{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:03:16Z","timestamp":1789689796265,"version":"4.0.1"},"reference-count":81,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T00:00:00Z","timestamp":1766102400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T00:00:00Z","timestamp":1766102400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-025-12229-1","type":"journal-article","created":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T12:25:20Z","timestamp":1766147120000},"page":"3879-3889","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Photon-counting CT in neuroradiology: a comprehensive SWOT analysis"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7200-5028","authenticated-orcid":false,"given":"Teodoro","family":"Mart\u00edn-Noguerol","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elo\u00edsa","family":"Santos-Armentia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daphne","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix E.","family":"Diehn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy J.","family":"Amrhein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Luna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,19]]},"reference":[{"key":"12229_CR1","doi-asserted-by":"crossref","unstructured":"La PJ, Das M (2024) Photon counting: detectors and applications. J Med Imaging 11:12801","DOI":"10.1117\/1.JMI.11.S1.S12801"},{"key":"12229_CR2","doi-asserted-by":"publisher","unstructured":"Klempka A, Schr\u00f6der A, Neumayer P et al (2024) Cranial computer tomography with photon counting and energy-integrated detectors: objective comparison in the same patients. Diagnostics (Basel). https:\/\/doi.org\/10.3390\/diagnostics14101019","DOI":"10.3390\/diagnostics14101019"},{"key":"12229_CR3","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.diii.2024.09.002","volume":"106","author":"J Greffier","year":"2024","unstructured":"Greffier J, Viry A, Robert A et al (2024) Photon-counting CT systems: a technical review of current clinical possibilities. Diagn Interv Imaging 106:53\u201359. https:\/\/doi.org\/10.1016\/j.diii.2024.09.002","journal-title":"Diagn Interv Imaging"},{"key":"12229_CR4","doi-asserted-by":"publisher","unstructured":"van der Bie J, van der Laan T, van Straten M et al (2025) Photon-counting CT: an updated review of clinical results. Eur J Radiol. https:\/\/doi.org\/10.1016\/j.ejrad.2025.112189","DOI":"10.1016\/j.ejrad.2025.112189"},{"key":"12229_CR5","doi-asserted-by":"publisher","first-page":"e222432","DOI":"10.1148\/radiol.222432","volume":"309","author":"PC Douek","year":"2023","unstructured":"Douek PC, Boccalini S, Oei EHG et al (2023) Clinical applications of photon-counting CT: a review of pioneer studies and a glimpse into the future. Radiology 309:e222432","journal-title":"Radiology"},{"key":"12229_CR6","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1093\/bjr\/tqae058","volume":"97","author":"AA Madhavan","year":"2024","unstructured":"Madhavan AA, Bathla G, Benson JC et al (2024) High yield clinical applications for photon counting CT in neurovascular imaging. Br J Radiol 97:894\u2013901. https:\/\/doi.org\/10.1093\/bjr\/tqae058","journal-title":"Br J Radiol"},{"key":"12229_CR7","doi-asserted-by":"publisher","unstructured":"Hiwatashi A, Nakashima M, Matsumoto K et al (2025) Neuro applications of photon-counting CT. Br J Radiol. https:\/\/doi.org\/10.1093\/bjr\/tqaf082","DOI":"10.1093\/bjr\/tqaf082"},{"key":"12229_CR8","doi-asserted-by":"publisher","first-page":"5321","DOI":"10.1007\/s00330-023-09545-9","volume":"33","author":"CH McCollough","year":"2023","unstructured":"McCollough CH, Rajendran K, Leng S et al (2023) The technical development of photon-counting detector CT. Eur Radiol 33:5321\u20135330","journal-title":"Eur Radiol"},{"key":"12229_CR9","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1007\/s11604-022-01367-x","volume":"41","author":"Y Nakamura","year":"2023","unstructured":"Nakamura Y, Higaki T, Kondo S et al (2023) An introduction to photon-counting detector CT (PCD CT) for radiologists. Jpn J Radiol 41:266\u2013282","journal-title":"Jpn J Radiol"},{"key":"12229_CR10","doi-asserted-by":"publisher","first-page":"551","DOI":"10.2214\/AJR.22.28418","volume":"220","author":"FI Baffour","year":"2023","unstructured":"Baffour