{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T16:51:11Z","timestamp":1792601471252,"version":"4.5.0"},"reference-count":60,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,13]],"date-time":"2019-02-13T00:00:00Z","timestamp":1550016000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000833","name":"Rosetrees Trust","doi-asserted-by":"crossref","award":["M537"],"award-info":[{"award-number":["M537"]}],"id":[{"id":"10.13039\/501100000833","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["World J Urol"],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1007\/s00345-019-02679-w","type":"journal-article","created":{"date-parts":[[2019,2,13]],"date-time":"2019-02-13T13:22:25Z","timestamp":1550064145000},"page":"73-80","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":90,"title":["Complications related to use of mesh implants in surgical treatment of stress urinary incontinence and pelvic organ prolapse: infection or inflammation?"],"prefix":"10.1007","volume":"38","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3062-6480","authenticated-orcid":false,"given":"Na\u015fide","family":"Mangir","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabiniano","family":"Roman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher R.","family":"Chapple","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheila","family":"MacNeil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,13]]},"reference":[{"key":"2679_CR1","unstructured":"Medsafe. Medsafe introduces surgical mesh restrictions. \nhttps:\/\/www.health.govt.nz\/news-media\/media-releases\/medsafe-introduces-surgical-mesh-restrictions\n\n. Accessed 23 Feb 2018)"},{"key":"2679_CR2","unstructured":"Update on the Independent Medicines and Medical Devices Safety Review: Written statement\u2014HCWS841\u2014UK Parliament. \nhttps:\/\/www.parliament.uk\/business\/publications\/written-questions-answers-statements\/written-statement\/Commons\/2018-07-10\/HCWS841\n\n. Accessed 26 Aug 2018)"},{"key":"2679_CR3","unstructured":"The British Society of Urogynaecology 27 Sussex Place, London, NW1 4RG. Available at: \nhttps:\/\/bsug.org.uk\/news-details\/vaginal-mesh-high-vigilance-restriction-period\/76\/0\/0\n\n. Accessed 26 Aug 2018"},{"key":"2679_CR4","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1001\/jama.1947.02890020012005","volume":"135","author":"FD Ingraham","year":"1947","unstructured":"Ingraham FD, Alexander E, Matson DD (1947) Polyethylene, a new synthetic plastic for use in surgery; experimental applications in neurosurgery. J Am Med Assoc 135:82\u201387","journal-title":"J Am Med Assoc"},{"key":"2679_CR5","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1016\/S0039-6109(05)70365-0","volume":"78","author":"JR DeBord","year":"1998","unstructured":"DeBord JR (1998) The historical development of prosthetics in Hernia surgery. Surg Clin North Am 78:973\u20131006","journal-title":"Surg Clin North Am"},{"key":"2679_CR6","unstructured":"Marsden H. Vaginal mesh campaigner \u2018dies of sepsis after antibiotic-resistant infection\u2019| The Independent. Newspaper article accessed on 11 Dec 2018. \nhttps:\/\/www.independent.co.uk\/news\/uk\/transvaginal-vaginal-mesh-surgery-stress-urinary-incontinence-sui-uti-tvt-antiobiotic-resistance-a8092006.html"},{"key":"2679_CR7","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1111\/j.1464-410X.2004.04910.x","volume":"94","author":"R Abouassaly","year":"2004","unstructured":"Abouassaly R et al (2004) Complications of tension-free vaginal tape surgery: a multi-institutional review. BJU Int 94:110\u2013113","journal-title":"BJU Int"},{"key":"2679_CR8","doi-asserted-by":"publisher","first-page":"1859","DOI":"10.1007\/s00192-013-2177-9","volume":"24","author":"R Tayrac de","year":"2013","unstructured":"de Tayrac R, Sentilhes L (2013) Complications of pelvic organ prolapse surgery and methods of prevention. Int Urogynecol J 24:1859\u20131872","journal-title":"Int Urogynecol J"},{"key":"2679_CR9","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ejogrb.2007.02.024","volume":"134","author":"ME Falagas","year":"2007","unstructured":"Falagas