{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T11:56:00Z","timestamp":1771329360452,"version":"3.50.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,11,30]],"date-time":"2022-11-30T00:00:00Z","timestamp":1669766400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,11,30]],"date-time":"2022-11-30T00:00:00Z","timestamp":1669766400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"National Key Project of the 13th Five-Year Plan of China","award":["2016YFC1300400"],"award-info":[{"award-number":["2016YFC1300400"]}]},{"name":"Scientific and Technological Project of Inner Mongolia Autonomous Region of China","award":["201702102"],"award-info":[{"award-number":["201702102"]}]},{"name":"Natural Science Foundation of Inner Mongolia Autonomous Region of China","award":["2021MS08005"],"award-info":[{"award-number":["2021MS08005"]}]},{"name":"Natural Science Foundation of Inner Mongolia Autonomous Region of China","award":["2020MS08066"],"award-info":[{"award-number":["2020MS08066"]}]},{"name":"Inner Mongolia Autonomous Region Higher Education Research Fund Project","award":["NJZY21082"],"award-info":[{"award-number":["NJZY21082"]}]},{"name":"Scientific and Technological Project of Baotou of China","award":["2018C2007-2-2"],"award-info":[{"award-number":["2018C2007-2-2"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-022-09286-1","type":"journal-article","created":{"date-parts":[[2022,11,30]],"date-time":"2022-11-30T08:04:40Z","timestamp":1669795480000},"page":"3819-3831","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of myocardial viability in patients with myocardial ischemia reperfusion injury using the dual-energy CT myocardial blood pool imaging"],"prefix":"10.1007","volume":"33","author":[{"given":"Qingyu","family":"Ji","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingwei","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanfeng","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maorong","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baoliang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruijuan","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7963-9936","authenticated-orcid":false,"given":"Kai","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,30]]},"reference":[{"issue":"11","key":"9286_CR1","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.jacc.2011.07.054","volume":"59","author":"PZ Gerczuk","year":"2012","unstructured":"Gerczuk PZ, Kloner RA (2012) An update on cardioprotection: a review of the latest adjunctive therapies to limit myocardial infarction size in clinical trials. J Am Coll Cardiol 59(11):969\u2013978","journal-title":"J Am Coll Cardiol"},{"key":"9286_CR2","first-page":"68","volume":"70","author":"RB Jennings","year":"1960","unstructured":"Jennings RB, Sommers HM, Smyth GA, Flack HA, Linn H (1960) Myocardial necrosis induced by temporary occlusion of a coronary artery in the dog. Arch Pathol 70:68\u201378","journal-title":"Arch Pathol"},{"issue":"14","key":"9286_CR3","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.4244\/EIJY19M01_01","volume":"14","author":"FJ Neumann","year":"2019","unstructured":"Neumann FJ, Sousa-Uva M, Ahlsson A et al (2019) 2018 ESC\/EACTS Guidelines on myocardial revascularization. EuroIntervention 14(14):1435\u20131534","journal-title":"EuroIntervention"},{"key":"9286_CR4","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.ejrad.2019.01.017","volume":"112","author":"B Mvaa","year":"2019","unstructured":"Mvaa B, Fla C, Ujs A et al (2019) Iodine quantification based on rest \/ stress perfusion dual energy CT to differentiate ischemic, infarcted and normal myocardium. Eur J Radiol 112:136\u2013143","journal-title":"Eur J Radiol"},{"key":"9286_CR5","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1161\/CIRCULATIONAHA.105.521450","volume":"113","author":"AC Lardo","year":"2006","unstructured":"Lardo AC, Cordeiro M, Silva C et al (2006) Contrast enhanced multidetector computed tomography viability imaging after myocardial infarction: characterization of myocyte death, microvascular obstruction, and chronic scar. Circulation 113:394\u2013404","journal-title":"Circulation"},{"issue":"9","key":"9286_CR6","doi-asserted-by":"publisher","first-page":"3904","DOI":"10.1007\/s00330-017-4752-9","volume":"27","author":"GJ Pelgrim","year":"2017","unstructured":"Pelgrim GJ, Hamersvelt RV, Willemink MJ et al (2017) Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT. Eur Radiol 27(9):3904\u20133912","journal-title":"Eur Radiol"},{"key":"9286_CR7","doi-asserted-by":"publisher","first-page":"1914","DOI":"10.1016\/j.ejrad.2016.06.023","volume":"85","author":"KN Jin","year":"2016","unstructured":"Jin KN, Cecco CD, Caruso D et al (2016) Myocardial