{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T18:35:25Z","timestamp":1778697325699,"version":"3.51.4"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T00:00:00Z","timestamp":1745971200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006302","name":"Universidad de Alcal\u00e1","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006302","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["World J Urol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Flexible cystoscopy is a widely performed urological procedure, with millions conducted annually. However, cystoscope contamination rates are relatively high, ranging from 2 to 21%, and infections may go undetected. Proper reprocessing of cystoscopes is a critical step in ensuring the safe use of these devices, which underscores the importance of studying it more thoroughly. The aim of this article is to describe the stages of cystoscope reprocessing in the Urology Department of a tertiary Hospital, identifying the potential failures of the system before they occur, quantifying its risks and recommending improvement actions to enhance overall safety and efficiency.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and methods<\/jats:title>\n                    <jats:p>This qualitative study was conducted using the Failure Mode and Effects Analysis methodology in different phases. First, data on structure, equipment and work processes were collected through direct observation and staff interviews. Then, processes and sub-processes were described along with their possible failures and underlying causes. Risks of this potential failures (failure modes) were quantified using the Risk Priority Number (RPN), calculated as the product of their frequency, severity and detectability. Improvement actions to mitigate failures with the highest NRP were proposed based on expert consensus and literature review.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Key findings and limitations<\/jats:title>\n                    <jats:p>9 processes and 11 sub-processes were identified, along with 16 failure modes. The key failure modes, those with an RPN\u2009&gt;\u2009100 included incorrect manual high-level disinfection, incorrect cleaning due to lack of brushing and lack of traceability. These failures were primarily caused by insufficient staff training, short intervals between procedures, and inadequate infrastructure. To address these issues, expert recommendations included providing comprehensive training for staff, improving reprocessing infrastructure by optimizing room layout, and ensuring an adequate supply of cystoscopes to reduce time constraints. Additionally, prioritizing automatic high-level disinfection and implementing a traceability system were proposed to enhance process reliability and patient safety.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Inadequate organizational structure and equipment can compromise patient safety during high-care activities. After analyzing cystoscope reprocessing at our center, three critical failure modes (NPR\u2009&gt;\u2009100) were identified: lack of traceability, improper cleaning due to insufficient brushing, and improper manual high-level disinfection (HLD). To address these issues, we proposed actions including improve staff training, increase the cystoscope supply, and enhance the unit\u2019s infrastructure. These findings may guide other healthcare professionals in improving reprocessing safety.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00345-025-05617-1","type":"journal-article","created":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T23:52:28Z","timestamp":1746057148000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Ensuring patient safety during cystocopy: risk assessment of device reprocessing through healthcare failure mode and effects analysis"],"prefix":"10.1007","volume":"43","author":[{"given":"Miriam Roncal","family":"Redin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina Diaz-Agero","family":"Perez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cornelia Bischofberger","family":"Valdes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego San","family":"Jose-Saras","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paloma","family":"Moreno-Nunez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge","family":"Vicente-Guijarro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jes\u00fas M.","family":"Aranaz-Andres","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,30]]},"reference":[{"key":"5617_CR1","unstructured":"Rindorf D, Ockert LK, Larsen S. The extent of experiencing availability issues and deteriorating performance associated with reusable cystoscopes, a multicentre study. European Urogynaecological Association conference poster."