ME, Velakoulis S, Iavazzo C, Athanasiou S (2007) Mesh-related infections after pelvic organ prolapse repair surgery. Eur J Obstet Gynecol Reprod Biol 134:147\u2013156","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"2679_CR10","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1097\/SPV.0000000000000246","volume":"22","author":"EM Mellano","year":"2016","unstructured":"Mellano EM et al (2016) The role of chronic mesh infection in delayed-onset vaginal mesh complications or recurrent urinary tract infections. Female Pelvic Med Reconstr Surg 22:166\u2013171","journal-title":"Female Pelvic Med Reconstr Surg"},{"key":"2679_CR11","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.cps.2008.08.007","volume":"36","author":"WP Adams","year":"2009","unstructured":"Adams WP (2009) Capsular contracture: what is it? What causes it? How can it be prevented and managed? Clin Plast Surg 36:119\u2013126 (vii)","journal-title":"Clin Plast Surg"},{"key":"2679_CR12","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1007\/s00266-009-9333-0","volume":"33","author":"UM Rieger","year":"2009","unstructured":"Rieger UM, Pierer G, L\u00fcscher NJ, Trampuz A (2009) Sonication of Removed Breast Implants for Improved Detection of Subclinical Infection. Aesthetic Plast Surg 33:404\u2013408","journal-title":"Aesthetic Plast Surg"},{"key":"2679_CR13","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1097\/00006250-196207000-00009","volume":"20","author":"FE Lane","year":"1962","unstructured":"Lane FE (1962) Repair of posthysterectomy vaginal-vault prolapse. Obstet Gynecol 20:72\u201377","journal-title":"Obstet Gynecol"},{"issue":"3","key":"2679_CR14","doi-asserted-by":"publisher","first-page":"1101","DOI":"10.1002\/nau.23425","volume":"37","author":"C Wang","year":"2017","unstructured":"Wang C, Christie AL, Zimmern PE (2018) Long-term occurrence of secondary compartment pelvic organ prolapse after open mesh sacrocolpopexy for symptomatic prolapse. Neurourol Urodyn 37(3):1101\u20131105. \nhttps:\/\/doi.org\/10.1002\/nau.23425","journal-title":"Neurourol Urodyn"},{"key":"2679_CR15","doi-asserted-by":"publisher","first-page":"688 e1","DOI":"10.1016\/j.ajog.2008.07.029","volume":"199","author":"GW Cundiff","year":"2008","unstructured":"Cundiff GW et al (2008) Risk factors for mesh\/suture erosion following sacral colpopexy. Am J Obstet Gynecol 199:688 e1\u2013688 e5","journal-title":"Am J Obstet Gynecol"},{"key":"2679_CR16","doi-asserted-by":"publisher","first-page":"2016","DOI":"10.1001\/jama.2013.4919","volume":"309","author":"I Nygaard","year":"2013","unstructured":"Nygaard I et al (2013) Long-term outcomes following abdominal sacrocolpopexy for pelvic organ prolapse. JAMA 309:2016\u20132024","journal-title":"JAMA"},{"key":"2679_CR17","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1016\/j.eururo.2009.01.048","volume":"55","author":"AM Ganatra","year":"2009","unstructured":"Ganatra AM et al (2009) The current status of laparoscopic sacrocolpopexy: a review. Eur Urol 55:1089\u20131105","journal-title":"Eur Urol"},{"key":"2679_CR18","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.jamcollsurg.2013.08.003","volume":"217","author":"RL Berger","year":"2013","unstructured":"Berger RL et al (2013) Development and validation of a risk-stratification score for surgical site occurrence and surgical site infection after open ventral hernia repair. J Am Coll Surg 217:974\u2013982","journal-title":"J Am Coll Surg"},{"key":"2679_CR19","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1007\/s00192-017-3512-3","volume":"29","author":"AL Milani","year":"2017","unstructured":"Milani AL, Damoiseaux A, IntHout J, Kluivers KB, Withagen MIJ (2017) Long-term outcome of vaginal mesh or native tissue in recurrent prolapse: a randomized controlled trial. Int Urogynecol J 29:847\u2013858. \nhttps:\/\/doi.org\/10.1007\/s00192-017-3512-3","journal-title":"Int Urogynecol J"},{"key":"2679_CR20","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD006375.pub3","author":"AA Ford","year":"2017","unstructured":"Ford AA, Rogerson L, Cody JD, Aluko P, Ogah JA (2017) Mid\u2010urethral