{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:19:47Z","timestamp":1786979987869,"version":"build-2736575974"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T00:00:00Z","timestamp":1732147200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T00:00:00Z","timestamp":1732147200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-024-11170-z","type":"journal-article","created":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T09:27:24Z","timestamp":1732181244000},"page":"3486-3498","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Automatic patient centering in computed tomography: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8570-1161","authenticated-orcid":false,"given":"Yasser H.","family":"Hadi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauren","family":"Keaney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"England","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niamh","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"McEntee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,21]]},"reference":[{"key":"11170_CR1","first-page":"587","volume":"58","author":"M Lell","year":"2023","unstructured":"Lell M, Kachelrie\u00df M (2023) Computed tomography 2.0: new detector technology, AI, and other developments. Invest Radiol 58:587\u2013601","journal-title":"Invest Radiol"},{"key":"11170_CR2","doi-asserted-by":"publisher","first-page":"123","DOI":"10.2214\/AJR.13.12028","volume":"203","author":"T Kaasalainen","year":"2014","unstructured":"Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M (2014) Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol 203:123\u2013130. https:\/\/doi.org\/10.2214\/AJR.13.12028","journal-title":"AJR Am J Roentgenol"},{"key":"11170_CR3","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1007\/s00247-012-2611-z","volume":"43","author":"T Kaasalainen","year":"2013","unstructured":"Kaasalainen T, Palmu K, Lampinen A, Kortesniemi M (2013) Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT-phantom study. Pediatr Radiol 43:673\u2013684. https:\/\/doi.org\/10.1007\/s00247-012-2611-z","journal-title":"Pediatr Radiol"},{"key":"11170_CR4","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.3109\/02841850903147053","volume":"50","author":"J Gudjonsdottir","year":"2009","unstructured":"Gudjonsdottir J, Svensson JR, Campling S et al (2009) Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning. Acta Radiol 50:1035\u20131041. https:\/\/doi.org\/10.3109\/02841850903147053","journal-title":"Acta Radiol"},{"key":"11170_CR5","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/j.jmir.2022.09.027","volume":"53","author":"Y Al-Hayek","year":"2022","unstructured":"Al-Hayek Y, Zheng X, Hayre C, Spuur K (2022) The influence of patient positioning on radiation dose in CT imaging: a narrative review. J Med Imaging Radiat Sci 53:737\u2013747","journal-title":"J Med Imaging Radiat Sci"},{"key":"11170_CR6","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1097\/RLI.0000000000000904","volume":"58","author":"P Manava","year":"2023","unstructured":"Manava P, Galster M, Ammon J et al (2023) Optimized camera-based patient positioning in CT: impact on radiation exposure. Invest Radiol 58:126\u2013130. https:\/\/doi.org\/10.1097\/RLI.0000000000000904","journal-title":"Invest Radiol"},{"key":"11170_CR7","doi-asserted-by":"publisher","first-page":"3093","DOI":"10.1118\/1.2748113","volume":"34","author":"T Toth","year":"2007","unstructured":"Toth T, Ge Z, Daly MP (2007) The influence of patient centering on CT dose and image noise. Med Phys 34:3093\u20133101. https:\/\/doi.org\/10.1118\/1.2748113","journal-title":"Med Phys"},{"key":"11170_CR8","doi-asserted-by":"publisher","first-page":"631","DOI":"10.3233\/XST-190491","volume":"27","author":"INC Isa","year":"2019","unstructured":"Isa INC, Rahmat SMS, Dom SM et al (2019) The effects of mis-centering on radiation dose during CT head