{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:47:14Z","timestamp":1787842034578,"version":"build-2784847793"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T00:00:00Z","timestamp":1681689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T00:00:00Z","timestamp":1681689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"the Capital Medical University","award":["PYZ20092"],"award-info":[{"award-number":["PYZ20092"]}]},{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82001804"],"award-info":[{"award-number":["82001804"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81961128030"],"award-info":[{"award-number":["81961128030"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-023-09629-6","type":"journal-article","created":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T02:01:55Z","timestamp":1681696915000},"page":"6939-6947","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Improved characterization of lenticulostriate arteries using compressed sensing time-of-flight at 7T"],"prefix":"10.1007","volume":"33","author":[{"given":"Zhe","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingle","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingkui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanlin","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuyuan","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Suo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xia","family":"Meng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Liebig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zihao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongjun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9822-5758","authenticated-orcid":false,"given":"Jing","family":"Jing","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,17]]},"reference":[{"key":"9629_CR1","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1001\/archneur.1990.00530100063014","volume":"47","author":"JA Ghika","year":"1990","unstructured":"Ghika JA, Bogousslavsky J, Regli F (1990) Deep perforators from the carotid system: template of the vascular territories. Arch Neurol 47:1097\u20131100. https:\/\/doi.org\/10.1001\/archneur.1990.00530100063014","journal-title":"Arch Neurol"},{"key":"9629_CR2","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1007\/s00701-015-2378-8","volume":"157","author":"V Djuleji\u0107","year":"2015","unstructured":"Djuleji\u0107 V, Marinkovi\u0107 S, Mili\u0107 V et al (2015) Common features of the cerebral perforating arteries and their clinical significance. Acta Neurochir (Wien) 157:743\u2013754. https:\/\/doi.org\/10.1007\/s00701-015-2378-8","journal-title":"Acta Neurochir (Wien)"},{"key":"9629_CR3","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/S1474-4422(13)70310-7","volume":"13","author":"RG Hart","year":"2014","unstructured":"Hart RG, Diener H-C, Coutts SB et al (2014) Embolic strokes of undetermined source: the case for a new clinical construct. Lancet Neurol 13:429\u2013438. https:\/\/doi.org\/10.1016\/S1474-4422(13)70310-7","journal-title":"Lancet Neurol"},{"key":"9629_CR4","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1002\/mrm.21786","volume":"61","author":"C-K Kang","year":"2009","unstructured":"Kang C-K, Park C-W, Han J-Y et al (2009) Imaging and analysis of lenticulostriate arteries using 7.0-Tesla magnetic resonance angiography. Magn Reson Med 61:136\u2013144. https:\/\/doi.org\/10.1002\/mrm.21786","journal-title":"Magn Reson Med"},{"key":"9629_CR5","doi-asserted-by":"publisher","first-page":"1604","DOI":"10.1161\/STROKEAHA.107.508002","volume":"39","author":"Z-H Cho","year":"2008","unstructured":"Cho Z-H, Kang C-K, Han J-Y et al (2008) Observation of the lenticulostriate arteries in the human brain in vivo using 7.0T MR angiography. Stroke 39:1604\u20131606. https:\/\/doi.org\/10.1161\/STROKEAHA.107.508002","journal-title":"Stroke"},{"key":"9629_CR6","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.ejrad.2019.07.032","volume":"118","author":"Q Kong","year":"2019","unstructured":"Kong Q, Zhang Z, Yang Q et al (2019) 7T TOF-MRA shows modulated orifices of lenticulostriate arteries associated with atherosclerotic plaques in patients with lacunar infarcts. Eur J Radiol 118:271\u2013276. https:\/\/doi.org\/10.1016\/j.ejrad.2019.07.032","journal-title":"Eur J Radiol"},{"key":"9629_CR7","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1002\/jmri.21097","volume":"26","author":"C von Morze","year":"2007","unstructured":"von Morze C, Xu D, Purcell DD et al (2007) Intracranial time-of-flight MR angiography at 7T with comparison to 3T. J Magn Reson Imaging 26:900\u2013904. https:\/\/doi.org\/10.1002\/jmri.21097","journal-title":"J Magn Reson Imaging"},{"key":"9629_CR8","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1111\/j.1747-4949.2010.00464.x","volume":"5","author":"C-K Kang","year":"2010","unstructured":"Kang C-K, Park C-A, Park C-W et al (2010) Lenticulostriate arteries in chronic stroke patients visualised by 7 T magnetic resonance angiography. Int J Stroke 5:374\u2013380. https:\/\/doi.org\/10.1111\/j.1747-4949.2010.00464.x","journal-title":"Int J Stroke"},{"key":"9629_CR9","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1161\/HYPERTENSIONAHA.109.140350","volume":"54","author":"C-K Kang","year":"2009","unstructured":"Kang C-K, Park C-A, Lee H et al (2009) Hypertension correlates with lenticulostriate arteries visualized by 7T magnetic resonance angiography. Hypertension 54:1050\u20131056. https:\/\/doi.org\/10.1161\/HYPERTENSIONAHA.109.140350","journal-title":"Hypertension"},{"key":"9629_CR10","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.jns.2012.05.032","volume":"322","author":"SW Seo","year":"2012","unstructured":"Seo SW, Kang C-K, Kim SH et al (2012) Measurements of lenticulostriate arteries using 7T MRI: new imaging markers for subcortical vascular dementia. J Neurol Sci 322:200\u2013205. https:\/\/doi.org\/10.1016\/j.jns.2012.05.032","journal-title":"J Neurol Sci"},{"key":"9629_CR11","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1007\/s00330-018-5701-y","volume":"29","author":"Z Zhang","year":"2019","unstructured":"Zhang Z, Fan Z, Kong Q et al (2019) Visualization of the lenticulostriate arteries at 3T using black-blood T1-weighted intracranial vessel wall imaging: comparison with 7T TOF-MRA. Eur Radiol 29:1452\u20131459. https:\/\/doi.org\/10.1007\/s00330-018-5701-y","journal-title":"Eur Radiol"},{"key":"9629_CR12","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1002\/mrm.27033","volume":"80","author":"H Mattern","year":"2018","unstructured":"Mattern H, Sciarra A, Godenschweger F et al (2018) Prospective motion correction enables highest resolution time-of-flight angiography at 7T: prospectively motion-corrected TOF angiography at 7T. Magn Reson Med 80:248\u2013258. https:\/\/doi.org\/10.1002\/mrm.27033","journal-title":"Magn Reson Med"},{"key":"9629_CR13","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202\u20131210. https:\/\/doi.org\/10.1002\/mrm.10171","journal-title":"Magn Reson Med"},{"key":"9629_CR14","doi-asserted-by":"publisher","unstructured":"Blatter DD, Parker DL, Robison RO (1991) Cerebral MR angiography with multiple overlapping thin slab acquisition. Part I. Quantitative analysis of vessel visibility. Radiology 179:805\u2013811. https:\/\/doi.org\/10.1148\/radiology.179.3.2027996","DOI":"10.1148\/radiology.179.3.2027996"},{"key":"9629_CR15","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182\u20131195. https:\/\/doi.org\/10.1002\/mrm.21391","journal-title":"Magn Reson Med"},{"key":"9629_CR16","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1007\/s00723-015-0713-0","volume":"46","author":"C-A Park","year":"2015","unstructured":"Park C-A, Kang D, Son Y-D et al (2015) Microvascular imaging using compressed sensing at 7T MRI: a preliminary study. Appl Magn Reson 46:1189\u20131197. https:\/\/doi.org\/10.1007\/s00723-015-0713-0","journal-title":"Appl Magn Reson"},{"key":"9629_CR17","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.mri.2019.08.014","volume":"63","author":"CR Meixner","year":"2019","unstructured":"Meixner CR, Liebig P, Speier P et al (2019) High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation. Magn Reson Imaging 63:193\u2013204. https:\/\/doi.org\/10.1016\/j.mri.2019.08.014","journal-title":"Magn Reson Imaging"},{"key":"9629_CR18","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1002\/mrm.1910170215","volume":"17","author":"DL Parker","year":"1991","unstructured":"Parker DL, Yuan C, Blatter DD (1991) MR angiography by multiple thin slab 3D acquisition. Magn Reson Med 17:434\u2013451. https:\/\/doi.org\/10.1002\/mrm.1910170215","journal-title":"Magn Reson Med"},{"key":"9629_CR19","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1016\/j.mri.2015.07.002","volume":"33","author":"Z Zhang","year":"2015","unstructured":"Zhang Z, Deng X, Weng D et al (2015) Segmented TOF at 7 T MRI: technique and clinical applications. Magn Reson Imaging 33:1043\u20131050. https:\/\/doi.org\/10.1016\/j.mri.2015.07.002","journal-title":"Magn Reson Imaging"},{"key":"9629_CR20","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1007\/s10439-016-1762-8","volume":"45","author":"A Updegrove","year":"2017","unstructured":"Updegrove A, Wilson NM, Merkow J et al (2017) SimVascular: an open source pipeline for cardiovascular simulation. Ann Biomed Eng 45:525\u2013541. https:\/\/doi.org\/10.1007\/s10439-016-1762-8","journal-title":"Ann Biomed Eng"},{"key":"9629_CR21","doi-asserted-by":"publisher","first-page":"915","DOI":"10.1007\/s10237-011-0361-8","volume":"11","author":"D Sengupta","year":"2012","unstructured":"Sengupta D, Kahn AM, Burns JC et al (2012) Image-based modeling of hemodynamics in coronary artery aneurysms caused by Kawasaki disease. Biomech Model Mechanobiol 