{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,11]],"date-time":"2026-01-11T22:48:09Z","timestamp":1768171689870,"version":"3.49.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2023,7,20]],"date-time":"2023-07-20T00:00:00Z","timestamp":1689811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,7,20]],"date-time":"2023-07-20T00:00:00Z","timestamp":1689811200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-023-09913-5","type":"journal-article","created":{"date-parts":[[2023,7,20]],"date-time":"2023-07-20T12:01:55Z","timestamp":1689854515000},"page":"8521-8527","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["CT annulus sizing prior to transcatheter aortic valve replacement (TAVR): evaluation of free-breathing versus breath-holding acquisition"],"prefix":"10.1007","volume":"33","author":[{"given":"Adrien","family":"Cour","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julien","family":"Burel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthieu","family":"Garnier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Durand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthieu","family":"Demeyere","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7681-5252","authenticated-orcid":false,"given":"Jean-Nicolas","family":"Dacher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,7,20]]},"reference":[{"issue":"5","key":"9913_CR1","doi-asserted-by":"publisher","first-page":"2627","DOI":"10.1007\/s00330-019-06357-8","volume":"30","author":"M Francone","year":"2020","unstructured":"Francone M, Budde RPJ, Bremerich J et al (2020) CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting\u2014a consensus document by the European Society of Cardiovascular Radiology (ESCR). Eur Radiol 30(5):2627\u20132650","journal-title":"Eur Radiol"},{"issue":"5","key":"9913_CR2","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.jcct.2022.05.003","volume":"16","author":"J Steffen","year":"2022","unstructured":"Steffen J, Beckmann M, Haum M et al (2022) Systolic or diastolic CT image acquisition for transcatheter aortic valve replacement \u2013 an outcome analysis. J Cardiovasc Comput Tomogr 16(5):423\u2013430","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"6","key":"9913_CR3","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","volume":"6","author":"S Achenbach","year":"2012","unstructured":"Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6(6):366\u2013380","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"9913_CR4","doi-asserted-by":"crossref","unstructured":"Liu Z, Sun Y, Zhang Z, Chen L, Hong N (2016) Feasibility of free-breathing CCTA using 256-MDCT. Medicine (Baltimore) 95(27):e4096","DOI":"10.1097\/MD.0000000000004096"},{"issue":"1","key":"9913_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","volume":"13","author":"P Blanke","year":"2019","unstructured":"Blanke P, Weir-McCall JR, Achenbach S et al (2019) Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI) \/ transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr 13(1):1\u201320","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"21","key":"9913_CR6","doi-asserted-by":"publisher","first-page":"2717","DOI":"10.1016\/j.jacc.2021.02.038","volume":"77","author":"P G\u00e9n\u00e9reux","year":"2021","unstructured":"G\u00e9n\u00e9reux P, Piazza N, Alu MC et al (2021) Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical research. J Am Coll Cardiol 77(21):2717\u20132746","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"9913_CR7","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159","journal-title":"Biometrics"},{"issue":"4","key":"9913_CR8","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1093\/ejcts\/ezs043","volume":"41","author":"SAM Nashef","year":"2012","unstructured":"Nashef SAM, Roques F, Sharples LD et al (2012) EuroSCORE II. Eur J Cardiothorac Surg 41(4):734\u2013745","journal-title":"Eur J Cardiothorac Surg"},{"issue":"1","key":"9913_CR9","doi-asserted-by":"publisher","first-page":"93","DOI":"10.2214\/AJR.09.2833","volume":"194","author":"M Dewey","year":"2010","unstructured":"Dewey M, Vavere AL, Arbab-Zadeh A et al (2010) Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial. AJR Am J Roentgenol 194(1):93\u2013102","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"9913_CR10","doi-asserted-by":"publisher","first-page":"851","DOI":"10.2214\/AJR.10.6072","volume":"197","author":"P Stolzmann","year":"2011","unstructured":"Stolzmann P, Goetti RP, Maurovich-Horvat P et al (2011) Predictors of image quality in high-pitch coronary CT angiography. AJR Am J Roentgenol 197(4):851\u2013858","journal-title":"AJR Am J Roentgenol"},{"issue":"12","key":"9913_CR11","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1016\/j.acra.2020.08.003","volume":"28","author":"T Shuai","year":"2021","unstructured":"Shuai T, Li W, You Y et al (2021) Combined coronary CT angiography and evaluation of access vessels for TAVR patients in free-breathing with single contrast medium injection using a 16-cm-wide detector CT. Acad Radiol 28(12):1662\u20131668","journal-title":"Acad Radiol"},{"issue":"7","key":"9913_CR12","doi-asserted-by":"publisher","first-page":"2064","DOI":"10.1148\/rg.2016160079","volume":"36","author":"K Kalisz","year":"2016","unstructured":"Kalisz K, Buethe J, Saboo SS, Abbara S, Halliburton S, Rajiah P (2016) Artifacts at cardiac CT: physics and solutions. Radiographics 36(7):2064\u20132083","journal-title":"Radiographics"},{"issue":"5","key":"9913_CR13","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1007\/s00330-012-2703-z","volume":"23","author":"E-J Kang","year":"2013","unstructured":"Kang E-J, Lee J, Lee K-N, Kown H, Ha D-H, Kim RB (2013) An initial randomised study assessing free-breathing CCTA using 320-detector CT. Eur Radiol 23(5):1199\u20131209","journal-title":"Eur Radiol"},{"key":"9913_CR14","doi-asserted-by":"crossref","unstructured":"Bischoff B, Meinel FG, Del Prete A, Reiser MF, Becker H-C (2013) High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates. Eur J Radiol 82(12):2217\u20132221","DOI":"10.1016\/j.ejrad.2013.09.003"},{"key":"9913_CR15","doi-asserted-by":"crossref","unstructured":"Capilli F, Benndorf M, Soschynski M et al (2020) Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: comparison of systolic high-pitch vs. multiphasic data acquisition. Eur J Radiol 133:109366","DOI":"10.1016\/j.ejrad.2020.109366"},{"issue":"15","key":"9913_CR16","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1016\/j.jacc.2016.07.747","volume":"68","author":"M Gilard","year":"2016","unstructured":"Gilard M, Eltchaninoff H, Donzeau-Gouge P et al (2016) Late outcomes of transcatheter aortic valve replacement in high-risk patients. J Am Coll Cardiol 68(15):1637\u20131647","journal-title":"J Am Coll Cardiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09913-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-023-09913-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-09913-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,23]],"date-time":"2023-11-23T17:13:55Z","timestamp":1700759635000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-023-09913-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,20]]},"references-count":16,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["9913"],"URL":"https:\/\/doi.org\/10.1007\/s00330-023-09913-5","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,20]]},"assertion":[{"value":"4 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is Pr. Jean-Nicolas Dacher.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained by the Comit\u00e9 d\u2019Ethique pour la Recherche sur Donn\u00e9es Existantes et\/ou hors loi Jard\u00e9\u2014CHU de Rouen.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 retrospective\u2022 case-control study\u2022 performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}