perfusion imaging with dual energy CT. Eur J Radiol 85:1914\u20131921","journal-title":"Eur J Radiol"},{"issue":"2","key":"9286_CR8","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1007\/s00330-013-3040-6","volume":"24","author":"JD Koonce","year":"2016","unstructured":"Koonce JD, Vliegenthart R, Schoepf UJ et al (2016) Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model. Eur Radiol 24(2):512\u2013518","journal-title":"Eur Radiol"},{"key":"9286_CR9","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1148\/radiol.13131183","volume":"270","author":"FG Meinel","year":"2014","unstructured":"Meinel FG, De Cecco CN, Schoepf UJ et al (2014) First-arterial-pass dual-energy CT for assessment of myocardial blood supply: do we need rest, stress, and delayed acquisition? Comparison with SPECT. Radiology 270:708\u2013716","journal-title":"Radiology"},{"issue":"2","key":"9286_CR10","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1097\/RTI.0000000000000284","volume":"33","author":"T Nakahara","year":"2017","unstructured":"Nakahara T, Toyama T, Jinzaki M et al (2017) Quantitative analysis of iodine image of dual-energy computed tomography at rest: comparison with 99mTc-tetrofosmin stress-rest single-photon emission computed tomography myocardial perfusion imaging as the reference standard. J Thorac Imaging 33(2):97\u2013104","journal-title":"J Thorac Imaging"},{"issue":"7","key":"9286_CR11","volume":"13","author":"MJ Garcia","year":"2020","unstructured":"Garcia MJ, Kwong RY, Scherrer-Crosbie M et al (2020) American Heart Association Council on Cardiovascular Radiology and Intervention and Council on Clinical Cardiology. State of the art: imaging for myocardial viability: a scientific statement from the American Heart Association. Circ Cardiovasc Imaging 13(7):e000053","journal-title":"Imaging"},{"key":"9286_CR12","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1161\/hc0402.102975","volume":"105","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539\u2013542","journal-title":"Circulation"},{"key":"9286_CR13","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/j.jcmg.2017.06.006","volume":"11","author":"S Trattner","year":"2017","unstructured":"Trattner S, Halliburton S, Thompson CM et al (2017) Cardiac-specific conversion factors to estimate radiation effective dose from dose-length product in computed tomography. JACC Cardiovasc Imaging 11:64\u201374","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"9286_CR14","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1097\/HP.0b013e3182751a99","volume":"104","author":"EL Wilds","year":"2013","unstructured":"Wilds EL (2013) Radiation protection and safety of radiation sources: international; basic safety standards-interim edition, general safety requirements Part;3 No. GSR Part 3 (Interim)[J]. Health Phys 104(2):232\u2013233","journal-title":"Health Phys"},{"key":"9286_CR15","doi-asserted-by":"publisher","first-page":"2172","DOI":"10.1161\/01.CIR.0000128862.34201.74","volume":"109","author":"E Wellnhofer","year":"2004","unstructured":"Wellnhofer E, Olariu A, Klein C et al (2004) Magnetic resonance low-dose dobutamine test is superior to SCAR quantification for the prediction of functional recovery. Circulation 109:2172\u20132174","journal-title":"Circulation"},{"key":"9286_CR16","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/S1064-9689(02)00048-X","volume":"11","author":"A Wagner","year":"2003","unstructured":"Wagner A, Mahrholdt H, Sechtem U et al (2003) MR imaging of myocardial perfusion and viability. Magn Reson Imaging Clin N Am 11:49\u201366","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"9286_CR17","doi-asserted-by":"crossref","unstructured":"Kellman P, Hui X, Olivieri LJ et al (2017) Dark blood late enhancement imaging. J Cardiovasc Magn Reson 18:77","DOI":"10.1186\/s12968-016-0297-3"},{"key":"9286_CR18","doi-asserted-by":"publisher","first-page":"1949","DOI":"10.1007\/s10554-017-1189-9","volume":"33","author":"L Yin","year":"2017","unstructured":"Yin L, Xu HY, Zheng SS et al (2017) 3.0 T magnetic resonance myocardial perfusion imaging for semi-quantitative evaluation of coronary microvascular dysfunction in hypertrophic cardiomyopathy. Int J Cardiovasc Imaging 33:1949\u20131959","journal-title":"Int J Cardiovasc Imaging"},{"key":"9286_CR19","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1253\/circj.CJ-08-0940","volume":"73","author":"M Nagao","year":"2009","unstructured":"Nagao M, Matsuoka H, Kawakami H et al (2009) Detection of myocardial ischemia using 64-slice MDCT. Circ J 73:905\u2013911","journal-title":"Circ J"},{"key":"9286_CR20","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1053\/j.sult.2010.05.004","volume":"31","author":"DK