11:915\u2013932. https:\/\/doi.org\/10.1007\/s10237-011-0361-8","journal-title":"Biomech Model Mechanobiol"},{"key":"9629_CR22","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1177\/1747493018806163","volume":"14","author":"H Miyazawa","year":"2019","unstructured":"Miyazawa H, Natori T, Kameda H et al (2019) Detecting lenticulostriate artery lesions in patients with acute ischemic stroke using high-resolution MRA at 7 T. Int J Stroke 14:290\u2013297. https:\/\/doi.org\/10.1177\/1747493018806163","journal-title":"Int J Stroke"},{"key":"9629_CR23","doi-asserted-by":"publisher","first-page":"870","DOI":"10.3389\/fneur.2019.00870","volume":"10","author":"C Ling","year":"2019","unstructured":"Ling C, Fang X, Kong Q et al (2019) Lenticulostriate arteries and basal ganglia changes in cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy, a high-field MRI study. Front Neurol 10:870. https:\/\/doi.org\/10.3389\/fneur.2019.00870","journal-title":"Front Neurol"},{"issue":"10","key":"9629_CR24","doi-asserted-by":"publisher","first-page":"e660","DOI":"10.1161\/STROKEAHA.120.034096","volume":"52","author":"V Vogels","year":"2021","unstructured":"Vogels V, Dammers R, van Bilsen M et al (2021) Deep cerebral perforators: anatomical distribution and clinical symptoms: an overview. Stroke 52(10):e660\u2013e674. https:\/\/doi.org\/10.1161\/STROKEAHA.120.034096","journal-title":"Stroke"},{"key":"9629_CR25","doi-asserted-by":"publisher","unstructured":"Harteveld AA, De Cocker LJL, Dieleman N et al (2015) High-resolution postcontrast time-of-flight MR angiography of intracranial perforators at 7.0 Tesla. PLoS One 10:e0121051. https:\/\/doi.org\/10.1371\/journal.pone.0121051","DOI":"10.1371\/journal.pone.0121051"},{"key":"9629_CR26","doi-asserted-by":"publisher","first-page":"2812","DOI":"10.1161\/STROKEAHA.110.586883","volume":"41","author":"MK Liem","year":"2010","unstructured":"Liem MK, van der Grond J, Versluis MJ et al (2010) Lenticulostriate arterial lumina are normal in cerebral autosomal-dominant arteriopathy with subcortical infarcts and leukoencephalopathy: a high-field in vivo MRI study. Stroke 41:2812\u20132816. https:\/\/doi.org\/10.1161\/STROKEAHA.110.586883","journal-title":"Stroke"},{"key":"9629_CR27","doi-asserted-by":"publisher","first-page":"2306","DOI":"10.1109\/TMI.2021.3075856","volume":"40","author":"MJ Muckley","year":"2021","unstructured":"Muckley MJ, Riemenschneider B, Radmanesh A et al (2021) Results of the 2020 fastMRI challenge for machine learning MR image reconstruction. IEEE Trans Med Imaging 40:2306\u20132317. https:\/\/doi.org\/10.1109\/TMI.2021.3075856","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"9629_CR28","first-page":"306","volume":"26","author":"H-S Kang","year":"2005","unstructured":"Kang H-S, Han MH, Kwon BJ et al (2005) Evaluation of the lenticulostriate arteries with rotational angiography and 3D reconstruction. AJNR Am J Neuroradiol 26(2):306\u2013312","journal-title":"AJNR Am J Neuroradiol"},{"key":"9629_CR29","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1161\/01.STR.30.2.317","volume":"30","author":"HJ Cloft","year":"1999","unstructured":"Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis. Stroke 30:317\u2013320. https:\/\/doi.org\/10.1161\/01.STR.30.2.317","journal-title":"Stroke"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09629-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-023-09629-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09629-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,20]],"date-time":"2023-09-20T12:03:35Z","timestamp":1695211415000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-023-09629-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,17]]},"references-count":29,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["9629"],"URL":"https:\/\/doi.org\/10.1007\/s00330-023-09629-6","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,17]]},"assertion":[{"value":"20 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Yongjun Wang.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"Qingle Kong is an employee of Siemens Healthineers Ltd. (Beijing, China). Patrick Liebig is an employee of Siemens Healthcare GmbH (Erlangen, Germany). These authors were not involved in data collection and\/or management in any way that would influence the study (the Tiantan Hospital holds a research agreement with Siemens Healthcare, which provided the CS TOF work-in-progress MRI sequence). The remaining authors declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Anxin Wang (Tiantan Hospital, Capital Medical University, Beijing, China) kindly provided statistical advice for this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board (Ethics Committee of Beijing Tiantan Hospital) approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"\u2022 prospective\u2022 observational\u2022 performed at one institution","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}