FI, Glazebrook KN, Ferrero A et al (2023) Photon-counting detector CT for musculoskeletal imaging: a clinical perspective. AJR Am J Roentgenol 220:551\u2013561. https:\/\/doi.org\/10.2214\/AJR.22.28418","journal-title":"AJR Am J Roentgenol"},{"key":"12229_CR11","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1097\/RCT.0000000000001464","volume":"47","author":"JR Rajagopal","year":"2023","unstructured":"Rajagopal JR, Schwartz FR, Solomon JB et al (2023) High spatial-resolution skull base imaging with photon-counting computed tomography and energy-integrating computed tomography: a comparative phantom study. J Comput Assist Tomogr 47:613\u2013620. https:\/\/doi.org\/10.1097\/RCT.0000000000001464","journal-title":"J Comput Assist Tomogr"},{"key":"12229_CR12","doi-asserted-by":"publisher","first-page":"2930","DOI":"10.1007\/s00330-021-08441-4","volume":"32","author":"SJ Bette","year":"2022","unstructured":"Bette SJ, Braun FM, Haerting M et al (2022) Visualization of bone details in a novel photon-counting dual-source CT scanner\u2014comparison with energy-integrating CT. Eur Radiol 32:2930\u20132936. https:\/\/doi.org\/10.1007\/s00330-021-08441-4","journal-title":"Eur Radiol"},{"key":"12229_CR13","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1007\/s11604-023-01485-0","volume":"42","author":"Y Takahashi","year":"2024","unstructured":"Takahashi Y, Higaki F, Sugaya A et al (2024) Evaluation of the ear ossicles with photon-counting detector CT. Jpn J Radiol 42:158\u2013164. https:\/\/doi.org\/10.1007\/s11604-023-01485-0","journal-title":"Jpn J Radiol"},{"key":"12229_CR14","doi-asserted-by":"publisher","first-page":"e220158","DOI":"10.1148\/rg.220158","volume":"43","author":"AK Nehra","year":"2023","unstructured":"Nehra AK, Rajendran K, Baffour FI et al (2023) Seeing more with less: clinical benefits of photon-counting detector CT. Radiographics 43:e220158. https:\/\/doi.org\/10.1148\/rg.220158","journal-title":"Radiographics"},{"key":"12229_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2024.104585","volume":"46","author":"JP Mcdonald","year":"2025","unstructured":"Mcdonald JP, Farnsworth PJ, Campeau NG et al (2025) Improved visualization of the inferior tympanic and mastoid canaliculi with photon counting detector CT. Am J Otolaryngol Neck Med Surg 46:104585. https:\/\/doi.org\/10.1016\/j.amjoto.2024.104585","journal-title":"Am J Otolaryngol Neck Med Surg"},{"key":"12229_CR16","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1093\/dmfr\/twad010","volume":"53","author":"HL Kaatsch","year":"2024","unstructured":"Kaatsch HL, Fulisch F, Dillinger D et al (2024) Ultra-low-dose photon-counting CT of paranasal sinus: an in vivo comparison of radiation dose and image quality to cone-beam CT. Dentomaxillofac Radiol 53:103\u2013108. https:\/\/doi.org\/10.1093\/dmfr\/twad010","journal-title":"Dentomaxillofac Radiol"},{"key":"12229_CR17","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1186\/s13244-023-01467-w","volume":"14","author":"R Hermans","year":"2023","unstructured":"Hermans R, Boomgaert L, Cockmartin L et al (2023) Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT. Insights Imaging 14:112. https:\/\/doi.org\/10.1186\/s13244-023-01467-w","journal-title":"Insights Imaging"},{"key":"12229_CR18","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.3390\/tomography8040136","volume":"8","author":"S Waldeck","year":"2022","unstructured":"Waldeck S, Overhoff D, Alizadeh L et al (2022) Photon-counting detector CT virtual monoengergetic images for cochlear implant visualization\u2014a head to head comparison to energy-integrating detector CT. Tomography 8:1642\u20131648. https:\/\/doi.org\/10.3390\/tomography8040136","journal-title":"Tomography"},{"key":"12229_CR19","doi-asserted-by":"publisher","unstructured":"Boubaker F, Eliezer M, Poillon G et al (2025) Ultra-high-resolution CT of the temporal bone: technical aspects, current applications and future directions. Diagn Interv Imaging. https:\/\/doi.org\/10.1016\/j.diii.2025.02.003","DOI":"10.1016\/j.diii.2025.02.003"},{"key":"12229_CR20","doi-asserted-by":"publisher","unstructured":"Sakaida H, Ichikawa Y, Yamazaki A et al (2024) Ultra-high spatial resolution images of the temporal bone obtained with a newly released photon-counting detector computed tomography. Ear Nose