{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T02:53:22Z","timestamp":1790909602582,"version":"4.1.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Radiol"],"DOI":"10.1007\/s00330-026-12906-9","type":"journal-article","created":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T02:05:23Z","timestamp":1790906723000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Angio-CT does not increase patient radiation exposure compared to conventional cone-beam CT for intra-arterial liver procedures"],"prefix":"10.1007","author":[{"given":"Charlotte","family":"Schneider","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han","family":"Keijzers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik Jan","family":"Rijkhorst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth","family":"Hergaarden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarik","family":"Baetens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Regina","family":"Beets-Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Belinda","family":"de Wit-van der Veen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4497-3838","authenticated-orcid":false,"given":"Elisabeth","family":"Klompenhouwer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,2]]},"reference":[{"key":"12906_CR1","doi-asserted-by":"publisher","first-page":"e210039","DOI":"10.1148\/rycan.2021210039","volume":"3","author":"R Taiji","year":"2021","unstructured":"Taiji R, Lin EY, Lin Y-M et al (2021) Combined angio-CT systems: a roadmap tool for precision therapy in interventional oncology. Radiol Imaging Cancer 3:e210039. https:\/\/doi.org\/10.1148\/rycan.2021210039","journal-title":"Radiol Imaging Cancer"},{"key":"12906_CR2","doi-asserted-by":"publisher","first-page":"955","DOI":"10.2214\/ajr.174.4.1740955","volume":"174","author":"Y Inaba","year":"2000","unstructured":"Inaba Y, Arai Y, Kanematsu M et al (2000) Revealing hepatic metastases from colorectal cancer: value of combined helical CT during arterial portography and CT hepatic arteriography with a unified CT and angiography system. AJR Am J Roentgenol 174:955\u2013961. https:\/\/doi.org\/10.2214\/ajr.174.4.1740955","journal-title":"AJR Am J Roentgenol"},{"key":"12906_CR3","doi-asserted-by":"publisher","first-page":"2850","DOI":"10.1007\/s00261-020-02914-8","volume":"46","author":"A Lionberg","year":"2021","unstructured":"Lionberg A, Nijhawan K, Navuluri R et al (2021) Hybrid angiography-CT for transarterial radioembolization: a pictorial essay. Abdom Radiol 46:2850\u20132854. https:\/\/doi.org\/10.1007\/s00261-020-02914-8","journal-title":"Abdom Radiol"},{"key":"12906_CR4","doi-asserted-by":"publisher","first-page":"761","DOI":"10.1016\/j.jvir.2025.01.032","volume":"36","author":"DM Rivera Rodr\u00edguez","year":"2025","unstructured":"Rivera Rodr\u00edguez DM, Goyal P, Varadhan AK et al (2025) Utility of hybrid angiography-CT in interventional radiology: case-based examples. J Vasc Interv Radiol JVIR 36:761\u2013767. https:\/\/doi.org\/10.1016\/j.jvir.2025.01.032","journal-title":"J Vasc Interv Radiol JVIR"},{"key":"12906_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-020-00515-x","volume":"20","author":"JP Erinjeri","year":"2020","unstructured":"Erinjeri JP, Doustaly R, Avignon G et al (2020) Utilization of integrated angiography-CT interventional radiology suites at a tertiary cancer center. BMC Med Imaging 20:114. https:\/\/doi.org\/10.1186\/s12880-020-00515-x","journal-title":"BMC Med Imaging"},{"key":"12906_CR6","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/s00270-018-2116-8","volume":"42","author":"EY Lin","year":"2019","unstructured":"Lin EY, Jones AK, Chintalapani G et al (2019) Comparative analysis of intra-arterial cone-beam versus conventional computed tomography during hepatic arteriography for transarterial chemoembolization planning. Cardiovasc Intervent Radiol 42:591\u2013600. https:\/\/doi.org\/10.1007\/s00270-018-2116-8","journal-title":"Cardiovasc Intervent Radiol"},{"key":"12906_CR7","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00270-023-03508-9","volume":"46","author":"S van der Lei","year":"2023","unstructured":"van der Lei S, Opperman J, Dijkstra M et al (2023) The added diagnostic value of transcatheter CT hepatic arteriography for intraprocedural detection of previously unknown colorectal liver metastases during percutaneous ablation and impact on the definitive treatment plan. Cardiovasc Intervent Radiol 46:1257\u20131266. https:\/\/doi.org\/10.1007\/s00270-023-03508-9","journal-title":"Cardiovasc Intervent Radiol"},{"key":"12906_CR8","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.jvir.2020.10.021","volume":"32","author":"EL Marshall","year":"2021","unstructured":"Marshall EL, Guajardo S, Sellers E et al (2021) Radiation dose during transarterial radioembolization: a dosimetric comparison of cone-beam CT and angio-CT technologies. J Vasc Interv Radiol JVIR 32:429\u2013438. https:\/\/doi.org\/10.1016\/j.jvir.2020.10.021","journal-title":"J