{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T13:31:00Z","timestamp":1788442260498,"version":"build-2803163510"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T00:00:00Z","timestamp":1687219200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T00:00:00Z","timestamp":1687219200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Science and Technology Committee of Shanghai Municipality","award":["20DZ2201800"],"award-info":[{"award-number":["20DZ2201800"]}]},{"name":"Clinical Research Plan of SHDC","award":["SHDC2020CR3079B"],"award-info":[{"award-number":["SHDC2020CR3079B"]}]},{"name":"Shanghai Municipal Key Clinical Specialty","award":["shslczdzk03401"],"award-info":[{"award-number":["shslczdzk03401"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-023-09825-4","type":"journal-article","created":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T06:02:01Z","timestamp":1687240921000},"page":"7890-7898","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Head-to-head intra-individual comparison of total-body 2-[18F]FDG PET\/CT and digital PET\/CT in patients with malignant tumor: how sensitive could it be?"],"prefix":"10.1007","volume":"33","author":[{"given":"Xueqi","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pengcheng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haojun","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yibo","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuangliang","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4813-4262","authenticated-orcid":false,"given":"Hongcheng","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,20]]},"reference":[{"key":"9825_CR1","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1016\/j.athoracsur.2004.02.067","volume":"78","author":"RJ Cerfolio","year":"2004","unstructured":"Cerfolio RJ, Ojha B, Bryant AS, Raghuveer V, Mountz JM, Bartolucci AA (2004) The accuracy of integrated PET-CT compared with dedicated PET alone for the staging of patients with nonsmall cell lung cancer. Ann Thorac Surg 78:1017\u20131023","journal-title":"Ann Thorac Surg"},{"key":"9825_CR2","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00259-008-0911-1","volume":"36","author":"M Kleis","year":"2009","unstructured":"Kleis M, Daldrup-Link H, Matthay K et al (2009) Diagnostic value of PET\/CT for the staging and restaging of pediatric tumors. Eur J Nucl Med Mol Imaging 36:23\u201336","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR3","doi-asserted-by":"publisher","first-page":"17s","DOI":"10.2967\/jnumed.115.157859","volume":"57","author":"D Groheux","year":"2016","unstructured":"Groheux D, Cochet A, Humbert O, Alberini JL, Hindi\u00e9 E, Mankoff D (2016) 18F-FDG PET\/CT for staging and restaging of breast cancer. J Nucl Med 57:17s\u201326s","journal-title":"J Nucl Med"},{"key":"9825_CR4","doi-asserted-by":"publisher","DOI":"10.21037\/atm.2018.01.25","author":"S Volpi","year":"2018","unstructured":"Volpi S, Ali JM, Tasker A, Peryt A, Aresu G, Coonar AS (2018) The role of positron emission tomography in the diagnosis, staging and response assessment of non-small cell lung cancer. Ann Transl Med. https:\/\/doi.org\/10.21037\/atm.2018.01.25","journal-title":"Ann Transl Med"},{"key":"9825_CR5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.4103\/0256-4947.75771","volume":"31","author":"A Almuhaideb","year":"2011","unstructured":"Almuhaideb A, Papathanasiou N, Bomanji J (2011) 18F-FDG PET\/CT imaging in oncology. Ann Saudi Med 31:3\u201313","journal-title":"Ann Saudi Med"},{"key":"9825_CR6","doi-asserted-by":"publisher","first-page":"347","DOI":"10.2967\/jnumed.110.080382","volume":"52","author":"G El Fakhri","year":"2011","unstructured":"El Fakhri G, Surti S, Trott CM, Scheuermann J, Karp JS (2011) Improvement in lesion detection with whole-body oncologic time-of-flight PET. J Nucl Med 52:347\u2013353","journal-title":"J Nucl Med"},{"key":"9825_CR7","doi-asserted-by":"publisher","first-page":"3","DOI":"10.2967\/jnumed.116.184028","volume":"59","author":"SR Cherry","year":"2018","unstructured":"Cherry SR, Jones T, Karp JS, Qi JY, Moses WW, Badawi RD (2018) Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care. J Nucl Med 59:3\u201312","journal-title":"J Nucl Med"},{"key":"9825_CR8","doi-asserted-by":"crossref","unstructured":"Roncali E, Cherry SR (2011) Application of silicon