Kang","year":"2010","unstructured":"Kang DK, Schoepf UJ, Bastarrika G et al (2010) Dual-energy computed tomography for integrative imaging of coronary artery disease: principles and clinical applications. Semin Ultrasound CT MR 31:276\u2013291","journal-title":"Semin Ultrasound CT MR"},{"key":"9286_CR21","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1097\/MCA.0b013e32835f2fe5","volume":"24","author":"M Gupta","year":"2013","unstructured":"Gupta M, Kadakia J, Jug B, Mao SS, Budoff MJ (2013) Detection and quantification of myocardial perfusion defects by resting single-phase 64-slice cardiac computed tomography angiography compared with SPECT myocardial perfusion imaging. Coron Artery Dis 24:290\u2013297","journal-title":"Coron Artery Dis"},{"key":"9286_CR22","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1007\/s00330-010-1897-1","volume":"21","author":"SM Ko","year":"2011","unstructured":"Ko SM, Choi JW, Song MG et al (2011) Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography. Eur Radiol 21:26\u201335","journal-title":"Eur Radiol"},{"issue":"2","key":"9286_CR23","first-page":"A5437","volume":"65","author":"PH Johnsen","year":"2018","unstructured":"Johnsen PH, Johansen MB, Jensen SE (2018) Long-term outcome after normal myocardial perfusion imaging in suspected ischaemic heart disease. Dan Med J 65(2):A5437","journal-title":"Dan Med J"},{"key":"9286_CR24","doi-asserted-by":"crossref","unstructured":"Nakahara T, Toyama T, Jinzaki M et al (2017) Quantitative analysis of iodine image of dual-energy computed tomography at rest: comparison with 99mTc-tetrofosmin stress-rest single-photon emission computed tomography myocardial perfusion imaging as the reference standard[J]. J Thorac Imaging 1","DOI":"10.1097\/RTI.0000000000000284"},{"key":"9286_CR25","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1177\/0284185114527867","volume":"56","author":"F Secchi","year":"2015","unstructured":"Secchi F, De Cecco CN, Spearman JV et al (2015) Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction. Acta Radiol 56:413\u2013418","journal-title":"Acta Radiol"},{"key":"9286_CR26","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/S0940-9602(00)80102-8","volume":"182","author":"M Koizumi","year":"2000","unstructured":"Koizumi M, Kawai K, Honma S, Kodama K (2000) Anatomical study of a left single coronary artery with special reference to the various distribution patterns of bilateral coronary arteries. Ann Anat 182:549\u2013557","journal-title":"Ann Anat"},{"key":"9286_CR27","doi-asserted-by":"publisher","first-page":"512","DOI":"10.2214\/AJR.11.7029","volume":"198","author":"SM Ko","year":"2012","unstructured":"Ko SM, Choi JW, Hwang HK et al (2012) Diagnostic performance of combined noninvasive anatomic and functional assessment with dual-source CT and adenosine-induced stress dual-energy CT for detection of significant coronary stenosis. AJR Am J Roentgenol 198:512\u2013520","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"9286_CR28","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s41747-020-00158-1","volume":"4","author":"MV Assen","year":"2020","unstructured":"Assen MV, Vonder M, Pelgrim GJ, Von Knebel Doeberitz PL, Vliegenthart R (2020) Computed tomography for myocardial characterization in ischemic heart disease: a state-of-the-art review. Eur Radiol Exp 4(1):36","journal-title":"Eur Radiol Exp"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-09286-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-022-09286-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-022-09286-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,12]],"date-time":"2023-05-12T12:06:46Z","timestamp":1683893206000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-022-09286-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,30]]},"references-count":28,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["9286"],"URL":"https:\/\/doi.org\/10.1007\/s00330-022-09286-1","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,30]]},"assertion":[{"value":"20 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 November 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Kai Sun.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"All procedures were in accordance with the Helsinki declaration. All patients gave their written informed consent to participate in the study. The data do not contain any information that could identify patients.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The clinical study was approved by the ethics committees of Inner Mongolia Medical University of China) (No. YKD2015061).","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 observational\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}