{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:50:38Z","timestamp":1791582638740,"version":"4.3.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare virtual non-contrast (VNC) images derived from arterial (VNC_A) and portal venous phase (VNC_P) of dual-layer spectral CT (DLCT) with true non-contrast (TNC) images in abdominal imaging, assessing attenuation accuracy, image quality, lesion and calcification measurements, and the potential of VNC to replace TNC in routine protocols.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>One hundred consecutive patients undergoing triphasic abdominal CT were included. TNC, arterial, and portal venous phases were acquired on a DLCT scanner. VNC_A and VNC_P images were generated using a two-material decomposition algorithm. Attenuation values, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion and calcification metrics were measured. Subjective image quality and diagnostic acceptability were graded by three radiologists. Agreement with TNC was evaluated using ICC, Bland\u2013Altman analysis, ANOVA, and non-parametric tests. Radiation dose reduction achievable by omitting the TNC phase was also assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Although VNC_A showed better agreement with TNC than VNC_P, both consistently underestimated parenchymal and lesion attenuation; lesion size was preserved (12.2\u2009\u00b1\u20097.9\u2009mm;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.996). Calcification density was significantly reduced in both VNC phases, and calcification diameter was slightly underestimated in VNC_A (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). VNC images demonstrated higher or similar SNR and CNR but inferior subjective image quality (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), due to blotchier appearance. Only 12% of VNC_P datasets were judged fully interchangeable with TNC. Replacing TNC with VNC would yield a 33% radiation dose reduction in this specific protocol.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>VNC cannot replace TNC based on the current evidence; further refinements are required for broader clinical adoption.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>True non-contrast images (TNC) are essential in abdominal CT, yet it remains unclear whether spectral CT-derived virtual non-contrast images (VNC) can reliably replace TNC imaging.<\/jats:italic>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>VNC images approximate TNC images but introduce consistent attenuation biases, reduced subjective quality, and altered calcification metrics, preventing full replacement of dedicated non-contrast acquisitions.<\/jats:italic>\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Clinical relevance<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>Replacing TNC with VNC images reduces radiation exposure, yet current VNC performance shows measurable differences from TNC, indicating that algorithmic refinement is required before routine diagnostic use in abdominal CT.<\/jats:italic>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00330-026-12642-0","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T14:39:20Z","timestamp":1780497560000},"page":"7718-7730","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures"],"prefix":"10.1007","volume":"36","author":[{"given":"Domenico","family":"De Santis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonella","family":"Del Gaudio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benedetta","family":"Masci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bianca","family":"Catalano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Zerunian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Polici","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Pucciarelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Tremamunno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiziano","family":"Polidori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ettore","family":"Squillaci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesare","family":"Maino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Ippolito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7906-3420","authenticated-orcid":false,"given":"Marco","family":"Francone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damiano","family":"Caruso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"key":"12642_CR1","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.rcl.2018.03.010","volume":"56","author":"D De Santis","year":"2018","unstructured":"De Santis D, Eid M, De Cecco CN et al (2018) Dual-energy computed tomography in cardiothoracic vascular imaging. Radiol Clin North Am 56:521\u2013534","journal-title":"Radiol Clin North Am"},{"key":"12642_CR2","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1148\/rg.304095175","volume":"30","author":"CA Coursey","year":"2010","unstructured":"Coursey CA, Nelson RC, Boll DT et al (2010) Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 30:1037\u20131055","journal-title":"Radiographics"},{"key":"12642_CR3","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-78518-5","volume":"10","author":"JA