{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:14:35Z","timestamp":1790612075756,"version":"4.1.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2023,9,2]],"date-time":"2023-09-02T00:00:00Z","timestamp":1693612800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,9,2]],"date-time":"2023-09-02T00:00:00Z","timestamp":1693612800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100015696","name":"Siemens Medical Solutions USA","doi-asserted-by":"publisher","award":["C00233808"],"award-info":[{"award-number":["C00233808"]}],"id":[{"id":"10.13039\/100015696","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-023-10157-6","type":"journal-article","created":{"date-parts":[[2023,9,2]],"date-time":"2023-09-02T08:01:57Z","timestamp":1693641717000},"page":"1692-1703","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Highly accelerated free-breathing real-time 2D flow imaging using compressed sensing and shared velocity encoding"],"prefix":"10.1007","volume":"34","author":[{"given":"Fei","family":"Xiong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tilman","family":"Emrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6164-5641","authenticated-orcid":false,"given":"U. Joseph","family":"Schoepf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"SarahRose","family":"Hall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean Marie","family":"Ruddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Giese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Lautenschlager","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Lena","family":"Emrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akos","family":"Varga-Szemes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,2]]},"reference":[{"key":"10157_CR1","doi-asserted-by":"publisher","first-page":"2172","DOI":"10.1007\/s00330-005-2829-3","volume":"15","author":"PD Gatehouse","year":"2005","unstructured":"Gatehouse PD, Keegan J, Crowe LA et al (2005) Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol 15:2172\u20132184","journal-title":"Eur Radiol"},{"key":"10157_CR2","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1002\/mrm.21778","volume":"60","author":"AF Stalder","year":"2008","unstructured":"Stalder AF, Russe MF, Frydrychowicz A, Bock J, Hennig J, Markl M (2008) Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters. Magn Reson Med 60:1218\u20131231","journal-title":"Magn Reson Med"},{"key":"10157_CR3","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1148\/rg.2020190039","volume":"40","author":"DT Wymer","year":"2020","unstructured":"Wymer DT, Patel KP, Burke WF 3rd, Bhatia VK (2020) Phase-contrast MRI: physics, techniques, and clinical applications. Radiographics 40:122\u2013140","journal-title":"Radiographics"},{"key":"10157_CR4","doi-asserted-by":"publisher","first-page":"1922","DOI":"10.3174\/ajnr.A3537","volume":"34","author":"SA Ansari","year":"2013","unstructured":"Ansari SA, Schnell S, Carroll T et al (2013) Intracranial 4D flow MRI: toward individualized assessment of arteriovenous malformation hemodynamics and treatment-induced changes. AJNR Am J Neuroradiol 34:1922\u20131928","journal-title":"AJNR Am J Neuroradiol"},{"key":"10157_CR5","doi-asserted-by":"publisher","first-page":"e4240","DOI":"10.1002\/nbm.4240","volume":"33","author":"H Haji-Valizadeh","year":"2020","unstructured":"Haji-Valizadeh H, Feng L, Ma LE et al (2020) Highly accelerated, real-time phase-contrast MRI using radial k-space sampling and GROG-GRASP reconstruction: a feasibility study in pediatric patients with congenital heart disease. NMR Biomed 33:e4240","journal-title":"NMR Biomed"},{"key":"10157_CR6","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12968-017-0330-1","volume":"19","author":"A Sun","year":"2017","unstructured":"Sun A, Zhao B, Li Y, He Q, Li R, Yuan C (2017) Real-time phase-contrast flow cardiovascular magnetic resonance with low-rank modeling and parallel imaging. J Cardiovasc Magn Reson 19:19","journal-title":"J Cardiovasc Magn Reson"},{"key":"10157_CR7","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1002\/mrm.23273","volume":"68","author":"HY Lin","year":"2012","unstructured":"Lin HY, Bender JA, Ding Y et al (2012) Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements. Magn Reson Med 68:703\u2013710","journal-title":"Magn Reson Med"},{"key":"10157_CR8","doi-asserted-by":"publisher","first-page":"2172","DOI":"10.1002\/mrm.24874","volume":"71","author":"M Akcakaya","year":"2014","unstructured":"Akcakaya M, Gulaka P, Basha TA, Ngo LH, Manning WJ, Nezafat R (2014) Free-breathing phase contrast MRI with near 100% respiratory navigator efficiency using k-space-dependent respiratory gating. Magn Reson Med 71:2172\u20132179","journal-title":"Magn Reson Med"},{"key":"10157_CR9","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/(SICI)1522-2594(200002)43:2<251::AID-MRM12>3.0.CO;2-#","volume":"43","author":"KS