sling operations for stress urinary incontinence in women. Cochrane Database Syst Rev. \nhttps:\/\/doi.org\/10.1002\/14651858.CD006375.pub3","journal-title":"Cochrane Database Syst Rev"},{"key":"2679_CR21","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1111\/j.1471-0528.2007.01548.x","volume":"115","author":"KL Ward","year":"2008","unstructured":"Ward KL, Hilton P, UK and Ireland TVT Trial Group (2008) Tension-free vaginal tape versus colposuspension for primary urodynamic stress incontinence: 5-year follow up. BJOG 115:226\u2013233","journal-title":"BJOG"},{"key":"2679_CR22","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/S0140-6736(16)31596-3","volume":"389","author":"CM Glazener","year":"2017","unstructured":"Glazener CM et al (2017) Mesh, graft, or standard repair for women having primary transvaginal anterior or posterior compartment prolapse surgery: two parallel-group, multicentre, randomised, controlled trials (PROSPECT). Lancet (London, England) 389:381\u2013392","journal-title":"Lancet (London, England)"},{"key":"2679_CR23","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1007\/s00192-009-1050-3","volume":"21","author":"N Marcus-Braun","year":"2010","unstructured":"Marcus-Braun N, von Theobald P (2010) Mesh removal following transvaginal mesh placement: a case series of 104 operations. Int Urogynecol J 21:423\u2013430","journal-title":"Int Urogynecol J"},{"key":"2679_CR24","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1038\/nrurol.2017.219","volume":"15","author":"S MacNeil","year":"2018","unstructured":"MacNeil S, El Neil S, Esegbona G, Damaser M (2018) Repairing the female pelvic floor: when good enough is not good enough. Nat Rev Urol 15:197\u2013198 \nhttps:\/\/doi.org\/10.1038\/nrurol.2017.219","journal-title":"Nat Rev Urol"},{"key":"2679_CR25","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1016\/S0142-9612(98)00115-X","volume":"19","author":"B Klosterhalfen","year":"1998","unstructured":"Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19:2235\u20132246","journal-title":"Biomaterials"},{"key":"2679_CR26","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.jss.2011.09.031","volume":"176","author":"SB Orenstein","year":"2012","unstructured":"Orenstein SB, Saberski ER, Kreutzer DL, Novitsky YW (2012) Comparative analysis of histopathologic effects of synthetic meshes based on material, weight, and pore size in mice. J Surg Res 176:423\u2013429","journal-title":"J Surg Res"},{"key":"2679_CR27","first-page":"247","volume":"10","author":"S Schmidbauer","year":"2005","unstructured":"Schmidbauer S, Ladurner R, Hallfeldt KK, Mussack T (2005) Heavy-weight versus low-weight polypropylene meshes for open sublay mesh repair of incisional hernia. Eur J Med Res 10:247\u2013253","journal-title":"Eur J Med Res"},{"key":"2679_CR28","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1002\/jbm.b.30859","volume":"84B","author":"T M\u00fchl","year":"2008","unstructured":"M\u00fchl T, Binneb\u00f6sel M, Klinge U, Goedderz T (2008) New objective measurement to characterize the porosity of textile implants. J Biomed Mater Res Part B Appl Biomater 84B:176\u2013183","journal-title":"J Biomed Mater Res Part B Appl Biomater"},{"key":"2679_CR29","doi-asserted-by":"publisher","first-page":"051005","DOI":"10.1115\/1.4039058","volume":"140","author":"KM Knight","year":"2018","unstructured":"Knight KM, Moalli PA, Abramowitch SD (2018) Preventing mesh pore collapse by designing mesh pores with auxetic geometries: a comprehensive evaluation via computational modeling. J Biomech Eng 140:051005","journal-title":"J Biomech Eng"},{"key":"2679_CR30","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/S0090-4295(99)00552-X","volume":"55","author":"JM Choe","year":"2000","unstructured":"Choe JM, Ogan K, Bennett S (2000) Antibacterial mesh sling: a prospective outcome analysis. Urology 55:515\u2013520","journal-title":"Urology"},{"key":"2679_CR31","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.ejogrb.2012.09.001","volume":"165","author":"X Deffieux","year":"2012","unstructured":"Deffieux X et al (2012) Prevention of