Throat J. https:\/\/doi.org\/10.1177\/01455613241235551","DOI":"10.1177\/01455613241235551"},{"key":"12229_CR21","doi-asserted-by":"publisher","first-page":"111785","DOI":"10.1016\/j.ejrad.2024.111785","volume":"181","author":"E Klintstr\u00f6m","year":"2024","unstructured":"Klintstr\u00f6m E, Ly A, Sandborg M et al (2024) Image quality of photon-counting detector CT for visualization of maxillofacial anatomy in comparison with energy-integrating detector CT and intraoperative C-arm CBCT. Eur J Radiol 181:111785. https:\/\/doi.org\/10.1016\/j.ejrad.2024.111785","journal-title":"Eur J Radiol"},{"key":"12229_CR22","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.3174\/ajnr.A8265","volume":"45","author":"JC Benson","year":"2024","unstructured":"Benson JC, Campeau NG, Diehn FE et al (2024) Photon-counting CT in the head and neck: current applications and future prospects. AJNR Am J Neuroradiol 45:1000\u20131005. https:\/\/doi.org\/10.3174\/ajnr.A8265","journal-title":"AJNR Am J Neuroradiol"},{"key":"12229_CR23","doi-asserted-by":"publisher","first-page":"400","DOI":"10.3390\/tomography10030031","volume":"10","author":"A Klempka","year":"2024","unstructured":"Klempka A, Ackermann E, Clausen S, Groden C (2024) Photon counting computed tomography for accurate cribriform plate (lamina cribrosa) imaging in adult patients. Tomography 10:400\u2013414. https:\/\/doi.org\/10.3390\/tomography10030031","journal-title":"Tomography"},{"key":"12229_CR24","doi-asserted-by":"publisher","first-page":"4721","DOI":"10.1016\/j.radcr.2024.07.122","volume":"19","author":"S Shibata","year":"2024","unstructured":"Shibata S, Urano M, Kitera N et al (2024) Giant-cell arteritis on photon-counting detector CT: a case report. Radiol Case Rep 19:4721\u20134724. https:\/\/doi.org\/10.1016\/j.radcr.2024.07.122","journal-title":"Radiol Case Rep"},{"key":"12229_CR25","doi-asserted-by":"publisher","first-page":"2436","DOI":"10.3390\/jcm13082436","volume":"13","author":"C Zanon","year":"2024","unstructured":"Zanon C, Pepe A, Cademartiri F et al (2024) Potential benefits of photon-counting CT in dental imaging: a narrative review. J Clin Med 13:2436. https:\/\/doi.org\/10.3390\/jcm13082436","journal-title":"J Clin Med"},{"key":"12229_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-023-50926-3","volume":"14","author":"YC Layer","year":"2024","unstructured":"Layer YC, Mesropyan N, Kupczyk PA et al (2024) Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT. Sci Rep 14:1\u201310. https:\/\/doi.org\/10.1038\/s41598-023-50926-3","journal-title":"Sci Rep"},{"key":"12229_CR27","doi-asserted-by":"publisher","first-page":"7818","DOI":"10.1007\/s00330-023-09790-y","volume":"33","author":"TS Patzer","year":"2023","unstructured":"Patzer TS, Kunz AS, Huflage H et al (2023) Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants. Eur Radiol 33:7818\u20137829. https:\/\/doi.org\/10.1007\/s00330-023-09790-y","journal-title":"Eur Radiol"},{"key":"12229_CR28","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/RLI.0000000000000535","volume":"54","author":"W Zhou","year":"2019","unstructured":"Zhou W, Bartlett DJ, Diehn FE et al (2019) Reduction of metal artifacts and improvement in dose efficiency using photon-counting detector computed tomography and tin filtration. Invest Radiol 54:204\u2013211. https:\/\/doi.org\/10.1097\/RLI.0000000000000535","journal-title":"Invest Radiol"},{"key":"12229_CR29","doi-asserted-by":"publisher","unstructured":"Vanden Broeke L, Grillon M, Yeung AWK et al (2021) Feasibility of photon-counting spectral CT in dental applications\u2014a comparative qualitative analysis. BDJ Open. https:\/\/doi.org\/10.1038\/s41405-021-00060-x","DOI":"10.1038\/s41405-021-00060-x"},{"key":"12229_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/diagnostics14060626","volume":"14","author":"D Dillinger","year":"2024","unstructured":"Dillinger D, Overhoff D, Froelich MF et al (2024) Photon-counting detector CT virtual monoenergetic images in cervical trauma imaging\u2014optimization of dental metal artifacts and image quality. Diagnostics (Basel) 14:1\u201311. https:\/\/doi.org\/10.3390\/diagnostics14060626","journal-title":"Diagnostics (Basel)"},{"key":"12229_CR31","doi-asserted-by":"publisher","unstructured":"Smeijers S, Coudyzer W, Keirse E et al (2024) Direct