examination: a phantom study. J Xray Sci Technol 27:631\u2013639. https:\/\/doi.org\/10.3233\/XST-190491","journal-title":"J Xray Sci Technol"},{"key":"11170_CR9","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1016\/j.acra.2019.07.004","volume":"27","author":"M Eberhard","year":"2020","unstructured":"Eberhard M, Bl\u00fcthgen C, Barth BK et al (2020) Vertical off-centering in reduced dose chest-CT: impact on effective dose and image noise values. Acad Radiol 27:508\u2013517. https:\/\/doi.org\/10.1016\/j.acra.2019.07.004","journal-title":"Acad Radiol"},{"key":"11170_CR10","doi-asserted-by":"publisher","first-page":"5697","DOI":"10.1002\/mp.12519","volume":"44","author":"N Saltybaeva","year":"2017","unstructured":"Saltybaeva N, Alkadhi H (2017) Vertical off-centering affects organ dose in chest CT: evidence from Monte Carlo simulations in anthropomorphic phantoms. Med Phys 44:5697\u20135704. https:\/\/doi.org\/10.1002\/mp.12519","journal-title":"Med Phys"},{"key":"11170_CR11","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1067\/j.cpradiol.2018.02.007","volume":"48","author":"OO Akin-Akintayo","year":"2019","unstructured":"Akin-Akintayo OO, Alexander LF, Neill R et al (2019) Prevalence and severity of off-centering during diagnostic CT: observations from 57,621 CT scans of the chest, abdomen, and\/or pelvis. Curr Probl Diagn Radiol 48:229\u2013234. https:\/\/doi.org\/10.1067\/j.cpradiol.2018.02.007","journal-title":"Curr Probl Diagn Radiol"},{"key":"11170_CR12","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/S00247-011-2154-8\/METRICS","volume":"41","author":"B Newman","year":"2011","unstructured":"Newman B, Callahan MJ (2011) ALARA (as low as reasonably achievable) CT 2011\u2014executive summary. Pediatr Radiol 41:453\u2013455. https:\/\/doi.org\/10.1007\/S00247-011-2154-8\/METRICS","journal-title":"Pediatr Radiol"},{"key":"11170_CR13","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1097\/RLI.0000000000000601","volume":"55","author":"MM Lell","year":"2020","unstructured":"Lell MM, Kachelrie\u00df M (2020) Recent and upcoming technological developments in computed tomography: high speed, low dose, deep learning, multienergy. Invest Radiol 55:8\u201319. https:\/\/doi.org\/10.1097\/RLI.0000000000000601","journal-title":"Invest Radiol"},{"key":"11170_CR14","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1097\/RLI.0b013e318169005e","volume":"43","author":"J Li","year":"2008","unstructured":"Li J, Udayasankar UK, Toth TL et al (2008) Application of automatic vertical positioning software to reduce radiation exposure in multidetector row computed tomography of the chest. Invest Radiol 43:447\u2013452. https:\/\/doi.org\/10.1097\/RLI.0b013e318169005e","journal-title":"Invest Radiol"},{"key":"11170_CR15","doi-asserted-by":"publisher","first-page":"2079","DOI":"10.1007\/s00330-018-5745-z","volume":"29","author":"R Booij","year":"2019","unstructured":"Booij R, Budde RPJ, Dijkshoorn ML, van Straten M (2019) Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. Eur Radiol 29:2079\u20132088. https:\/\/doi.org\/10.1007\/s00330-018-5745-z","journal-title":"Eur Radiol"},{"key":"11170_CR16","doi-asserted-by":"publisher","first-page":"3243","DOI":"10.1007\/s00330-023-09424-3","volume":"33","author":"Y Salimi","year":"2023","unstructured":"Salimi Y, Shiri I, Akavanallaf A et al (2023) Fully automated accurate patient positioning in computed tomography using anterior\u2013posterior localizer images and a deep neural network: a dual-center study. Eur Radiol 33:3243\u20133252. https:\/\/doi.org\/10.1007\/s00330-023-09424-3","journal-title":"Eur Radiol"},{"key":"11170_CR17","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00330-020-07097-w","volume":"31","author":"R Booij","year":"2021","unstructured":"Booij R, van Straten M, Wimmer A, Budde RPJ (2021) Automated patient positioning in CT using a 3D camera for body contour detection: accuracy