complications related to the use of prosthetic meshes in prolapse surgery: guidelines for clinical practice. Eur J Obstet Gynecol Reprod Biol 165:170\u2013180","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"2679_CR32","doi-asserted-by":"crossref","unstructured":"Martinez FO, Gordon S (2014) The M1 and M2 paradigm of macrophage activation: time for reassessment. F1000prime reports 6","DOI":"10.12703\/P6-13"},{"issue":"668.e1","key":"2679_CR33","first-page":"668.e10","volume":"213","author":"BN Brown","year":"2015","unstructured":"Brown BN et al (2015) Characterization of the host inflammatory response following implantation of prolapse mesh in rhesus macaque. Am J Obstet Gynecol 213(668.e1):668.e10\u2013668.e11","journal-title":"Am J Obstet Gynecol"},{"key":"2679_CR34","doi-asserted-by":"publisher","first-page":"40","DOI":"10.5949\/UPO9781846314438","volume-title":"The Williams dictionary of biomaterials","author":"DF Williams","year":"1999","unstructured":"Williams DF, David F (1999) The Williams dictionary of biomaterials. Liverpool University Press, Liverpool, p 40"},{"key":"2679_CR35","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/s00192-006-0176-9","volume":"18","author":"R Tayrac de","year":"2007","unstructured":"de Tayrac R, Alves A, Th\u00e9rin M (2007) Collagen-coated vs noncoated low-weight polypropylene meshes in a sheep model for vaginal surgery. A pilot study. Int Urogynecol J Pelvic Floor Dysfunct 18:513\u2013520","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"2679_CR36","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1111\/1471-0528.12081","volume":"120","author":"S Manodoro","year":"2013","unstructured":"Manodoro S et al (2013) Graft-related complications and biaxial tensiometry following experimental vaginal implantation of flat mesh of variable dimensions. BJOG An Int J Obstet Gynaecol 120:244\u2013250","journal-title":"BJOG An Int J Obstet Gynaecol"},{"issue":"206","key":"2679_CR37","first-page":"e1","volume":"215","author":"AL Nolfi","year":"2016","unstructured":"Nolfi AL et al (2016) Host response to synthetic mesh in women with mesh complications. Am J Obstet Gynecol 215(206):e1\u2013e8","journal-title":"Am J Obstet Gynecol"},{"key":"2679_CR38","doi-asserted-by":"publisher","first-page":"179","DOI":"10.2165\/00003495-200565020-00003","volume":"65","author":"C Eiff von","year":"2005","unstructured":"von Eiff C, Jansen B, Kohnen W, Becker K (2005) Infections associated with medical devices. Drugs 65:179\u2013214","journal-title":"Drugs"},{"key":"2679_CR39","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1089\/sur.2014.026","volume":"16","author":"S Kathju","year":"2015","unstructured":"Kathju S, Nistico L, Melton-Kreft R, Lasko L-A, Stoodley P (2015) Direct demonstration of bacterial biofilms on prosthetic mesh after ventral herniorrhaphy. Surg Infect (Larchmt) 16:45\u201353","journal-title":"Surg Infect (Larchmt)"},{"key":"2679_CR40","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1002\/bjs.4451","volume":"91","author":"JM Bell\u00f3n","year":"2004","unstructured":"Bell\u00f3n JM, Garc\u00eda-Carranza A, Garc\u00eda-Honduvilla N, Carrera-San Mart\u00edn A, Buj\u00e1n J (2004) Tissue integration and biomechanical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants. Br J Surg 91:489\u2013494","journal-title":"Br J Surg"},{"key":"2679_CR41","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1038\/s41579-018-0019-y","volume":"16","author":"CR Arciola","year":"2018","unstructured":"Arciola CR, Campoccia D, Montanaro L (2018) Implant infections: adhesion, biofilm formation and immune evasion. Nat Rev Microbiol 16:397\u2013409","journal-title":"Nat Rev Microbiol"},{"key":"2679_CR42","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1093\/asj\/sjv177","volume":"36","author":"D Ajdic","year":"2016","unstructured":"Ajdic D, Zoghbi Y, Gerth D, Panthaki ZJ, Thaller S (2016) The relationship of bacterial biofilms and capsular contracture in breast implants. Aesthetic Surg J 36:297\u2013309","journal-title":"Aesthetic Surg J"},{"key":"2679_CR43","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1007\/s00192-009-1021-8","volume":"21","author":"A