visualization of microwires in hybrid depth electrodes using high-resolution photon-counting CT. Epilepsia Open. https:\/\/doi.org\/10.1002\/epi4.13080","DOI":"10.1002\/epi4.13080"},{"key":"12229_CR32","doi-asserted-by":"publisher","first-page":"1276","DOI":"10.1016\/j.brs.2023.08.015","volume":"16","author":"J Manfield","year":"2023","unstructured":"Manfield J, Thomas S, Antoniades C et al (2023) High resolution photon counting CT permits direct visualisation of directional deep brain stimulation lead segments and markers. Brain Stimul 16:1276\u20131277. https:\/\/doi.org\/10.1016\/j.brs.2023.08.015","journal-title":"Brain Stimul"},{"key":"12229_CR33","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/j.neurom.2023.09.003","volume":"27","author":"J Manfield","year":"2024","unstructured":"Manfield J, Thomas S, Bogdanovic M et al (2024) Seeing is believing: photon counting computed tomography clearly images directional deep brain stimulation lead segments and markers after implantation. Neuromodulation 27:557\u2013564. https:\/\/doi.org\/10.1016\/j.neurom.2023.09.003","journal-title":"Neuromodulation"},{"key":"12229_CR34","doi-asserted-by":"publisher","first-page":"543","DOI":"10.3390\/tomography10040043","volume":"10","author":"A Klempka","year":"2024","unstructured":"Klempka A, Clausen S, Soltane MI et al (2024) Three-dimensional visualization of shunt valves with photon counting CT and comparison to traditional X-ray in a simple phantom model. Tomography 10:543\u2013553. https:\/\/doi.org\/10.3390\/tomography10040043","journal-title":"Tomography"},{"key":"12229_CR35","doi-asserted-by":"publisher","first-page":"3742","DOI":"10.1007\/s00330-023-10430-8","volume":"34","author":"FB Pallasch","year":"2024","unstructured":"Pallasch FB, Rau A, Reisert M et al (2024) Impact of different metal artifact reduction techniques in photon-counting computed tomography head and neck scans in patients with dental hardware. Eur Radiol 34:3742\u20133749. https:\/\/doi.org\/10.1007\/s00330-023-10430-8","journal-title":"Eur Radiol"},{"key":"12229_CR36","doi-asserted-by":"publisher","first-page":"104859","DOI":"10.1016\/j.jdent.2024.104859","volume":"142","author":"S Sawall","year":"2024","unstructured":"Sawall S, Maier J, Sen S et al (2024) Dental imaging in clinical photon-counting CT at a quarter of DVT dose. J Dent 142:104859. https:\/\/doi.org\/10.1016\/j.jdent.2024.104859","journal-title":"J Dent"},{"key":"12229_CR37","doi-asserted-by":"publisher","first-page":"e2329950","DOI":"10.2214\/AJR.23.29950","volume":"222","author":"AA Marth","year":"2024","unstructured":"Marth AA, Marcus RP, Feuerriegel GC et al (2024) Photon-counting detector CT versus energy-integrating detector CT of the lumbar spine: comparison of radiation dose and image quality. AJR Am J Roentgenol 222:e2329950. https:\/\/doi.org\/10.2214\/AJR.23.29950","journal-title":"AJR Am J Roentgenol"},{"key":"12229_CR38","doi-asserted-by":"publisher","first-page":"4484","DOI":"10.1007\/s00330-023-10499-1","volume":"34","author":"M Fix Martinez","year":"2024","unstructured":"Fix Martinez M, Klein L, Maier J et al (2024) Potential radiation dose reduction in clinical photon-counting CT by the small pixel effect: ultra-high resolution (UHR) acquisitions reconstructed to standard resolution. Eur Radiol 34:4484\u20134491. https:\/\/doi.org\/10.1007\/s00330-023-10499-1","journal-title":"Eur Radiol"},{"key":"12229_CR39","doi-asserted-by":"publisher","first-page":"580","DOI":"10.2214\/AJR.22.28391","volume":"220","author":"J Cao","year":"2023","unstructured":"Cao J, Bache S, Schwartz FR, Frush D (2023) Pediatric applications of photon-counting detector CT. AJR Am J Roentgenol 220:580\u2013589. https:\/\/doi.org\/10.2214\/AJR.22.28391","journal-title":"AJR Am J Roentgenol"},{"key":"12229_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00247-023-05823-2","volume":"54","author":"I Mese","year":"2024","unstructured":"Mese I, Altintas Mese C, Demirsoy U, Anik Y (2024) Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond. Pediatr Radiol 54:1\u201311","journal-title":"Pediatr Radiol"},{"key":"12229_CR41","doi-asserted-by":"publisher","unstructured":"Sta\u0144ski M, Micha\u0142owska I, Lemanowicz A et al (2024) Dual-energy and photon-counting computed tomography in vascular applications\u2014technical