Nayak","year":"2000","unstructured":"Nayak KS, Pauly JM, Kerr AB, Hu BS, Nishimura DG (2000) Real-time color flow MRI. Magn Reson Med 43:251\u2013258","journal-title":"Magn Reson Med"},{"key":"10157_CR10","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1002\/mrm.20690","volume":"54","author":"R Nezafat","year":"2005","unstructured":"Nezafat R, Kellman P, Derbyshire JA, McVeigh ER (2005) Real-time blood flow imaging using autocalibrated spiral sensitivity encoding. Magn Reson Med 54:1557\u20131561","journal-title":"Magn Reson Med"},{"key":"10157_CR11","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1002\/jmri.1880050607","volume":"5","author":"JF Debatin","year":"1995","unstructured":"Debatin JF, Leung DA, Wildermuth S, Botnar R, Felblinger J, McKinnon GC (1995) Flow quantitation with echo-planar phase-contrast velocity mapping: in vitro and in vivo evaluation. J Magn Reson Imaging 5:656\u2013662","journal-title":"J Magn Reson Imaging"},{"key":"10157_CR12","doi-asserted-by":"publisher","first-page":"2077","DOI":"10.1002\/mrm.28065","volume":"83","author":"GT Kowalik","year":"2020","unstructured":"Kowalik GT, Knight D, Steeden JA, Muthurangu V (2020) Perturbed spiral real-time phase-contrast MR with compressive sensing reconstruction for assessment of flow in children. Magn Reson Med 83:2077\u20132091","journal-title":"Magn Reson Med"},{"key":"10157_CR13","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1002\/mrm.28750","volume":"86","author":"H Haji-Valizadeh","year":"2021","unstructured":"Haji-Valizadeh H, Guo R, Kucukseymen S et al (2021) Highly accelerated free-breathing real-time phase contrast cardiovascular MRI via complex-difference deep learning. Magn Reson Med 86:804\u2013819","journal-title":"Magn Reson Med"},{"key":"10157_CR14","unstructured":"Greiser A ZM, Schmidt M, Speier P, Mueller E (2014) Highly accelerated phase contrast imaging using compressed sensing and iterative reconstruction for high resolution short breathhold flow acquisitions.\u00a0Proc Intl Soc\u00a0Mag Reson Med 22:3851"},{"key":"10157_CR15","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s10334-013-0428-x","volume":"27","author":"C Forman","year":"2014","unstructured":"Forman C, Piccini D, Grimm R, Hutter J, Hornegger J, Zenge MO (2014) High-resolution 3D whole-heart coronary MRA: a study on the combination of data acquisition in multiple breath-holds and 1D residual respiratory motion compensation. MAGMA 27:435\u2013443","journal-title":"MAGMA"},{"key":"10157_CR16","unstructured":"Greise A FC, Wetzl J, Tillmanns C, Stalder A, Schmidt M, Zenge M, Mueller E (2015) Clinical evaluation and optimization of highly accelerated 2D and 4D phase contrast flow imaging applications using sparse sampling and iterative reconstruction.\u00a0Proc Intl Soc Mag Reson Med 23:4550"},{"key":"10157_CR17","unstructured":"Greiser A ZM, Schmidt M, Gulsun A, Stalder A (2014) Application of highly accelerated Cartesian phase contrast imaging using compressed sensing and iterative reconstruction to real-time and vector encoded flow imaging. Proc Intl Soc Mag Reson Med 22:3854"},{"key":"10157_CR18","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1016\/j.jss.2015.03.024","volume":"198","author":"J Birjiniuk","year":"2015","unstructured":"Birjiniuk J, Ruddy JM, Iffrig E et al (2015) Development and testing of a silicone in vitro model of descending aortic dissection. J Surg Res 198:502\u2013507","journal-title":"J Surg Res"},{"key":"10157_CR19","doi-asserted-by":"publisher","first-page":"3675","DOI":"10.1002\/mrm.27684","volume":"81","author":"LE Ma","year":"2019","unstructured":"Ma LE, Markl M, Chow K et al (2019) Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction. Magn Reson Med 81:3675\u20133690","journal-title":"Magn Reson Med"},{"key":"10157_CR20","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1002\/mrm.24980","volume":"72","author":"L Feng","year":"2014","unstructured":"Feng L, Grimm R, Block KT et al (2014) Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn Reson Med 72:707\u2013717","journal-title":"Magn Reson Med"},{"key":"10157_CR21","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s12968-018-0500-9","volume":"20","author":"JA Steeden","year":"2018","unstructured":"Steeden JA, Kowalik GT, Tann O, Hughes M, Mortensen KH, Muthurangu V (2018) Real-time assessment of right and left ventricular volumes and function in children using high spatiotemporal resolution spiral bSSFP with compressed sensing. J Cardiovasc Magn Reson 20:79","journal-title":"J Cardiovasc Magn Reson"},{"key":"10157_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/mrm.10501","volume":"50","author":"DC Peters","year":"2003","unstructured":"Peters DC, Derbyshire JA, McVeigh ER (2003) Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 50:1\u20136","journal-title":"Magn Reson