{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T02:41:58Z","timestamp":1782960118245,"version":"3.54.5"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T00:00:00Z","timestamp":1721779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T00:00:00Z","timestamp":1721779200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-024-10974-3","type":"journal-article","created":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T12:05:30Z","timestamp":1721822730000},"page":"885-896","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Multi-reader multiparametric DECT study evaluating different strengths of iterative and deep learning-based image reconstruction techniques"],"prefix":"10.1007","volume":"35","author":[{"given":"Jinjin","family":"Cao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nayla","family":"Mroueh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Lennartz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathaniel D.","family":"Mercaldo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nisanard","family":"Pisuchpen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sasiprang","family":"Kongboonvijit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shravya","family":"Srinivas Rao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kampon","family":"Yuenyongsinchai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodore T.","family":"Pierce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madeleine","family":"Sertic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6714-9190","authenticated-orcid":false,"given":"Avinash R.","family":"Kambadakone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,24]]},"reference":[{"key":"10974_CR1","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1148\/radiol.2015142631","volume":"276","author":"CH McCollough","year":"2015","unstructured":"McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637\u2013653","journal-title":"Radiology"},{"key":"10974_CR2","doi-asserted-by":"publisher","first-page":"651","DOI":"10.2214\/AJR.20.25093","volume":"217","author":"A Mileto","year":"2021","unstructured":"Mileto A, Ananthakrishnan L, Morgan DE, Yeh BM, Marin D, Kambadakone AR (2021) Clinical implementation of dual-energy CT for gastrointestinal imaging. AJR Am J Roentgenol 217:651\u2013663","journal-title":"AJR Am J Roentgenol"},{"key":"10974_CR3","doi-asserted-by":"publisher","unstructured":"Cao J, Lennartz S, Parakh A et al (2021) Dual-layer dual-energy CT for characterization of adrenal nodules: can virtual unenhanced images replace true unenhanced acquisitions? Abdom Radiol (NY) 46:4345\u20134352. https:\/\/doi.org\/10.1007\/s00261-021-03062-3","DOI":"10.1007\/s00261-021-03062-3"},{"key":"10974_CR4","doi-asserted-by":"publisher","unstructured":"Cao J, Lennartz S, Pisuchpen N et al (2022) Renal lesion characterization by dual-layer dual-energy CT: comparison of virtual and true unenhanced images. AJR Am J Roentgenol 219:614\u2013623. https:\/\/doi.org\/10.2214\/AJR.21.27272","DOI":"10.2214\/AJR.21.27272"},{"key":"10974_CR5","doi-asserted-by":"publisher","unstructured":"Noda Y, Tochigi T, Parakh A, Joseph E, Hahn PF, Kambadakone A (2021) Low keV portal venous phase as a surrogate for pancreatic phase in a pancreatic protocol dual-energy CT: feasibility, image quality, and lesion conspicuity. Eur Radiol 31:6898\u20136908. https:\/\/doi.org\/10.1007\/s00330-021-07744-w","DOI":"10.1007\/s00330-021-07744-w"},{"key":"10974_CR6","doi-asserted-by":"publisher","first-page":"3317","DOI":"10.1007\/s00261-018-1636-7","volume":"43","author":"D Pfeiffer","year":"2018","unstructured":"Pfeiffer D, Parakh A, Patino M, Kambadakone A, Rummeny EJ, Sahani DV (2018) Iodine material density images in dual-energy CT: quantification of contrast uptake and washout in HCC. Abdom Radiol (NY) 43:3317\u20133323. https:\/\/doi.org\/10.1007\/s00261-018-1636-7","journal-title":"Abdom Radiol (NY)"},{"key":"10974_CR7","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1148\/rg.2021200102","volume":"41","author":"A Parakh","year":"2021","unstructured":"Parakh A, Lennartz S, An C et al (2021) Dual-energy CT images: pearls and pitfalls Radiographics 41:98\u2013119. https:\/\/doi.org\/10.1148\/rg.2021200102","journal-title":"Radiographics"},{"key":"10974_CR8","doi-asserted-by":"publisher","first-page":"S9","DOI":"10.2214\/AJR.12.9121","volume":"199","author":"L Yu","year":"2012","unstructured":"Yu L, Leng