{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T09:10:39Z","timestamp":1780391439756,"version":"3.54.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T00:00:00Z","timestamp":1746576000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T00:00:00Z","timestamp":1746576000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-025-11624-y","type":"journal-article","created":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T11:58:03Z","timestamp":1746619083000},"page":"7235-7243","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Can a low b-value diffusion-weighted imaging sequence replace the standard T2-weighted fluid-sensitive sequence in breast MRI? A single-center prospective study"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-5458-7183","authenticated-orcid":false,"given":"Jason","family":"Gatewood","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Peterson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allison","family":"Aripoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashley","family":"Huppe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Onalisa","family":"Winblad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carissa","family":"Walter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kate","family":"Young","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanming","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauren","family":"Clark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vibhas","family":"Deshpande","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Itriago","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katja","family":"Pinker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,7]]},"reference":[{"key":"11624_CR1","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1097\/RLI.0b013e3181f3fcdf","volume":"46","author":"F Sardanelli","year":"2011","unstructured":"Sardanelli F, Podo F, Santoro F et al (2011) Multicenter surveillance of women at high genetic breast cancer risk using mammography, ultrasonography, and contrast-enhanced magnetic resonance imaging (the high breast cancer risk Italian 1 study): final results. Invest Radiol 46:94\u2013105","journal-title":"Invest Radiol"},{"key":"11624_CR2","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1007\/s00330-011-2238-8","volume":"22","author":"MN Plana","year":"2012","unstructured":"Plana MN, Carreira C, Muriel A et al (2012) Magnetic resonance imaging in the preoperative assessment of patients with primary breast cancer: systematic review of diagnostic accuracy and meta-analysis. Eur Radiol 22:26\u201338","journal-title":"Eur Radiol"},{"key":"11624_CR3","doi-asserted-by":"publisher","first-page":"5640","DOI":"10.1200\/JCO.2008.21.5756","volume":"27","author":"ME Brennan","year":"2009","unstructured":"Brennan ME, Houssami N, Lord S et al (2009) Magnetic resonance imaging screening of the contralateral breast in women with newly diagnosed breast cancer: systematic review and meta-analysis of incremental cancer detection and impact on surgical management. J Clin Oncol 27:5640\u20135649","journal-title":"J Clin Oncol"},{"key":"11624_CR4","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1245\/s10434-010-1236-4","volume":"17","author":"L Elmore","year":"2010","unstructured":"Elmore L, Margenthaler JA (2010) Use of breast MRI surveillance in women at high risk for breast cancer: a single-institutional experience. Ann Surg Oncol 17:263\u2013267","journal-title":"Ann Surg Oncol"},{"key":"11624_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1002\/jso.20350","volume":"92","author":"CD Lehman","year":"2005","unstructured":"Lehman CD, Blume JD, Thickman D et al (2005) Added cancer yield of MRI in screening the contralateral breast of women recently diagnosed with breast cancer: results from the International Breast Magnetic Resonance Consortium (IBMC) trial. J Surg Oncol 92:9\u201315","journal-title":"J Surg Oncol"},{"key":"11624_CR6","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1001\/jama.2020.0572","volume":"323","author":"CE Comstock","year":"2020","unstructured":"Comstock CE, Gatsonis C, Newstead GM et al (2020) Comparison of abbreviated breast MRI vs digital breast tomosynthesis for breast cancer detection among women with dense breasts undergoing screening. JAMA 323:746\u2013756","journal-title":"JAMA"},{"key":"11624_CR7","doi-asserted-by":"publisher","first-page":"1716","DOI":"10.2214\/AJR.08.2139","volume":"193","author":"SC Partridge","year":"2009","unstructured":"Partridge SC, DeMartini WB, Kurland BF, Eby PR, White SW, Lehman CD (2009) Quantitative diffusion-weighted imaging as an adjunct to conventional breast MRI for improved positive predictive value. AJR Am J Roentgenol 193:1716\u20131722","journal-title":"AJR Am J Roentgenol"},{"key":"11624_CR8","doi-asserted-by":"publisher","first-page":"e305","DOI":"10.1016\/j.clbc.2017.06.011","volume":"18","author":"RY Shi","year":"2018","unstructured":"Shi RY, Yao QY, Wu LM, Xu JR (2018) Breast lesions: diagnosis using diffusion weighted imaging at 1.5T and 3.0T\u2014systematic review and meta-analysis. Clin Breast Cancer 18:e305\u2013e320","journal-title":"Clin