background and post-processing techniques. Diagnostics (Basel). https:\/\/doi.org\/10.3390\/diagnostics14121223","DOI":"10.3390\/diagnostics14121223"},{"key":"12229_CR42","doi-asserted-by":"publisher","unstructured":"Shami A, Sun J, Gialeli C et al (2024) Atherosclerotic plaque features relevant to rupture-risk detected by clinical photon-counting CT ex vivo: a proof-of-concept study. Eur Radiol Exp. https:\/\/doi.org\/10.1186\/s41747-023-00410-4","DOI":"10.1186\/s41747-023-00410-4"},{"key":"12229_CR43","doi-asserted-by":"publisher","unstructured":"Meloni A, Cau R, Saba L et al (2024) Photon-counting computed tomography angiography of carotid arteries: a topical narrative review with case examples. Diagnostics (Basel). https:\/\/doi.org\/10.3390\/diagnostics14182012","DOI":"10.3390\/diagnostics14182012"},{"key":"12229_CR44","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/diagnostics14111065","volume":"14","author":"R Cau","year":"2024","unstructured":"Cau R, Saba L, Balestrieri A et al (2024) Photon-counting computed tomography in atherosclerotic plaque characterization. Diagnostics (Basel) 14:1\u201319. https:\/\/doi.org\/10.3390\/diagnostics14111065","journal-title":"Diagnostics (Basel)"},{"key":"12229_CR45","doi-asserted-by":"publisher","unstructured":"van der Bie J, Berghout BP, Budde RPJ et al (2025) Intracranial calcification detection; a comparison between micro-CT, conventional CT and ultra-high-resolution photon-counting detector CT. Acad Radiol. https:\/\/doi.org\/10.1016\/j.acra.2025.01.028","DOI":"10.1016\/j.acra.2025.01.028"},{"key":"12229_CR46","doi-asserted-by":"publisher","unstructured":"T\u00f3th A, Cho JY, Wilson E et al (2025) Photon-counting CT imaging of a patient with coiled and untreated intracranial saccular aneurysms. Neuroradiol J. https:\/\/doi.org\/10.1177\/19714009251313514","DOI":"10.1177\/19714009251313514"},{"key":"12229_CR47","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s41747-025-00550-9","volume":"9","author":"F De Beukelaer","year":"2025","unstructured":"De Beukelaer F, De Beukelaer S, Wuyts LL et al (2025) Photon-counting detector CTA to assess intracranial stents and flow diverters: an in vivo study with ultrahigh-resolution spectral reconstructions. Eur Radiol Exp 9:10. https:\/\/doi.org\/10.1186\/s41747-025-00550-9","journal-title":"Eur Radiol Exp"},{"key":"12229_CR48","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2023.10.FOCUS23640","volume":"56","author":"P Dodier","year":"2024","unstructured":"Dodier P, Civilla L, Mallouhi A et al (2024) An evaluation of physical and augmented patient-specific intracranial aneurysm simulators on microsurgical clipping performance and skills: a randomized controlled study. Neurosurg Focus 56:1\u201311. https:\/\/doi.org\/10.3171\/2023.10.FOCUS23640","journal-title":"Neurosurg Focus"},{"key":"12229_CR49","doi-asserted-by":"publisher","unstructured":"Maurer CJ, Berlis A, Stangl FJ, Behrens L (2025) In vivo discrimination of iodine and tantalum-based liquid embolics after intracranial or spinal embolization using photon-counting detector CT. Clin Neuroradiol. https:\/\/doi.org\/10.1007\/s00062-025-01502-x","DOI":"10.1007\/s00062-025-01502-x"},{"key":"12229_CR50","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.rx.2023.06.007","volume":"66","author":"S Lojo-Lendoiro","year":"2024","unstructured":"Lojo-Lendoiro S, Rovira MS (2024) Green radiology: how to develop sustainable radiology. Radiologia 66:248\u2013259. https:\/\/doi.org\/10.1016\/j.rx.2023.06.007","journal-title":"Radiologia"},{"key":"12229_CR51","doi-asserted-by":"publisher","first-page":"1445","DOI":"10.3174\/ajnr.A8040","volume":"44","author":"AA Madhavan","year":"2023","unstructured":"Madhavan AA, Cutsforth-Gregory JK, Brinjikji W et al (2023) Diagnostic performance of decubitus photon-counting detector CT myelography for the detection of CSF-venous fistulas. AJNR Am J Neuroradiol 44:1445\u20131450. https:\/\/doi.org\/10.3174\/ajnr.A8040","journal-title":"AJNR Am J Neuroradiol"},{"key":"12229_CR52","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2214\/AJR.23.30673","volume":"222","author":"FR Schwartz","year":"2024","unstructured":"Schwartz FR, Kranz PG, Malinzak MD et al (2024) Myelography using energy-integrating detector CT versus photon-counting