{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T18:10:06Z","timestamp":1789755006189,"version":"4.0.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Photon-counting CT (PCCT) enables dose reduction beyond energy-integrating CT, but ultra-low-dose acquisitions may impair assessment of airways and lung parenchyma. We evaluated the impact of ultra-low-dose (ULD) PCCT on quantitative and qualitative lung parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this prospective study, 101 patients underwent same-session low-dose (LD) and ULD chest CT for mixed indications (CTDIvol, 0.64\u2009\u00b1\u20090.15 vs. 0.11\u2009\u00b1\u20090.03 mGy). Automated QCT assessed noise index, airway segmentation, airway wall percentage, emphysema index (EI), mean lung density (MLD), and Percentile15 (Perc15) on soft (Br36u) and lung (Bl64u) kernels. Two readers scored image quality, airways, and emphysema extent using Likert scales.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      ULD increased noise compared with LD (Bl64u: +94.4%; Br36u: +32.8%) and reduced visual image quality (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Automated airway segmentation decreased (\u221241.4 mean no. of branches,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), with fewer visible airway generations (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Visual bronchial wall thickening did not differ (R1\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.89; R2\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.20). Airway wall percentage showed kernel- and generation-dependent differences: whole-tree values did not differ on Br36u (LD\u2013ULD\u2009\u22120.05%;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.83) but were higher at ULD on Bl64u (LD\u2013ULD\u2009\u22123.33%;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), with greater differences peripherally. At ULD, MLD and Perc15 were lower than at LD by 12.5 and 19.9 HU, respectively (both\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), while EI was 6.2% higher. Visual emphysema assessment shifted toward lower severity at ULD (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>ULD-PCCT enables dose-efficient QCT but introduces limitations: reduced peripheral airway visibility\/segmentation with differences in airway wall measurements, biased density-based emphysema quantification, and visual emphysema underestimation at ULD, supporting dose-aware interpretation and further validation of correction strategies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key Points<\/jats:title>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Question<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>To study the influence of ultra-low-dose photon-counting chest CT on quantitative and qualitative airway and emphysema assessment compared to low-dose CT<\/jats:italic>\n                      .\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Findings<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>Ultra-low-dose increased noise and reduced peripheral airway segmentation; airway wall metrics showed kernel- and generation-dependent differences, with biased density-based and visual emphysema assessment<\/jats:italic>\n                      .\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        <jats:italic>Clinical relevance<\/jats:italic>\n                      <\/jats:bold>\n                      <jats:italic>PCCT enables quantitative lung imaging at ultra-low dose, but dose reduction alters airway segmentation and density-based emphysema metrics. ULD-derived QCT therefore requires cautious interpretation and validation of dose-aware correction strategies before routine clinical use<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00330-026-12887-9","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:46:25Z","timestamp":1789753585000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Quantitative and qualitative lung parameters in photon-counting CT: comparison of ultra-low-dose with standard low-dose protocols"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1225-3016","authenticated-orcid":false,"given":"Jonas","family":"Kroschke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lisa","family":"Jungblut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oyunbileg","family":"von Stackelberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Falko","family":"Ensle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bjarne","family":"Kerber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans-Ulrich","family":"Kauczor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Frauenfelder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark Oliver","family":"Wielp\u00fctz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Weinheimer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"key":"12887_CR1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222786","volume":"307","author":"D Baraghoshi","year":"2023","unstructured":"Baraghoshi D, Strand M, Humphries SM et al (2023) Quantitative CT evaluation of emphysema progression over 10 years in the COPDGene study. Radiology 307:e222786","journal-title":"Radiology"},{"key":"12887_CR2","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.chest.2019.06.015","volume":"157","author":"J Park","year":"2020","unstructured":"Park J, Hobbs BD, Crapo JD et al (2020) Subtyping COPD by using visual and quantitative CT imaging features. Chest 