},{"key":"5617_CR2","unstructured":"Block SS. Disinfection, Sterilization, and Preservation. Lippincott Williams & Wilkins; 2001. 1448 p."},{"key":"5617_CR3","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.urology.2022.11.005","volume":"172","author":"J Chavarriaga","year":"2023","unstructured":"Chavarriaga J, Villanueva J, Varela D, Erazo S, Usubillaga MC, Erazo JC et al (2023) Do we need a urine culture before cystoscopy? time to shift away from routine testing. Urology 172:13\u201317","journal-title":"Urology"},{"key":"5617_CR4","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1016\/j.juro.2008.04.003","volume":"180","author":"AM Wendelboe","year":"2008","unstructured":"Wendelboe AM, Baumbach J, Blossom DB, Frank P, Srinivasan A, Sewell CM (2008) Outbreak of cystoscopy related infections with pseudomonas aeruginosa: new Mexico, 2007. J Urol 180:588\u2013592","journal-title":"J Urol"},{"key":"5617_CR5","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1590\/S1677-5538.IBJU.2014.0198","volume":"41","author":"HA Garc\u00eda-Perdomo","year":"2015","unstructured":"Garc\u00eda-Perdomo HA, Jim\u00e9nez-Mej\u00edas E, L\u00f3pez-Ramos H (2015) Efficacy of antibiotic prophylaxis in cystoscopy to prevent urinary tract infection: a systematic review and meta-analysis. Int Braz J Urol 41:412\u2013424","journal-title":"Int Braz J Urol"},{"key":"5617_CR6","first-page":"11361","volume":"29","author":"J Lee","year":"2022","unstructured":"Lee J, Kaplan-Marans E, Jivanji D, Tennenbaum D, Schulman A (2022) Post-cystoscopy infections and device malfunctions in reprocessed flexible cystoscopes in a national database. Can J Urol 29:11361\u201311365","journal-title":"Can J Urol"},{"key":"5617_CR7","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.juro.2014.07.015","volume":"193","author":"HW Herr","year":"2015","unstructured":"Herr HW (2015) The risk of urinary tract infection after flexible cystoscopy in patients with bladder tumor who did not receive prophylactic antibiotics. J Urol 193:548\u2013551","journal-title":"J Urol"},{"key":"5617_CR8","doi-asserted-by":"publisher","first-page":"1628","DOI":"10.3201\/eid2209.151440","volume":"22","author":"EE Sickbert-Bennett","year":"2016","unstructured":"Sickbert-Bennett EE, DiBiase LM, Willis TMS, Wolak ES, Weber DJ, Rutala WA (2016) Reduction of healthcare-associated infections by exceeding high compliance with hand hygiene practices. Emerg Infect Dis 22:1628\u20131630","journal-title":"Emerg Infect Dis"},{"key":"5617_CR9","volume":"30","author":"RADS Madureira","year":"2022","unstructured":"Madureira RADS, Oliveira ACD (2022) Cleaning of in-hospital flexible endoscopes: limitations and challenges. Rev Lat Am Enfermagem 30:e3684","journal-title":"Rev Lat Am Enfermagem"},{"key":"5617_CR10","doi-asserted-by":"publisher","first-page":"A62","DOI":"10.1016\/j.ajic.2019.01.017","volume":"47","author":"WA Rutala","year":"2019","unstructured":"Rutala WA, Kanamori H, Sickbert-Bennett EE, Weber DJ (2019) What\u2019s new in reprocessing endoscopes: Are we going to ensure \u201cthe needs of the patient come first\u201d by shifting from disinfection to sterilization? Am J Infect Control 47:A62\u2013A66","journal-title":"Am J Infect Control"},{"key":"5617_CR11","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1016\/j.juro.2010.08.001","volume":"184","author":"JQ Clemens","year":"2010","unstructured":"Clemens JQ, Dowling R, Foley F, Goldman HB, Gonzalez CM, Tessier C et al (2010) Joint AUA\/SUNA white paper on reprocessing of flexible cystoscopes. J Urol 184:2241\u20132245","journal-title":"J Urol"},{"key":"5617_CR12","unstructured":"Speer T, Alfa M, Cowen A, Jones D, Vickery K, Griffiths H, et al. Endoscope disinfection update: a guide to resource-sensitive reprocessing. 2019;"},{"key":"5617_CR13","unstructured":"2014 American Urological Association Education and Research, Inc. and the Society of Urologic Nurses and Associates."