Clav\u00e9","year":"2010","unstructured":"Clav\u00e9 A et al (2010) Polypropylene as a reinforcement in pelvic surgery is not inert: comparative analysis of 100 explants. Int Urogynecol J 21:261\u2013270","journal-title":"Int Urogynecol J"},{"key":"2679_CR44","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/s00192-010-1245-7","volume":"22","author":"L Mamy","year":"2011","unstructured":"Mamy L et al (2011) Correlation between shrinkage and infection of implanted synthetic meshes using an animal model of mesh infection. Int Urogynecol J 22:47\u201352","journal-title":"Int Urogynecol J"},{"key":"2679_CR45","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s10029-009-0580-4","volume":"14","author":"M Binneb\u00f6sel","year":"2010","unstructured":"Binneb\u00f6sel M et al (2010) Impact of mesh positioning on foreign body reaction and collagenous ingrowth in a rabbit model of open incisional hernia repair. Hernia 14:71\u201377","journal-title":"Hernia"},{"key":"2679_CR46","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.eururo.2017.03.048","volume":"72","author":"CR Chapple","year":"2017","unstructured":"Chapple CR et al (2017) Consensus statement of the European urology association and the European urogynaecological association on the use of implanted materials for treating pelvic organ prolapse and stress urinary incontinence. Eur Urol 72:424\u2013431","journal-title":"Eur Urol"},{"key":"2679_CR47","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.ejogrb.2017.08.039","volume":"217","author":"A Robichaud","year":"2017","unstructured":"Robichaud A et al (2017) Avoidance of the vaginal incision site for mesh placement in vaginal wall prolapse surgery: a prospective study. Eur J Obstet Gynecol Reprod Biol 217:131\u2013136","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"issue":"1","key":"2679_CR48","first-page":"21","volume":"36","author":"V Leanza","year":"2015","unstructured":"Leanza V, Zangh\u00ec G, Vecchio R, Leanza G (2015) How to prevent mesh erosion in transobturator Tension-Free Incontinence Cystocoele Treatment (TICT): a comparative survey.\u00a0Il Giornale di chirurgia\u00a036(1):21","journal-title":"Il Giornale di chirurgia"},{"key":"2679_CR49","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s00192-009-0976-9","volume":"21","author":"BT Haylen","year":"2010","unstructured":"Haylen BT et al (2010) An international urogynecological association (IUGA)\/international continence society (ICS) joint report on the terminology for female pelvic floor dysfunction. Int Urogynecol J 21:5\u201326","journal-title":"Int Urogynecol J"},{"key":"2679_CR50","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1007\/978-3-319-63251-3_40","volume-title":"Management of Abdominal Hernias","author":"K. M. Coakley","year":"2018","unstructured":"Coakley KM, Heniford BT, Augenstein VA (2018) Abdominal wall mesh infections. In:\u00a0Management of abdominal hernias. Springer, Cham, pp 511\u2013518"},{"key":"2679_CR51","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1007\/s00192-007-0537-z","volume":"19","author":"L Boulanger","year":"2008","unstructured":"Boulanger L et al (2008) Bacteriological analysis of meshes removed for complications after surgical management of urinary incontinence or pelvic organ prolapse. Int Urogynecol J 19:827\u2013831","journal-title":"Int Urogynecol J"},{"key":"2679_CR52","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s00192-010-1330-y","volume":"22","author":"W Badiou","year":"2011","unstructured":"Badiou W et al (2011) In vitro and in vivo assessment of silver-coated polypropylene mesh to prevent infection in a rat model. Int Urogynecol J 22:265\u2013272","journal-title":"Int Urogynecol J"},{"key":"2679_CR53","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1002\/jbm.b.31973","volume":"100B","author":"V Letouzey","year":"2012","unstructured":"Letouzey V et al (2012) Is degradable antibiotic coating for synthetic meshes provide protection against experimental animal infection after fascia repair? J Biomed Mater Res Part B Appl Biomater 