{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:19:47Z","timestamp":1786979987099,"version":"build-2736575974"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T00:00:00Z","timestamp":1723161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T00:00:00Z","timestamp":1723161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-024-11009-7","type":"journal-article","created":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T13:02:12Z","timestamp":1723208532000},"page":"1067-1075","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Feasibility of a single-phase portal venous CT protocol using bolus tracking technique and lean body weight-based contrast media dose"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3465-0151","authenticated-orcid":false,"given":"Riccardo","family":"Valletta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Bonatti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenzo","family":"Vingiani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentina","family":"Corato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernardo","family":"Proner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Lombardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Avesani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrizia","family":"Pertner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia A.","family":"Zamboni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,9]]},"reference":[{"key":"11009_CR1","doi-asserted-by":"publisher","first-page":"109","DOI":"10.2214\/ajr.175.1.1750109","volume":"175","author":"ME O\u2019Malley","year":"2000","unstructured":"O\u2019Malley ME, Halpern E, Mueller PR, Gazelle GS (2000) Helical CT protocols for the abdomen and pelvis. AJR Am J Roentgenol 175:109\u2013113","journal-title":"AJR Am J Roentgenol"},{"key":"11009_CR2","doi-asserted-by":"publisher","first-page":"753","DOI":"10.2214\/ajr.167.3.8751695","volume":"167","author":"K Mitsuzaki","year":"1996","unstructured":"Mitsuzaki K, Yamashita Y, Ogata I et al (1996) Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. AJR Am J Roentgenol 167:753\u2013757","journal-title":"AJR Am J Roentgenol"},{"key":"11009_CR3","doi-asserted-by":"publisher","first-page":"147","DOI":"10.2214\/AJR.05.0512","volume":"188","author":"S Monzawa","year":"2007","unstructured":"Monzawa S, Ichikawa T, Nakajima H et al (2007) Dynamic CT for detecting small hepatocellular carcinoma: usefulness of delayed phase imaging. AJR Am J Roentgenol 188:147\u2013153","journal-title":"AJR Am J Roentgenol"},{"key":"11009_CR4","doi-asserted-by":"publisher","first-page":"W25","DOI":"10.2214\/AJR.04.1878","volume":"187","author":"S Goshima","year":"2006","unstructured":"Goshima S, Kanematsu M, Kondo H et al (2006) MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases. AJR Am J Roentgenol 187:W25\u2013W32","journal-title":"AJR Am J Roentgenol"},{"key":"11009_CR5","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1148\/radiol.10090908","volume":"256","author":"KT Bae","year":"2010","unstructured":"Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32\u201361","journal-title":"Radiology"},{"key":"11009_CR6","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1148\/radiology.210.1.r99ja2197","volume":"210","author":"ME Tublin","year":"1999","unstructured":"Tublin ME, Tessler FN, Cheng SL et al (1999) Effect of injection rate of contrast medium on pancreatic and hepatic helical CT. Radiology 210:97\u2013101","journal-title":"Radiology"},{"key":"11009_CR7","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1148\/radiology.192.2.8029399","volume":"192","author":"WD Foley","year":"1994","unstructured":"Foley WD, Hoffmann RG, Quiroz FA et al (1994) Hepatic helical CT: contrast material injection protocol. Radiology 192:367\u2013371","journal-title":"Radiology"},{"key":"11009_CR8","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1148\/radiology.206.2.9457200","volume":"206","author":"KT Bae","year":"1998","unstructured":"Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate-pharmacokinetic analysis and experimental porcine model. Radiology 206:455\u2013464","journal-title":"Radiology"},{"key":"11009_CR9","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1148\/radiol.2243011188","volume":"224","author":"K Awai","year":"2002","unstructured":"Awai K, Takada K, Onishi H, Hori S (2002) Aortic and hepatic enhancement and tumor-to-liver contrast: analysis of the effect of different concentrations of contrast material at multi\u2013detector row helical CT. Radiology 224:757\u2013763","journal-title":"Radiology"},{"key":"11009_CR10","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1148\/radiology.216.3.r00se26718","volume":"216","author":"Y Yamashita","year":"2000","unstructured":"Yamashita Y, Komohara Y, Takahashi M et al (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material\u2014a prospective randomized study. Radiology 