},{"key":"5617_CR14","doi-asserted-by":"publisher","first-page":"E247","DOI":"10.1055\/a-1991-1391","volume":"11","author":"L Pineau","year":"2023","unstructured":"Pineau L (2023) Endoscope reprocessing: retrospective analysis of 90,311 samples. Endosc Int Open 11:E247\u2013E257","journal-title":"Endosc Int Open"},{"key":"5617_CR15","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1017\/ice.2015.123","volume":"36","author":"P Saviuc","year":"2015","unstructured":"Saviuc P, Picot-Gu\u00e9raud R, Sing JSC, Batailler P, Pelloux I, Brenier-Pinchart MP et al (2015) Evaluation of the quality of reprocessing of gastrointestinal endoscopes. Infect Control Hosp Epidemiol 36:1017\u20131023","journal-title":"Infect Control Hosp Epidemiol"},{"key":"5617_CR16","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1086\/433190","volume":"41","author":"RA Weinstein","year":"2005","unstructured":"Weinstein RA, Linkin DR, Sausman C, Santos L, Lyons C, Fox C et al (2005) Applicability of healthcare failure mode and effects analysis to healthcare epidemiology: evaluation of the sterilization and use of surgical instruments. Clin Infect Dis 41:1014\u20131019","journal-title":"Clin Infect Dis"},{"key":"5617_CR17","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1111\/jep.13317","volume":"26","author":"H Liu","year":"2020","unstructured":"Liu H, Zhang L, Ping Y, Wang L (2020) Failure mode and effects analysis for proactive healthcare risk evaluation: a systematic literature review. J Eval Clin Pract 26:1320\u20131337","journal-title":"J Eval Clin Pract"},{"key":"5617_CR18","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.giec.2020.06.002","volume":"30","author":"NB Marya","year":"2020","unstructured":"Marya NB, Muthusamy RV (2020) Methods for endoscope reprocessing. Gastrointest Endosc Clin N Am 30:665\u2013675","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"5617_CR19","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1097\/SGA.0b013e3181e9431a","volume":"33","author":"CL Ofstead","year":"2010","unstructured":"Ofstead CL, Wetzler HP, Snyder AK, Horton RA (2010) Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Gastroenterol Nurs 33:304\u2013311","journal-title":"Gastroenterol Nurs"},{"key":"5617_CR20","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1016\/j.ajic.2014.07.029","volume":"42","author":"W Ren-Pei","year":"2014","unstructured":"Ren-Pei W, Hui-Jun X, Ke Q, Dong W, Xing N, Zhao-Shen L (2014) Correlation between the growth of bacterial biofilm in flexible endoscopes and endoscope reprocessing methods. Am J Infect Control 42:1203\u20131206","journal-title":"Am J Infect Control"},{"key":"5617_CR21","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.jhin.2014.01.007","volume":"86","author":"SE Funk","year":"2014","unstructured":"Funk SE, Reaven NL (2014) High-level endoscope disinfection processes in emerging economies: financial impact of manual process versus automated endoscope reprocessing. J Hosp Infect 86:250\u2013254","journal-title":"J Hosp Infect"},{"key":"5617_CR22","unstructured":"8db4239b-660e-4bb4\u201395b6\u20135cc791d9847d.pdf [Internet]. [cited 2025 Jan 29]. Available from: https:\/\/www.um.es\/documents\/4874468\/11902306\/guia-desinfeccion-endoscopios.pdf\/8db4239b-660e-4bb4-95b6-5cc791d9847d?utm_source=chatgpt.com"},{"key":"5617_CR23","unstructured":"REGLAMENTO (UE) 2017\/ 745 DEL PARLAMENTO EUROPEO Y DEL CONSEJO - de 5 de abril de 2017 - sobre los productos sanitarios, por el que se modifican la Directiva 2001\/ 83\/ CE, el Reglamento (CE) n.o 178\/ 2002 y el Reglamento (CE) n.o 1223\/ 2009 y por el que se derogan las Directivas 90\/ 385\/ CEE y 93\/ 42\/ CEE del Consejo."},{"key":"5617_CR24","unstructured":"Unidad central de esterilizaci\u00f3n. Est\u00e1ndares y recomendaciones | sempspgs.es [Internet]. [cited 2023 Oct 19]. Available from: https:\/\/www.sempspgs.es\/es\/-9-Higiene-y-reprocesado-de-material-clinico\/111-Unidad-central-de-esterilizacion-Estandares-y-recomendaciones.htm"},{"key":"5617_CR25","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.aorn.2016.01.018","volume":"103","author":"MM Goh","year":"2016","unstructured":"Goh MM, Tan ABH, Leong MHW (2016) Bar code-based management to enhance efficiency of a sterile supply unit in Singapore. AORN J 103:407\u2013413","journal-title":"AORN J"},{"key":"5617_CR26","first-page":"18","volume":"13","author":"R Neil","year":"2004","unstructured":"Neil R (2004) Keeping track. mater manag. Health Care 13:18\u201321","journal-title":"Health Care"},{"key":"5617_CR27","unstructured":"Health C for D and R. Infections Associated with Reprocessed Urological Endoscopes - Letter to Health Care Providers. FDA [Internet]. 