Holz","year":"2020","unstructured":"Holz JA, Alkadhi H, Laukamp KR et al (2020) Quantitative accuracy of virtual non-contrast images derived from spectral detector computed tomography: an abdominal phantom study. Sci Rep 10:21575","journal-title":"Sci Rep"},{"key":"12642_CR4","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13244-021-01146-8","volume":"13","author":"X Zhang","year":"2022","unstructured":"Zhang X, Zhang G, Xu L et al (2022) Utilisation of virtual non-contrast images and virtual mono-energetic images acquired from dual-layer spectral CT for renal cell carcinoma: image quality and radiation dose. Insights Imaging 13:12","journal-title":"Insights Imaging"},{"key":"12642_CR5","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1177\/0284185119893094","volume":"61","author":"KR Laukamp","year":"2020","unstructured":"Laukamp KR, Ho V, Obmann VC et al (2020) Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT. Acta Radiol 61:1143\u20131152","journal-title":"Acta Radiol"},{"key":"12642_CR6","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1097\/RLI.0000000000001178","volume":"60","author":"D De Santis","year":"2025","unstructured":"De Santis D, Del Gaudio A, Santangeli C et al (2025) Every drop (photon) counts: current applications and future challenges of photon-counting detector CT in abdominal imaging. Invest Radiol 60:647\u2013657","journal-title":"Invest Radiol"},{"key":"12642_CR7","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1007\/s00261-016-1036-9","volume":"42","author":"L Ananthakrishnan","year":"2017","unstructured":"Ananthakrishnan L, Rajiah P, Ahn R et al (2017) Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT. Abdom Radiol 42:702\u2013709","journal-title":"Abdom Radiol"},{"key":"12642_CR8","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/RCT.0000000000001258","volume":"46","author":"M Azuma","year":"2022","unstructured":"Azuma M, Nakada H, Khant ZA, Kimura A, Hirai T (2022) Virtual noncontrast images derived from contrast-enhanced dual-layer spectral abdominal computed tomography: a pilot study between pediatric and adult scans. J Comput Assist Tomogr 46:71\u201377","journal-title":"J Comput Assist Tomogr"},{"key":"12642_CR9","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ejrad.2018.05.007","volume":"104","author":"AP Sauter","year":"2018","unstructured":"Sauter AP, Muenzel D, Dangelmaier J et al (2018) Dual-layer spectral computed tomography: virtual non-contrast in comparison to true non-contrast images. Eur J Radiol 104:108\u2013114","journal-title":"Eur J Radiol"},{"key":"12642_CR10","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/j.diii.2019.04.007","volume":"100","author":"S Jamali","year":"2019","unstructured":"Jamali S, Michoux N, Coche E, Dragean CA (2019) Virtual unenhanced phase with spectral dual-energy CT: is it an alternative to conventional true unenhanced phase for abdominal tissues? Diagn Interv Imaging 100:503\u2013511","journal-title":"Diagn Interv Imaging"},{"key":"12642_CR11","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s13244-021-00980-0","volume":"12","author":"D Caruso","year":"2021","unstructured":"Caruso D, Rosati E, Panvini N et al (2021) Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols. Insights Imaging 12:40","journal-title":"Insights Imaging"},{"key":"12642_CR12","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1148\/rg.2016150220","volume":"36","author":"M Patino","year":"2016","unstructured":"Patino M, Prochowski A, Agrawal MD et al (2016) Material separation using dual-energy CT: current and emerging applications. Radiographics 36:1087\u20131105","journal-title":"Radiographics"},{"key":"12642_CR13","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1148\/radiol.2021192448","volume":"298","author":"JM Xiao","year":"2021","unstructured":"Xiao JM, Hippe DS, Zecevic M et al (2021) Virtual unenhanced dual-energy CT images obtained with a multimaterial decomposition algorithm: diagnostic value for renal mass and urinary stone evaluation. Radiology 298:611\u2013619","journal-title":"Radiology"},{"key":"12642_CR14","doi-asserted-by":"publisher","first-page":"2384","DOI":"10.1007\/s00330-023-10171-8","volume":"34","author":"D Caruso","year":"2024","unstructured":"Caruso D, De Santis D, Del Gaudio A et al (2024) Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm. Eur Radiol 34:2384\u20132393","journal-title":"Eur Radiol"},{"key":"12642_CR15","first-page":"333","volume":"13","author":"D Pakravan","year":"2023","unstructured":"Pakravan D (2023) Presentation of organ dose and effective dose conversion factors in dual-energy computed tomography: a Monte Carlo simulation study. J Biomed Phys Eng 13:333\u2013344","journal-title":"J Biomed Phys Eng"},{"key":"12642_CR16","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15:155\u2013163","journal-title":"J Chiropr Med"},{"key":"12642_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109741","volume":"140","author":"MH Choi","year":"2021","unstructured":"Choi MH, Lee YJ, Choi YJ, Pak S (2021) Dual-energy CT of the liver: true noncontrast vs. virtual noncontrast images derived from multiple phases for the diagnosis of fatty liver. Eur J Radiol 140:109741","journal-title":"Eur