in pediatric patients. Eur Radiol 31:131\u2013138. https:\/\/doi.org\/10.1007\/s00330-020-07097-w","journal-title":"Eur Radiol"},{"key":"11170_CR18","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1097\/RLI.0000000000000482","volume":"53","author":"N Saltybaeva","year":"2018","unstructured":"Saltybaeva N, Schmidt B, Wimmer A et al (2018) Precise and automatic patient positioning in computed tomography: avatar modeling of the patient surface using a 3-dimensional camera. Invest Radiol 53:641\u2013646. https:\/\/doi.org\/10.1097\/RLI.0000000000000482","journal-title":"Invest Radiol"},{"key":"11170_CR19","doi-asserted-by":"publisher","unstructured":"Dane B, O\u2019Donnell T, Liu S et al (2021) Radiation dose reduction, improved isocenter accuracy and CT scan time savings with automatic patient positioning by a 3D camera. Eur J Radiol 136:109537. https:\/\/doi.org\/10.1016\/j.ejrad.2021.109537","DOI":"10.1016\/j.ejrad.2021.109537"},{"key":"11170_CR20","doi-asserted-by":"publisher","first-page":"6049","DOI":"10.1007\/s00330-020-07629-4","volume":"31","author":"Y Gang","year":"2021","unstructured":"Gang Y, Chen X, Li H et al (2021) A comparison between manual and artificial intelligence-based automatic positioning in CT imaging for COVID-19 patients. Eur Radiol 31:6049\u20136058. https:\/\/doi.org\/10.1007\/s00330-020-07629-4","journal-title":"Eur Radiol"},{"key":"11170_CR21","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.imed.2021.04.005","volume":"1","author":"Y Gang","year":"2021","unstructured":"Gang Y, Chen X, Wang H et al (2021) Accurate and efficient pulmonary CT imaging workflow for COVID-19 patients by the combination of intelligent guided robot and automatic positioning technology. Intell Med 1:3\u20139. https:\/\/doi.org\/10.1016\/j.imed.2021.04.005","journal-title":"Intell Med"},{"key":"11170_CR22","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1111\/J.1440-1797.2010.01380.X","volume":"15","author":"LK Henderson","year":"2010","unstructured":"Henderson LK, Craig JC, Willis NS et al (2010) How to write a Cochrane systematic review. Nephrology 15:617\u2013624. https:\/\/doi.org\/10.1111\/J.1440-1797.2010.01380.X","journal-title":"Nephrology"},{"key":"11170_CR23","doi-asserted-by":"publisher","unstructured":"Page MJ, McKenzie JE, Bossuyt PM et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71. https:\/\/doi.org\/10.1136\/BMJ.N71","DOI":"10.1136\/BMJ.N71"},{"key":"11170_CR24","doi-asserted-by":"publisher","first-page":"580","DOI":"10.5195\/JMLA.2018.513","volume":"106","author":"L Kellermeyer","year":"2018","unstructured":"Kellermeyer L, Harnke B, Knight S (2018) Covidence and Rayyan. J Med Libr Assoc 106:580. https:\/\/doi.org\/10.5195\/JMLA.2018.513","journal-title":"J Med Libr Assoc"},{"key":"11170_CR25","unstructured":"Boutron I, Page MJ, Higgins JPT, Altman DG, Lundh A, Hr\u00f3bjartsson A (2024) Considering bias and conflicts of interest among the included studies. In: Higgins JPT, Thomas J, Chandler J et al (eds) Cochrane handbook for systematic reviews of interventions version 6.5. Cochrane, London. https:\/\/training.cochrane.org\/handbook\/current\/chapter-07. Accessed 24 Dec 2023"},{"key":"11170_CR26","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/acm2.12594","volume":"20","author":"I Barreto","year":"2019","unstructured":"Barreto I, Lamoureux R, Olguin C et al (2019) Impact of patient centering in CT on organ dose and the effect of using a positioning compensation system: evidence from OSLD measurements in postmortem subjects. J Appl Clin Med Phys 20:141\u2013151. https:\/\/doi.org\/10.1002\/acm2.12594","journal-title":"J Appl Clin Med Phys"},{"key":"11170_CR27","doi-asserted-by":"publisher","first-page":"524","DOI":"10.3760\/CMA.J.ISSN.0254-6450.2018.04.028","volume":"39","author":"Q Yanji","year":"2018","unstructured":"Yanji Q, Zhirong Y, Feng S, Siyan Z (2018) [Risk on bias assessment: (6) A