S, McCollough CH (2012) Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol 199:S9\u2013S15.","journal-title":"AJR Am J Roentgenol"},{"key":"10974_CR9","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/j.rcl.2023.06.015","volume":"61","author":"S Srinivas-Rao","year":"2023","unstructured":"Srinivas-Rao S, Cao J, Marin D, Kambadakone A (2023) Dual-energy computed tomography to photon counting computed tomography: emerging technological innovations. Radiol Clin North Am 61:933\u2013944. https:\/\/doi.org\/10.1016\/j.rcl.2023.06.015","journal-title":"Radiol Clin North Am"},{"key":"10974_CR10","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1148\/rg.2020200038","volume":"40","author":"P Rajiah","year":"2020","unstructured":"Rajiah P, Parakh A, Kay F, Baruah D, Kambadakone AR, Leng S (2020) Update on multienergy CT: physics, principles, and applications. Radiographics 40:1284\u20131308. https:\/\/doi.org\/10.1148\/rg.2020200038","journal-title":"Radiographics"},{"key":"10974_CR11","doi-asserted-by":"publisher","unstructured":"Lennartz S, Hokamp NG, Kambadakone A (2022) Dual-energy CT of the abdomen: radiology in training. Radiology 305:19\u201327. https:\/\/doi.org\/10.1148\/radiol.212914","DOI":"10.1148\/radiol.212914"},{"key":"10974_CR12","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2214\/AJR.19.22332","volume":"215","author":"CT Jensen","year":"2020","unstructured":"Jensen CT, Liu X, Tamm EP et al (2020) Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience. AJR Am J Roentgenol 215:50\u201357","journal-title":"AJR Am J Roentgenol"},{"key":"10974_CR13","doi-asserted-by":"publisher","first-page":"710.e15","DOI":"10.1016\/j.crad.2021.03.010","volume":"76","author":"T Kaga","year":"2021","unstructured":"Kaga T, Noda Y, Fujimoto K et al (2021) Deep-learning-based image reconstruction in dynamic contrast-enhanced abdominal CT: image quality and lesion detection among reconstruction strength levels. Clin Radiol 76:710.e15\u2013710.e24","journal-title":"Clin Radiol"},{"key":"10974_CR14","unstructured":"Hsieh J, Liu E, Nett B, Tang J, Thibault J, Sahney S (2019). A new era of image reconstruction: TrueFidelity. https:\/\/www.gehealthcare.com\/-\/jssmedia\/040dd213fa89463287155151fdb01922.pdf"},{"key":"10974_CR15","doi-asserted-by":"publisher","first-page":"8342","DOI":"10.1007\/s00330-021-07952-4","volume":"31","author":"A Parakh","year":"2021","unstructured":"Parakh A, Cao J, Pierce TT, Blake MA, Savage CA, Kambadakone AR (2021) Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations. Eur Radiol 31:8342\u20138353","journal-title":"Eur Radiol"},{"key":"10974_CR16","doi-asserted-by":"publisher","unstructured":"Xu JJ, L\u00f6nn L, Budtz-J\u00f8rgensen E, Hansen KL, Ulriksen PS (2022) Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT. Eur Radiol 32:7098\u20137107. https:\/\/doi.org\/10.1007\/s00330-022-09018-5","DOI":"10.1007\/s00330-022-09018-5"},{"key":"10974_CR17","doi-asserted-by":"publisher","unstructured":"Sato M, Ichikawa Y, Domae K et al (2022) Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen. Eur Radiol 32:5499\u20135507. https:\/\/doi.org\/10.1007\/s00330-022-08647-0","DOI":"10.1007\/s00330-022-08647-0"},{"key":"10974_CR18","unstructured":"Leonardi M, Bongartz G, Geleijns J, Golding S et al (1999). European guidelines on quality criteria for computed tomography. European Commission. http:\/\/www.drs.dk\/guidelines\/ct\/quality\/htmlindex.htm"},{"key":"10974_CR19","doi-asserted-by":"publisher","unstructured":"Cao J, Mroueh N, Pisuchpen N et al (2023) Can 1.25 mm thin-section images generated with deep learning image reconstruction technique replace standard-of-care 5 mm images in abdominal CT? Abdom Radiol (NY) 48:3253\u20133264. https:\/\/doi.org\/10.1007\/s00261-023-03992-0","DOI":"10.1007\/s00261-023-03992-0"},{"key":"10974_CR20","doi-asserted-by":"publisher","first-page":"20201086","DOI":"10.1259\/bjr.20201086","volume":"94","author":"L Cao","year":"2021","unstructured":"Cao L, Liu X, Li J et al (2021) A study of using a deep learning image reconstruction to improve the image quality of extremely low-dose contrast-enhanced abdominal CT for patients with hepatic lesions. Br J Radiol 94:20201086","journal-title":"Br J Radiol"},{"key":"10974_CR21","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.clinimag.2022.04.016","volume":"88","author":"M Saleh","year":"2022","unstructured":"Saleh M, Mujtaba B, Jensen C et al (2022) Feasibility of half the recommended dose of IV contrast in DECT: image quality evaluation and diagnostic acceptability in cancer patients. Clin Imaging 88:59\u201365. https:\/\/doi.org\/10.1016\/j.clinimag.2022.04.016","journal-title":"Clin Imaging"},{"key":"10974_CR22","doi-asserted-by":"publisher","first-page":"3660","DOI":"10.1007\/s00330-023-09520-4","volume":"33","author":"HJ Kang","year":"2023","unstructured":"Kang HJ, Lee JM, Ahn C et al.