J Radiol"},{"key":"12642_CR18","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1016\/j.ejrad.2016.04.012","volume":"85","author":"CN De Cecco","year":"2016","unstructured":"De Cecco CN, Muscogiuri G, Schoepf UJ et al (2016) Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction. Eur J Radiol 85:1257\u20131264","journal-title":"Eur J Radiol"},{"key":"12642_CR19","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1016\/j.ejrad.2014.06.017","volume":"83","author":"D Botsikas","year":"2014","unstructured":"Botsikas D, Triponez F, Boudabbous S, Hansen C, Becker CD, Montet X (2014) Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: can the diagnostic workup be shortened by the implementation of virtual unenhanced images? Eur J Radiol 83:1746\u20131751","journal-title":"Eur J Radiol"},{"key":"12642_CR20","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1148\/radiol.12112735","volume":"267","author":"YK Kim","year":"2013","unstructured":"Kim YK, Park BK, Kim CK, Park SY (2013) Adenoma characterization: adrenal protocol with dual-energy CT. Radiology 267:155\u2013163","journal-title":"Radiology"},{"key":"12642_CR21","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.acra.2013.01.010","volume":"20","author":"S Kaufmann","year":"2013","unstructured":"Kaufmann S, Sauter A, Spira D et al (2013) Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging. Acad Radiol 20:596\u2013603","journal-title":"Acad Radiol"},{"key":"12642_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/RLI.0b013e31826e7902","volume":"48","author":"CN De Cecco","year":"2013","unstructured":"De Cecco CN, Darnell A, Macias N et al (2013) Virtual unenhanced images of the abdomen with second-generation dual-source dual-energy computed tomography: image quality and liver lesion detection. Invest Radiol 48:1\u20139","journal-title":"Invest Radiol"},{"key":"12642_CR23","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1148\/radiol.213260","volume":"305","author":"V Mergen","year":"2022","unstructured":"Mergen V, Racine D, Jungblut L et al (2022) Virtual noncontrast abdominal imaging with photon-counting detector CT. Radiology 305:107\u2013115","journal-title":"Radiology"},{"key":"12642_CR24","doi-asserted-by":"crossref","first-page":"205846011879011","DOI":"10.1177\/2058460118790115","volume":"7","author":"L Lehti","year":"2018","unstructured":"Lehti L, Soderberg M, Hoglund P, Nyman U, Gottsater A, Wasselius J (2018) Reliability of virtual non-contrast computed tomography angiography: comparing it with the real deal. Acta Radiol Open 7:2058460118790115","journal-title":"Acta Radiol Open"},{"key":"12642_CR25","doi-asserted-by":"publisher","first-page":"7216","DOI":"10.1088\/1361-6560\/aa8103","volume":"62","author":"S Leng","year":"2017","unstructured":"Leng S, Zhou W, Yu Z et al (2017) Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets. Phys Med Biol 62:7216\u20137232","journal-title":"Phys Med Biol"},{"key":"12642_CR26","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1148\/radiol.2421052066","volume":"242","author":"BA Birnbaum","year":"2007","unstructured":"Birnbaum BA, Hindman N, Lee J, Babb JS (2007) Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom. Radiology 242:109\u2013119","journal-title":"Radiology"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12642-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-026-12642-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12642-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T21:02:46Z","timestamp":1791579766000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-026-12642-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":26,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["12642"],"URL":"https:\/\/doi.org\/10.1007\/s00330-026-12642-0","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"assertion":[{"value":"8 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The scientific guarantor of this publication is Prof. Damiano Caruso.","order":1,"name":"Ethics","label":"Guarantor","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Cesare Maino is a member of the\n                      European Radiology\n                      Editorial Board and, as such, has not participated in the review or selection processes for this article. Marco Francone is a member of the\n                      European Radiology\n                      Editorial Board and, as such, has not participated in the review or selection processes for this article. The remaining authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"No complex statistical methods were necessary for this paper.","order":3,"name":"Ethics","label":"Statistics and biometry","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":4,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Institutional Review Board approval was obtained.","order":5,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"No study subjects or cohorts have been previously reported.","order":6,"name":"Ethics","label":"Study subjects or cohorts overlap","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"order":7,"name":"Ethics","label":"Methodology","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}}]}}