157:47\u201360","journal-title":"Chest"},{"key":"12887_CR3","doi-asserted-by":"publisher","first-page":"2502","DOI":"10.1007\/s00330-019-06577-y","volume":"30","author":"P Konietzke","year":"2020","unstructured":"Konietzke P, Wielp\u00fctz MO, Wagner WL et al (2020) Quantitative CT detects progression in COPD patients with severe emphysema in a 3-month interval. Eur Radiol 30:2502\u20132512","journal-title":"Eur Radiol"},{"key":"12887_CR4","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2023.1184784","volume":"10","author":"P Konietzke","year":"2023","unstructured":"Konietzke P, Brunner C, Konietzke M et al (2023) GOLD stage-specific phenotyping of emphysema and airway disease using quantitative computed tomography. Front Med 10:1184784","journal-title":"Front Med"},{"key":"12887_CR5","first-page":"133","volume":"104","author":"P Konietzke","year":"2025","unstructured":"Konietzke P, Weinheimer O, Triphan SMF et al (2025) GOLD-grade specific disease characterization and phenotyping of COPD using quantitative computed tomography in the nationwide COSYCONET multicenter trial in Germany. Respiration 104:133\u2013150","journal-title":"Respiration"},{"key":"12887_CR6","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1148\/radiol.2015141579","volume":"277","author":"DA Lynch","year":"2015","unstructured":"Lynch DA, Austin JHM, Hogg JC et al (2015) CT-definable subtypes of chronic obstructive pulmonary disease: a statement of the Fleischner Society. Radiology 277:192\u2013205","journal-title":"Radiology"},{"key":"12887_CR7","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1136\/thoraxjnl-2013-203601","volume":"69","author":"PJ Castaldi","year":"2014","unstructured":"Castaldi PJ, Dy J, Ross J et al (2014) Cluster analysis in the COPDGene study identifies subtypes of smokers with distinct patterns of airway disease and emphysema. Thorax 69:415\u2013422","journal-title":"Thorax"},{"key":"12887_CR8","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/S2213-2600(21)00511-7","volume":"10","author":"D Adeloye","year":"2022","unstructured":"Adeloye D, Song P, Zhu Y et al (2022) Global, regional, and national prevalence of, and risk factors for, chronic obstructive pulmonary disease (COPD) in 2019: a systematic review and modelling analysis. Lancet Respir Med 10:447\u2013458","journal-title":"Lancet Respir Med"},{"key":"12887_CR9","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1164\/rccm.202301-0106PP","volume":"207","author":"A Agusti","year":"2023","unstructured":"Agusti A, Celli BR, Criner GJ et al (2023) Global Initiative for Chronic Obstructive Lung Disease 2023 report: GOLD executive summary. Am J Respir Crit Care Med 207:819\u2013837","journal-title":"Am J Respir Crit Care Med"},{"key":"12887_CR10","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.250949","volume":"316","author":"J Gonzalez Gutierrez","year":"2025","unstructured":"Gonzalez Gutierrez J, Yip R, Zulueta JJ et al (2025) Emphysema at baseline low-dose CT lung cancer screening predicts death from chronic obstructive pulmonary disease and cardiovascular disease up to 25 years later. Radiology 316:e250949","journal-title":"Radiology"},{"key":"12887_CR11","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1007\/s00330-012-2683-z","volume":"23","author":"Z Wang","year":"2013","unstructured":"Wang Z, Gu S, Leader JK et al (2013) Optimal threshold in CT quantification of emphysema. Eur Radiol 23:975\u2013984","journal-title":"Eur Radiol"},{"key":"12887_CR12","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1007\/s00330-011-2237-9","volume":"22","author":"OM Mets","year":"2012","unstructured":"Mets OM, Murphy K, Zanen P et al (2012) The relationship between lung function impairment and quantitative computed tomography in chronic obstructive pulmonary disease. Eur Radiol 22:120\u2013128","journal-title":"Eur Radiol"},{"key":"12887_CR13","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s12931-019-1047-5","volume":"20","author":"N Tanabe","year":"2019","unstructured":"Tanabe N, Sato S, Oguma T et al (2019) Associations of airway tree to lung volume ratio on computed tomography with lung function and symptoms in chronic obstructive pulmonary disease. Respir Res 20:77","journal-title":"Respir Res"},{"key":"12887_CR14","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1148\/radiol.2017162587","volume":"285","author":"R Symons","year":"2017","unstructured":"Symons R, Pourmorteza A, Sandfort V et al (2017) Feasibility of dose-reduced chest CT with photon-counting detectors: initial results in humans. Radiology 285:980\u2013989","journal-title":"Radiology"},{"key":"12887_CR15","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1097\/RLI.0000000000000895","volume":"57","author":"L Jungblut","year":"2022","unstructured":"Jungblut L, Euler A, von Spiczak J et al (2022) Potential of photon-counting detector CT for radiation dose reduction for the assessment of interstitial lung disease in patients with systemic sclerosis. Invest Radiol 57:773\u2013779","journal-title":"Invest Radiol"},{"key":"12887_CR16","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/RLI.0000000000000814","volume":"57","author":"L Jungblut","year":"2022","unstructured":"Jungblut L, Bl\u00fcthgen C, Polacin M et al (2022) First performance evaluation of an artificial intelligence-based computer-aided detection system for pulmonary nodule evaluation in dual-source photon-counting detector CT at different low-dose levels. Invest Radiol 57:108\u2013114","journal-title":"Invest Radiol"},{"key":"12887_CR17","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1097\/RLI.0000000000000968","volume":"58","author":"M