) Brain MRI super-resolution using 3D generative adversarial networks. arXiv:1812.11440 [cs.CV]. https:\/\/doi.org\/10.48550\/arXiv.1812.11440","DOI":"10.48550\/arXiv.1812.11440"},{"key":"9103_CR15","doi-asserted-by":"crossref","unstructured":"Isola P, Zhu J-Y, Zhou T, Efros AA (2017) Image-to-image translation with conditional adversarial networks. In: Proceedings of the IEEE conference on computer vision and pattern recognition. pp 1125\u20131134","DOI":"10.1109\/CVPR.2017.632"},{"key":"9103_CR16","unstructured":"Wang Z, Simoncelli EP, Bovik A (2003) Multi-scale structural similarity for image quality assessment. In: The Thrity-Seventh Asilomar Conference on Signals, Systems & Computers. IEEE, pp 1398\u20131402"},{"key":"9103_CR17","unstructured":"Loizides F, Schmidt B (2016) Positioning and power in academic publishing: players, agents and agendas: Proceedings of the 20th International Conference on Electronic Publishing. IOS Press"},{"key":"9103_CR18","unstructured":"Chollet F (2015) Keras. In: GitHub. https:\/\/github.com\/fchollet\/keras"},{"key":"9103_CR19","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1080\/22797254.2019.1628617","volume":"52","author":"MA Aljanabi","year":"2019","unstructured":"Aljanabi MA, Hussain ZM, Shnain NAA, Lu SF (2019) Design of a hybrid measure for image similarity: a statistical, algebraic, and information-theoretic approach. Eur J Remote Sens 52:2\u201315","journal-title":"Eur J Remote Sens"},{"key":"9103_CR20","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1109\/TMI.2019.2930338","volume":"39","author":"A Mason","year":"2020","unstructured":"Mason A, Rioux J, Clarke SE et al (2020) Comparison of objective image quality metrics to expert radiologists\u2019 scoring of diagnostic quality of MR images. IEEE Trans Med Imaging 39:1064\u20131072","journal-title":"IEEE Trans Med Imaging"},{"key":"9103_CR21","doi-asserted-by":"publisher","first-page":"211301","DOI":"10.1007\/s11432-019-2757-1","volume":"63","author":"G Zhai","year":"2020","unstructured":"Zhai G, Min X (2020) Perceptual image quality assessment: a survey. Sci China Inf Sci 63:211301","journal-title":"Sci China Inf Sci"},{"key":"9103_CR22","doi-asserted-by":"publisher","first-page":"3312","DOI":"10.1109\/TIP.2019.2895768","volume":"28","author":"A Lucas","year":"2019","unstructured":"Lucas A, Lopez-Tapia S, Molina R, Katsaggelos AK (2019) Generative adversarial networks and perceptual losses for video super-resolution. IEEE Trans Image Process 28:3312\u20133327","journal-title":"IEEE Trans Image Process"},{"key":"9103_CR23","doi-asserted-by":"crossref","unstructured":"Ahn N, Kang B, Sohn K-A (2018) Fast, accurate, and lightweight super-resolution with cascading residual network. In: Proceedings of the European Conference on Computer Vision (ECCV), pp 252\u2013268","DOI":"10.1109\/CVPRW.2018.00123"},{"key":"9103_CR24","unstructured":"Wang Z, Simoncelli EP, Bovik A (2003) Multi-scale structural similarity for image quality assessment. In: The Thrity-Seventh Asilomar Conference on Signals, Systems & Computers. IEEE, pp 1398\u20131402"},{"key":"9103_CR25","doi-asserted-by":"crossref","unstructured":"Snell J, Ridgeway K, Liao R, et al (2017) Learning to generate images with perceptual similarity metrics. In: 2017 IEEE International Conference on Image Processing (ICIP), pp 4277\u20134281","DOI":"10.1109\/ICIP.2017.8297089"},{"key":"9103_CR26","doi-asserted-by":"publisher","unstructured":"Zhao H, Gallo O, Frosio I, Kautz J (2015) Loss Functions for Neural Networks for Image Processing. arXiv:1511.08861 [cs.CV]. https:\/\/doi.org\/10.48550\/arXiv.1511.08861","DOI":"10.48550\/arXiv.1511.08861"},{"key":"9103_CR27","doi-asserted-by":"crossref","unstructured":"Wang J, Chen Y, Wu Y, et al (2020) Enhanced generative adversarial network for 3D brain MRI super-resolution. In: 2020 IEEE Winter Conference on Applications of Computer Vision (WACV), pp 3616\u20133625","DOI":"10.1109\/WACV45572.2020.9093603"},{"key":"9103_CR28","first-page":"106","volume":"2021","author":"H Do","year":"2021","unstructured":"Do H, Bourdon P, Helbert D et al (2021) 7T MRI super-resolution with generative adversarial network. IS&T Int Symp Electron Imaging 2021:106\u2013106","journal-title":"IS&T Int Symp Electron Imaging"},{"key":"9103_CR29","doi-asserted-by":"publisher","first-page":"224","DOI":"10.3174\/ajnr.A5927","volume":"40","author":"A Hagiwara","year":"2019","unstructured":"Hagiwara A, Otsuka Y, Hori M et al (2019) Improving the quality of synthetic FLAIR images with deep learning using a conditional generative adversarial network for pixel-by-pixel image translation. AJNR Am J Neuroradiol 40:224\u2013230","journal-title":"AJNR Am J Neuroradiol"},{"key":"9103_CR30","doi-asserted-by":"publisher","first-page":"2837","DOI":"10.1002\/mrm.28911","volume":"86","author":"T K\u00fcstner","year":"2021","unstructured":"K\u00fcstner T, Munoz C, Psenicny A et al (2021) Deep-learning based super-resolution for 3D isotropic coronary MR angiography in less than a minute. Magn Reson Med 86:2837\u20132852","journal-title":"Magn Reson Med"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-09103-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-022-09103-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-09103-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T04:16:51Z","timestamp":1675138611000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-022-09103-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,25]]},"references-count":30,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["9103"],"URL":"https:\/\/doi.org\/10.1007\/s00330-022-09103-9","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,25]]},"assertion":[{"value":"18 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Koji Fujimoto.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"Four authors (Koji Fujimoto, Kanae Kawai Miyake, Hitomi Numamoto, and Tsuneo Saga) belong to an Industry-Academia collaboration department. Conflicts of interest for each author will be submitted to the editorial office.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Since this was a retrospective study, written informed consent was waived from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 retrospective\u2022 cross-sectional study\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}