{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T16:31:42Z","timestamp":1779121902234,"version":"3.51.4"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T00:00:00Z","timestamp":1764201600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T00:00:00Z","timestamp":1764201600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-025-12170-3","type":"journal-article","created":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T15:48:15Z","timestamp":1764258495000},"page":"3638-3647","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparing multi-use syringeless and conventional single-use dual-syringe injectors in contrast-enhanced CT: efficiency, cost, and technologist satisfaction"],"prefix":"10.1007","volume":"36","author":[{"given":"Arash","family":"Mahdavi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gulnoor","family":"Sheriff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"McKinney","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Negar","family":"Firoozeh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Watt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Achille","family":"Mileto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8522-1018","authenticated-orcid":false,"given":"Dushyant","family":"Sahani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,27]]},"reference":[{"key":"12170_CR1","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/5164970","volume":"2022","author":"S Hussain","year":"2022","unstructured":"Hussain S, Mubeen I, Ullah N et al (2022) Modern diagnostic imaging technique applications and risk factors in the medical field: a review. Biomed Res Int 2022:5164970","journal-title":"Biomed Res Int"},{"key":"12170_CR2","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1001\/jama.2019.11456","volume":"322","author":"R Smith-Bindman","year":"2019","unstructured":"Smith-Bindman R, Kwan ML, Marlow EC et al (2019) Trends in use of medical imaging in US health care systems and in Ontario, Canada, 2000\u20132016. JAMA 322:843\u2013856","journal-title":"JAMA"},{"key":"12170_CR3","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1148\/radiol.2272020617","volume":"227","author":"AJ Maitino","year":"2003","unstructured":"Maitino AJ, Levin DC, Parker L, Rao VM, Sunshine JH (2003) Nationwide trends in rates of utilization of noninvasive diagnostic imaging among the Medicare population between 1993 and 1999. Radiology 227:113\u2013117","journal-title":"Radiology"},{"key":"12170_CR4","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/j.annemergmed.2011.05.020","volume":"58","author":"KE Kocher","year":"2011","unstructured":"Kocher KE, Meurer WJ, Fazel R, Scott PA, Krumholz HM, Nallamothu BK (2011) National trends in use of computed tomography in the emergency department. Ann Emerg Med 58:452\u201362.e3","journal-title":"Ann Emerg Med"},{"key":"12170_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2024.110088","volume":"107","author":"JW Goldfarb","year":"2024","unstructured":"Goldfarb JW, Mossa-Basha M, Nguyen KL, Hecht EM, Finn JP (2024) Trends in magnetic resonance and computed tomography angiography utilization among Medicare beneficiaries between 2013 and 2020. Clin Imaging 107:110088","journal-title":"Clin Imaging"},{"key":"12170_CR6","doi-asserted-by":"publisher","first-page":"6","DOI":"10.37549\/AR2291","volume":"45","author":"JR Grajo","year":"2016","unstructured":"Grajo JR, Patino M, Prochowski A, Sahani DV (2016) Dual energy CT in practice: basic principles and applications. Appl Radiol 45:6\u201312","journal-title":"Appl Radiol"},{"key":"12170_CR7","doi-asserted-by":"crossref","unstructured":"Zhou W, Abdurakhimova D, Bruesewitz M, Halaweish A, McCollough CH, Leng S (2018) Impact of photon counting detector technology on kV selection and diagnostic workflow in CT. Proc SPIE Int Soc Opt Eng 10573:105731C","DOI":"10.1117\/12.2294952"},{"key":"12170_CR8","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jacr.2005.10.008","volume":"3","author":"GW Boland","year":"2006","unstructured":"Boland GW (2006) Stakeholder expectations for radiologists: obstacles or opportunities. J Am Coll Radiol 3:156\u2013163","journal-title":"J Am Coll Radiol"},{"key":"12170_CR9","first-page":"231","volume":"9","author":"M Friebe","year":"2016","unstructured":"Friebe M (2016) Computed tomography and magnetic resonance imaging contrast media injectors: technical feature review\u2014what is