revised tool for the quality assessment on diagnostic accuracy studies (QUADAS-2)]. Zhonghua Liu Xing Bing Xue Za Zhi 39:524\u2013531. https:\/\/doi.org\/10.3760\/CMA.J.ISSN.0254-6450.2018.04.028","journal-title":"Zhonghua Liu Xing Bing Xue Za Zhi"},{"key":"11170_CR28","unstructured":"jamovi (2017) Open statistical software for the desktop and cloud. https:\/\/www.jamovi.org\/. Accessed 24 Jan 2024"},{"key":"11170_CR29","doi-asserted-by":"publisher","unstructured":"Viechtbauer W (2005) Bias and efficiency of meta-analytic variance estimators in the random-effects model. J Educ Behav Stat 30:261\u2013293. https:\/\/doi.org\/10.3102\/10769986030003261","DOI":"10.3102\/10769986030003261"},{"key":"11170_CR30","doi-asserted-by":"publisher","first-page":"101","DOI":"10.2307\/3001666","volume":"10","author":"WG Cochran","year":"1954","unstructured":"Cochran WG (1954) The combination of estimates from different experiments. Biometrics 10:101. https:\/\/doi.org\/10.2307\/3001666","journal-title":"Biometrics"},{"key":"11170_CR31","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/J.RADI.2024.04.016","volume":"30","author":"R Nelson","year":"2024","unstructured":"Nelson R, Harkin S, Iball G (2024) Use of a 3D camera for automated patient positioning for chest-abdomen-pelvis CT scans: effect on positioning accuracy and patient dose. Radiography 30:1060\u20131067. https:\/\/doi.org\/10.1016\/J.RADI.2024.04.016","journal-title":"Radiography"},{"key":"11170_CR32","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-92637-7","volume":"11","author":"J Greffier","year":"2021","unstructured":"Greffier J, Frandon J, de Forges H et al (2021) Impact of additional mattresses in emergency CT on the automated patient centering proposed by a 3D camera: a phantom study. Sci Rep 11:13191. https:\/\/doi.org\/10.1038\/s41598-021-92637-7","journal-title":"Sci Rep"},{"key":"11170_CR33","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1007\/S00330-021-08191-3\/TABLES\/1","volume":"32","author":"R Booij","year":"2022","unstructured":"Booij R, van Straten M, Wimmer A, Budde RPJ (2022) Influence of breathing state on the accuracy of automated patient positioning in thoracic CT using a 3D camera for body contour detection. Eur Radiol 32:442\u2013447. https:\/\/doi.org\/10.1007\/S00330-021-08191-3\/TABLES\/1","journal-title":"Eur Radiol"},{"key":"11170_CR34","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1542\/PEDS.2007-1910","volume":"120","author":"AS Brody","year":"2007","unstructured":"Brody AS, Frush DP, Huda W et al (2007) Radiation risk to children from computed tomography. Pediatrics 120:677\u2013682. https:\/\/doi.org\/10.1542\/PEDS.2007-1910","journal-title":"Pediatrics"},{"key":"11170_CR35","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/jmrs.535","volume":"69","author":"Y Al-Hayek","year":"2022","unstructured":"Al-Hayek Y, Zheng X, Davidson R et al (2022) 0\u00b0 vs. 180\u00b0 CT localiser: the effect of vertical off-centring, phantom positioning and tube voltage on dose optimisation in multidetector computed tomography. J Med Radiat Sci 69:5\u201312. https:\/\/doi.org\/10.1002\/jmrs.535","journal-title":"J Med Radiat Sci"},{"key":"11170_CR36","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.ejro.2018.12.001","volume":"6","author":"T Kaasalainen","year":"2019","unstructured":"Kaasalainen T, M\u00e4kel\u00e4 T, Kortesniemi M (2019) The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT: a preliminary phantom study on two different CT equipments. Eur J Radiol Open 6:24\u201332. https:\/\/doi.org\/10.1016\/j.ejro.2018.12.001","journal-title":"Eur J Radiol Open"},{"key":"11170_CR37","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.ejmp.2011.06.002","volume":"28","author":"MA Habibzadeh","year":"2012","unstructured":"Habibzadeh MA, Ay MR, Asl ARK et al (2012) Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies. Phys Med 