216:718\u2013723","journal-title":"Radiology"},{"key":"11009_CR11","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1148\/radiol.2212000784","volume":"221","author":"CH McCollough","year":"2001","unstructured":"McCollough CH, Bruesewitz MR, Vrtiska TJ et al (2001) Image quality and dose comparison among screen-film, computed, and CT scanned projection radiography: applications to CT urography. Radiology 221:395\u2013403","journal-title":"Radiology"},{"key":"11009_CR12","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1148\/radiology.217.2.r00nv35430","volume":"217","author":"W Huda","year":"2000","unstructured":"Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430\u2013435","journal-title":"Radiology"},{"key":"11009_CR13","doi-asserted-by":"crossref","unstructured":"Zamboni GA, Gourtsoyianni S, Sourlas E, Raptopoulos VD (2009) Value of customized scan timing determined by tracking liver enhancement in oncology patients. J Comput Assist Tomogr 33:253\u2013258","DOI":"10.1097\/RCT.0b013e318177e5c7"},{"key":"11009_CR14","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1007\/s00330-011-2310-4","volume":"22","author":"H Brodoefel","year":"2012","unstructured":"Brodoefel H, Tognolini A, Zamboni GA et al (2012) Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging. Eur Radiol 22:812\u2013820","journal-title":"Eur Radiol"},{"key":"11009_CR15","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.2214\/AJR.08.1407","volume":"192","author":"Y Yanaga","year":"2009","unstructured":"Yanaga Y, Awai K, Nakaura T et al (2009) Effect of contrast injection protocols with dose adjusted to the estimated lean patient body weight on aortic enhancement at CT angiography. AJR Am J Roentgenol 192:1071\u20131078","journal-title":"AJR Am J Roentgenol"},{"key":"11009_CR16","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1148\/radiol.2432060390","volume":"243","author":"LM Ho","year":"2007","unstructured":"Ho LM, Nelson RC, DeLong DM (2007) Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi\u2013detector row CT? Radiology 243:431\u2013437","journal-title":"Radiology"},{"key":"11009_CR17","doi-asserted-by":"publisher","first-page":"1855","DOI":"10.1007\/s00330-013-2808-z","volume":"23","author":"H Kondo","year":"2013","unstructured":"Kondo H, Kanematsu M, Goshima S et al (2013) Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? Eur Radiol 23:1855\u20131861","journal-title":"Eur Radiol"},{"key":"11009_CR18","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1148\/radiol.09090369","volume":"254","author":"H Kondo","year":"2010","unstructured":"Kondo H, Kanematsu M, Goshima S et al (2010) Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology 254:163\u2013169","journal-title":"Radiology"},{"key":"11009_CR19","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1148\/radiol.2492080033","volume":"249","author":"H Kondo","year":"2008","unstructured":"Kondo H, Kanematsu M, Goshima S et al (2008) Abdominal multidetector CT in patients with varying body fat percentages: estimation of optimal contrast material dose. Radiology 249:872\u2013877","journal-title":"Radiology"},{"key":"11009_CR20","first-page":"1","volume":"2018","author":"D Caruso","year":"2018","unstructured":"Caruso D, De Santis D, Rivosecchi F et al (2018) Lean body weight-tailored iodinated contrast injection in obese patient: Boer versus James formula. Biomed Res Int 2018:1\u20136","journal-title":"Biomed Res Int"},{"key":"11009_CR21","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1016\/j.acra.2019.07.014","volume":"27","author":"AF Costa","year":"2020","unstructured":"Costa AF, Peet K, Abdolell M (2020) Dosing iodinated contrast media according to lean versus total body weight at abdominal CT: a stratified randomized controlled trial. Acad Radiol 27:833\u2013840","journal-title":"Acad Radiol"},{"key":"11009_CR22","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1177\/0284185118801137","volume":"60","author":"K Peet","year":"2019","unstructured":"Peet K, Clarke SE, Costa AF (2019) Hepatic enhancement differences when dosing iodinated contrast media according to total versus lean body weight. Acta Radiol 60:807\u2013814","journal-title":"Acta Radiol"},{"key":"11009_CR23","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1148\/radiol.2451061585","volume":"245","author":"LL Chu","year":"2007","unstructured":"Chu LL, Joe BN, Westphalen ACA et al (2007) Patient-specific time to peak abdominal organ enhancement varies with time to peak aortic enhancement at MR imaging. Radiology 245:779\u2013787","journal-title":"Radiology"},{"key":"11009_CR24","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1148\/radiology.207.3.9609886","volume":"207","author":"KT Bae","year":"1998","unstructured":"Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207:647\u2013655","journal-title":"Radiology"},{"key":"11009_CR25","first-page":"F632","volume":"247","author":"P Boer","year":"1984","unstructured":"Boer