{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,23]],"date-time":"2025-04-23T09:07:16Z","timestamp":1745399236782},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2014,12,12]],"date-time":"2014-12-12T00:00:00Z","timestamp":1418342400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmologe"],"published-print":{"date-parts":[[2015,9]]},"DOI":"10.1007\/s00347-014-3188-8","type":"journal-article","created":{"date-parts":[[2014,12,10]],"date-time":"2014-12-10T13:05:45Z","timestamp":1418216745000},"page":"770-777","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Pachymetrie und Augeninnendruckmessung mittels Corneal-Visualization-Scheimpflug-Technologie (Corvis\u00a0ST)"],"prefix":"10.1007","volume":"112","author":[{"given":"J.","family":"Steinberg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Mehlan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Frings","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"Druchkiv","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Richard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Katz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.J.","family":"Linke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,12,12]]},"reference":[{"key":"3188_CR1","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/s00347-013-2843-9","volume":"111","author":"Arend","year":"2014","unstructured":"Arend N, Hirneiss C, Kernt M (2014) Differences in the measurement results of Goldmann applanation tonometry with and without fluorescein. Ophthalmologe 111:241\u2013246","journal-title":"Ophthalmologe"},{"key":"3188_CR2","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1016\/j.jcrs.2005.03.058","volume":"31","author":"Barkana","year":"2005","unstructured":"Barkana Y, Gerber Y, Elbaz U et al (2005) Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 31:1729\u20131735","journal-title":"J Cataract Refract Surg"},{"key":"3188_CR3","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1080\/02713680600801115","volume":"31","author":"Basmak","year":"2006","unstructured":"Basmak H, Sahin A, Yildirim N (2006) The reliability of central corneal thickness measurements by ultrasound and by Orbscan system in schoolchildren. Curr Eye Res 31:569\u2013575","journal-title":"Curr Eye Res"},{"key":"3188_CR4","first-page":"302","volume":"7","author":"Bayhan","year":"2014","unstructured":"Bayhan HA, Aslan Bayhan S, Can I (2014) Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter. Int J Ophthalmol 7:302\u2013308","journal-title":"Int J Ophthalmol"},{"key":"3188_CR5","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1159\/000304918","volume":"151","author":"Bechrakis","year":"1966","unstructured":"Bechrakis E (1966) On spontaneous decrease of pressure in applanation tonometry. Ophthalmologica 151:604\u2013614","journal-title":"Ophthalmologica"},{"key":"3188_CR6","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1055\/s-0029-1245776","volume":"228","author":"Beutelspacher","year":"2011","unstructured":"Beutelspacher SC, Serbecic N, Scheuerle AF (2011) Measurement of the central corneal thickness using optical reflectometry and ultrasound. Klin Monatsbl Augenheilkd 228:815\u2013818","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"3188_CR7","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1038\/eye.2009.297","volume":"24","author":"Briesen","year":"2010","unstructured":"Briesen S, Schulze Schwering M, Roberts H et al (2010) Minimal cross-infection risk through Icare rebound tonometer probes: a useful tool for IOP-screenings in developing countries. Eye 24:1279\u20131283","journal-title":"Eye"},{"key":"3188_CR8","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1111\/j.1755-3768.2010.01947.x","volume":"90","author":"Chen","year":"2012","unstructured":"Chen S, Huang J, Wen D et al (2012) Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry. Acta Ophthalmol 90:449\u2013455","journal-title":"Acta Ophthalmol"},{"key":"3188_CR9","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1016\/j.ophtha.2014.04.041","volume":"10","author":"Chua","year":"2014","unstructured":"Chua J, Tham YC, Liao J et al (2014) Ethnic differences of intraocular pressure and central corneal thickness: the Singapore Epidemiology of Eye Diseases study. Ophthalmology 10:2013\u20132022","journal-title":"Ophthalmology"},{"key":"3188_CR10","doi-asserted-by":"crossref","unstructured":"Cinar Y, Cingu AK, Turkcu FM et al (2013) Comparison of central corneal thickness measurements with a rotating Scheimpflug camera, a specular microscope, optical low-coherence reflectometry, and ultrasound pachymetry in keratoconic eyes. Semin Ophthalmol [Epub ahead of print]","DOI":"10.3109\/08820538.2013.833264"},{"key":"3188_CR11","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1016\/j.ophtha.2012.02.030","volume":"119","author":"Cook","year":"2012","unstructured":"Cook JA, Botello AP, Elders A et al (2012) Systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology 119:1552\u20131557","journal-title":"Ophthalmology"},{"key":"3188_CR12","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.ophtha.2006.06.047","volume":"114","author":"Francis","year":"2007","unstructured":"Francis BA, Hsieh A, Lai MY et al (2007) Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology 114:20\u201326","journal-title":"Ophthalmology"},{"key":"3188_CR13","doi-asserted-by":"crossref","first-page":"475","DOI":"10.3109\/02713681003678824","volume":"35","author":"Gaton","year":"2010","unstructured":"Gaton DD, Ehrenberg M, Lusky M et al (2010) Effect of repeated applanation tonometry on the accuracy of intraocular pressure measurements. Curr Eye Res 35:475\u2013479","journal-title":"Curr Eye Res"},{"key":"3188_CR14","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1167\/iovs.12-10984","volume":"54","author":"Hong","year":"2013","unstructured":"Hong J, Xu J, Wei A et al (2013) A new tonometer \u2013 