{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T19:45:47Z","timestamp":1793043947140,"version":"4.5.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-026-12829-5","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T11:16:48Z","timestamp":1787570208000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7545-0669","authenticated-orcid":false,"given":"Shingo","family":"Kato","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai","family":"Azuma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Horita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minori","family":"Kinoshita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takumi","family":"Iwahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naofumi","family":"Yasuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shungo","family":"Sawamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinobu","family":"Ishiwata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Utsunomiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,24]]},"reference":[{"key":"12829_CR1","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1093\/eurheartj\/ehz405","volume":"41","author":"SV Konstantinides","year":"2020","unstructured":"Konstantinides SV, Meyer G, Becattini C et al (2020) 2019 ESC guidelines for the diagnosis and management of acute pulmonary embolism. Eur Heart J 41:543\u2013603","journal-title":"Eur Heart J"},{"key":"12829_CR2","doi-asserted-by":"publisher","first-page":"1973","DOI":"10.1161\/CIRCULATIONAHA.110.015008","volume":"124","author":"J Pepke-Zaba","year":"2011","unstructured":"Pepke-Zaba J, Delcroix M, Lang I et al (2011) Chronic thromboembolic pulmonary hypertension (CTEPH): results from an international prospective registry. Circulation 124:1973\u20131981","journal-title":"Circulation"},{"key":"12829_CR3","doi-asserted-by":"publisher","first-page":"2146","DOI":"10.1056\/NEJMra1805256","volume":"380","author":"R Mehran","year":"2019","unstructured":"Mehran R, Dangas GD, Weisbord SD (2019) Contrast-associated acute kidney injury. N Engl J Med 380:2146\u20132155","journal-title":"N Engl J Med"},{"key":"12829_CR4","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1148\/rg.2015150033","volume":"35","author":"KR Beckett","year":"2015","unstructured":"Beckett KR, Moriarity AK, Langer JM (2015) Safe use of contrast media: what the radiologist needs to know. Radiographics 35:1738\u20131750","journal-title":"Radiographics"},{"key":"12829_CR5","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1148\/radiology.212.3.r99se02615","volume":"212","author":"M R\u00e9my-Jardin","year":"1999","unstructured":"R\u00e9my-Jardin M, R\u00e9my J (1999) Spiral CT angiography of the pulmonary circulation. Radiology 212:615\u2013636","journal-title":"Radiology"},{"key":"12829_CR6","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A et al (2018) Photon-counting CT: technical principles and clinical prospects. Radiology 289:293\u2013312","journal-title":"Radiology"},{"key":"12829_CR7","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1148\/rg.2019180115","volume":"39","author":"S Leng","year":"2019","unstructured":"Leng S, Bruesewitz M, Tao S et al (2019) Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics 39:729\u2013743","journal-title":"Radiographics"},{"key":"12829_CR8","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","volume":"79","author":"T Flohr","year":"2020","unstructured":"Flohr T, Petersilka M, Henning A et al (2020) Photon-counting CT review. Phys Med 79:126\u2013136","journal-title":"Phys Med"},{"key":"12829_CR9","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran K, Petersilka M, Henning A et al (2022) First clinical photon-counting detector CT system: technical evaluation. Radiology 303:130\u2013138","journal-title":"Radiology"},{"key":"12829_CR10","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/RLI.0000000000000251","volume":"51","author":"R Gutjahr","year":"2016","unstructured":"Gutjahr R, Halaweish AF, Yu Z et al (2016) Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies. Invest Radiol 51:421\u2013429","journal-title":"Invest Radiol"},{"key":"12829_CR11","unstructured":"U.S. Food and Drug Administration (2021) K211591: NAEOTOM Alpha CT scanner. 510(k) premarket notification. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K211591"},{"key":"12829_CR12","doi-asserted-by":"publisher","first-page":"e63","DOI":"10.5114\/pjr.2024.134905","volume":"89","author":"JH Chamberlin","year":"2024","unstructured":"Chamberlin JH, Toth A, Hinen S et al (2024) Optimisation of virtual monoenergetic reconstructions for the diagnosis of pulmonary embolism using photon-counting detector computed tomography angiography. Pol J Radiol 89:e63\u2013e69","journal-title":"Pol J Radiol"},{"key":"12829_CR13","doi-asserted-by":"crossref","unstructured":"Schwartz FR, Khanungwanitkul K, Czajkowski B et al (2026) Optimizing photon-counting CT pulmonary angiography for robustness, combining mixed bolus, fixed scan delay and low keV. Eur J Radiol 195:112540","DOI":"10.1016\/j.ejrad.2025.112540"},{"key":"12829_CR14","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM et al (2021) The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372:n71","journal-title":"BMJ"},{"key":"12829_CR15","doi-asserted-by":"publisher","first-page":"l4898","DOI":"10.1136\/bmj.l4898","volume":"366","author":"JAC Sterne","year":"2019","unstructured":"Sterne JAC, Savovi\u0107 J, Page MJ et al (2019) RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 366:l4898","journal-title":"BMJ"},{"key":"12829_CR16","doi-asserted-by":"publisher","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","volume":"155","author":"PF Whiting","year":"2011","unstructured":"Whiting PF, Rutjes AW, Westwood ME et al (2011) QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155:529\u2013536","journal-title":"Ann Intern Med"},{"key":"12829_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v036.i03","volume":"36","author":"W Viechtbauer","year":"2010","unstructured":"Viechtbauer W (2010) Conducting meta-analyses in R with the metafor package. J Stat Softw 36:1\u201348","journal-title":"J Stat Softw"},{"key":"12829_CR18","unstructured":"Higgins JPT, Thomas J, Chandler J et al (2023) Cochrane handbook for systematic reviews of interventions version 6.4 (updated August 2023). Cochrane, London, UK"},{"key":"12829_CR19","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ 327:557\u2013560","journal-title":"BMJ"},{"key":"12829_CR20","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1177\/1536867X0400400204","volume":"4","author":"JAC Sterne","year":"2004","unstructured":"Sterne JAC, Harbord RM (2004) Funnel plots in meta-analysis. Stata J 4:127\u2013141","journal-title":"Stata J"},{"key":"12829_CR21","doi-asserted-by":"publisher","first-page":"7830","DOI":"10.1007\/s00330-023-09777-9","volume":"33","author":"P Pannenbecker","year":"2023","unstructured":"Pannenbecker P, Grunz JP, Hartung V et al (2023) Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction. Eur Radiol 33:7830\u20137839","journal-title":"Eur Radiol"},{"key":"12829_CR22","doi-asserted-by":"publisher","first-page":"6544","DOI":"10.1007\/s00330-024-10724-5","volume":"34","author":"M Remy-Jardin","year":"2024","unstructured":"Remy-Jardin M, Faivre JB, Duthoit L et al (2024) Diagnosis of acute pulmonary embolism: when photon-counting-detector CT replaces energy-integrating-detector CT in daily routine. Eur Radiol 34:6544\u20136555","journal-title":"Eur Radiol"},{"key":"12829_CR23","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1097\/RCT.0000000000001645","volume":"48","author":"M Yalon","year":"2024","unstructured":"Yalon M, Hoodeshenas S, Chan A et al (2024) Improved pulmonary artery evaluation using high-pitch photon-counting CT compared to high-pitch conventional or routine-pitch conventional dual-energy CT. J Comput Assist Tomogr 48:897\u2013905","journal-title":"J Comput Assist Tomogr"},{"key":"12829_CR24","doi-asserted-by":"publisher","first-page":"5280","DOI":"10.1016\/j.acra.2024.06.028","volume":"31","author":"P Pannenbecker","year":"2024","unstructured":"Pannenbecker P, Heidenreich JF, Huflage H et al (2024a) The best of both worlds: ultra-high-pitch pulmonary angiography with free-breathing technique by means of photon-counting detector CT for diagnosis of acute pulmonary embolism. Acad Radiol 31:5280\u20135288","journal-title":"Acad Radiol"},{"key":"12829_CR25","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.23.30154","volume":"222","author":"P Pannenbecker","year":"2024","unstructured":"Pannenbecker P, Heidenreich JF, Grunz JP et al (2024b) Image quality and radiation dose of CTPA with iodine maps: a prospective randomized study of high-pitch mode photon-counting detector CT versus energy-integrating detector CT. AJR Am J Roentgenol 222:e2330126","journal-title":"AJR Am J Roentgenol"},{"key":"12829_CR26","doi-asserted-by":"publisher","first-page":"3206","DOI":"10.1007\/s00330-025-12054-6","volume":"36","author":"L Stammen","year":"2026","unstructured":"Stammen L, Hoeijmakers EJI, Flohr TG et al (2026) Reducing contrast media dosage for pulmonary embolism CTPA in PCD-CT: a comparative study of EID-CT and PCD-CT in the era of individualized protocolling. Eur Radiol 36:3206\u20133215","journal-title":"Eur Radiol"},{"key":"12829_CR27","first-page":"317","volume":"60","author":"B Kerber","year":"2025","unstructured":"Kerber B, Flohr T, Ulrich S et al (2025a) Photon-counting CT iodine maps for diagnosing chronic pulmonary thromboembolism: a pilot study. Invest Radiol 60:317\u2013324","journal-title":"Invest Radiol"},{"key":"12829_CR28","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1097\/RLI.0000000000001163","volume":"60","author":"B Kerber","year":"2025","unstructured":"Kerber B, H\u00fcllner M, Maurer A et al (2025b) Photon-counting detector CT iodine maps versus SPECT\/CT: advancing lung perfusion imaging in chronic thromboembolic pulmonary hypertension. Invest Radiol 60:569\u2013576","journal-title":"Invest Radiol"},{"key":"12829_CR29","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/j.acra.2023.05.018","volume":"31","author":"S Saeed","year":"2024","unstructured":"Saeed S, Niehoff JH, Boriesosdick J et al (2024) Minimizing contrast media dose in CT pulmonary angiography with clinical photon counting using high pitch technique. Acad Radiol 31:315\u2013321","journal-title":"Acad