28:191\u2013199. https:\/\/doi.org\/10.1016\/j.ejmp.2011.06.002","journal-title":"Phys Med"},{"key":"11170_CR38","doi-asserted-by":"publisher","first-page":"20140730","DOI":"10.1259\/bjr.20140730","volume":"88","author":"JW Lambert","year":"2015","unstructured":"Lambert JW, Kumar S, Chen JS et al (2015) Investigating the CT localizer radiograph: acquisition parameters, patient centring and their combined influence on radiation dose. Br J Radiol 88:20140730. https:\/\/doi.org\/10.1259\/bjr.20140730","journal-title":"Br J Radiol"},{"key":"11170_CR39","doi-asserted-by":"publisher","first-page":"e0195807","DOI":"10.1371\/JOURNAL.PONE.0195807","volume":"13","author":"YJ Ryu","year":"2018","unstructured":"Ryu YJ, Choi YH, Cheon JE et al (2018) Effect of arm position, presence of medical devices, and off-centering during acquisition of scout image on automatic tube voltage selection and current modulation in pediatric chest CT. PLoS One 13:e0195807. https:\/\/doi.org\/10.1371\/JOURNAL.PONE.0195807","journal-title":"PLoS One"},{"key":"11170_CR40","doi-asserted-by":"publisher","first-page":"6790","DOI":"10.1007\/s00330-019-06330-5","volume":"29","author":"A Euler","year":"2019","unstructured":"Euler A, Saltybaeva N, Alkadhi H (2019) How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT. Eur Radiol 29:6790\u20136793. https:\/\/doi.org\/10.1007\/s00330-019-06330-5","journal-title":"Eur Radiol"},{"key":"11170_CR41","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/s42058-020-00023-5","volume":"3","author":"X Ding","year":"2020","unstructured":"Ding X, Tan W, Yang S et al (2020) How table height influences image quality and radiation dose of chest CT scans with automatic exposure control: a phantom study? Chin J Acad Radiol 3:35\u201340. https:\/\/doi.org\/10.1007\/s42058-020-00023-5","journal-title":"Chin J Acad Radiol"},{"key":"11170_CR42","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.jmir.2016.05.002","volume":"47","author":"H Almohiy","year":"2016","unstructured":"Almohiy H, Alasar EMM, Saade C (2016) Correct patient centering increases image quality without concomitant increase of radiation dose during adult intracranial computed tomography. J Med Imaging Radiat Sci 47:235\u2013242. https:\/\/doi.org\/10.1016\/j.jmir.2016.05.002","journal-title":"J Med Imaging Radiat Sci"},{"key":"11170_CR43","doi-asserted-by":"crossref","unstructured":"Afrieda N, Anam C, Setia Budi W, Dougherty G (2020) Automated patient position in CT examination using a Kinect camera. J Phys Conf Ser 1505:012034","DOI":"10.1088\/1742-6596\/1505\/1\/012034"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-11170-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-024-11170-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-024-11170-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T07:08:34Z","timestamp":1747292914000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-024-11170-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,21]]},"references-count":43,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,6]]}},"alternative-id":["11170"],"URL":"https:\/\/doi.org\/10.1007\/s00330-024-11170-z","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,21]]},"assertion":[{"value":"13 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 November 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Professor Mark McEntee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No complex statistical methods were necessary for this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was not required for this study because it is a systematic review and meta-analysis.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was not required because it is a systematic review and meta-analysis.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"We did not identify any direct overlap in the subjects or cohorts among the included studies.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}