Remy-Jardin","year":"2023","unstructured":"Remy-Jardin M, Hutt A, Flohr T et al (2023) Ultra-high-resolution photon-counting CT imaging of the chest: a new era for morphology and function. Invest Radiol 58:482\u2013487","journal-title":"Invest Radiol"},{"key":"12887_CR18","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1097\/RLI.0000000000001128","volume":"60","author":"B Kerber","year":"2025","unstructured":"Kerber B, Ensle F, Kroschke J et al (2025) Assessment of emphysema on X-ray equivalent dose photon-counting detector CT: evaluation of visual scoring and automated quantification algorithms. Invest Radiol 60:291\u2013298","journal-title":"Invest Radiol"},{"key":"12887_CR19","doi-asserted-by":"publisher","unstructured":"Kerber B, Ensle F, Kroschke J et al (2025) The effect of X-ray dose photon-counting detector computed tomography on nodule properties in a lung cancer screening cohort: a prospective study. Invest Radiol 60:627\u2013635. https:\/\/doi.org\/10.1097\/rli.0000000000001174","DOI":"10.1097\/rli.0000000000001174"},{"key":"12887_CR20","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1097\/RLI.0000000000001199","volume":"61","author":"J Kroschke","year":"2026","unstructured":"Kroschke J, Kerber B, Eberhard M, Ensle F, Frauenfelder T, Jungblut L (2026) Photon-counting chest CT at radiography-comparable dose levels: impact on opportunistic visual and semiautomated coronary calcium quantification. Invest Radiol 61:41\u201348","journal-title":"Invest Radiol"},{"key":"12887_CR21","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1097\/RCT.0000000000001419","volume":"47","author":"A Inoue","year":"2023","unstructured":"Inoue A, Johnson TF, Walkoff LA et al (2023) Lung cancer screening using clinical photon-counting detector computed tomography and energy-integrating-detector computed tomography: a prospective patient study. J Comput Assist Tomogr 47:229\u2013235","journal-title":"J Comput Assist Tomogr"},{"key":"12887_CR22","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1513\/pats.200804-033QC","volume":"5","author":"A Dirksen","year":"2008","unstructured":"Dirksen A (2008) Monitoring the progress of emphysema by repeat computed tomography scans with focus on noise reduction. Proc Am Thorac Soc 5:925\u2013928","journal-title":"Proc Am Thorac Soc"},{"key":"12887_CR23","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","volume":"17","author":"P Virtanen","year":"2020","unstructured":"Virtanen P, Gommers R, Oliphant TE et al (2020) SciPy 1.0: fundamental algorithms for scientific computing in Python. Nat Methods 17:261\u2013272","journal-title":"Nat Methods"},{"key":"12887_CR24","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174","journal-title":"Biometrics"},{"key":"12887_CR25","doi-asserted-by":"crossref","unstructured":"Bayfield KJ, Weinheimer O, Boyton C et al (2023) Implementation and evaluation of ultra-low dose CT in early cystic fibrosis lung disease. Eur Respir J 62:2300286","DOI":"10.1183\/13993003.00286-2023"},{"key":"12887_CR26","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1164\/ajrccm.152.2.7633722","volume":"152","author":"PA Gevenois","year":"1995","unstructured":"Gevenois PA, de Maertelaer V, De Vuyst P, Zanen J, Yernault JC (1995) Comparison of computed density and macroscopic morphometry in pulmonary emphysema. Am J Respir Crit Care Med 152:653\u2013657","journal-title":"Am J Respir Crit Care Med"},{"key":"12887_CR27","doi-asserted-by":"publisher","first-page":"3781","DOI":"10.1007\/s00330-024-11254-w","volume":"35","author":"RE Ledda","year":"2025","unstructured":"Ledda RE, Milanese G, Balbi M et al (2025) Coronary calcium score and emphysema extent on different CT radiation dose protocols in lung cancer screening. Eur Radiol 35:3781\u20133787","journal-title":"Eur Radiol"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12887-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-026-12887-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12887-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:46:27Z","timestamp":1789753587000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-026-12887-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":27,"alternative-id":["12887"],"URL":"https:\/\/doi.org\/10.1007\/s00330-026-12887-9","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]},"assertion":[{"value":"31 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The scientific guarantor of this publication is Oliver Weinheimer.","order":1,"name":"Ethics","label":"Guarantor","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"One of the authors has significant statistical expertise.","order":3,"name":"Ethics","label":"Statistics and biometry","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Written informed consent was obtained from all subjects (patients) in this study.","order":4,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Institutional Review Board approval was obtained.","order":5,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Some study subjects or cohorts have been previously reported in: Kroschke et al [\n                      \n                      ], Kerber et al [\n                      \n                      ], Kerber et al [\n                      \n                      ].","order":6,"name":"Ethics","label":"Study subjects or cohorts overlap","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"order":7,"name":"Ethics","label":"Methodology","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}}]}}