the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci 54:659\u2013665","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"3188_CR15","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","volume":"157","author":"Huseynova","year":"2014","unstructured":"Huseynova T, Waring GOT, Roberts C et al (2014) Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes. Am J Ophthalmol 157:885\u2013893","journal-title":"Am J Ophthalmol"},{"key":"3188_CR16","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1111\/aos.12058","volume":"92","author":"Johannesson","year":"2014","unstructured":"Johannesson G, Hallberg P, Eklund A et al (2014) Effects of topical anaesthetics and repeated tonometry on intraocular pressure. Acta Ophthalmol 92:111\u2013115","journal-title":"Acta Ophthalmol"},{"key":"3188_CR17","doi-asserted-by":"crossref","first-page":"2239","DOI":"10.2147\/OPTH.S53718","volume":"7","author":"Kanellopoulos","year":"2013","unstructured":"Kanellopoulos AJ, Asimellis G (2013) Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements. Clin Ophthalmol 7:2239\u20132247","journal-title":"Clin Ophthalmol"},{"key":"3188_CR18","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.ophtha.2009.09.020","volume":"117","author":"Kotecha","year":"2010","unstructured":"Kotecha A, White E, Schlottmann PG et al (2010) Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Ophthalmology 117:730\u2013737","journal-title":"Ophthalmology"},{"key":"3188_CR19","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","volume":"31","author":"Liu","year":"2005","unstructured":"Liu J, Roberts CJ (2005) Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 31:146\u2013155","journal-title":"J Cataract Refract Surg"},{"key":"3188_CR20","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.clae.2012.05.004","volume":"35","author":"Ogbuehi","year":"2012","unstructured":"Ogbuehi KC, Chijuka JC, Osuagwu UL (2012) Changes in central corneal thickness values after instillation of oxybuprocaine hydrochloride 0.4\u2009%. Cont Lens Anterior Eye 35:199\u2013202","journal-title":"Cont Lens Anterior Eye"},{"key":"3188_CR21","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.clae.2013.09.006","volume":"37","author":"Ogbuehi","year":"2014","unstructured":"Ogbuehi KC, Osuagwu UL (2014) Corneal biomechanical properties: precision and influence on tonometry. Cont Lens Anterior Eye 37:124\u2013131","journal-title":"Cont Lens Anterior Eye"},{"key":"3188_CR22","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1136\/bjophthalmol-2013-303400","volume":"97","author":"Reznicek","year":"2013","unstructured":"Reznicek L, Muth D, Kampik A et al (2013) Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma. Br J Ophthalmol 97:1410\u20131414","journal-title":"Br J Ophthalmol"},{"key":"3188_CR23","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","volume":"40","author":"Roberts","year":"2014","unstructured":"Roberts CJ (2014) Concepts and misconceptions in corneal biomechanics. J Cataract Refract Surg 40:862\u2013869","journal-title":"J Cataract Refract Surg"},{"key":"3188_CR24","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1007\/s00347-011-2370-5","volume":"108","author":"Rufer","year":"2011","unstructured":"Rufer F (2011) Sources of error in Goldmann applanation tonometry. Ophthalmologe 108:546\u2013552","journal-title":"Ophthalmologe"},{"key":"3188_CR25","doi-asserted-by":"crossref","first-page":"e102","DOI":"10.1097\/ICO.0b013e318275e7a6","volume":"32","author":"Sanchis-Gimeno","year":"2013","unstructured":"Sanchis-Gimeno JA, Palanca-Sanfrancisco JM, Garcia-Lazaro S et al (2013) The effect of anesthetic eye drop instillation on the distribution of corneal thickness. Cornea 32:e102\u2013e105","journal-title":"Cornea"},{"key":"3188_CR26","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1167\/iovs.13-13172","volume":"55","author":"Smedowski","year":"2014","unstructured":"Smedowski A, Weglarz B, Tarnawska D et al (2014) Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea. Invest Ophthalmol Vis Sci 55:666\u2013673","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"3188_CR27","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1136\/bjo.2004.056614","volume":"89","author":"Tonnu","year":"2005","unstructured":"Tonnu PA, Ho T, Sharma K et al (2005) A comparison of four methods of tonometry: method agreement and interobserver variability. Br J Ophthalmol 89:847\u2013850","journal-title":"Br J Ophthalmol"},{"key":"3188_CR28","first-page":"674","volume":"109","author":"Wellek","year":"2012","unstructured":"Wellek S, Blettner M (2012) Establishing equivalence or non-inferiority in clinical trials: part 20 of a series on evaluation of scientific publications. Dtsch Arztebl Int 109:674\u2013679","journal-title":"Dtsch Arztebl Int"},{"key":"3188_CR29","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1097\/PEC.0b013e3181f0cce8","volume":"26","author":"Yamamoto","year":"2010","unstructured":"Yamamoto LG, Young DA (2010) Tonometry methods in the pediatric emergency department. Pediatr Emerg Care 26:678\u2013683 (quiz 684\u2013685)","journal-title":"Pediatr Emerg Care"}],"container-title":["Der Ophthalmologe"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-014-3188-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00347-014-3188-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-014-3188-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,18]],"date-time":"2019-08-18T09:18:30Z","timestamp":1566119910000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00347-014-3188-8"}},"subtitle":["Ein klinischer Vergleich zum Goldstandard"],"short-title":[],"issued":{"date-parts":[[2014,12,12]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["3188"],"URL":"https:\/\/doi.org\/10.1007\/s00347-014-3188-8","relation":{},"ISSN":["0941-293X","1433-0423"],"issn-type":[{"value":"0941-293X","type":"print"},{"value":"1433-0423","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,12]]}}}