P (1984) Estimated lean body mass as an index for normalization of body fluid volumes in humans. Am J Physiol 247:F632\u2013F636","journal-title":"Am J Physiol"},{"key":"11009_CR26","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1148\/radiol.2016152031","volume":"278","author":"U Nyman","year":"2016","unstructured":"Nyman U (2016) James lean body weight formula is not appropriate for determining CT contrast media dose in patients with high body mass index. Radiology 278:956\u2013957","journal-title":"Radiology"},{"key":"11009_CR27","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1148\/radiology.195.2.7724752","volume":"195","author":"JP Heiken","year":"1995","unstructured":"Heiken JP, Brink JA, McClennan BL et al (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195:353\u2013357","journal-title":"Radiology"},{"key":"11009_CR28","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s13244-021-00980-0","volume":"12","author":"D Caruso","year":"2021","unstructured":"Caruso D, Rosati E, Panvini N et al (2021) Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols. Insights Imaging 12:40","journal-title":"Insights Imaging"},{"key":"11009_CR29","doi-asserted-by":"publisher","DOI":"10.1186\/s40644-018-0159-3","volume":"18","author":"CS Ng","year":"2018","unstructured":"Ng CS, Kalva SP, Gunnarsson C et al (2018) Risk of renal events following intravenous iodinated contrast material administration among inpatients admitted with cancer a retrospective hospital claims analysis. Cancer Imaging 18:30","journal-title":"Cancer Imaging"},{"key":"11009_CR30","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/j.rx.2020.02.002","volume":"63","author":"A Barrios L\u00f3pez","year":"2021","unstructured":"Barrios L\u00f3pez A, Garc\u00eda Mart\u00ednez F, Rodr\u00edguez JI et al (2021) Incidence of contrast-induced nephropathy after a computed tomography scan. Radiologia 63:307\u2013313","journal-title":"Radiologia"},{"key":"11009_CR31","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1007\/s10140-022-02077-7","volume":"29","author":"LS Eibschutz","year":"2022","unstructured":"Eibschutz LS, Gholamrezanezhad A (2022) How low can we go? Strategies and recommendations to combat the iodinated contrast shortage. Emerg Radiol 29:925\u2013928","journal-title":"Emerg Radiol"},{"key":"11009_CR32","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.ejrad.2008.01.048","volume":"70","author":"E Arana","year":"2009","unstructured":"Arana E, Mart\u00ed-Bonmat\u00ed L, Tobarra E, Sierra C (2009) Cost reduction in abdominal CT by weight-adjusted dose. Eur J Radiol 70:507\u2013511","journal-title":"Eur J Radiol"},{"key":"11009_CR33","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13244-022-01175-x","volume":"13","author":"HM Dekker","year":"2022","unstructured":"Dekker HM, Stroomberg GJ, Prokop M (2022) Tackling the increasing contamination of the water supply by iodinated contrast media. Insights Imaging 13:30","journal-title":"Insights Imaging"},{"key":"11009_CR34","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.jacr.2023.02.036","volume":"21","author":"JH Thrall","year":"2024","unstructured":"Thrall JH, Brink JA, Zalis ME (2024) The environmental, social, governance movement and radiology: opportunities and strategy. J Am Coll Radiol 21:265\u2013270","journal-title":"J Am Coll Radiol"},{"key":"11009_CR35","doi-asserted-by":"crossref","unstructured":"Rengier F, Notohamiprodjo M, Weber M-A (2024) Thoughts on sustainability in the use of iodinated contrast media in CT: a practice-oriented review based on the example of a hospital and a private practice. RoFo 196:819\u2013826","DOI":"10.1055\/a-2246-6697"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-11009-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-024-11009-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-11009-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T17:54:37Z","timestamp":1738259677000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-024-11009-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,9]]},"references-count":35,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["11009"],"URL":"https:\/\/doi.org\/10.1007\/s00330-024-11009-7","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,9]]},"assertion":[{"value":"19 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is R.V.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"G.A.Z. is an Editor of\n                      European Radiology\n                      , they did not participate in the selection nor review processes for this article. The remaining authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"One of the authors (V.V.) has significant statistical expertise. Moreover, no complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"None of the study subjects or cohorts have been included in previously published studies.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}