Radiol"},{"key":"12829_CR30","doi-asserted-by":"publisher","first-page":"2715","DOI":"10.3390\/diagnostics12112715","volume":"12","author":"T Yalynska","year":"2022","unstructured":"Yalynska T, Polacin M, Frauenfelder T, Martini K (2022) Impact of photon counting detector CT derived virtual monoenergetic images on the diagnosis of pulmonary embolism. Diagnostics 12:2715","journal-title":"Diagnostics"},{"key":"12829_CR31","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","volume":"104","author":"J Greffier","year":"2023","unstructured":"Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S (2023) Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging 104:167\u2013177","journal-title":"Diagn Interv Imaging"},{"key":"12829_CR32","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1148\/radiol.2019192094","volume":"294","author":"MS Davenport","year":"2020","unstructured":"Davenport MS, Perazella MA, Yee J et al (2020) Use of intravenous iodinated contrast media in patients with kidney disease: consensus statements from the American College of Radiology and the National Kidney Foundation. Radiology 294:660\u2013668","journal-title":"Radiology"},{"key":"12829_CR33","doi-asserted-by":"crossref","unstructured":"Khong PL, Ringertz H, Donoghue V et al (2013) Radiological protection in paediatric diagnostic and interventional radiology. ICRP Publication 121. Ann ICRP 42:1\u201363","DOI":"10.1016\/j.icrp.2012.10.001"},{"key":"12829_CR34","doi-asserted-by":"publisher","first-page":"3923","DOI":"10.1002\/sim.7411","volume":"36","author":"D Jackson","year":"2017","unstructured":"Jackson D, Law M, R\u00fccker G, Schwarzer G (2017) The Hartung-Knapp modification for random-effects meta-analysis: a useful refinement but are there any residual concerns? Stat Med 36:3923\u20133934","journal-title":"Stat Med"},{"key":"12829_CR35","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2288-14-25","volume":"14","author":"J IntHout","year":"2014","unstructured":"IntHout J, Ioannidis JPA, Borm GF (2014) The Hartung-Knapp-Sidik-Jonkman method for random effects meta-analysis is straightforward and considerably outperforms the standard DerSimonian-Laird method. BMC Med Res Methodol 14:25","journal-title":"BMC Med Res Methodol"},{"key":"12829_CR36","doi-asserted-by":"publisher","first-page":"680","DOI":"10.2967\/jnumed.106.039438","volume":"48","author":"N Tunariu","year":"2007","unstructured":"Tunariu N, Gibbs SJ, Win Z et al (2007) Ventilation-perfusion scintigraphy is more sensitive than multidetector CTPA in detecting chronic thromboembolic pulmonary disease as a treatable cause of pulmonary hypertension. J Nucl Med 48:680\u2013684","journal-title":"J Nucl Med"},{"key":"12829_CR37","doi-asserted-by":"publisher","first-page":"1801915","DOI":"10.1183\/13993003.01915-2018","volume":"53","author":"NH Kim","year":"2019","unstructured":"Kim NH, Delcroix M, Jais X et al (2019) Chronic thromboembolic pulmonary hypertension. Eur Respir J 53:1801915","journal-title":"Eur Respir J"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12829-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-026-12829-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12829-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T19:30:56Z","timestamp":1793043056000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-026-12829-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,24]]},"references-count":37,"alternative-id":["12829"],"URL":"https:\/\/doi.org\/10.1007\/s00330-026-12829-5","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,24]]},"assertion":[{"value":"23 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2026","order":6,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":7,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"In this article, ref. 13 was incorrect and should have been \u2018Schwartz FR, Khanungwanitkul K, Czajkowski B et al (2026) Optimizing photon-counting CT pulmonary angiography for robustness, combining mixed bolus, fixed scan delay and low keV. Eur J Radiol 195:112540\u2019.","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The scientific guarantor of this publication is Shingo Kato.","order":1,"name":"Ethics","label":"Guarantor","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"One of the authors (S.K.) has significant statistical expertise. No complex statistical methods were necessary for this paper.","order":3,"name":"Ethics","label":"Statistics and biometry","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Written informed consent was not required for this study because it is a systematic review and meta-analysis of previously published studies and includes no individual patient data.","order":4,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Institutional Review Board approval was not required because this study is a systematic review and meta-analysis of published literature involving no primary data collection or direct patient contact.","order":5,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"No study subjects or cohorts have been previously reported.","order":6,"name":"Ethics","label":"Study subjects or cohorts overlap","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"order":7,"name":"Ethics","label":"Methodology","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}}]}}