detector CT for detection of CSF-venous fistulas in patients with spontaneous intracranial hypotension. AJR Am J Roentgenol 222:1\u20139. https:\/\/doi.org\/10.2214\/AJR.23.30673","journal-title":"AJR Am J Roentgenol"},{"key":"12229_CR53","doi-asserted-by":"publisher","first-page":"846","DOI":"10.3174\/ajnr.A8736","volume":"46","author":"AA Madhavan","year":"2025","unstructured":"Madhavan AA, Kranz PG, Brinjikji W et al (2025) Photon-counting CT myelography for the detection of spinal CSF leaks. AJNR Am J Neuroradiol 46:846. https:\/\/doi.org\/10.3174\/ajnr.A8736","journal-title":"AJNR Am J Neuroradiol"},{"key":"12229_CR54","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s11604-024-01661-w","volume":"43","author":"F Higaki","year":"2024","unstructured":"Higaki F, Hiramatsu M, Yasuhara T et al (2024) Cranial and spinal computed tomography (CT) angiography with photon-counting detector CT: comparison with angiographic and operative findings. Jpn J Radiol 43:143\u2013151. https:\/\/doi.org\/10.1007\/s11604-024-01661-w","journal-title":"Jpn J Radiol"},{"key":"12229_CR55","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1097\/RLI.0000000000001069","volume":"59","author":"H Huflage","year":"2024","unstructured":"Huflage H, Hendel R, Woznicki P et al (2024) The small pixel effect in ultra-high-resolution photon-counting CT of the lumbar spine. Invest Radiol 59:629\u2013634. https:\/\/doi.org\/10.1097\/RLI.0000000000001069","journal-title":"Invest Radiol"},{"key":"12229_CR56","doi-asserted-by":"publisher","first-page":"e231878","DOI":"10.1148\/radiol.231878","volume":"310","author":"A Surov","year":"2024","unstructured":"Surov A, Niehoff JH (2024) Bone marrow edema at photon-counting CT. Radiology 310:e231878","journal-title":"Radiology"},{"key":"12229_CR57","doi-asserted-by":"publisher","first-page":"662","DOI":"10.3348\/kjr.2024.0096","volume":"25","author":"J-P Grunz","year":"2024","unstructured":"Grunz J-P, Huflage H (2024) Photon-counting computed tomography: experience in musculoskeletal imaging. Korean J Radiol 25:662. https:\/\/doi.org\/10.3348\/kjr.2024.0096","journal-title":"Korean J Radiol"},{"key":"12229_CR58","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/s41747-024-00482-w","volume":"8","author":"E Zsarnoczay","year":"2024","unstructured":"Zsarnoczay E, Fink N, Schoepf UJ et al (2024) Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study. Eur Radiol Exp 8:102. https:\/\/doi.org\/10.1186\/s41747-024-00482-w","journal-title":"Eur Radiol Exp"},{"key":"12229_CR59","doi-asserted-by":"publisher","unstructured":"Bette SJ, Braun FM, Luitjens JH et al (2024) Multiplanar reconstructions of the thoracic spine in a photon counting dual-source CT scanner: comparison to EID-CT. Acta Radiol. https:\/\/doi.org\/10.1177\/02841851241271109","DOI":"10.1177\/02841851241271109"},{"key":"12229_CR60","doi-asserted-by":"publisher","first-page":"2453","DOI":"10.1088\/0031-9155\/60\/6\/2453","volume":"60","author":"PM Shikhaliev","year":"2015","unstructured":"Shikhaliev PM (2015) Soft tissue imaging with photon counting spectroscopic CT. Phys Med Biol 60:2453\u20132474. https:\/\/doi.org\/10.1088\/0031-9155\/60\/6\/2453","journal-title":"Phys Med Biol"},{"key":"12229_CR61","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.clinimag.2023.08.004","volume":"102","author":"F Farhadi","year":"2023","unstructured":"Farhadi F, Sahbaee P, Rajagopal JR et al (2023) Virtual monoenergetic imaging in photon-counting CT of the head and neck. Clin Imaging 102:109\u2013115. https:\/\/doi.org\/10.1016\/j.clinimag.2023.08.004","journal-title":"Clin Imaging"},{"key":"12229_CR62","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/RLI.0000000000000418","volume":"53","author":"R Symons","year":"2018","unstructured":"Symons R, Reich DS, Bagheri M et al (2018) Photon-counting computed tomography for vascular imaging of the head and neck: first in vivo human results. Invest Radiol 53:135\u2013142. https:\/\/doi.org\/10.1097\/RLI.0000000000000418","journal-title":"Invest Radiol"},{"key":"12229_CR63","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.rx.2022.05.005","volume":"64","author":"E Santos Armentia","year":"2022","unstructured":"Santos Armentia E, Mart\u00edn-Noguerol T, Silva Priegue N et al (2022) An\u00e1lisis de las