2022 [cited 2023 Oct 19]; Available from: https:\/\/www.fda.gov\/medical-devices\/letters-health-care-providers\/infections-associated-reprocessed-urological-endoscopes-letter-health-care-providers"},{"key":"5617_CR28","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1089\/end.2022.0201","volume":"36","author":"T Boucheron","year":"2022","unstructured":"Boucheron T, Lechevallier E, Gondran-Tellier B, Michel F, Bastide C, Martin N et al (2022) Cost and environmental impact of disposable flexible cystoscopes compared to reusable devices. J Endourol 36:1317\u20131321","journal-title":"J Endourol"},{"key":"5617_CR29","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.euf.2022.12.006","volume":"9","author":"M Baboudjian","year":"2023","unstructured":"Baboudjian M, Pradere B, Martin N, Gondran-Tellier B, Angerri O, Boucheron T et al (2023) Life cycle assessment of reusable and disposable cystoscopes: a path to greener urological procedures. Eur Urol Focus 9:681\u2013687","journal-title":"Eur Urol Focus"},{"key":"5617_CR30","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1111\/bju.15949","volume":"131","author":"JP Kemble","year":"2023","unstructured":"Kemble JP, Winoker JS, Patel SH, Su ZT, Matlaga BR, Potretzke AM et al (2023) Environmental impact of single-use and reusable flexible cystoscopes. BJU Int 131:617\u2013622","journal-title":"BJU Int"},{"key":"5617_CR31","first-page":"187","volume":"13","author":"M Schmelzer","year":"2015","unstructured":"Schmelzer M, Daniels G, Hough H (2015) Safe storage time for reprocessed flexible endoscopes: a systematic review: JBI Database. Syst Rev Implement Rep 13:187\u2013243","journal-title":"Syst Rev Implement Rep"},{"key":"5617_CR32","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.ajic.2023.03.002","volume":"51","author":"CL Ofstead","year":"2023","unstructured":"Ofstead CL, Smart AG, Hopkins KM, Lamb LA, Daniels FE, Berg DS (2023) Improving mastery and retention of knowledge and complex skills among sterile processing professionals: a pilot study on borescope training and competency testing. Am J Infect Control 51:624\u2013632","journal-title":"Am J Infect Control"},{"key":"5617_CR33","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1046\/j.1464-4096.2001.01899.x","volume":"89","author":"DM Burke","year":"2002","unstructured":"Burke DM, Shackley DC, O\u2019Reilly PH (2002) The community-based morbidity of flexible cystoscopy. BJU Int 89:347\u2013349","journal-title":"BJU Int"},{"key":"5617_CR34","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/S0090-4295(00)00555-0","volume":"56","author":"YZ Almallah","year":"2000","unstructured":"Almallah YZ, Rennie CD, Stone J, Lancashire MJR (2000) Urinary tract infection and patient satisfaction after flexible cystoscopy and urodynamic evaluation. Urology 56:37\u201339","journal-title":"Urology"},{"key":"5617_CR35","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1016\/j.ajic.2019.05.005","volume":"47","author":"E Sorbets","year":"2019","unstructured":"Sorbets E, Evrevin M, Jumas-Bilak E, Masnou A, Lotth\u00e9 A, Thuret R et al (2019) An outbreak of Pseudomonas aeruginosa urinary tract infections following outpatient flexible cystoscopy. Am J Infect Control 47:1510\u20131512","journal-title":"Am J Infect Control"},{"key":"5617_CR36","doi-asserted-by":"publisher","first-page":"1852","DOI":"10.1093\/ajhp\/zxaa270","volume":"77","author":"JA Cusumano","year":"2020","unstructured":"Cusumano JA, Hermenau M, Gaitanis M, Travis M, LaPlante KL, Tran TY et al (2020) Evaluation of post\u2013flexible cystoscopy urinary tract infection rates. Am J Health Syst Pharm 77:1852\u20131858","journal-title":"Am J Health Syst Pharm"},{"key":"5617_CR37","doi-asserted-by":"publisher","first-page":"2728","DOI":"10.1007\/s00464-015-4537-7","volume":"30","author":"ACP Gu\u00e9don","year":"2016","unstructured":"Gu\u00e9don ACP, Wauben LSGL, Van Der Eijk AC, Vernooij ASN, Meeuwsen FC, Van Der Elst M et al (2016) Where are my instruments? hazards in delivery of surgical instruments. Surg Endosc 30:2728\u20132735","journal-title":"Surg Endosc"}],"container-title":["World Journal of Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00345-025-05617-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00345-025-05617-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00345-025-05617-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T13:52:31Z","timestamp":1767966751000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00345-025-05617-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,30]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["5617"],"URL":"https:\/\/doi.org\/10.1007\/s00345-025-05617-1","relation":{},"ISSN":["1433-8726"],"issn-type":[{"value":"1433-8726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,30]]},"assertion":[{"value":"6 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"258"}}