Breast Cancer"},{"key":"11624_CR9","doi-asserted-by":"publisher","first-page":"1756","DOI":"10.1158\/1078-0432.CCR-18-2967","volume":"25","author":"H Rahbar","year":"2019","unstructured":"Rahbar H, Zhang Z, Chenevert TL et al (2019) Utility of diffusion-weighted imaging to decrease unnecessary biopsies prompted by breast MRI: a trial of the ECOG-ACRIN Cancer Research Group (A6702). Clin Cancer Res 25:1756\u20131765","journal-title":"Clin Cancer Res"},{"key":"11624_CR10","doi-asserted-by":"publisher","first-page":"6588","DOI":"10.1007\/s00330-022-08833-0","volume":"32","author":"R Lo Gullo","year":"2022","unstructured":"Lo Gullo R, Sevilimedu V, Baltzer P et al (2022) A survey by the European Society of Breast Imaging on the implementation of breast diffusion-weighted imaging in clinical practice. Eur Radiol 32:6588\u20136597","journal-title":"Eur Radiol"},{"key":"11624_CR11","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1002\/mrm.22024","volume":"62","author":"DA Porter","year":"2009","unstructured":"Porter DA, Heidemann RM (2009) High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn Reson Med 62:468\u2013475","journal-title":"Magn Reson Med"},{"key":"11624_CR12","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1093\/jbi\/wbaa103","volume":"3","author":"JG Whisenant","year":"2021","unstructured":"Whisenant JG, Romanoff J, Rahbar H et al (2021) Factors affecting image quality and lesion evaluability in breast diffusion-weighted MRI: observations from the ECOG-ACRIN Cancer Research Group Multisite Trial (A6702). J Breast Imaging 3:44\u201356","journal-title":"J Breast Imaging"},{"key":"11624_CR13","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1148\/radiol.12111494","volume":"263","author":"W Bogner","year":"2012","unstructured":"Bogner W, Pinker-Domenig K, Bickel H et al (2012) Readout-segmented echo-planar imaging improves the diagnostic performance of diffusion-weighted MR breast examinations at 3.0 T. Radiology 263:64\u201376","journal-title":"Radiology"},{"key":"11624_CR14","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.ejrad.2015.10.009","volume":"85","author":"L Filli","year":"2016","unstructured":"Filli L, Ghafoor S, Kenkel D et al (2016) Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast. Eur J Radiol 85:274\u2013278","journal-title":"Eur J Radiol"},{"key":"11624_CR15","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1148\/radiol.2541090953","volume":"254","author":"WA Berg","year":"2010","unstructured":"Berg WA, Blume JD, Adams AM et al (2010) Reasons women at elevated risk of breast cancer refuse breast MR imaging screening: ACRIN 6666. Radiology 254:79\u201387","journal-title":"Radiology"},{"key":"11624_CR16","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.jacr.2023.04.002","volume":"20","author":"DL Monticciolo","year":"2023","unstructured":"Monticciolo DL, Newell MS, Moy L, Lee CS, Destounis SV (2023) Breast cancer screening for women at higher-than-average risk: updated recommendations from the ACR. J Am Coll Radiol 20:902\u2013914","journal-title":"J Am Coll Radiol"},{"key":"11624_CR17","doi-asserted-by":"publisher","first-page":"4036","DOI":"10.1007\/s00330-022-08617-6","volume":"32","author":"RM Mann","year":"2022","unstructured":"Mann RM, Athanasiou A, Baltzer PAT et al (2022) Breast cancer screening in women with extremely dense breasts recommendations of the European Society of Breast Imaging (EUSOBI). Eur Radiol 32:4036\u20134045","journal-title":"Eur Radiol"},{"key":"11624_CR18","doi-asserted-by":"publisher","first-page":"e216","DOI":"10.1002\/jmri.26334","volume":"49","author":"VL Mango","year":"2019","unstructured":"Mango VL, Goel A, Mema E, Kwak E, Ha R (2019) Breast MRI screening for average-risk women: a Monte Carlo simulation cost-benefit analysis. J Magn Reson Imaging 49:e216\u2013e221","journal-title":"J Magn Reson Imaging"},{"key":"11624_CR19","doi-asserted-by":"publisher","first-page":"1476","DOI":"10.1093\/jnci\/djab119","volume":"113","author":"HA Geuzinge","year":"2021","unstructured":"Geuzinge HA, Bakker MF, Heijnsdijk EAM et al (2021) Cost-effectiveness of magnetic resonance imaging screening for women with extremely dense breast tissue. J Natl Cancer Inst 113:1476\u20131483","journal-title":"J Natl Cancer Inst"},{"key":"11624_CR20","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1148\/radiol.15141905","volume":"276","author":"K Pinker","year":"2015","unstructured":"Pinker K, Baltzer P, Bogner W et al (2015) Multiparametric MR imaging with high-resolution dynamic contrast-enhanced and diffusion-weighted imaging at 7 T improves the assessment of breast tumors: a feasibility study. Radiology 276:360\u2013370","journal-title":"Radiology"},{"key":"11624_CR21","unstructured":"Albus K (2023) MRI exam-specific parameters: breast (Revised 2-24-2023). Available via https:\/\/accreditationsupport.acr.org\/support\/solutions\/articles\/11000114407-mri-exam-specific-parameters-breast-revised-2-24-2023. Accessed 15 Apr 2024"},{"key":"11624_CR22","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1148\/radiology.211.1.r99ap38101","volume":"211","author":"CK