really needed. Med Devices (Auckl) 9:231\u2013239","journal-title":"Med Devices (Auckl)"},{"key":"12170_CR10","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1148\/radiol.10090908","volume":"256","author":"KT Bae","year":"2010","unstructured":"Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32\u201361","journal-title":"Radiology"},{"key":"12170_CR11","first-page":"344","volume":"90","author":"A Chaya","year":"2019","unstructured":"Chaya A, Jost G, Endrikat J (2019) Piston-based vs peristaltic pump-based CT injector systems. Radiol Technol 90:344\u2013352","journal-title":"Radiol Technol"},{"key":"12170_CR12","doi-asserted-by":"publisher","first-page":"W226","DOI":"10.2214\/AJR.10.5924","volume":"197","author":"B Buerke","year":"2011","unstructured":"Buerke B, Puesken M, Mellmann A et al (2011) Automatic MDCT injectors: hygiene and efficiency of disposable, prefilled, and multidosing roller pump systems in clinical routine. AJR Am J Roentgenol 197:W226\u2013W232","journal-title":"AJR Am J Roentgenol"},{"key":"12170_CR13","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.jacr.2012.04.007","volume":"9","author":"X Ma","year":"2012","unstructured":"Ma X, Singh A, Fay J, Boland G, Sahani DV (2012) Comparison of dual-syringe and syringeless power injectors in outpatient MDCT practice: impact on the operator\u2019s performance, CT workflow, and operation cost. J Am Coll Radiol 9:578\u2013582","journal-title":"J Am Coll Radiol"},{"key":"12170_CR14","doi-asserted-by":"publisher","first-page":"3","DOI":"10.2214\/AJR.07.3208","volume":"191","author":"GW Boland","year":"2008","unstructured":"Boland GW (2008) Enhancing CT productivity: strategies for increasing capacity. AJR Am J Roentgenol 191:3\u201310","journal-title":"AJR Am J Roentgenol"},{"key":"12170_CR15","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1016\/j.rcl.2023.05.002","volume":"61","author":"R Chung","year":"2023","unstructured":"Chung R, Dane B, Yeh BM, Morgan DE, Sahani DV, Kambadakone A (2023) Dual-energy computed tomography: technological considerations. Radiol Clin North Am 61:945\u2013961","journal-title":"Radiol Clin North Am"},{"key":"12170_CR16","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1002\/acm2.13098","volume":"22","author":"JE Browne","year":"2021","unstructured":"Browne JE, Bruesewitz MR, Thomas V et al (2021) Procedure for optimal implementation of automatic tube potential selection in pediatric CT to reduce radiation dose and improve workflow. J Appl Clin Med Phys 22:194\u2013202","journal-title":"J Appl Clin Med Phys"},{"key":"12170_CR17","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1055\/a-2119-5802","volume":"196","author":"F Hagen","year":"2024","unstructured":"Hagen F, Soschynski M, Weis M et al (2024) Photon-counting computed tomography\u2014clinical application in oncological, cardiovascular, and pediatric radiology. Rofo 196:25\u201335","journal-title":"Rofo"},{"key":"12170_CR18","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1148\/rg.322115128","volume":"32","author":"JB Kruskal","year":"2012","unstructured":"Kruskal JB, Reedy A, Pascal L, Rosen MP, Boiselle PM (2012) Quality initiatives: lean approach to improving performance and efficiency in a radiology department. Radiographics 32:573\u2013587","journal-title":"Radiographics"},{"key":"12170_CR19","doi-asserted-by":"publisher","first-page":"169","DOI":"10.2147\/MDER.S51757","volume":"6","author":"GL Colombo","year":"2013","unstructured":"Colombo GL, Andreis IA, Di Matteo S, Bruno GM, Mondellini C (2013) Syringeless power injector versus dual-syringe power injector: economic evaluation of user performance, the impact on contrast enhanced computed tomography (CECT) workflow exams, and hospital costs. Med Devices 6:169\u2013174","journal-title":"Med Devices"},{"key":"12170_CR20","doi-asserted-by":"publisher","first-page":"E81","DOI":"10.1148\/rg.2021200107","volume":"41","author":"P Rachh","year":"2021","unstructured":"Rachh P, Pendley AM, Duong P-AT, Hanna TN, Heilbrun ME (2021) Decreasing CT acquisition time in the emergency department through lean management principles. Radiographics 41:E81\u2013E89","journal-title":"Radiographics"},{"key":"12170_CR21","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.2214\/AJR.13.11281","volume":"201","author":"EV Lang","year":"2013","unstructured":"Lang EV, Yuh WTC, Ajam A et al (2013) Understanding patient satisfaction ratings for radiology services. AJR Am J Roentgenol 201:1190\u20131196","journal-title":"AJR Am J Roentgenol"},{"key":"12170_CR22","unstructured":"American Society of Radiologic Technologists (ASRT) (2023) Radiologic sciences workplace and staffing survey. Available via https:\/\/www.asrt.org\/main\/news-publications\/research\/staffing-surveys?