(2023) Low dose of contrast agent and low radiation liver computed tomography with deep-learning-based contrast boosting model in participants at high-risk for hepatocellular carcinoma: prospective, randomized, double-blind study. Eur Radiol 33:3660\u20133670. https:\/\/doi.org\/10.1007\/s00330-023-09520-4","journal-title":"Eur Radiol"},{"key":"10974_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2020.108909","volume":"126","author":"S Sawall","year":"2020","unstructured":"Sawall S, Klein L, Amato C et al (2020) Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 126:108909. https:\/\/doi.org\/10.1016\/j.ejrad.2020.108909","journal-title":"Eur J Radiol"},{"key":"10974_CR24","unstructured":"R: The R Project for Statistical Computing. https:\/\/www.r-project.org\/. Accessed 4 May 2023"},{"key":"10974_CR25","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1111\/j.2517-6161.1995.tb02031.x","volume":"57","author":"Y Benjamini","year":"1995","unstructured":"Benjamini Y, Hochberg Y (1995) Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc Ser B 57:289\u2013300. http:\/\/www.jstor.org\/stable\/2346101","journal-title":"J R Stat Soc Ser B"},{"key":"10974_CR26","unstructured":"Gwet KL (2014, ISBN:978-0970806284) Handbook of inter-rater reliability. 4th edn. Advanced Analytics, LLC"},{"key":"10974_CR27","doi-asserted-by":"publisher","first-page":"1715","DOI":"10.1016\/j.ejrad.2014.06.004","volume":"83","author":"Y Yamada","year":"2014","unstructured":"Yamada Y, Jinzaki M, Hosokawa T, Tanami Y, Abe T, Kuribayashi S (2014) Abdominal CT: an intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination. Eur J Radiol 83:1715\u20131722","journal-title":"Eur J Radiol"},{"key":"10974_CR28","doi-asserted-by":"publisher","first-page":"3217","DOI":"10.1007\/s00261-020-02888-7","volume":"46","author":"J Yoo","year":"2021","unstructured":"Yoo J, Lee JM, Yoon JH et al (2021) Comparison of low kVp CT and dual-energy CT for the evaluation of hypervascular hepatocellular carcinoma. Abdom Radiol (NY) 46:3217\u20133226","journal-title":"Abdom Radiol (NY)"},{"key":"10974_CR29","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1097\/RCT.0000000000001316","volume":"46","author":"E Fair","year":"2022","unstructured":"Fair E, Profio M, Kulkarni N et al (2022) Image quality evaluation in dual-energy CT of the chest, abdomen, and pelvis in obese patients with deep learning image reconstruction. J Comput Assist Tomogr 46:604\u2013611","journal-title":"J Comput Assist Tomogr"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-10974-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-024-10974-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-10974-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T10:11:38Z","timestamp":1738318298000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-024-10974-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,24]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["10974"],"URL":"https:\/\/doi.org\/10.1007\/s00330-024-10974-3","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,24]]},"assertion":[{"value":"19 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Avinash Kambadakone.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"A.K.: Research grants (GE Healthcare, Philips Healthcare, and PanCAN). S.L. is a member of the Scientific Editorial Board (section: Computed tomography) for European Radiology, they have not participated in the selection nor review processes for this article. All remaining other authors declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Dr. Nathaniel D. Mercaldo, PhD kindly provided statistical advice and help for this manuscript. Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, White 270, Boston, MA 02114-2696, USA, and this expert is one of the authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"None of the study subjects or cohorts have been previously reported.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}