Med"},{"key":"10157_CR23","doi-asserted-by":"publisher","first-page":"119361","DOI":"10.1016\/j.neuroimage.2022.119361","volume":"258","author":"P Liu","year":"2022","unstructured":"Liu P, Fall S, Baledent O (2022) Use of real-time phase-contrast MRI to quantify the effect of spontaneous breathing on the cerebral arteries. Neuroimage 258:119361","journal-title":"Neuroimage"},{"key":"10157_CR24","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1002\/jmri.25664","volume":"46","author":"W Wu","year":"2017","unstructured":"Wu W, Miller KL (2017) Image formation in diffusion MRI: a review of recent technical developments. J Magn Reson Imaging 46:646\u2013662","journal-title":"J Magn Reson Imaging"},{"key":"10157_CR25","doi-asserted-by":"publisher","first-page":"20200825","DOI":"10.1259\/bjr.20200825","volume":"94","author":"E Gumeler","year":"2021","unstructured":"Gumeler E, Parlak S, Yazici G, Karabulut E, Kiratli H, Oguz KK (2021) Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma. Br J Radiol 94:20200825","journal-title":"Br J Radiol"},{"key":"10157_CR26","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s12880-016-0128-x","volume":"16","author":"C Andersson","year":"2016","unstructured":"Andersson C, Kihlberg J, Ebbers T, Lindstrom L, Carlhall CJ, Engvall JE (2016) Phase-contrast MRI volume flow\u2013a comparison of breath held and navigator based acquisitions. BMC Med Imaging 16:26","journal-title":"BMC Med Imaging"},{"key":"10157_CR27","first-page":"422","volume":"39","author":"M Markl","year":"2015","unstructured":"Markl M, Fluckiger J, Lee DC, Ng J, Goldberger JJ (2015) Velocity quantification by electrocardiography-gated phase contrast magnetic resonance imaging in patients with cardiac arrhythmia: a simulation study based on real time transesophageal echocardiography data in atrial fibrillation. J Comput Assist Tomogr 39:422\u2013427","journal-title":"J Comput Assist Tomogr"},{"key":"10157_CR28","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1186\/s12968-021-00811-7","volume":"23","author":"M Kocaoglu","year":"2021","unstructured":"Kocaoglu M, Pednekar A, Tkach JA, Taylor MD (2021) Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution. J Cardiovasc Magn Reson 23:113","journal-title":"J Cardiovasc Magn Reson"},{"key":"10157_CR29","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1002\/mrm.23088","volume":"64","author":"DD Kim","year":"2012","unstructured":"Kim DD, Dyvorne HA, Otazo R, Feng L, Sodickson DK, Lee VS (2012) Accelerated phase-contrast cine MRI using k-t SPARSE-SENSE. Magn Reson Med 64:1054\u20131064","journal-title":"Magn Reson Med"},{"key":"10157_CR30","doi-asserted-by":"publisher","first-page":"1276","DOI":"10.1002\/jmri.25862","volume":"47","author":"X Shen","year":"2018","unstructured":"Shen X, Schnell S, Barker AJ et al (2018) Voxel-by-voxel 4D flow MRI-based assessment of regional reverse flow in the aorta. J Magn Reson Imaging 47:1276\u20131286","journal-title":"J Magn Reson Imaging"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-10157-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-023-10157-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-023-10157-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,16]],"date-time":"2024-02-16T18:11:07Z","timestamp":1708107067000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-023-10157-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,2]]},"references-count":30,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,3]]}},"alternative-id":["10157"],"URL":"https:\/\/doi.org\/10.1007\/s00330-023-10157-6","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,2]]},"assertion":[{"value":"11 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The scientific guarantor of this publication is U. Joseph Schoepf.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"We report the following conflicts of interest: Fei Xiong, Ning Jin and Daniel Giese are employees of Siemens Healthcare. Tilman Emrich received a speaker fee and travel support from Siemens Healthcare. U. Joseph Schoepf receives institutional research support and\/or personal fees from Bayer, Bracco, Elucid Bioimaging, Guerbet, HeartFlow, and Siemens Healthcare. Jean Marie Ruddy is a surgical proctor at CVRx. Akos Varga-Szemes receives institutional research support from Siemens Healthcare and consulting fees from Bayer and Elucid Bioimaging. The other authors have no conflict of interest to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors has significant statistical expertise.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Volunteers gave written informed consent prior to the MRI.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"No study subject or cohorts have been previously reported in this study.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"value":"\u2022 prospective\u2022 experimental\u2022 performed at one institution","order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}