_ga=2.82916050.573474611.1718747517-1916857503.1718747517. Accessed 23 Jan 2024"},{"key":"12170_CR23","doi-asserted-by":"crossref","unstructured":"Toia GV, Rose SD, Brown Z et al (2023) Consumable material waste and workflow efficiency comparison between multi-use syringeless and single-use syringe-based injectors in computed tomography. Acad Radiol 30:2340\u20132349","DOI":"10.1016\/j.acra.2023.05.038"},{"key":"12170_CR24","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1016\/j.radi.2023.09.006","volume":"29","author":"MNK Anudjo","year":"2023","unstructured":"Anudjo MNK, Vitale C, Elshami W et al (2023) Considerations for environmental sustainability in clinical radiology and radiotherapy practice: a systematic literature review and recommendations for a greener practice. Radiography 29:1077\u20131092","journal-title":"Radiography"},{"key":"12170_CR25","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13244-022-01175-x","volume":"13","author":"HM Dekker","year":"2022","unstructured":"Dekker HM, Stroomberg GJ, Prokop M (2022) Tackling the increasing contamination of the water supply by iodinated contrast media. Insights Imaging 13:30","journal-title":"Insights Imaging"},{"key":"12170_CR26","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1001\/jama.2022.9879","volume":"328","author":"MS Davenport","year":"2022","unstructured":"Davenport MS, Chu P, Szczykutowicz TP, Smith-Bindman R (2022) Comparison of strategies to conserve iodinated intravascular contrast media for computed tomography during a shortage. JAMA 328:476\u2013478","journal-title":"JAMA"},{"key":"12170_CR27","doi-asserted-by":"publisher","first-page":"666","DOI":"10.2214\/AJR.22.27969","volume":"219","author":"JJ Cavallo","year":"2022","unstructured":"Cavallo JJ, Pahade JK (2022) Practice management strategies for imaging facilities facing an acute iodinated contrast media shortage. AJR Am J Roentgenol 219:666\u2013670","journal-title":"AJR Am J Roentgenol"},{"key":"12170_CR28","doi-asserted-by":"publisher","first-page":"87","DOI":"10.11124\/JBISRIR-2017-003348","volume":"16","author":"S Ding","year":"2018","unstructured":"Ding S, Meystre NR, Campeanu C, Gullo G (2018) Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions. JBI Database Syst Rev Implement Rep 16:87\u2013116","journal-title":"JBI Database Syst Rev Implement Rep"},{"key":"12170_CR29","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190868","volume":"93","author":"M McDermott","year":"2020","unstructured":"McDermott M, Kemper C, Barone W, Jost G, Endrikat J (2020) Impact of CT injector technology and contrast media viscosity on vascular enhancement: evaluation in a circulation phantom. Br J Radiol 93:20190868","journal-title":"Br J Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-12170-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-025-12170-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-12170-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T11:23:34Z","timestamp":1776338614000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-025-12170-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,27]]},"references-count":29,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["12170"],"URL":"https:\/\/doi.org\/10.1007\/s00330-025-12170-3","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,27]]},"assertion":[{"value":"4 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Dushyant Sahani.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: GE HealthCare.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Statistical analyses were performed by our statistician, Charles Watt, MS, at the University of Washington. He has been added as one of the authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Written informed consent was waived by the Institutional Review Board (IRB).","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Institutional Review Board approval was obtained.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Study subjects or cohorts have not been previously reported.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}