Vasc Interv Radiol JVIR"},{"key":"12906_CR9","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1007\/s00270-019-02269-8","volume":"42","author":"L Piron","year":"2019","unstructured":"Piron L, Le Roy J, Cassinotto C et al (2019) Radiation exposure during transarterial chemoembolization: angio-CT versus cone-beam CT. Cardiovasc Intervent Radiol 42:1609\u20131618. https:\/\/doi.org\/10.1007\/s00270-019-02269-8","journal-title":"Cardiovasc Intervent Radiol"},{"key":"12906_CR10","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1016\/j.jvir.2020.05.011","volume":"31","author":"RS Puijk","year":"2020","unstructured":"Puijk RS, Nieuwenhuizen S, van den Bemd BAT et al (2020) Transcatheter CT hepatic arteriography compared with conventional CT fluoroscopy guidance in percutaneous thermal ablation to treat colorectal liver metastases: a single-center comparative analysis of 2 historical cohorts. J Vasc Interv Radiol JVIR 31:1772\u20131783. https:\/\/doi.org\/10.1016\/j.jvir.2020.05.011","journal-title":"J Vasc Interv Radiol JVIR"},{"key":"12906_CR11","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.232128","volume":"310","author":"A LaBella","year":"2024","unstructured":"LaBella A, Kim D-S, Chow JS et al (2024) Age-specific dose catalog for diagnostic fluoroscopy and fluoroscopically guided interventional procedures from a pediatric hospital. Radiology 310:e232128. https:\/\/doi.org\/10.1148\/radiol.232128","journal-title":"Radiology"},{"key":"12906_CR12","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-018-0247-7","volume":"18","author":"Y-S Hwang","year":"2018","unstructured":"Hwang Y-S, Tsai H-Y, Lin Y-Y, Lui K-W (2018) Investigations of organ and effective doses of abdominal cone-beam computed tomography during transarterial chemoembolization using Monte Carlo simulation. BMC Med Imaging 18:2. https:\/\/doi.org\/10.1186\/s12880-018-0247-7","journal-title":"BMC Med Imaging"},{"key":"12906_CR13","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1148\/radiol.10100047","volume":"257","author":"PD Deak","year":"2010","unstructured":"Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158\u2013166. https:\/\/doi.org\/10.1148\/radiol.10100047","journal-title":"Radiology"},{"key":"12906_CR14","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1259\/bjr\/25922439","volume":"80","author":"CJ Martin","year":"2007","unstructured":"Martin CJ (2007) Effective dose: How should it be applied to medical exposures? Br J Radiol 80:639\u2013647. https:\/\/doi.org\/10.1259\/bjr\/25922439","journal-title":"Br J Radiol"},{"key":"12906_CR15","doi-asserted-by":"publisher","unstructured":"Ketelhut S, Kuhlmann M-L, B\u00fcermann L et al (2023) Simulation study on the conversion between CT and CBCT dose quantities via the effective dose. Biomed Phys Eng Express. https:\/\/doi.org\/10.1088\/2057-1976\/ad065e","DOI":"10.1088\/2057-1976\/ad065e"},{"key":"12906_CR16","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1002\/acm2.12808","volume":"21","author":"AK Jones","year":"2020","unstructured":"Jones AK, Odisio BC (2020) Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite. J Appl Clin Med Phys 21:121\u2013127. https:\/\/doi.org\/10.1002\/acm2.12808","journal-title":"J Appl Clin Med Phys"}],"container-title":["European Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12906-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00330-026-12906-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00330-026-12906-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T02:05:24Z","timestamp":1790906724000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00330-026-12906-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,2]]},"references-count":16,"alternative-id":["12906"],"URL":"https:\/\/doi.org\/10.1007\/s00330-026-12906-9","relation":{},"ISSN":["1432-1084"],"issn-type":[{"value":"1432-1084","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,2]]},"assertion":[{"value":"1 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The scientific guarantor of this publication is EG Klompenhouwer.","order":1,"name":"Ethics","label":"Guarantor","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Dr. Terry Chan from the Netherlands Cancer Institute has kindly provided statistical advice for this manuscript.","order":3,"name":"Ethics","label":"Statistics and biometry","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Written informed consent was waived by the Institutional Review Board.","order":4,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Institutional Review Board approval was obtained.","order":5,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"No study subjects or cohorts have been previously reported.","order":6,"name":"Ethics","label":"Study subjects or cohorts overlap","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"order":7,"name":"Ethics","label":"Methodology","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}}]}}