photomultipliers to positron emission tomography. Ann Biomed Eng 39:1358-1377","DOI":"10.1007\/s10439-011-0266-9"},{"key":"9825_CR9","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.2967\/jnumed.118.215418","volume":"60","author":"J van Sluis","year":"2019","unstructured":"van Sluis J, de Jong J, Schaar J et al (2019) Performance characteristics of the digital biograph vision PET\/CT system. J Nucl Med 60:1031\u20131036","journal-title":"J Nucl Med"},{"key":"9825_CR10","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1109\/TRPMS.2020.2985403","volume":"4","author":"S Surti","year":"2020","unstructured":"Surti S, Pantel AR, Karp JS (2020) Total body PET: why, how, what for? IEEE Trans Radiat Plasma Med Sci 4:283\u2013292","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"key":"9825_CR11","doi-asserted-by":"publisher","first-page":"2395","DOI":"10.1007\/s00259-021-05282-7","volume":"48","author":"I Alberts","year":"2021","unstructured":"Alberts I, H\u00fcnermund JN, Prenosil G et al (2021) Clinical performance of long axial field of view PET\/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET\/CT. Eur J Nucl Med Mol Imaging 48:2395\u20132404","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR12","doi-asserted-by":"publisher","first-page":"299","DOI":"10.2967\/jnumed.119.226498","volume":"60","author":"RD Badawi","year":"2019","unstructured":"Badawi RD, Shi HC, Hu PC et al (2019) First human imaging studies with the EXPLORER total-body PET scanner. J Nucl Med 60:299\u2013303","journal-title":"J Nucl Med"},{"key":"9825_CR13","doi-asserted-by":"publisher","first-page":"861","DOI":"10.2967\/jnumed.120.250597","volume":"62","author":"BA Spencer","year":"2021","unstructured":"Spencer BA, Berg E, Schmall JP et al (2021) Performance evaluation of the uEXPLORER total-body PET\/CT scanner based on NEMA NU 2\u20132018 with additional tests to characterize PET scanners with a long axial field of view. J Nucl Med 62:861\u2013870","journal-title":"J Nucl Med"},{"key":"9825_CR14","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.cpet.2020.09.007","volume":"16","author":"XL Sui","year":"2021","unstructured":"Sui XL, Liu GB, Hu PC et al (2021) Total-body PET\/computed tomography highlights in clinical practice: experiences from Zhongshan Hospital, Fudan University. PET Clin 16:9\u201314","journal-title":"PET Clin"},{"key":"9825_CR15","doi-asserted-by":"publisher","first-page":"2507","DOI":"10.1007\/s00259-020-04823-w","volume":"47","author":"YQ Zhang","year":"2020","unstructured":"Zhang YQ, Hu PC, Wu RZ et al (2020) The image quality, lesion detectability, and acquisition time of (18)F-FDG total-body PET\/CT in oncological patients. Eur J Nucl Med Mol Imaging 47:2507\u20132515","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR16","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1007\/s00259-021-05500-2","volume":"49","author":"GB Liu","year":"2022","unstructured":"Liu GB, Yu HJ, Shi D et al (2022) Short-time total-body dynamic PET imaging performance in quantifying the kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging 49:2493\u20132503","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR17","doi-asserted-by":"publisher","first-page":"1966","DOI":"10.1007\/s00259-020-05091-4","volume":"48","author":"H Tan","year":"2021","unstructured":"Tan H, Sui XL, Yin HY et al (2021) Total-body PET\/CT using half-dose FDG and compared with conventional PET\/CT using full-dose FDG in lung cancer. Eur J Nucl Med Mol Imaging 48:1966\u20131975","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR18","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1007\/s00259-021-05537-3","volume":"49","author":"H Tan","year":"2022","unstructured":"Tan H, Cai DJ, Sui XL et al (2022) Investigating ultra-low-dose total-body [18F]-FDG PET\/CT in colorectal cancer: initial experience. Eur J Nucl Med Mol Imaging 49:1002\u20131011","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR19","doi-asserted-by":"publisher","first-page":"2373","DOI":"10.1007\/s00259-020-05173-3","volume":"48","author":"GB Liu","year":"2021","unstructured":"Liu GB, Hu PC, Yu HJ et al (2021) Ultra-low-activity total-body dynamic PET imaging allows equal performance to full-activity PET imaging for investigating kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging 48:2373\u20132383","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR20","doi-asserted-by":"publisher","first-page":"959","DOI":"10.2967\/jnumed.121.262038","volume":"63","author":"Y Hu","year":"2022","unstructured":"Hu Y, Liu GB, Yu HJ et al (2022) Feasibility of acquisitions using total-body PET\/CT with an ultra-low 18F-FDG activity. J Nucl Med 63:959\u2013965","journal-title":"J Nucl Med"},{"key":"9825_CR21","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1007\/s00259-021-05357-5","volume":"48","author":"PC Hu","year":"2021","unstructured":"Hu PC, Zhang YQ, Yu HJ et al (2021) Total-body 18F-FDG PET\/CT scan in oncology patients: how fast could it be? Eur J Nucl Med Mol Imaging 48:2384\u20132394","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR22","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1007\/s00259-014-2961-x","volume":"42","author":"R Boellaard","year":"2015","unstructured":"Boellaard R, Delgado-Bolton R, Oyen WJG et al (2015) FDG PET\/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging 42:328\u2013354","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR23","doi-asserted-by":"publisher","first-page":"3378","DOI":"10.1007\/s00259-021-05304-4","volume":"48","author":"YM Zhao","year":"2021","unstructured":"Zhao YM, Li YH, Chen T et al (2021) Image quality and lesion detectability in low-dose pediatric 18F-FDG scans using total-body PET\/CT. Eur J Nucl Med Mol Imaging 48:3378\u20133385","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR24","doi-asserted-by":"publisher","first-page":"3738","DOI":"10.1007\/s00259-021-05380-6","volume":"48","author":"YJ Li","year":"2021","unstructured":"Li YJ, Zhang WB, Zhang H et al (2021) Ultra-short time imaging of total-body PET\/CT for cancer pain-induced untenable body position. Eur J Nucl Med Mol Imaging 48:3738\u20133740","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"9825_CR25","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TNS.2012.2197414","volume":"59","author":"DJ Kadrmas","year":"2012","unstructured":"Kadrmas DJ, Oktay MB, Casey ME, Hamill JJ (2012) Effect of scan time on oncologic lesion detection in whole-body PET. IEEE Trans Nucl Sci 59:1940\u20131947","journal-title":"IEEE Trans Nucl Sci"},{"key":"9825_CR26","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-017-0179-2","author":"S Adler","year":"2017","unstructured":"Adler S, Seidel J, Choyke P et al (2017) Minimum lesion detectability as a measure of PET system performance. EJNMMI Phys. https:\/\/doi.org\/10.1186\/s40658-017-0179-2","journal-title":"EJNMMI Phys"},{"key":"9825_CR27","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.2967\/jnumed.120.242305","volume":"61","author":"S Surti","year":"2020","unstructured":"Surti S, Viswanath V, Daube-Witherspoon ME, Conti M, Casey ME, Karp JS (2020) Benefit of improved performance with state-of-the art digital PET\/CT for lesion detection in oncology. J Nucl Med 61:1684\u20131690","journal-title":"J Nucl Med"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09825-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-023-09825-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09825-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T17:11:09Z","timestamp":1698167469000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-023-09825-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,20]]},"references-count":27,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2023,11]]}},"alternative-id":["9825"],"URL":"https:\/\/doi.org\/10.1007\/s00330-023-09825-4","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,20]]},"assertion":[{"value":"29 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Hongcheng Shi.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: Shuangliang Cao and Yun Zhou are members of Shanghai United Imaging Healthcare Co., serving uExplore (194\u00a0cm AFOV PET\/CT), and playing an important role in image reconstruction and investigation. All authors declare that they have no other conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Some study subjects or cohorts have been previously reported in Hu P, Zhang Y, Yu H et al Total-body (18)F-FDG PET\/CT scan in oncology patients: how fast could it be? Eur J Nucl Med Mol Imaging 2021;48(8):2384-2394.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 retrospective\u2022 performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}