fortalezas, oportunidades, debilidades y amenazas de la tomograf\u00eda computarizada de doble energ\u00eda en el diagn\u00f3stico por la imagen de la cabeza y el cuello. Radiologia 64:333\u2013347. https:\/\/doi.org\/10.1016\/j.rx.2022.05.005","journal-title":"Radiologia"},{"key":"12229_CR64","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1007\/s00234-024-03308-z","volume":"66","author":"D Schoenbeck","year":"2024","unstructured":"Schoenbeck D, Sacha A, Niehoff JH et al (2024) Imaging of intracranial hemorrhage in photon counting computed tomography using virtual monoenergetic images. Neuroradiology 66:729\u2013736. https:\/\/doi.org\/10.1007\/s00234-024-03308-z","journal-title":"Neuroradiology"},{"key":"12229_CR65","doi-asserted-by":"publisher","first-page":"743","DOI":"10.3174\/ajnr.A8171","volume":"45","author":"IT Mark","year":"2024","unstructured":"Mark IT, Van Gompel J, Bancos I et al (2024) Back to the future: dynamic contrast-enhanced photon-counting detector CT for the detection of pituitary adenoma in Cushing disease. AJNR Am J Neuroradiol 45:743\u2013746. https:\/\/doi.org\/10.3174\/ajnr.A8171","journal-title":"AJNR Am J Neuroradiol"},{"key":"12229_CR66","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s00062-023-01331-w","volume":"34","author":"AE Michael","year":"2024","unstructured":"Michael AE, Schoenbeck D, Woeltjen MM et al (2024) Nonenhanced photon counting CT of the head: impact of the keV level, iterative reconstruction and calvaria on image quality in monoenergetic images. Clin Neuroradiol 34:75\u201383. https:\/\/doi.org\/10.1007\/s00062-023-01331-w","journal-title":"Clin Neuroradiol"},{"key":"12229_CR67","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1177\/19714009241240056","volume":"37","author":"D Schoenbeck","year":"2024","unstructured":"Schoenbeck D, Sacha A, Niehoff JH et al (2024) Imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images. Neuroradiol J 37:336\u2013341. https:\/\/doi.org\/10.1177\/19714009241240056","journal-title":"Neuroradiol J"},{"key":"12229_CR68","doi-asserted-by":"publisher","first-page":"854","DOI":"10.3348\/kjr.2022.0377","volume":"23","author":"A Esquivel","year":"2022","unstructured":"Esquivel A, Ferrero A, Mileto A et al (2022) Photon-counting detector CT: key points radiologists should know. Korean J Radiol 23:854\u2013865","journal-title":"Korean J Radiol"},{"key":"12229_CR69","doi-asserted-by":"publisher","unstructured":"Sawall S, Klein L, Amato C et al (2020) Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol. https:\/\/doi.org\/10.1016\/j.ejrad.2020.108909","DOI":"10.1016\/j.ejrad.2020.108909"},{"key":"12229_CR70","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1097\/RLI.0000000000000978","volume":"58","author":"G Jost","year":"2023","unstructured":"Jost G, McDermott M, Gutjahr R et al (2023) New contrast media for K-edge imaging with photon-counting detector CT. Invest Radiol 58:515\u2013522","journal-title":"Invest Radiol"},{"key":"12229_CR71","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s41747-025-00577-y","volume":"9","author":"K Klambauer","year":"2025","unstructured":"Klambauer K, Flohr T, Moser LJ et al (2025) Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT. Eur Radiol Exp 9:37. https:\/\/doi.org\/10.1186\/s41747-025-00577-y","journal-title":"Eur Radiol Exp"},{"key":"12229_CR72","doi-asserted-by":"publisher","unstructured":"Popp D, Siedlecki M, Friedrich L et al (2025) Potential of photon-counting detector CT technology for contrast medium reduction in portal venous phase thoracoabdominal CT. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-025-11409-3","DOI":"10.1007\/s00330-025-11409-3"},{"key":"12229_CR73","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111680","volume":"179","author":"EJI Hoeijmakers","year":"2024","unstructured":"Hoeijmakers EJI, Stammen L, Wildberger JE et al (2024) PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT. Eur J Radiol 179:111680. https:\/\/doi.org\/10.1016\/j.ejrad.2024.111680","journal-title":"Eur J Radiol"},{"key":"12229_CR74","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1007\/s10278-023-00788-y","volume":"36","author":"M Isikbay","year":"2023","unstructured":"Isikbay M, Caton MT, Calabrese E (2023) A deep learning approach for automated bone removal from computed tomography