100B:471\u2013479","journal-title":"J Biomed Mater Res Part B Appl Biomater"},{"key":"2679_CR54","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1021\/bm8013473","volume":"10","author":"N Aumsuwan","year":"2009","unstructured":"Aumsuwan N, McConnell MS, Urban MW (2009) Tunable antimicrobial polypropylene surfaces: simultaneous attachment of penicillin (Gram\u2009+) and gentamicin (Gram\u2009\u2212). Biomacromol 10:623\u2013629","journal-title":"Biomacromol"},{"key":"2679_CR55","doi-asserted-by":"publisher","DOI":"10.1016\/j.euf.2017.05.004","author":"N Mang\u0131r","year":"2017","unstructured":"Mang\u0131r N, Hillary CJ, Chapple CR, MacNeil S (2017) Oestradiol-releasing biodegradable mesh stimulates collagen production and angiogenesis: an approach to improving biomaterial integration in pelvic floor repair. Eur Urol Focus. \nhttps:\/\/doi.org\/10.1016\/j.euf.2017.05.004","journal-title":"Eur Urol Focus"},{"key":"2679_CR56","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1002\/nau.23510","volume":"37","author":"S Shafaat","year":"2018","unstructured":"Shafaat S, Mangir N, Regureos SR, Chapple CR, MacNeil S (2018) Demonstration of improved tissue integration and angiogenesis with an elastic, estradiol releasing polyurethane material designed for use in pelvic floor repair. Neurourol Urodyn 37:716\u2013725. \nhttps:\/\/doi.org\/10.1002\/nau.23510","journal-title":"Neurourol Urodyn"},{"key":"2679_CR57","first-page":"224","volume":"120","author":"Lucie Hymp\u00e1nov\u00e1","year":"2018","unstructured":"Hymp\u00e1nov\u00e1 Lucie, Rynkevic Rita, Roman Sabiniano, MacNeil Sheila, Deprest J (2018) Assessing the mechanical and cellular responses to next generation meshes for pelvic floor repair in the sheep vagina compared to native tissue repair. Eur UrolFocus 120:224\u2013232 (in press)","journal-title":"Eur UrolFocus"},{"key":"2679_CR58","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1002\/mabi.201300561","volume":"14","author":"M Abrigo","year":"2014","unstructured":"Abrigo M, McArthur SL, Kingshott P (2014) Electrospun nanofibers as dressings for chronic wound care: advances, challenges, and future prospects. Macromol Biosci 14:772\u2013792","journal-title":"Macromol Biosci"},{"key":"2679_CR59","doi-asserted-by":"publisher","first-page":"7644","DOI":"10.1021\/acsami.5b00453","volume":"7","author":"M Abrigo","year":"2015","unstructured":"Abrigo M, Kingshott P, McArthur SL (2015) Electrospun polystyrene fiber diameter influencing bacterial attachment, proliferation, and growth. ACS Appl Mater Interfaces 7:7644\u20137652","journal-title":"ACS Appl Mater Interfaces"},{"key":"2679_CR60","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1177\/0885328216633373","volume":"30","author":"S Roman","year":"2016","unstructured":"Roman S, Mangir N, Bissoli J, Chapple CR, MacNeil S (2016) Biodegradable scaffolds designed to mimic fascia-like properties for the treatment of pelvic organ prolapse and stress urinary incontinence. J Biomater Appl 30:1578\u20131588","journal-title":"J Biomater Appl"}],"container-title":["World Journal of Urology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00345-019-02679-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00345-019-02679-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00345-019-02679-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T19:05:22Z","timestamp":1581534322000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00345-019-02679-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,13]]},"references-count":60,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["2679"],"URL":"https:\/\/doi.org\/10.1007\/s00345-019-02679-w","relation":{},"ISSN":["0724-4983","1433-8726"],"issn-type":[{"value":"0724-4983","type":"print"},{"value":"1433-8726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,13]]},"assertion":[{"value":"1 December 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"This work is conducted during a research project grant from The Rosetrees Trust, UK.\u00a0Dr. Roman is an employee of Symimetic. Authors have no relevant conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}