Kuhl","year":"1999","unstructured":"Kuhl CK, Mielcareck P, Klaschik S et al (1999) Dynamic breast MR imaging: are signal intensity time course data useful for differential diagnosis of enhancing lesions? Radiology 211:101\u2013110","journal-title":"Radiology"},{"key":"11624_CR23","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","volume":"42","author":"PA Harris","year":"2009","unstructured":"Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG (2009) Research electronic data capture (REDCap)\u2014a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inf 42:377\u2013381","journal-title":"J Biomed Inf"},{"key":"11624_CR24","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1002\/cjs.5550360306","volume":"36","author":"KP Nelson","year":"2008","unstructured":"Nelson KP, Edwards D (2008) On population-based measures of agreement for binary classifications. Can J Stat 36:411\u2013426","journal-title":"Can J Stat"},{"key":"11624_CR25","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1002\/jmri.26285","volume":"49","author":"M Zhang","year":"2019","unstructured":"Zhang M, Horvat JV, Bernard-Davila B et al (2019) Multiparametric MRI model with dynamic contrast-enhanced and diffusion-weighted imaging enables breast cancer diagnosis with high accuracy. J Magn Reson Imaging 49:864\u2013874","journal-title":"J Magn Reson Imaging"},{"key":"11624_CR26","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1148\/radiol.2463070432","volume":"246","author":"T Parikh","year":"2008","unstructured":"Parikh T, Drew SJ, Lee VS et al (2008) Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imaging. Radiology 246:812\u2013822","journal-title":"Radiology"},{"key":"11624_CR27","doi-asserted-by":"publisher","first-page":"1299","DOI":"10.1007\/s00247-019-04455-9","volume":"49","author":"ADI Grasparil","year":"2019","unstructured":"Grasparil ADI, Gupta H, Sheybani E, Chavhan GB (2019) Low b-value (50-100) diffusion-weighted images detect significantly more hyperintense liver lesions in children than T2-weighted images. Pediatr Radiol 49:1299\u20131305","journal-title":"Pediatr Radiol"},{"key":"11624_CR28","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1093\/jbi\/wbac048","volume":"4","author":"LJ Grimm","year":"2022","unstructured":"Grimm LJ, Conant EF, Dialani VM et al (2022) Abbreviated breast MRI utilization: a survey of the Society of Breast Imaging. J Breast Imaging 4:506\u2013512","journal-title":"J Breast Imaging"},{"key":"11624_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.110948","volume":"166","author":"D Wessling","year":"2023","unstructured":"Wessling D, Gassenmaier S, Olthof SC et al (2023) Novel deep-learning-based diffusion weighted imaging sequence in 1.5 T breast MRI. Eur J Radiol 166:110948","journal-title":"Eur J Radiol"},{"key":"11624_CR30","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1097\/RLI.0000000000000999","volume":"58","author":"KJJ van der Hoogt","year":"2023","unstructured":"van der Hoogt KJJ, Schipper RJ, Wessels R, Ter Beek LC, Beets-Tan RGH, Mann RM (2023) Breast DWI analyzed before and after gadolinium contrast administration\u2014an intrapatient analysis on 1.5 T and 3.0 T. Invest Radiol 58:832\u2013841","journal-title":"Invest Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-11624-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-025-11624-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-11624-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T11:03:07Z","timestamp":1761908587000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-025-11624-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,7]]},"references-count":30,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["11624"],"URL":"https:\/\/doi.org\/10.1007\/s00330-025-11624-y","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,7]]},"assertion":[{"value":"2 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is author Carissa Walter.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: K.P. declares the following speakers bureaus and consultancies: European Society of Breast Imaging (active), Bayer (active), Guerbet (active), Neodynamics (ended), AURA Health Technologies GmbH (active), FocusWest Health (active). These companies had no role in study design, data collection, data analysis, data interpretation, or writing of the report. K.P. is also a member of the Scientific Editorial Board (section: Breast) of\n                      European Radiology\n                      . As such, they have not participated in the selection or review processes for this article. P.I. and V.D. are employees of Siemens. Their role in this study was to load the diffusion research protocol onto the MRI machines with scanning parameters and to edit the methods section. They were not involved in study design, data collection, data analysis, or data interpretation. The remaining authors declare no conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The author Kate Young provided statistical advice for this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"No study subjects or cohorts have been previously reported.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}