angiography of the brain. J Digit Imaging 36:964\u2013972. https:\/\/doi.org\/10.1007\/s10278-023-00788-y","journal-title":"J Digit Imaging"},{"key":"12229_CR75","doi-asserted-by":"publisher","first-page":"143","DOI":"10.3390\/brainsci13010143","volume":"13","author":"N Han","year":"2023","unstructured":"Han N, Ma Y, Li Y et al (2023) Imaging and hemodynamic characteristics of vulnerable carotid plaques and artificial intelligence applications in plaque classification and segmentation. Brain Sci 13:143","journal-title":"Brain Sci"},{"key":"12229_CR76","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1097\/rli.0000000000000928","volume":"58","author":"DJ Lin","year":"2023","unstructured":"Lin DJ, Walter SS, Fritz J (2023) Artificial intelligence\u2013driven ultra-fast superresolution MRI. Invest Radiol 58:28\u201342. https:\/\/doi.org\/10.1097\/rli.0000000000000928","journal-title":"Invest Radiol"},{"key":"12229_CR77","doi-asserted-by":"publisher","first-page":"2988","DOI":"10.1016\/j.acra.2023.04.019","volume":"30","author":"S Altmann","year":"2023","unstructured":"Altmann S, Abello Mercado MA, Brockstedt L et al (2023) Ultrafast brain MRI protocol at 1.5 T using deep learning and multi-shot EPI. Acad Radiol 30:2988\u20132998. https:\/\/doi.org\/10.1016\/j.acra.2023.04.019","journal-title":"Acad Radiol"},{"key":"12229_CR78","doi-asserted-by":"publisher","first-page":"109900","DOI":"10.1016\/j.ejrad.2021.109900","volume":"143","author":"T Mart\u00edn-Noguerol","year":"2021","unstructured":"Mart\u00edn-Noguerol T, Mohan S, Santos-Armentia E et al (2021) Advanced MRI assessment of non-enhancing peritumoral signal abnormality in brain lesions. Eur J Radiol 143:109900","journal-title":"Eur J Radiol"},{"key":"12229_CR79","doi-asserted-by":"publisher","first-page":"e231741","DOI":"10.1148\/radiol.231741","volume":"311","author":"KK Horst","year":"2024","unstructured":"Horst KK, Cao JY, McCollough CH et al (2024) Multi-institutional protocol guidance for pediatric photon-counting CT. Radiology 311:e231741. https:\/\/doi.org\/10.1148\/radiol.231741","journal-title":"Radiology"},{"key":"12229_CR80","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1097\/RLI.0000000000000984","volume":"58","author":"F Abel","year":"2023","unstructured":"Abel F, Schubert T, Winklhofer S (2023) Advanced neuroimaging with photon-counting detector CT. Invest Radiol 58:472\u2013481","journal-title":"Invest Radiol"},{"key":"12229_CR81","doi-asserted-by":"publisher","first-page":"2362","DOI":"10.1016\/j.acra.2023.05.029","volume":"30","author":"Y Wu","year":"2023","unstructured":"Wu Y, Ye Z, Chen J et al (2023) Photon counting CT: technical principles, clinical applications, and future prospects. Acad Radiol 30:2362\u20132382","journal-title":"Acad Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-12229-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-025-12229-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-025-12229-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T11:22:56Z","timestamp":1776338576000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-025-12229-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,19]]},"references-count":81,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,5]]}},"alternative-id":["12229"],"URL":"https:\/\/doi.org\/10.1007\/s00330-025-12229-1","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,19]]},"assertion":[{"value":"26 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 October 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The scientific guarantor of this publication is Dr. Antonio Luna.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"The authors of this manuscript declare relationships with the following companies: Antonio Luna, MD, PhD, is an occasional lecturer for Philips, Siemens Healthineers, Bracco and Canon, and receives royalties as book editor from Springer-Verlag. The rest of the authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statistics and biometry"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"Not applicable.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":7,"name":"Ethics","group":{"name":"EthicsHeading","label":"Study subjects or cohorts overlap"}},{"order":8,"name":"Ethics","group":{"name":"EthicsHeading","label":"Methodology"}}]}}